13 resultados para MILLIMETER

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this in vitro study was to evaluate the tensile bond strength of a self-etching adhesive system to three different dentinal substrates. Primary molar teeth that had been recently exfoliated (RE), with unknown time of exfoliation (UT), and extracted due to prolonged retention (PR) were used for this investigation. Ten primary molar teeth of each group were cut in the middle following the mesio-distal direction, creating a total of twenty specimens per group. The specimens were included in acrylic resin and had a flat dentin surface exposed. The self-etching adhesive system was applied to this surface and a 3-millimeter high cone with diameter of 2 mm in the adhesion area was constructed using composite resin. The specimens were stored in distilled water at 37ºC for 24 hours. Fifteen specimens of each substrate were used for the tensile bond test (n = 15) and 5 had the interface analyzed by scanning electron microscopy (SEM). The data was examined by one-way ANOVA and presented no significant differences between groups (p = 0.5787). The mean values obtained for RE, UT and PR were 18.39 ± 9.70, 19.41 ± 7.80, and 23.30 ± 9.37 MPa, respectively. Any dentinal substrates of primary teeth studied are safe for tensile bond strength tests with adhesive systems.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O período inicial da gestação de bovinos é caracterizado por grandes perdas embrionárias. Considerando a importância deste fator no âmbito da reprodução animal foram estudados os anexos embrionários e fetais bovinos fecundados por monta natural de 15-70 dias de gestação, com o objetivo de estabelecer parâmetros morfométricos da placenta na fase inicial da gestação. Com uso de um paquímetro foram realizadas mensurações do comprimento (crânio caudal), largura (latero lateral) e altura (dorso ventral) das membranas corioalantóide e amniótica. O início da formação dos cotilédones foi observado e quantificado, assim como, o peso placentário. O peso médio do saco gestacional aumentou com o evoluir da idade gestacional, entretanto, o crescimento foi acelerado a partir de 20-30 dias de gestação. O comprimento crânio caudal e dorso ventral da membrana corioalantóide e do âmnio apresentaram crescimento lento e gradual com o evoluir dos períodos gestacionais analisados. Com 30-40 dias de gestação, os primeiro cotilédones já eram visualizados e contatos com facilidade na superfície coriônica. Os períodos de crescimento coincidiram com os maiores índices de perdas gestacionais em bovinos. Os parâmetros aqui analisados poderão servir para futuras investigações dos anexos embrionários de organismos manipulados em laboratório.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work is part of a research under construction since 2000, in which the main objective is to measure small dynamic displacements by using L1 GPS receivers. A very sensible way to detect millimetric periodic displacements is based on the Phase Residual Method (PRM). This method is based on the frequency domain analysis of the phase residuals resulted from the L1 double difference static data processing of two satellites in almost orthogonal elevation angle. In this article, it is proposed to obtain the phase residuals directly from the raw phase observable collected in a short baseline during a limited time span, in lieu of obtaining the residual data file from regular GPS processing programs which not always allow the choice of the aimed satellites. In order to improve the ability to detect millimetric oscillations, two filtering techniques are introduced. One is auto-correlation which reduces the phase noise with random time behavior. The other is the running mean to separate low frequency from the high frequency phase sources. Two trials have been carried out to verify the proposed method and filtering techniques. One simulates a 2.5 millimeter vertical antenna displacement and the second uses the GPS data collected during a bridge load test. The results have shown a good consistency to detect millimetric oscillations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We consider a model where sterile neutrinos can propagate in a large compactified extra dimension giving rise to Kaluza-Klein (KK) modes and the standard model left-handed neutrinos are confined to a 4-dimensional spacetime brane. The KK modes mix with the standard neutrinos modifying their oscillation pattern. We examine former and current experiments such as CHOOZ, KamLAND, and MINOS to estimate the impact of the possible presence of such KK modes on the determination of the neutrino oscillation parameters and simultaneously obtain limits on the size of the largest extra dimension. We found that the presence of the KK modes does not essentially improve the quality of the fit compared to the case of the standard oscillation. By combining the results from CHOOZ, KamLAND, and MINOS, in the limit of a vanishing lightest neutrino mass, we obtain the stronger bound on the size of the extra dimension as similar to 1.0(0.6) mu m at 99% C.L. for normal (inverted) mass hierarchy. If the lightest neutrino mass turns out to be larger, 0.2 eV, for example, we obtain the bound similar to 0.1 mu m. We also discuss the expected sensitivities on the size of the extra dimension for future experiments such as Double CHOOZ, T2K, and NO nu A.