15 resultados para L33 - Comparison of Public and Private Enterprises
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)
Resumo:
This study evaluated the color stability, surface roughness and flexural strength of a microwave-polymerized acrylic resin after immersion in sodium hypochlorite (NaOCl), simulating 20 min of disinfection daily during 180 days. Forty disk-shaped (15 x 4 mm) and 40 rectangular (65 x 10 x 3 mm) specimens were prepared with a microwave-polymerized acrylic resin (Onda-Cryl). Specimens were immersed in either 0.5% NaOCl, 1% NaOCl, Clorox/Calgon and distilled water (control). Color measurements were determined by a portable colorimeter. Three parallel lines, separated by 1.0 mm, were registered on each specimen before and after immersion procedures to analyze the surface roughness. The flexural strength was measured using a 3-point bending test in a universal testing machine with a 50 kgf load cell and a crosshead speed of 1 mm/min. Data were analyzed statistically by ANOVA and Tukey's test (?=0.05). There was no statistically significant differences (p>0.05) among the solutions for color, surface roughness and flexural strength. It may be concluded that immersion in NaOCl solutions simulating short-term daily use during 180 days did not influence the color stability, surface roughness and flexural strength of a microwave-polymerized acrylic resin.
Resumo:
This study aimed at comparing amounts of nickel (Ni) and chromium (Cr) released from brackets from different manufacturers in simulated oral environments. 280 brackets were equally divided into 7 groups according to manufacturer. 6 groups of brackets were stainless steel, and 1 group of brackets was made of a cobalt-chromium alloy with low Ni content (0.5%). International standard ISO 10271/2001 was applied to provide test methods. Each bracket was immersed in 0.5 ml of synthetic saliva (SS) or artificial plaque fluid (PF) over a period of 28 days at 37ºC. Solutions were replaced every 7 days, and were analyzed by spectrometry. The Kruskal-Wallis test was applied. Amounts of Ni release in SS (µg L-1 per week) varied between groups from "bellow detection limits" to 694, and from 49 to 5,948.5 in PF. The group of brackets made of cobalt-chromium alloy, with the least nickel content, did not release the least amounts of Ni. Amounts of Cr detected in SS and in PF (µg L-1 per week) were from 1 to 10.4 and from 50.5 to 8,225, respectively. It was therefore concluded that brackets from different manufacturers present different corrosion behavior. Further studies are necessary to determine clinical implications of the findings.
Resumo:
It was performed the comparison of the intensity and duration of agglutinating and neutralizing antibodies to serovar Hardjo in swines vaccinated with two commercial anti-leptospira bacterins. Sows no reactive to 24 Leptospira sp serovars in the microscopic agglutination test (MAT) were divided in three groups: Group A (n=08): received two vaccine A doses with 30 days interval, Group B (n=08) two vaccine B doses with 30 days interval and Group C (n=08): control no vaccinated against leptospirosis.Blood samples were collected each 30 days during six months following the first vaccination. The sera were tested by MAT and growth inhibition test (GIT) to serovar Hardjo in order to evaluate respectively agglutinating and neutralizing antibodies. It was found that neutralizing antibodies persisted for a longer time than the agglutinating ones and that the absence of agglutinating antibodies does not means in the absence of the neutralizing. The peaks of agglutinating antibodies was obtained at least 30 days earlier than that produced by neutralizing. The duration of both kinds of antibodies measured differed between the two bacterines tested. The period for inducing neutralizing antibodies against serovar Hardjo indicated that gilts must be immunized with two doses of whole culture anti-leptospira bacterines applied 30 days each other at least 90 days before the first mating. For the maintenance of hight levels of neutralizing antibodies the revaccinations must be performed every six months after the first vaccination.
Resumo:
Vertical number fluxes of aerosol particles and vertical fluxes of CO(2) were measured with the eddy covariance method at the top of a 53 m high tower in the Amazon rain forest as part of the LBA (The Large Scale Biosphere Atmosphere Experiment in Amazonia) experiment. The observed aerosol number fluxes included particles with sizes down to 10 nm in diameter. The measurements were carried out during the wet and dry season in 2008. In this study focus is on the dry season aerosol fluxes, with significant influence from biomass burning, and these are compared with aerosol fluxes measured during the wet season. Net particle deposition fluxes dominated in daytime in both seasons and the deposition flux was considerably larger in the dry season due to the much higher dry season particle concentration. The particle transfer velocity increased linearly with increasing friction velocity in both seasons. The difference in transfer velocity between the two seasons was small, indicating that the seasonal change in aerosol number size distribution is not enough for causing any significant change in deposition velocity. In general, particle transfer velocities in this study are low compared to studies over boreal forests. The reasons are probably the high percentage of accumulation mode particles and the low percentage of nucleation mode particles in the Amazon boundary layer, both in the dry and wet season, and low wind speeds in the tropics compared to the midlatitudes. In the dry season, nocturnal particle fluxes behaved very similar to the nocturnal CO(2) fluxes. Throughout the night, the measured particle flux at the top of the tower was close to zero, but early in the morning there was an upward particle flux peak that is not likely a result of entrainment or local pollution. It is possible that these morning upward particle fluxes are associated with emission of primary biogenic particles from the rain forest. Emitted particles may be stored within the canopy during stable conditions at nighttime, similarly to CO(2), and being released from the canopy when conditions become more turbulent in the morning.
