43 resultados para Magnetic Resonance Imaging Magnet

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: Adults with major depressive disorder (MDD) are reported to have reduced orbitofrontal cortex (OFC) volumes, which could be related to decreased neuronal density. We conducted a study on medication naive children with MDD to determine whether abnormalities of OFC are present early in the illness course. Methods: Twenty seven medication naive pediatric Diagnostic and Statistical Manual of Mental Disorders, 4(th) edition (DSM-IV) MDD patients (mean age +/- SD = 14.4 +/- 2.2 years; 10 males) and 26 healthy controls (mean age +/- SD = 14.4 +/- 2.4 years; 12 males) underwent a 1.5T magnetic resonance imaging (MRI) with 3D spoiled gradient recalled acquisition. The OFC volumes were compared using analysis of covariance with age, gender, and total brain volume as covariates. Results: There was no significant difference in either total OFC volume or total gray matter OFC volume between MDD patients and healthy controls. Exploratory analysis revealed that patients had unexpectedly larger total right lateral (F = 4.2, df = 1, 48, p = 0.05) and right lateral gray matter (F = 4.6, df = 1, 48, p = 0.04) OFC volumes compared to healthy controls, but this finding was not significant following statistical correction for multiple comparisons. No other OFC subregions showed a significant difference. Conclusions: The lack of OFC volume abnormalities in pediatric MDD patients suggests the abnormalities previously reported for adults may develop later in life as a result of neural cell loss.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To evaluate patellar kinematics of volunteers Without knee pain at rest and during isometric contraction in open- and closed-kinetic-chain exercises. Methods: Twenty individuals took part in this study. All were submitted to magnetic resonance imaging (MRI) during rest and voluntary isometric contraction (VIC) in the open anti closed kinetic chain at 15 degrees, 30 degrees, and 45 degrees of knee flexion. Through MRI and using medical e-film software, the following measurements were evaluated: sulcus angle, patellar-tilt angle, and bisect offset. The mixed-effects linear model was used for comparison between knee positions, between rest and isometric contractions, and between (he exercises. Results: Data analysis revealed that the sulcus angle decreased as knee flexion increased and revealed increases with isometric contractions in both the open and closed kinetic chain for all knee-flexion angles. The patellar-tilt angle decreased with isometric contractions in both the open and closed kinetic chain for every knee position. However, in the closed kinetic chain, patellar tilt increased significantly with the knee flexed at 15 degrees. The bisect offset increased with the knee flexed at 15 degrees during isometric contractions and decreased as knee flexion increased during both exercises. Conclusion: VIC in the last degrees of knee extension may compromise patellar dynamics. On the other hand, it is possible to favor patellar stability by performing muscle contractions with the knee flexed at 30 degrees and 45 degrees in either the open or closed kinetic chain.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Study design: Evaluation of knees of tetraplegic patients who have been walking for several months with the aid of a system that involves neuromuscular stimulation, treadmill and a harness support device. Objectives: To investigate if the training program could cause knee injury to tetraplegic patients. Setting: Hospital das Clinicas - UNICAMP. Campinas-SP, Brazil. Methods: Nine patients were evaluated. Clinical exam and magnetic resonance images (MRIs) were used for evaluation. MRIs were taken before and after the training program, in a 6-month interval for each patient. There were two sessions of training every week. Each session lasted 20 min. Results: No severe clinical abnormality was observed in any patient. Mild knee injury was observed in four of nine patients studied. Conclusions: Tetraplegic patients undergoing treadmill gait training deserve a close follow-up to prevent knee injury.