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work, we study the emission of tensor-type gravitational degrees of freedom from a higher-dimensional, simply rotating black hole in the bulk. The decoupled radial part of the corresponding field equation is first solved analytically in the limit of low-energy emitted particles and low-angular momentum of the black hole in order to derive the absorption probability. Both the angular and radial equations are then solved numerically, and the comparison of the analytical and numerical results shows a very good agreement in the low and intermediate energy regimes. By using our exact, numerical results we compute the energy and angular-momentum emission rates and their dependence on the spacetime parameters such as the number of additional spacelike dimensions and the angular momentum of the black hole. Particular care is given to the convergence of our results in terms of the number of modes taken into account in the calculation and the multiplicity of graviton tensor modes that correspond to the same angular-momentum numbers.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We study the stability of AdS black holes rotating in a single two-plane for tensor-type gravitational perturbations in D > 6 space-time dimensions. First, by an analytic method, we show that there exists no unstable mode when the magnitude a of the angular momentum is smaller than r(h)(2)/R, where r(h) is the horizon radius and R is the AdS curvature radius. Then, by numerical calculations of quasinormal modes, using the separability of the relevant perturbation equations, we show that an instability occurs for rapidly rotating black holes with a > r(h)(2)/R, although the growth rate is tiny (of order 10(-12) of the inverse horizon radius). We give numerical evidence indicating that this instability is caused by superradiance.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We study the massless scalar, Dirac, and electromagnetic fields propagating on a 4D-brane, which is embedded in higher-dimensional Gauss-Bonnet space-time. We calculate, in the time domain, the fundamental quasinormal modes of a spherically symmetric black hole for such fields. Using WKB approximation we study quasinormal modes in the large multipole limit. We observe also a universal behavior, independent on a field and value of the Gauss-Bonnet parameter, at an asymptotically late time.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The squashed Kaluza-Klien (KK) black holes differ from the Schwarzschild black holes with asymptotic flatness or the black strings even at energies for which the KK modes are not excited yet, so that squashed KK black holes open a window in higher dimensions. Another important feature is that the squashed KK black holes are apparently stable and, thereby, let us avoid the Gregory-Laflamme instability. In the present paper, the evolution of scalar and gravitational perturbations in time and frequency domains is considered for these squashed KK black holes. The scalar field perturbations are analyzed for general rotating squashed KK black holes. Gravitational perturbations for the so-called zero mode are shown to be decayed for nonrotating black holes, in concordance with the stability of the squashed KK black holes. The correlation of quasinormal frequencies with the size of extra dimension is discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Alumina ceramics with high in-line transmittance at 0.5-1.0 mm-thickness were prepared with different doping additives by sintering at 1850 degrees C in vacuum for 1-8 h. Depending on the additive contents and sintering variables bi-dimensionally large surface grains, caused by surface evaporation of MgO, had grown parallel to the surface with similar to 100 mu m thickness and lateral sizes up to the millimeter range. The abnormal grain-growth process also resulted in the formation of pores entrapped inside the large surface grains within a narrow zone at 10-20 mu m distance from the surface. The fraction of these pores is thickness-invariant. Scattering factors associated to the pores entrapped inside the bi-dimensionally large surface grains, second-phase particles, grain-boundaries, and microstructural surface defects are derived from the results of in-line transmission (at 600 nm) and are used together with microstructural characteristics to explain the light transmittance in these materials. (C) 2008 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background and objectives: As well as being a marker of body iron stores, serum ferritin (sFerritin) has also been shown to be a marker of inflammation in hemodialysis (HD) patients. The aim of this study was to analyze whether sFerritin is a reliable marker of the iron stores present in bone marrow of HD patients. Design: Histomorphometric analysis of stored transiliac bone biopsies was used to assess