3 resultados para Milking.

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study was conducted to determine the relationship among temperatures measured at different anatomical sites of the animal body and their daily pattern as indicative of the thermal stress in lactating dairy cows under tropical conditions. Environmental dry bulb (DBT) and black globe (BGT) temperatures and relative humidity (RH) were recorded. Rectal temperature (RT), respiratory frequency (RF), body surface (BST), internal base of tail (TT), vulva (VT) and auricular temperatures (AT) were collected, from 37 Black and White Holstein cows at 0700, 1300 and 1800 hours. RT showed a moderately and positive correlations with all body temperatures, ranging from 0.59 with TT to 0.64 with BST. Correlations among AT, VT and TT with RF were very similar (from 0.63 to 0.64) and were greater than those observed for RF with RT (0.55) or with BST (0.54). RF and RT were positively correlated to TT (0.63 and 0.59, respectively), AT (r = 0.63 for both) and VT (r = 0.64 and 0.63, respectively). Positive and very high correlations were observed among AT, VT and TT (from 0.94 to 0.97) indicating good association of temperatures measured in these anatomical sites. Correlations of BST with AT and VT were positive and very similar (0.71 and 0.72, respectively) and lower with TT (0.66). The AT, TT, VT and BST presented similar patterns and follow the variations of DBT through the day. Temperatures measured at different anatomical sites of the animal body have the potential to be used as indicative of the thermal stress in lactating dairy cows.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There are several different milking management systems in Latin America, because Gir cattle are reputed to be easily stressed and not well adapted to machine-milking. This paper, therefore, provides an overview of hormone release and behavior during suckling and milking in Gir cows and their crossbred offspring. Several experiments were performed to study oxytocin release during exclusive suckling or exclusive hand- and machine-milking, oxytocin, and prolactin release during a mixed suckling-milking system and oxytocin release after weaning. Cortisol concentrations and behavior were also examined. Concentration of oxytocin, released during suckling, and both types of milking were high, but the maximum concentration measured during suckling was significantly greater than that observed during exclusive milking. In the mixed suckling-milking system, the greatest oxytocin and prolactin releases were measured during suckling. Cortisol concentrations measured before, during, and after milking demonstrated that Gir x Holstein and Holstein cows were not stressed. On the other hand, although Gir had greater concentrations of cortisol, the percentage of residual milk for Gir cows was less than for dairy cows exposed to different stressful situations. In general, Gir cows and their crossbred offspring adapted to machine-milking, although these breeds can react negatively to milkers. Gir, Gir x Holstein, and Holstein cows all had similar cortisol levels during and after milking.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In order to assess the influence of the colostrum period on pH and, electrical conductivity, we collected 418 milk samples from 127 Jersey cows. The samples were collected from healthy udders that did not present any bacterial growth in the microbiological examination. They were divided into eight groups as follows < 1/2 day; 1/2 and 1 degrees day; 2 degrees day; 3 degrees day; 4 degrees and 5 degrees day; 6 degrees and 7 degrees day; 8 degrees to 15 degrees day; 16 degrees to 30 degrees days of lactation. The samples were collected before milking and the following analyses were conducted: pH, electrical conductivity. In the first 24 hours of lactation, there was an reduction in electrical conductivity value, associated with an increase in pH value. We observed that transition of secretion from colostrum to milk, occurs during the first week of lactation; from 6(rd) day of lactation for pH value and 3(th) day for electrical conductivity value. We recommend the use the following figures as normal ranges for the first 24 hours of lactation (colostrum period): pH <= 6,51 and electrical conductivity <= 6,33 mS/cm; while for the interval between 2(nd) and 7(th) days of lactation (transition from colostrum to milk) we suggest the use of the values as normal ranges: pH <= 6,66 and electrical conductivity <= 5,93 mS/cm.