16 resultados para Micro total analysis system

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to develop a fast capillary electrophoresis method for the determination of propranolol in pharmaceutical preparations. In the method development the pH and constituents of the background electrolyte were selected using the effective mobility versus pH curves. Benzylamine was used as the internal standard. The background electrolyte was composed of 60 mmol L(-1) tris(hydroxymethyl)aminomethane and 30 mmol L(-1) 2-hydroxyisobutyric acid,at pH 8.1. Separation was conducted in a fused-silica capillary (32 cm total length and 8.5 cm effective length, 50 mu m I.D.) with a short-end injection configuration and direct UV detection at 214 nm. The run time was only 14 s. Three different strategies were studied in order to develop a fast CE method with low total analysis time for propranolol analysis: low flush time (Lflush) 35 runs/h, without flush (Wflush) 52 runs/h, and Invert (switched polarity) 45 runs/h. Since the three strategies developed are statistically equivalent, Mush was selected due to the higher analytical frequency in comparison with the other methods. A few figures of merit of the proposed method include: good linearity (R(2) > 0.9999); limit of detection of 0.5 mg L(-1): inter-day precision better than 1.03% (n = 9) and recovery in the range of 95.1-104.5%. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A column switching LC method is presented for the analysis of fluoxetine (FLU) and norfluoxetine (NFLU) by direct injection of human plasma using a lab-made restricted access media (RAM) column. A RAM-BSA-octadecyl silica (C-18) column (40 min x 4.6 mm, 10 mu m) is evaluated in both backflush and foreflush elution modes and coupled with a C-18 lab-made (50 mm x 4.6 mm, 3 pm) analytical column in order to perform online sample preparation. Direct injection of 100 mu L, of plasma samples is possible with the developed approach. In addition, reduction of sample handling is obtained when compared with traditional liquid-liquid extraction (LLE) and SPE. The total analysis time is around 20 min. A LOQ of 15 ng/mL is achieved in a concentration range of 15-500 ng/mL, allowing the therapeutic drug monitoring of clinical samples. The precision values achieved are lower than 15% for all the evaluated points with adequate recovery and accuracy. Furthermore, no matrix interferences are found in the analysis and the proposed method shows to be an adequate alternative for analysis of FLU in plasma.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives. To study mortality trends related to Chagas disease taking into account all mentions of this cause listed on any line or part of the death certificate. Methods. Mortality data for 1985-2006 were obtained from the multiple cause-of-death database maintained by the Sao Paulo State Data Analysis System (SEADE). Chagas disease was classified as the underlying cause-of-death or as an associated cause-of-death (non-underlying). The total number of times Chagas disease was mentioned on the death certificates was also considered. Results. During this 22-year period, there were 40 002 deaths related to Chagas disease: 34 917 (87.29%) classified as the underlying cause-of-death and 5 085 (12.71%) as an associated cause-of-death. The results show a 56.07% decline in the death rate due to Chagas disease as the underlying cause and a stabilized rate as associated cause. The number of deaths was 44.5% higher among men. The fact that 83.5% of the deaths occurred after 45 years of age reflects a cohort effect. The main causes associated with Chagas disease as the underlying cause-of-death were direct complications due to cardiac involvement, such as conduction disorders, arrhythmias and heart failure. Ischemic heart disease, cerebrovascular disorders and neoplasms were the main underlying causes when Chagas was an associated cause-of-death. Conclusions. For the total mentions to Chagas disease, a 51.34% decline in the death rate was observed, whereas the decline in the number of deaths was only 5.91%, being lower among women and showing a shift of deaths to older age brackets. Using the multiple cause-of-death method contributed to the understanding of the natural history of Chagas disease.