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives We sought to determine whether the quantitative assessment of myocardial fibrosis (MF), either by histopathology or by contrast-enhanced magnetic resonance imaging (ce-MRI), could help predict long-term survival after aortic valve replacement. Background Severe aortic valve disease is characterized by progressive accumulation of interstitial MF. Methods Fifty-four patients scheduled to undergo aortic valve replacement were examined by ce-MRI. Delayed-enhanced images were used for the quantitative assessment of MF. In addition, interstitial MF was quantified by histological analysis of myocardial samples obtained during open-heart surgery and stained with picrosirius red. The ce-MRI study was repeated 27 +/- 22 months after surgery to assess left ventricular functional improvement, and all patients were followed for 52 +/- 17 months to evaluate long-term survival. Results There was a good correlation between the amount of MF measured by histopathology and by ce-MRI (r = 0.69, p < 0.001). In addition, the amount of MF demonstrated a significant inverse correlation with the degree of left ventricular functional improvement after surgery (r = -0.42, p = 0.04 for histopathology; r = -0.47, p = 0.02 for ce-MRI). Kaplan-Meier analyses revealed that higher degrees of MF accumulation were associated with worse long-term survival (chi-square = 6.32, p = 0.01 for histopathology; chi-square = 5.85, p = 0.02 for ce-MRI). On multivariate Cox regression analyses, patient age and the amount of MF were found to be independent predictors of all-cause mortality. Conclusions The amount of MF, either by histopathology or by ce-MRI, is associated with the degree of left ventricular functional improvement and all-cause mortality late after aortic valve replacement in patients with severe aortic valve disease. (J Am Coll Cardiol 2010; 56: 278-87) (c) 2010 by the American College of Cardiology Foundation

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To evaluate the risk of geographic miss associated with the classic four-field ""box"" irradiation technique and to define the variables that predict this risk. Materials and Methods: The study population consisted of 80 patients with uterine cervix cancer seen between 2001 and 2006. Median age was 55 years (23-82 years), and 72 (90%) presented with squamous cell carcinoma. Most patients (68.7%) presented with locally advanced disease (IIb or more). Magnetic resonance imaging findings from before treatment were compared with findings from simulation of the conventional four-field ""box"" technique done with rectal contrast. Study variables included tumor volume; involvement of vagina, parametrium, bladder, or rectum; posterior displacement of the anterior rectal wall; and tumor anteroposterior diameter (APD). Margins were considered adequate when the target volume (primary tumor extension, whole uterine body, and parametrium) was included within the field limits and were at least 1 cm in width. Results: Field limits were inadequate in 45 (56%) patients: 29 (36%) patients at the anterior and 28 (35%) at the posterior border of the lateral fields. Of these, 12 patients had both anterior and posterior miss, and this risk was observed in all stages of the disease (p = 0.076). Posterior displacement of the anterior rectal wall beyond S2-S3 was significantly correlated with the risk of geographic miss (p = 0.043). Larger tumors (APD 6 cm or above and volume above 50 cm(3)) were also significantly correlated with this risk (p = 0.004 and p = 0.046, respectively). Conclusions: Posterior displacement of the anterior rectal wall, tumor APD, and volume can be used as guidance in evaluating the risk of geographic miss. (C) 2009 Elsevier Inc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Real time three-dimensional echocardiography (RT3DE) has been demonstrated to be an accurate technique to quantify left ventricular (LV) volumes and function in different patient populations. We sought to determine the value of RT3DE for evaluating patients with hypertrophic cardiomyopathy (HCM), in comparison with cardiac magnetic resonance imaging (MRI). Methods: We studied 20 consecutive patients with HCM who underwent two-dimensional echocardiography (2DE), RT3DE, and MRI. Parameters analyzed by echocardiography and MRI included: wall thickness, LV volumes, ejection fraction (LVEF), mass, geometric index, and dyssynchrony index. Statistical analysis was performed by Lin agreement coefficient, Pearson linear correlation and Bland-Altman model. Results: There was excellent agreement between 2DE and RT3DE (Rc = 0.92), 2DE and MRI (Rc = 0.85), and RT3DE and MRI (Rc = 0.90) for linear measurements. Agreement indexes for LV end-diastolic and end-systolic volumes were Rc = 0.91 and Rc = 0.91 between 2DE and RT3DE, Rc = 0.94 and Rc = 0.95 between RT3DE and MRI, and Rc = 0.89 and Rc = 0.88 between 2DE and MRI, respectively. Satisfactory agreement was observed between 2DE and RT3DE (Rc = 0.75), RT3DE and MRI (Rc = 0.83), and 2DE and MRI (Rc = 0.73) for determining LVEF, with a mild underestimation of LVEF by 2DE, and smaller variability between RT3DE and MRI. Regarding LV mass, excellent agreement was observed between RT3DE and MRI (Rc = 0.96), with bias of -6.3 g (limits of concordance = 42.22 to -54.73 g). Conclusion: In patients with HCM, RT3DE demonstrated superior performance than 2DE for the evaluation of myocardial hypertrophy, LV volumes, LVEF, and LV mass.