Resumo:
The application of laser induced breakdown spectrometry (LIBS) aiming the direct analysis of plant materials is a great challenge that still needs efforts for its development and validation. In this way, a series of experimental approaches has been carried out in order to show that LIBS can be used as an alternative method to wet acid digestions based methods for analysis of agricultural and environmental samples. The large amount of information provided by LIBS spectra for these complex samples increases the difficulties for selecting the most appropriated wavelengths for each analyte. Some applications have suggested that improvements in both accuracy and precision can be achieved by the application of multivariate calibration in LIBS data when compared to the univariate regression developed with line emission intensities. In the present work, the performance of univariate and multivariate calibration, based on partial least squares regression (PLSR), was compared for analysis of pellets of plant materials made from an appropriate mixture of cryogenically ground samples with cellulose as the binding agent. The development of a specific PLSR model for each analyte and the selection of spectral regions containing only lines of the analyte of interest were the best conditions for the analysis. In this particular application, these models showed a similar performance. but PLSR seemed to be more robust due to a lower occurrence of outliers in comparison to the univariate method. Data suggests that efforts dealing with sample presentation and fitness of standards for LIBS analysis must be done in order to fulfill the boundary conditions for matrix independent development and validation. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
The present analysis takes into account the acceleration term in the differential equation of motion to obtain exact dynamic solutions concerning the groundwater flow towards a well in a confined aquifer. The results show that the error contained in the traditional quasi-static solution is very small in typical situations.
Resumo:
Objective This study compares midazolam with omeprazole as marker drugs for the evaluation of CYP3A activity in nine healthy self-reported white Brazilian volunteers. Methods Omeprazole was also used to evaluate the CYP2C19 phenotype. The volunteers received p.o. 20 mg omeprazole, and blood samples were collected 3.5 h after drug administration. After a washout period of 10 days, the volunteers received p.o. 15 mg midazolam maleate, and serial blood samples were collected up to 6 h after administration of the drug. CYP2C19 was genotyped for the allelic variants CYP2C19*1, CYP2C19*2, CYP2C19*3, and CYP2C19*17. Analysis of omeprazole, hydroxyomeprazole, omeprazole sulfone, and midazolam in plasma was carried out by LC-MS/MS. Results The volunteers genotyped as CYP2C19*1*17, CYP2C19*17*17, CYP2C19*1*1 (n=8), or CYP2C19*17*2 (n=1) presented a median hydroxylation index (omeprazole/hydroxyomeprazole) of 1.35, indicating that all of them were extensive metabolizers of CYP2C19. The volunteers (n=9) presented a 0.12 log of the omeprazole/sulfone ratio and a median oral clearance of midazolam of 17.89 ml min(-1) kg(-1), suggesting normal CYP3A activity. Conclusions Orthogonal regression analysis between midazolam clearance and log of the plasma concentrations of the omeprazole/omeprazole sulfone ratio (R=-0.7544, P < 0.05) suggests that both midazolam and omeprazole can be used as markers of CYP3A activity in the population investigated.