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective. To investigate mortality in which paracoccidioidomycosis appears on any line or part of the death certificate. Method. Mortality data for 1985-2005 were obtained from the multiple cause-of-death database maintained by the Sao Paulo State Data Analysis System (SEADE). Standardized mortality coefficients were calculated for paracoccidioidomycosis as the underlying cause-of-death and as an associated cause-of-death, as well as for the total number of times paracoccidioidomycosis was mentioned on the death certificates. Results. During this 21-year period, there were 1950 deaths related to paracoccidioidomycosis; the disease was the underlying cause-of-death in 1 164 cases (59.69%) and an associated cause-of-death in 786 (40.31%). Between 1985 and 2005 records show a 59.8% decline in the mortality coefficient due to paracoccidioidomycosis as the underlying cause and a 53.0% decline in the mortality as associated cause. The largest number of deaths occurred among men, in the older age groups, and among rural workers, with an upward trend in winter months. The main causes associated with paracoccidioidomycosis as the underlying cause-of-death were pulmonary fibrosis, chronic lower respiratory tract diseases, and pneumonias. Malignant neoplasms and AIDS were the main underlying causes when paracoccidioidomycosis was an associated cause-of-death. The decision tables had to be adapted for the automated processing of causes of death in death certificates where paracoccidioidomycosis was mentioned. Conclusions. Using the multiple cause-of-death method together with the traditional underlying cause-of-death approach provides a new angle on research aimed at broadening our understanding of the natural history of paracoccidioidomycosis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: The aim of this study was to evaluate, through fluorescence analysis, the effect that different interimplant distances, after prosthetic restoration, will have on bone remodeling in submerged and nonsubmerged implants restored with a ""platform switch."" Materials and Methods: Fifty-six Ankylos implants were placed 1.5 mm subcrestally in seven dogs. The implants were placed so that two fixed prostheses, with three interimplant contacts separated by 1-mm, 2-mm, and 3-mm distances, could be fabricated for each side of the mandible. The sides and the positions of the groups were selected randomly. To better evaluate bone remodeling, calcein green was injected 3 days before placement of the prostheses at 12 weeks postimplantation. At 3 days before sacrifice (8 weeks postloading), alizarin red was injected. The amounts of remodeled bone within the different interimplant areas were compared statistically before and after loading in submerged and nonsubmerged implants. Results: Statistically significant differences existed in the percentage of remodeled bone seen in the different regions. Mean percentages of remodeled bone in the submerged and nonsubmerged groups, respectively, were as follows: for the 1-mm distance, 23.0% +/- 0.05% and 23.1% +/- 0.03% preloading and 27.0% +/- 0.03% and 25.2% +/- 0.04% postloading, for the 2-mm distance, 18.2% +/- 0.05% and 18.1% +/- 0.04% preloading and 21.3% +/- 0.07% and 19.9% +/- 0.03% postloading, for the 3-mm distance, 18.3% +/- 0.03% and 18.3% +/- 0.03% preloading and 18.8% +/- 0.04% and 19.8% +/- 0.04% postloading, for distal-extension regions, 16.6% +/- 0.02% and 17.4% +/- 0.04% preloading and 17.0% +/- 0.04% and 18.4% +/- 0.04% postloading. Conclusions: Based upon this animal study, loading increases bone formation for submerged or nonsubmerged implants, and the interimplant distance of 1 mm appears to result in more pronounced bone remodeling than the 2-mm or 3-mm distances in implants with a ""platform switch."" INT J ORAL MAXILLOFAC IMPLANTS 2009;24:257-266

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper deals with the effect of silica fume and styrene-butadiene latex (SBR) on the microstructure of the interfacial transition zone (ITZ) between Portland cement paste and aggregates (basalt). Scanning electron microscope (SEM) equipped with energy dispersive X-ray analysis system (EDX) was used to determine the ITZ thickness. In the plain concrete a marked ITZ around the aggregate particles (55 mu m) was observed, while in concretes with silica fume or latex SBR the ITZ was less pronounced (35-40 mu m). However, better results were observed in concretes with silica fume and latex SBR (20-25 mu m). (C) 2008 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: The aim of this study was to evaluate the effect of raloxifene on CD34 and Ki-67 antigen expression in breast cancer specimens from postmenopausal women. Methods: Sixteen postmenopausal patients with operable, stage II (>= 3 cm), estrogen receptor-positive breast cancer, who took 60 mg of raloxifene daily for 28 days, participated in this study. Immunohistochemistry was carried out in tumor samples prior to and following raloxifene treatment to evaluate CD34 and Ki-67 protein expression. Angiogenesis was quantified in 10 randomly selected fields per slide, and Ki-67-stained nuclei were counted in 1,000 cells per slide using an image capture and analysis system with 400 ! magnification. Student`s t test for paired samples was used for the statistical analysis of data. Statistical significance was established at p < 0.05. Results: The mean number of microvessels was 44.44 +/- 3.54 prior to raloxifene therapy and 22.63 +/- 1.61 following therapy (p < 0.001), and the mean percentage of Ki-67-stained nuclei was 19.28 +/- 8 1.61 and 12.13 +/- 8 1.48 prior to and following raloxifene treatment, respectively (p < 0.001). Conclusion: Raloxifene significantly reduces CD34 and Ki-67 protein expression in breast carcinoma in postmenopausal women. Copyright (C) 2008 S. Karger AG, Basel

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Captopril (CAP) was the first commercially available angiotensine-converting enzyme (ACE) inhibitor. In the anti-hypertensive therapy is considered the selected drug has to be therapeutically effective together with reduced toxicity. CAP is an antihypertensive drug currently being administered in tablet form. In order to investigate the possible interactions between CAP and excipients in tablets formulations, differential scanning calorimetry (DSC) and thermogravimetric (TG) analysis completed by X-ray powder diffraction (XRPD) and Fourier transform infrared spectroscopy (FTIR) were used for compatibility studies. A possible drug-excipient interaction was observed with magnesium stearate by DSC technique.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Several methods have been utilized to prevent pericardial and retrosternal adhesions, but none of them evaluated the mesothelial regenerative hypothesis. There are evidences that the mesothelial trauma reduces pericardial fibrinolytic capability and induces an adhesion process. Keratinocyte growth factor (KGF) has proven to improve mesothelial cells proliferation. This study investigated the influence of keratinocyte growth factor in reducing post-surgical adhesions. Methods: Twelve pigs were operated and an adhesion protocol was employed. Following a stratified randomization, the animals received a topical application of KGF or saline. At 8 weeks, intrapericardial adhesions were evaluated and a severity score was established. The time spent to dissect the adhesions and the amount of sharp dissection used, were recorded. Histological sections were stained with sirius red and morphometric analyses were assessed with a computer-assisted image analysis system. Results: The severity score was lower in the KGF group than in the control group (11.5 vs 17, p = 0.005). The dissection time was lower in the KGF group (9.2 +/- 1.4 min vs 33.9 +/- 9.2 min, p = 0.004) and presented a significant correlation with the severity score (r = 0.83, p = 0.001). A significantly less sharp dissection was also required in the KGF group. Also, adhesion area and adhesion collagen were significantly tower in the KGF group than in the control group. Conclusion: The simulation of pericardial cells with KGF reduced the intensity of postoperative adhesions and facilitated the re-operation. This study suggests that the mesothelial regeneration is the new horizon in anti-adhesion therapies. (C) 2008 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background. Mesothelial injury is the pivot in the development of adhesions. An increase in the proliferation of mesothelial cells was verified by in vitro studies with the use of keratinocyte growth factor (KGF). This study investigated the influence of KGF associated with thermo-sterilized carboxymethyl chitosan (NOCCts) in the reduction of pericardial adhesions. Methods. An induction model of pericardial adhesion was carried out in 24 pigs. Animals were randomly allocated to receive topical application of KGF, KGF + NOCCts, NOCCts, or saline (control). At 8 weeks, intra-pericardial adhesions were evaluated and a severity score was established. The time spent to dissect the adhesions and the amount of sharp dissection used, were recorded. Histologic sections were stained with sirius red for a morphometric evaluation using a