6 resultados para Low-temperature plasma
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)
Resumo:
In Leishmania, arginase is responsible for the production of ornithine, a precursor of polyamines required for proliferation of the parasite. In this work, the activation kinetics of immobilized arginase enzyme from L. (L.) amazonensis were studied by varying the concentration of Mn(2+) applied to the nickel column at 23 degrees C. The intensity of the binding of the enzyme to the Ni(2+) resin was directly proportional to the concentration of Mn(2+). Conformational changes of the enzyme may occur when the enzyme interacts with immobilized Ni(2+), allowing the following to occur: (1) entrance of Mn(2+) and formation of the metal bridge; (2) stabilization and activation of the enzyme at 23 degrees C; and (3) an increase in the affinity of the enzyme to Ni(2+) after the Mn(2+) activation step. The conformational alterations can be summarized as follows: the interaction with the Ni(2+) simulates thermal heating in the artificial activation by opening a channel for Mn(2+) to enter. (C) 2010 Elsevier Inc. All rights reserved.
Resumo:
Free-living bacteria must respond to a wide range of temperature changes, and have developed specific mechanisms to survive in extreme environments. In this work we describe a remarkable resistance of mesophilic bacterium Caulobacter crescentus to several cycles of freezing at -80 degrees C, which was able to grow at low temperatures. Exponentially growing cells and late stationary-phase cells presented higher freezing resistance at both -20 and -80 degrees C than early stationary-phase cells. Cryotolerance was observed when log-phase cultures grown at 30 degrees C were preincubated at 5, 15 or 20 degrees C before freezing at -20 degrees C. A transposon library was screened to identify mutants sensitive to freezing at -80 degrees C and three strains presenting < 10% survival were isolated. Identification of genes disrupted in each mutant showed that they encoded an AddA family DNA helicase, a DEAD/DEAH box RNA helicase and a putative RND (resistance, nodulation, cell division) efflux system component. These strains showed longer generation times than wild-type cells when growing at 15 degrees C, with the RNA helicase mutant presenting a severe growth defect. These analyses suggest that the singular intrinsic resistance to freezing of C. crescentus is in fact a consequence of several independent traits, especially the maintenance of a proper degree of supercoiling of nucleic acids.
Resumo:
This paper describes an investigation on CuO and CuO-ZnO catalysts supported on CeO(2) and CeO(2)-La(2)O(3) oxides, which were designed for the low temperature water-gas shift reaction (WGSR). Bulk catalysts were prepared by co-precipitation of metal nitrates and characterized by energy-dispersive spectroscopy (EDS), X-ray diffraction (XRD), surface area (by the BET method), X-ray photoelectron spectroscopy (XPS), and in situ X-ray absorption near edge structure (XANES). The catalysts` activities were tested in the forward WGSR, and the CuO/CeO(2) catalyst presented the best catalytic performance. The reasons for this are twofold: (1) the presence of Zn inhibits the interaction between Cu and Ce ions, and (2) lanthanum oxide forms a solid solution with cerium oxide, which will cause a decrease in the surface area of the catalysts. Also the CuO/CeO(2) catalyst presented the highest Cu content on the surface, which could influence its catalytic behavior. Additionally, the Cu and Cu(1+) species could influence the catalytic activity via a reduction-oxidation mechanism, corroborating to the best catalytic performance of the Cu/Ce catalyst. (c) 2010 Elsevier B.V. All rights reserved.
Resumo:
Anisotropy of thermal stresses in confined dusty plasmas is considered. It is shown that in a multi-component low-temperature plasma containing electrons, ions and dust, the complicated dependence of the ion viscosity on ion temperature gradients leads to a plasma equilibrium state with anisotropic pressure. This pressure anisotropy can be of the order of the ion pressure in some limiting cases, in which the ion Larmor radius or the ion mean free path are of the order of the characteristic length of the plasma nonuniformity. For a sufficiently large dust number density, they contribute to the plasma pressure anisotropy and to its spatial dependence. Currently, it is not yet clear whether this equilibrium state is stable or not. Under these conditions, some convective plasma flows can arise in confinement devices. Therefore, this question needs special consideration.
Resumo:
The aim of this study was to verify and describe the presence of microorganisms in the single-use trocar after its use in surgical procedures, and after this device was submitted to cleaning, conditioning, and sterilization by physicochemical processes (formaldehyde, ethylene oxide, and hydrogen peroxide plasma). Twenty-eight trocars of the Ethicon, Auto-suture, and Aesculap brands, were randomly selected and analyzed after laparoscopic cholecystectomy. The results have shown that cultures grown of the material collected from the trocars, immediately after its use and before its sterilization process, showed the presence of bacteria and fungi in 46.5% (13). In 53.5% (15) of the trocars, the presence of microorganisms was not detected, very likely due to niche`s scarcity. In the cultures grown of the 28 trocars after being submitted to sterilization processes, the presence of microorganisms was not verified. We can therefore conclude that although trocars possess compartments not easily accessed for cleaning, these devices can be adequately cleaned and effectively sterilized, when well manipulated, in the institution where the study was carried out by the processes of steam sterilization at low temperature and formaldehyde, ethylene oxide, and hydrogen peroxide plasma.
Resumo:
We report the design and operation of a device for ac magnetic susceptibility measurements that can operate down to 1 mK. The device, a modification of the standard mutual inductance bridge, is designed with detailed consideration of the thermalization and optimization of each element. First, in order to reduce local heating, the primary coil is made with superconducting wire. Second, a low-temperature transformer which is thermally anchored to the mixing chamber of a dilution refrigerator, is used to match the output of the secondary coil to a high-sensitivity bridge detector. The careful thermal anchoring of the secondary coil and the matching transformer is required to reduce the overall noise temperature and maximize sensitivity. The sample is immersed in liquid (3)He to minimize the Kapitza thermal resistance. The magnetic susceptibility of several magnetic compounds, such as the well-known spin gap compound NiCl(2)-4SC(NH(2))(2) and other powdered samples, have been successfully measured to temperatures well below 10 mK.