Resumo:
Objective To compare the quality of induction and recovery, degree of muscle relaxation, clinically apparent potency and cardiopulmonary effects of racemic ketamine or S(+)-ketamine when used for total intravenous anesthesia in horses. Study design Prospective randomized clinical trial Animals Sixteen healthy stallions (323 +/- 99 kg), with a mean age of 6.2 years, undergoing castration. Methods Horses were pre-medicated with romifidine IV, 15 minutes before induction of anesthesia. Each animal was then randomly allocated to receive either diazepam and ketamine (DK) or diazepam and S(+)-ketamine (DKS) at similar doses to induce anesthesia. For maintenance of anesthesia, 1/4 of the initial bolus of ketamine alone or S(+)-ketamine alone was administered, as required. Heart rate (HR), respiratory rate (RR) and systolic blood pressure were measured before and at 10-minute intervals during recumbency. Time from induction to lateral recumbency, time from induction to first additional dose, time from last additional dose to return to sternal posture and time from last additional dose to standing were recorded, and a subjective evaluation of quality of induction, endotracheal intubation, muscle relaxation and quality of recovery was recorded. Results The quality of the induction and duration of anesthesia were similar in both groups. HR, RR and systolic blood pressure were not significantly different between groups. Although some animals which received DKS showed some minor excitatory effects (25% of them) during the induction of anesthesia, these animals received 32% fewer doses for the maintenance of anesthesia and the recovery scores were better. Conclusions and clinical relevance S(+)-ketamine showed some advantages over racemic ketamine, such as less anesthetic agent being required and better overall recovery from anesthesia. Further studies are needed to obtain the optimum induction dose for the S(+)-ketamine.
Resumo:
Purpose: To evaluate the influence of surface treatments on microtensile bond strength of luting resin cements to fiber posts. Materials and Methods: Forty-two quartz fiber posts (Light Post, RTD) were divided into 7 groups (n = 6) according to the surface treatment. I and 11: experimental patented industrial treatment consisting of zirconium oxide coating and silanization (RTD); III: industrial treatment followed by adhesive application (XPBond, Dentsply Caulk); IV: adhesive (XPBond); V: adhesive (Prime&Bond NT, Dentsply Caulk); VI: silane (Calibra Silane, Dentsply Caulk); VII: no treatment. Adhesives were used in the self-curing mode. Two cements (Sealbond, RTD - group 1, and Calibra, Dentsply Caulk - groups 11 to VII) were applied on the posts to produce cylindrical specimens. Post/cement interfaces were evaluated under SEM. The surface of the industrially coated posts was examined using energy dispersive analysis by x-ray. Cylinders were cut to obtain microtensile sticks that were loaded in tension at a crosshead speed of 0.5 mm/min until failure. Statistical analysis was performed using Kruskal-Wallis analysis of variance followed by Dunn`s multiple range test for post-hoc comparisons (p < 0.05). Weibull analysis was also performed. Results: The post/cement bond strength was significantly higher on fiber posts treated industrially (I: 23.14 +/- 8.05 MPa; II: 21.56 +/- 7.07 MPa; III: 22.37 +/- 7.00 MPa) or treated with XPBond adhesive (IV: 21.03 +/- 5.34 MPa) when compared to Prime&Bond NT application (V: 14.05 +/- 5.06 MPa), silanization (VI: 6.31 +/- 4.60 MPa) or no treatment (VII: 4.62 +/- 4.31) of conventional fiber posts (p < 0.001). Conclusion: The experimental industrial surface treatment and the adhesive application enhanced fiber post to resin cement interfacial strength. Industrial pretreatment may simplify the clinical luting procedure.
Resumo:
Objective: To verify an association, if it exists, between obesity and blood pressure raised beyond the 90th percentile in children and adolescents, and to determine the measure of adiposity that best correlates with blood pressure in these subjects. Design: Cross-sectional study. Setting: A school-based study in Belo Horizonte, Brazil. Participants: We selected randomly 1,403 students, aged from 6 to 18 years, from 545,046 students attending 521 public and private schools. Those selected completed the study. Main measures of outcome: We recorded the weight, height, skin fold in the triceps, subscapular, and suprailiac areas, waist and hip circumference, body-mass index, and resting systolic and diastolic blood pressures using a mercury sphygmomanometer. Results: In univariate analyses, body mass index greater or lesser than 85th percentile, measurements of skin thickness in the subscapular and suprailiac areas, and the sum of all measurements of skinfold thickness, were associated with both systolic and diastolic measurements of blood pressure. After multivariate analyses that adjusted for all measurements of adiposity except itself, and age, race, and socioeconomic state, we found that the increased body mass index was associated with a 3.6-fold increased frequency of elevated systolic measurements of blood pressure, with 9596 confidence intervals from 2.2 to 5.8, and a 2.7-fold increased frequency of elevated measurements of diastolic blood pressure, with 95% confidence intervals from 1.9 to 4.0. Conclusions: Body-mass index serves as a better predictor of elevated blood pressure among children than do local measurements of adiposity.
Resumo:
The purpose of this article is to study the application of the holographic interferometry techniques in the structural analysis of submarine environment. These techniques are widely used today, with applications in many areas. Nevertheless, its application in submarine environments presents some challenges. The application of two techniques, electronic speckle pattern interferometry (ESPI) and digital holography, comparison of advantages and disadvantages of each of them is presented. A brief study is done on the influence of water properties and the optical effects due to suspended particles as well as possible solutions to minimize these problems. (C) 2009 Elsevier Ltd. All rights reserved.