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To compare clinical evaluation, electrophysiological investigation and magnetic resonance findings in assessing the severity of idiopathic carpal tunnel syndrome. Patients and methods: Seventy-four patients with idiopathic carpal tunnel syndrome were prospectively recruited. Clinical evaluation included symptoms severity score and two-point discrimination, sensory and motor nerve conduction velocities were determined by electroneuromyography and imaging parameters were obtained after wrist magnetic resonance. The Wilcoxon test was used to define the differences between measurements of median nerve area. The Pearson and Spearman correlation tests were used to determine the relationships between all the measured parameters. Results: Cross-sectional area of median nerve was smaller at hamate level than at radio-ulnar joint and pisiform levels (p < 0.001). With exception of median nerve area at hamate level, there was a lower degree of correlation between MRI parameters and findings obtained by clinical assessments and electrophysiological measurements. The median nerve area at hamate level correlated negatively with duration of symptoms, two-point discrimination, symptoms severity score and positively with sensory nerve conduction velocity (P < 0.01). Conclusion: In patients with idiopathic carpal tunnel syndrome, median nerve area measured by wrist magnetic resonance at hamate level may be considered as a valuable indicator to grading the severity of disease. (c) 2007 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: The purpose of this study was to measure the intraobserver and interobserver reliability of magnetic resonance detection of cervical spondylotic myelopathy with and without operational guidelines. Methods: Seven radiologists examined images from 10 patients with cord signal abnormalities and clinical signs of myelopathy. Radiologist examined films twice, with and without operational guidelines designed to define stenotic changes, while blinded to the clinical findings of the patients. Analyses included a Fleiss kappa assessment of intraobserver and interobserver reliability. Results: Results demonstrated high percentage of agreement and strong intraobserver reliability and variable Fleiss kappa, values for interobserver assessment. Operational guidelines did not improve the intraobserver or interobserver agreement. Conclusion: Although the percentage of agreement was high in some cases, the kappa agreement was low-most likely a result of the base rate problem of a kappa analysis. Sample bias toward severe degenerative changes resulted in highly prevalent selections and kappa adjusted values. Nonetheless, the results do suggest that substantial intraobserver kappa agreement and a wide range of interobserver kappa agreement exists among trained radiologists during detection of stenotic changes associated with cervical spondylotic myelopathy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The magnetic resonance imaging contrast agent, the so-called Endorem (TM) colloidal suspension on the basis of superparamagnetic iron oxide nanoparticles (mean diameter of 5.5 nm) coated with dextran, were characterized on the basis of several measurement techniques to determine the parameters of their most important physical and chemical properties. It is assumed that each nanoparticle is consisted of Fe(3)O(4) monodomain and it was observed that its oxidation to gamma-Fe(2)O(3) occurs at 253.1 degrees C. The Mossbauer spectroscopy have shown a superparamagnetic behavior of the magnetic nanoparticles. The Magnetic Resonance results show an increase of the relaxation times T(1), T(2), and T(2)* with decreasing concentration of iron oxide nanoparticles. The relaxation effects of SPIONs contrast agents are influenced by their local concentration as well as the applied field strength and the environment in which these agents interact with surrounding protons. The proton relaxation rates presented a linear behavior with concentration. The measured values of thermooptic coefficient partial derivative n/partial derivative T, thermal conductivity K, optical birefringence Delta n(0), nonlinear refractive index n(2), nonlinear absorption beta` and third-order nonlinear susceptibility vertical bar chi((3))vertical bar are also reported.