4 resultados para MRT,voxel-dosimetry,terapia radiometabolica

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this paper is to report the sensitization of the TL peak appearing at 270 degrees C in the glow curve of natural quartz by using the combined effect of heat-treatments and irradiation with high gamma doses. For this, thirty discs with 6 x 1 mm(2) were prepared from plates parallell to a rhombolledral crystal face. The specimens were separated into four lots according to its TL read out between 160 and 320 degrees C. One lot was submitted to gamma doses of Co-60 radiation starting at 2 kGy and going up until a cumulative dose of 25 kGy. The other three lots were initially heal-treated at 500, 800 and 1000 degrees C and then irradiated with a single dose of 25kGy. The TL response of each lot was determined as a function of test-doses ranging from 0.1 to 30 mGy. As a result, it was observed that heat-treatments themselves did not produce the strong peak at 270 degrees C that was observed after the administration of high gamma doses. This peak is associated with the optical absorption band appearing at 470 rim which is due to the formation of [AlO4]degrees acting as electron-hole recombination centers. The formation of the 270 degrees C peak was preliminary analyzed in relation to aluminum- and oxygen-vacancy-related centers found in crystalline quartz. (C) 2008 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to validate the Geant4 toolkit for dosimetry applications, simulations were performed to calculate conversion coefficients h(10, alpha) from air kerma free-in-air to personal dose equivalent Hp(10, a). The simulations consisted of two parts: the production of X-rays with radiation qualities of narrow and wide spectra, and the interaction of radiation with ICRU tissue-equivalent and ISO water slab phantoms. The half-value layers of the X-ray spectra obtained by simulation were compared with experimental results. Mean energy, spectral resolution, half-value layers and conversion coefficients were compared with ISO reference values. The good agreement between results from simulation and reference data shows that the Geant4 is suitable for dosimetry applications which involve photons with energies in the range of ten to a few hundreds of keV. (C) 2008 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

After the development of the highly sensitive material Al(2)O(3):C, personal dosimetry using optically stimulated luminescence (OSL) has been continuously adopted in place of thermoluminescence dosimeters (TLD) by different countries (e.g. USA and Japan). In order to use a dosimetric system in Brazil it is necessary to develop a protocol and to fulfill performance and type tests in accordance with the accreditation program approved by the responsible governmental committee. This paper presents a proposal for an accreditation program for OSL personal dosimetry using a commercial dosimetric system, including tests that follow the same rules as applied to TLD and film dosimetry. The experimental results are within the reliability interval and in accordance to the expected behavior. A new test concerning re-analysis of exposed badges is also proposed. (C) 2009 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

One of the major advances in PDT is the use of 5-aminolevulinic acid (ALA) to induce the production of an enclogenous photosensitizer inside the cells using intracellular enzymatic pathways. ALA is the first intermediate in heme biosynthesis and a precursor of the protoporphyrin IX (PpIX). When activated by light, this efficient photosensitizer accumulated in the target cells can produce cytotoxicity. The aim of this study was to find the best conditions for cell killing using ALA to temporarily increase the concentration of PpIX in two cell lines. It was shown that a considerable efflux of synthesized PpIX occurs. Since this efflux is time-dependent, it is essential to know the optimum time for irradiation after ALA administration. So, the efflux of PpIX from the cells is an important parameter to be considered for ALA-PDT dosimetry.