computer-assisted image analysis system. Cytokeratin AE1/AE3 immunostaining were employed to identify mesothelial cells. Results. The severity score expressed in median (minimum to maximum), in relation to the control group (17 [15 to 18]), was lower in the KGF + NOCCts group (7 [6 to 9], p < 0.01) followed by the KGF group (11.5 [9 to 12], 0.01 < p < 0.05) and the NOCCts group (12 [9 to 14], p > 0.05). The dissection time was significantly lower in the KGF + NOCCts group (7.1 +/- 0.6 vs 33.9 +/- 9.2 minutes, p < 0.001). A significantly less sharp dissection was also required in the KGF + NOCCts group. In the adhesion segment, a decreased collagen proportion was found in the KGF + NOCCts group (p < 0.05). Mesothelial cells were present more extensively in groups in which KGF was delivered (p = 0.01). Conclusions. The use of KGF associated with NOCCts resulted in a synergic action that decreases postoperative pericardial adhesions in a highly significant way. (Ann Thorac Surg 2010; 90: 566-72) (C) 2010 by The Society of Thoracic Surgeons

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this report, we describe the microfabrication and integration of planar electrodes for contactless conductivity detection on polyester-toner (PT) electrophoresis microchips using toner masks. Planar electrodes were fabricated by three simple steps: (i) drawing and laser-printing the electrode geometry on polyester films, (ii) sputtering deposition onto substrates, and (iii) removal of toner layer by a lift-off process. The polyester film with anchored electrodes was integrated to PT electrophoresis microchannels by lamination at 120 degrees C in less than 1 min. The electrodes were designed in an antiparallel configuration with 750 mu m width and 750 gm gap between them. The best results were recorded with a frequency of 400 kHz and 10 V-PP using a sinusoidal wave. The analytical performance of the proposed microchip was evaluated by electrophoretic separation of potassium, sodium and lithium in 150 mu m wide x 6 mu m deep microchannels. Under an electric field of 250 V/cm the analytes were successfully separated in less than 90 s with efficiencies ranging from 7000 to 13 000 plates. The detection limits (S/N = 3) found for K+, Na+, and Li+ were 3.1, 4.3, and 7.2 mu mol/L, respectively. Besides the low-cost and instrumental simplicity, the integrated PT chip eliminates the problem of manual alignment and gluing of the electrodes, permitting more robustness and better reproducibility, therefore, more suitable for mass production of electrophoresis microchips.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this report, we describe a rapid and reliable process to bond channels fabricated in glass substrates. Glass channels were fabricated by photolithography and wet chemical etching. The resulting channels were bonded against another glass plate containing a 50-mu m thick PDMS layer. This same PDMS layer was also used to provide the electrical insulation of planar electrodes to carry out capacitively coupled contactless conductivity detection. The analytical performance of the proposed device was shown by using both LIF and capacitively coupled contactless conductivity detection systems. Efficiency around 47 000 plates/m was achieved with good chip-to-chip repeatability and satisfactory long-term stability of EOF. The RSD for the EOF measured in three different devices was ca. 7%. For a chip-to-chip comparison, the RSD values for migration time, electrophoretic current and peak area were below 10%. With the proposed approach, a single chip can be fabricated in less than 30 min including patterning, etching and sealing steps. This fabrication process is faster and easier than the thermal bonding process. Besides, the proposed method does not require high temperatures and provides excellent day-to-day and device-to-device repeatability.