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Depression is the most frequent psychiatric disorder in Parkinson`s disease (PD). Although evidence Suggests that depression in PD is related to the degenerative process that underlies the disease, further studies are necessary to better understand the neural basis of depression in this population of patients. In order to investigate neuronal alterations underlying the depression in PD, we studied thirty-six patients with idiopathic PD. Twenty of these patients had the diagnosis of major depression disorder and sixteen did not. The two groups were matched for PD motor severity according to Unified Parkinson Disease Rating Scale (UPDRS). First we conducted a functional magnetic resonance imaging (fMRI) using an event-related parametric emotional perception paradigm with test retest design. Our results showed decreased activation in the left mediodorsal (MD) thalamus and in medial prefrontall cortex in PD patients with depression compared to those without depression. Based upon these results and the increased neuron count in MD thalamus found in previous studies, we conducted a region of interest (ROI) guided voxel-based morphometry (VBM) study comparing the thalamic volume. Our results showed an increased volume in mediodorsal thalamic nuclei bilaterally. Converging morphological changes and functional emotional processing in mediodorsal thalamus highlight the importance of limbic thalamus in PD depression. In addition this data supports the link between neurodegenerative alterations and mood regulation. (C) 2009 Elsevier Inc. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background-Endocardial fibrous tissue (FT) deposition is a hallmark of endomyocardial fibrosis (EMF). Echocardiography is a first-line and the standard technique for the diagnosis of this disease. Although late gadolinium enhancement (LGE) cardiovascular magnetic resonance (CMR) allows FT characterization, its role in the diagnosis and prognosis of EMF has not been investigated. Methods and Results-Thirty-six patients (29 women; age, 54 +/- 12 years) with EMF diagnosis after clinical evaluation and comprehensive 2-dimensional Doppler echocardiography underwent cine-CMR for assessing ventricular volumes, ejection fraction and mass, and LGE-CMR for FT characterization and quantification. Indexed FT volume (FT/body surface area) was calculated after planimetry of the 8 to 12 slices obtained in the short-axis view at end-diastole (mL/m(2)). Surgical resection of FT was performed in 16 patients. In all patients, areas of LGE were confined to the endocardium, frequently as a continuous streak from the inflow tract extending to the apex, where it was usually most prominent. There was a relation between increased FT/body surface area and worse New York Heart Association functional class and with increased probability of surgery (P<0.05). The histopathologic examination of resected FT showed typical features of EMF with extensive endocardial fibrous thickening, proliferation of small vessels, and scarce inflammatory infiltrate. In multivariate analysis, the patients with FT/body surface area >19 mL/m(2) had an increased mortality rate, with a relative risk of 10.8. Conclusions-Our study provides evidence that LGE-CMR is useful in the diagnosis and prognosis of EMF through quantification of the typical pattern of FT deposition. (Circ Cardiovasc Imaging. 2011;4:304-311.)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To evaluate the accuracy of preoperative magnetic resonance imaging (MRI) findings relative to surgical presence of deeply infiltrating endometriosis (DIE). Methods: This prospective study included 92 women with clinical suspicion of DIE. The MR images were compared with laparoscopy and pathology findings. Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of MRI for diagnosis of DIE were assessed. Results: DIE was confirmed at histopathology in 77 of the 92 patients (83.7%). Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of MRI to diagnose DIE at each of the specific sites evaluated were as follows: retrocervical space (89.4%, 92.3%, 96.7%, 77.4%, 90.2%); rectosigmoid (86.0%, 92.9%, 93.5%, 84.8%, 89.1%); bladder (23.1%, 100%,100%, 88.8%, 89.1%); ureters (50.0%, 100%, 95.5%, 95.7%); and vagina (72.7%, 100%, 100%, 96.4%, 96.7%). Conclusion: MRI demonstrates high accuracy in diagnosing DIE in the retrocervical region, rectosigmoid. bladder, ureters, and vagina. (C) 2009 International Federation of Gynecology and Obstetrics. Published by Elsevier Ireland Lid. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background. Some neuroimaging studies have supported the hypothesis of progressive brain changes after a first episode of psychosis. We aimed to determine whether (i) first-episode psychosis patients would exhibit more pronounced brain volumetric changes than controls over time and (ii) illness course/treatment would relate to those changes. Method. Longitudinal regional grey matter volume and ventricle : brain ratio differences between 39 patients with first-episode psychosis (including schizophrenia and schizophreniform disorder) and 52 non-psychotic controls enrolled in a population-based case-control study. Results. While there was no longitudinal difference in ventricle : brain ratios between first-episode psychosis subjects and controls, patients exhibited grey matter volume changes, indicating a reversible course in the superior temporal cortex and hippocampus compared with controls. A remitting course was related to reversal of baseline temporal grey matter deficits. Conclusions. Our findings do not support the hypothesis of brain changes indicating a progressive course in the initial phase of psychosis. Rather, some brain volume abnormalities may be reversible, possibly associated with a better illness course.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Carotid artery stenosis due to arteriosclerosis increases the risk of cerebral ischemia via embolic phenomena or reduced blood flow. The changes in cerebral perfusion that may occur after treatment are not clearly understood. This study evaluated the changes in cerebral microcirculation following carotid angioplasty with stenting (CAS) under cerebral protection with filters using ultrafast gradient echo (GRE) perfusion weighted imaging (PWI) with magnetic resonance imaging (MRI). Prospectively, 21 cervical carotid stenosis patients, mean age 69.95 years, underwent MRI 12 h before and 72 h after CAS. PWI parameters were collected for statistical analysis: cerebral blood volume (CB V), mean transit time (MTT) and time to peak (TTP). Statistical analysis was applied to absolute parameters and to values normalized against those from the contralateral parenchyma. The main finding of this study was improved hemodynamics for the normalized data after CAS, shown by reduced MTT (p<0.001) and TTP (p=0.019) in the territory fed by the middle cerebral artery ipsilateral to the CAS. Absolute data showed increased blood volume in the cerebral hemispheres after CAS, which was more accentuated on the stent side (p=0.016) than the contralateral side (p=0.029). Early improvements in cerebral perfusion, mainly seen in the normalized data, were clearly demonstrated in the timing parameters - TTP & MTT - after CAS.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background Chronic aortic valve disease (AVD) is characterized by progressive accumulation of interstitial myocardial fibrosis (MF). However, assessment of MF accumulation has only been possible through histologic analyses of endomyocardial biopsies. We sought to evaluate contrast-enhanced magnetic resonance imaging (ce-MRI) as a noninvasive method to identify the presence of increased MF in patients with severe AVD. Methods Seventy patients scheduled to undergo aortic valve replacement surgery were examined by cine and ce-MRI in a 1.5-T scanner. Cine images were used for the assessment of left ventricular (LV) volumes, mass, and function. Delayed-enhancement images were used to characterize the regions of MF. In addition, histologic analyses of myocardial samples obtained during aortic valve replacement surgery were used for direct quantification of interstitial MF. Ten additional subjects who died of noncardiac causes served as controls for the quantitative histologic analyses. Results Interstitial MF determined by histopathologic analysis was higher in patients with AVID than in controls (2.7% +/- 2.0% vs 0.6% +/- 0.2%, P =.001). When compared with histopathologic results, ce-MRI demonstrated a sensitivity of 74%, a specificity of 81%, and an accuracy of 76% to identify AVD patients with increased interstitial MF There was a significant inverse correlation between interstitial MF and LV ejection fraction (r = -0.67, P <.0001). Accordingly, patients with identifiable focal regions of MF by ce-MRI exhibited worse LV systolic function than those without MF (45% +/- 14% vs 65% +/- 14%, P <.0001). Conclusions Contrast-enhanced MRI allows for the noninvasive detection of focal regions of MF in patients with severe AVD. Moreover, patients with identifiable MF by ce-MRI exhibited worse LV functional parameters. (Am Heart J 2009; 157:361-8.)