Resumo:
Background The development of products and services for health care systems is one of the most important phenomena to have occurred in the field of health care over the last 50 years. It generates significant commercial, medical and social results. Although much has been done to understand how health technologies are adopted and regulated in developed countries, little attention has been paid to the situation in low- and middle-income countries (LMICs). Here we examine the institutional environment in which decisions are made regarding the adoption of expensive medical devices into the Brazilian health care system. Methods We used a case study strategy to address our research question. The empirical work relied on in-depth interviews (N = 16) with representatives of a wide range of actors and stakeholders that participate in the process of diffusion of CT (computerized tomography) scanners in Brazil, including manufacturers, health care organizations, medical specialty societies, health insurance companies, regulatory agencies and the Ministry of Health. Results The adoption of CT scanners is not determined by health policy makers or third-party payers of public and private sectors. Instead, decisions are primarily made by administrators of individual hospitals and clinics, strongly influenced by both physicians and sales representatives of the medical industry who act as change agents. Because this process is not properly regulated by public authorities, health care organizations are free to decide whether, when and how they will adopt a particular technology. Conclusions Our study identifies problems in how health care systems in LMICs adopt new, expensive medical technologies, and suggests that a set of innovative approaches and policy instruments are needed in order to balance the institutional and professional desire to practise a modern and expensive medicine in a context of health inequalities and basic health needs.
Resumo:
Because of the scarcity of information about the comparison of training to sedentarism beforehand immobilization and rehabilitation through muscle mechanical properties, the present work investigates this theme. Seventy rats were divided into 7 groups: 1-control (C); 2-trained (T); 3-sedentary (S); 4-trained and immobilized (TI); 5-sedentary and immobilized (SI); 6-trained, immobilized and rehabilitated (TIR); 7-sedentary, immobilized and rehabilitated (SIR). Interventions: Swimming training; Sedentarism (reduced size cages); Cast immobilization (pelvic limb) and water rehabilitation. Load at the limit of proportionality (LLP), maximum limit load (MLL) and stiffness (St) were the mechanical properties determined after a mechanical test of traction of the gastrocnemius. The training improved all mechanical properties when compared to sedentarism. After immobilization, LLP and MLL were reduced in TI and SI. However, there was no difference in St between C and TI. Additionally, TI showed improved MLL when compared to SI. The comparison of TI and TIR showed significant melioration in all properties after remobilization. SIR showed an improvement only in MLL when compared to SI. Significant melioration in LLP and St was observed in TIR compared to SIR. We demonstrated that the training before immobilization and rehabilitation had a positive effect on the muscle mechanical behavior compared to sedentarism. This analysis is of fundamental importance because it helps characterize the muscle tissue under different functional demands.
Resumo:
Considering the difficulties in finding good-quality images for the development and test of computer-aided diagnosis (CAD), this paper presents a public online mammographic images database free for all interested viewers and aimed to help develop and evaluate CAD schemes. The digitalization of the mammographic images is made with suitable contrast and spatial resolution for processing purposes. The broad recuperation system allows the user to search for different images, exams, or patient characteristics. Comparison with other databases currently available has shown that the presented database has a sufficient number of images, is of high quality, and is the only one to include a functional search system.
Resumo:
This article presents a proposal of a systemic model composed for the micro and small companies (MSE) of the region of Ribeiro Preto and the agents which influenced their environment. The proposed model was based on Stafford Beer`s (Diagnosing the system for organizations. Chichester, Wiley, 1985) systemic methodologies VSM (Viable System Model) and on Werner Ulrich`s (1983) CSH (Critical Systems Heuristics). The VSM is a model for the diagnosis of the structure of an organization and of its flows of information through the application of the cybernetics concepts (Narvarte, In El Modelo del Sistema Viable-MSV: experiencias de su aplicacin en Chile. Proyecto Cerebro Colectivo del IAS, Santiago, 2001). On the other hand, CSH focus on the context of the social group applied to the systemic vision as a counterpoint to the organizational management view considered by the VSM. MSE of Ribeiro Preto and Sertozinho had been analyzed as organizations inserted in systems that relate and integrate with other systems concerning the public administration, entities of representation and promotion agencies. The research questions: which are the bonds of interaction among the subsystems in this process and who are the agents involved? The systemic approach not only diagnosed a social group, formed by MSE of Ribeiro Preto and Sertozinho, public authorities and support entities, but could also delineate answers that aimed the clarification of obscure questions generating financial assistance to the formularization of efficient actions for the development of this system.