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A variety of substrates have been used for fabrication of microchips for DNA extraction, PCR amplification, and DNA fragment separation, including the more conventional glass and silicon as well as alternative polymer-based materials. Polyester represents one such polymer, and the laser-printing of toner onto polyester films has been shown to be effective for generating polyester-toner (PeT) microfluidic devices with channel depths on the order of tens of micrometers. Here, we describe a novel and simple process that allows for the production of multilayer, high aspect-ratio PeT microdevices with substantially larger channel depths. This innovative process utilizes a CO(2) laser to create the microchannel in polyester sheets containing a uniform layer of printed toner, and multilayer devices can easily be constructed by sandwiching the channel layer between uncoated cover sheets of polyester containing precut access holes. The process allows the fabrication of deep channels, with similar to 270 mu m, and we demonstrate the effectiveness of multilayer PeT microchips for dynamic solid phase extraction (dSPE) and PCR amplification. With the former, we found that (i) more than 65% of DNA from 0.6 mu L of blood was recovered, (ii) the resultant DNA was concentrated to greater than 3 ng/mu L., (which was better than other chip-based extraction methods), and (iii) the DNA recovered was compatible with downstream microchip-based PCR amplification. Illustrative of the compatibility of PeT microchips with the PCR process, the successful amplification of a 520 bp fragment of lambda-phage DNA in a conventional thermocycler is shown. The ability to handle the diverse chemistries associated with DNA purification and extraction is a testimony to the potential utility of PeT microchips beyond separations and presents a promising new disposable platform for genetic analysis that is low cost and easy to fabricate.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper compares the analytical performance of microchannels fabricated in PDMS, glass, and polyester-toner for electrophoretic separations. Glass and PDMS chips were fabricated using well-established photolithographic and replica-molding procedures, respectively. PDMS channels were sealed against three different types of materials: native PDMS, plasma-oxidized PDMS, and glass. Polyester-toner chips were micromachined by a direct-printing process using an office laser printer. All microchannels were fabricated with similar dimensions according to the limitations of the direct-printing process (width/depth 150 mu m/12 mu m). LIF was employed for detection to rule out any losses in separation efficiency due to the detector configuration. Two fluorescent dyes, coumarin and fluorescein, were used as model analytes. Devices were evaluated for the following parameters related to electrophoretic separations: EOF, heat dissipation, injection reproducibility, separation efficiency, and adsorption to channel wall.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

The analytical determination of atmospheric pollutants still presents challenges due to the low-level concentrations (frequently in the mu g m(-3) range) and their variations with sampling site and time In this work a capillary membrane diffusion scrubber (CMDS) was scaled down to match with capillary electrophoresis (CE) a quick separation technique that requires nothing more than some nanoliters of sample and when combined with capacitively coupled contactless conductometric detection (C(4)D) is particularly favorable for ionic species that do not absorb in the UV-vis region like the target analytes formaldehyde formic acid acetic acid and ammonium The CMDS was coaxially assembled inside a PTFE tube and fed with acceptor phase (deionized water for species with a high Henry s constant such as formaldehyde and carboxylic acids or acidic solution for ammonia sampling with equilibrium displacement to the non-volatile ammonium ion) at a low flow rate (8 3 nLs(-1)) while the sample was aspirated through the annular gap of the concentric tubes at 25 mLs(-1) A second unit in all similar to the CMDS was operated as a capillary membrane diffusion emitter (CMDE) generating a gas flow with know concentrations of ammonia for the evaluation of the CMDS The fluids of the system were driven with inexpensive aquarium air pumps and the collected samples were stored in vials cooled by a Peltier element Complete protocols were developed for the analysis in air of NH(3) CH(3)COOH HCOOH and with a derivatization setup CH(2)O by associating the CMDS collection with the determination by CE-C(4)D The ammonia concentrations obtained by electrophoresis were checked against the reference spectrophotometric method based on Berthelot s reaction Sensitivity enhancements of this reference method were achieved by using a modified Berthelot reaction solenoid micro-pumps for liquid propulsion and a long optical path cell based on a liquid core waveguide (LCW) All techniques and methods of this work are in line with the green analytical chemistry trends (C) 2010 Elsevier B V All rights reserved