iron stores by determining the number of iron-stained cells per square millimeter of bone marrow. Results: In 96 patients, the laboratory parameters were hemoglobin = 11.3 +/- 1.6 g/dl, hematocrit = 34.3 +/- 5%, sFerritin 609 +/- 305 ng/ml, transferrin saturation = 32.7 +/- 22.5%, and C-reactive protein (CRP) = 0.9 +/- 1.4 mg/dl. sFerritin correlated significantly with CRP, bone marrow iron, and time on HD treatment W = 0.006, 0.001, and 0.048, respectively). The independent determinants of sFerritin were CRP (beta-coef = 0.26; 95% CI = 24.6 to 132.3) and bone marrow iron (beta-coef = 0.32; 95% CI = 0.54 to 2.09). Bone marrow iron was higher in patients with sFerritin >500 ng/ml than in those with sFerritin :5500 ng/ml. In the group of patients with sFerritin :5500 ng/ml, the independent determinant of sFerritin was bone marrow iron (beta-coef = 0.48, 95% CI = 0.48 to 1.78), but in the group of patients with sFerritin >500 ng/ml, no independent determinant of sFerritin was found. Conclusions: sFerritin adequately reflects iron stores in bone marrow of HD patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: The high incidence of respiratory disorders is one of the main problems in perinatal medical care. With the increased use of intubation, the incidence of laryngeal injury causing stenosis has also increased. The principal constriction point in the infant`s larynx is the midcricoid area. We sought to provide detailed morphometric data on the anatomy of the cricoid cartilage and its relationship with growth and body characteristics of fetuses at 5 to 9 months of gestational age. Methods: Nineteen larynges obtained from 17 stillborn infants and 2 newborn infants ranging in gestational age from 5 to 9 months were studied. Measurements of the cricoid cartilage were made with a millimeter-graded caliper. Results: Weight was the variable most correlated with cricoid measurements. The cricoid lumen configuration showed an almost elliptic shape and did not change with gestational age. The mean inner subglottic cricoid area was 19.27 +/- 9.62 mm(2) and was related to weight and body surface area. Cricoid growth was more pronounced at the outer portion of the cartilage. Conclusions: The cricoid lumen configuration was elliptic, and its mean area was smaller than that of available endotracheal tubes. This lumen area was most influenced by weight and height.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: This study compared the combined use of sodium hypochlorite (NaOCl) and chlorhexidine (CXH) with citric acid and CXH on dentinal permeability and precipitate formation. Methods: Thirty-four upper anterior teeth were prepared by rotary instrumentation and NaOCl. The root canal surfaces were conditioned for smear layer removal using 15% citric acid solution under ultrasonic activation and a final wash with distilled water. All teeth were dried, and 30 specimens were randomly divided into three equal groups as follows: positive control group (PC), no irrigation; 15% citric acid + 2% CHX group (CA + CHX); and 1% NaOCl + 2% CHX group (NaOCl + CHX). All roots were immersed in a 0.2% Rhodamine B solution for 24 hours. One-millimeter-thick slices from the cementum-enamel junction were scanned at 400 dpi and analyzed using the software ImageLab (LIDO-USP, Sao Paulo, Brazil) for the assessment of leakage in percentage. For scanning electron microscopy analysis, four teeth, irrigated for NaOCl + CHX samples, were split in half, and each third was evaluated at 1,000x and 5,000x (at the precipitate). Results: Using the analysis of variance test followed by the Bonferroni comparison method, no statistical differences between groups were found when analyzed at the cervical and medium thirds. At the apical third, differences between the PC and NaOCl + CHX (p<0.05) and CA + CHX and NaOCl + CHX could be seen (p < 0.05). Conclusion: The combination of 1% NaOCl and 2% CHX solutions results in the formation of a flocculate precipitate that acts as a chemical smear layer reducing the dentinal permeability in the apical third. (J Endod 2010;36:847-850)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective. To evaluate the influence of shaft design on the shaping ability of 3 rotary nickel-titanium (NiTi) systems. Study design. Sixty curved mesial canals of mandibular molars were used. Specimens were scanned by spiral tomography before and after canal preparation using ProTaper, ProFile, and ProSystem GT rotary instruments. One-millimeter-thick slices were scanned from the apical end point to the pulp chamber. The cross-sectional images from the slices taken earlier and after canal preparation at the apical, coronal, and midroot levels were compared. Results. The mean working time was 137.22 +/- 5.15 s. Mean transportation, mean centering ratio, and percentage of area increase were 0.022 +/- 0.131 mm, 0.21 +/- 0.11, and 76.90 +/- 42.27%, respectively, with no statistical differences (P > .05). Conclusions. All instruments were able to shape curved mesial canals in mandibular molars to size 30 without significant errors. The differences in shaft designs seemed not to affect their shaping capabilities.