6 resultados para Kinnunen, Alina

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Far too often, phenotypic divergence has been misinterpreted as genetic divergence, and based on phenotypic divergence, genetic divergence has been indicated. We have attempted to disprove this statement and call for the differentiation of phenotypic and genotypic variation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: This study was designed to identify the mucosa-associated microflora in patients with severe ulcerative colitis before and after restorative proctocolectomy with ileoanal pouch construction in comparison with historic controls. METHODS: Ten patients with a diagnosis of ulcerative colitis were evaluated. Mucus was collected during colonoscopy from all segments of the colon and terminal ileum before surgery, and from the ileal pouch two and eight months after ileostomy closure. The prevalence and mean concentration of the mucosa-associated microflora were compared over time and with historic controls. RESULTS: Veillonella sp was the most prevalent bacterium in patients and controls. Klebsiella sp was significantly more prevalent in the ileum of controls, was not found in patients with ulcerative colitis, and after proctocolectomy returned to values found in controls. Some bacteria such as Enterobacter sp, Staphylococcus sp (coag-), Bacteroides sp (npg), Lactobacillus sp, and Veillonella sp had higher mean concentrations in the ileal pouch of patients after surgery than in controls. CONCLUSION: No bacterium was identified that could be exclusively responsible for the maintenance of the inflammatory process. The mucosa-associated microflora of patients with ulcerative colitis underwent significant changes after proctocolectomy with ileal pouch construction and returned to almost normal values for some bacteria.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

objective. To describe the management of patients with long-term central venous catheters (CVCs) during an outbreak of infection due to Pseudomonas putida and Stenotrophomonas maltophilia associated with contaminated heparin catheter-lock solution. design. Descriptive study. setting. Private, 250-bed tertiary-care hospital. methods. In March 2003, we identified 2 febrile cancer patients with P. putida bacteremia. Over 2 days, 7 cases of bacteremia were identified; lots of syringes prefilled with heparin catheter-lock solution, supplied by a compounding pharmacy, were recalled and samples were cultured. More cases of bacteremia appeared during the following days, and any patient who had had a catheter lock infused with the suspect solution was asked to provide blood samples for culture, even if the patient was asymptomatic. Isolates that were recovered from culture were typed by pulsed-field gel electrophoresis. Antimicrobial salvage treatment of long-term CVCs was attempted. results. A total of 154 patients had had their catheter lock infused with solution from the lots that were suspected of being contaminated. Only 48 of these patients had CVCs. By day 7 of the outbreak, 18 of these patients had become symptomatic. Twenty-six of the remaining 30 asymptomatic patients then also provided blood samples for culture, 10 of whom developed fever shortly after samples were collected. Thirty-two patients were identified who had P. putida bacteremia; 9 also had infection due to S. maltophilia. Samples from 1 of the 3 lots of prefilled syringes in use at the time of the outbreak also grew P. putida on culture. Molecular typing identified 3 different clones of P. putida from patients and heparin catheter-lock solution, and 1 clone of S. maltophilia. A total of 27 patients received antimicrobial therapy regimens, some of which included decontamination of the catheter lock with anti- infective lock solution. Of 27 patients, 19 (70%) retained their long-term CVC during the 6-month follow-up period. conclusions. To our knowledge, this is one of the largest prospective experiences in the management of bloodstream infection associated with long-term CVCs. The infections were caused by gram-negative bacilli and were managed without catheter removal, with a high response rate. We emphasize the risks of using intravenous formulations of medications supplied by compounding pharmacies that produce large quantities of drugs.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Nitric oxide (NO) exerts important physiological and pathological roles in humans. The study of NO requires the immunolocalization of its synthesizing enzymes, neuronal, endothelial and inducible NO synthases (NOS). NOS are labile to formalin-fixation and paraffin-embedding, which are used to prepare human archival tissues. This lability has made NOS immunohistochemical studies difficult, and a detailed protocol is not yet available. We describe here a protocol for the immunolocalization of NOS isoforms in human archival cerebellum and non-nervous tissues, and in rat tissues and cultured cells. Neuronal NOS antigenicity in human archival and rat nervous tissue sections was microwave-retrieved in 50 mM Tris-HCl buffer, pH 9.5, for 20 min at 900W. Neuronal NOS was expressed in stellate, basket, Purkinje and granule cells in human and rat cerebellum. Archival and frozen human cerebellar sections showed the same neuronal NOS staining pattern. Archival cerebellar sections not subjected to antigen retrieval stained weakly. Antigenicity of inducible NOS in human lung was best retrieved in 10 mM sodium citrate buffer, pH 6.0, for 15 min at 900W. Inflammatory cells in a human lung tuberculoma were strongly stained by anti-inducible NOS antibody. Anti-endothelial NOS strongly stained kidney glomeruli. Cultured PC12 cells were strongly stained by anti-neuronal NOS without antigen retrieving. The present immunohistochemistry protocol is easy to perform, timeless, and suitable for the localization of NOS isoforms in nervous and non-nervous tissues, in human archival and rat tissues. It has been extensively used in our laboratory, and is also appropriate for other antigens. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Speech understanding disorders in the elderly may be due to peripheral or central auditory dysfunctions. Asymmetry of results in dichotic testing increases with age, and may reflect on a lack of inter-hemisphere transmission and cognitive decline. Aim: To investigate auditory processing of aged people with no hearing complaints. Study design: clinical prospective. Materials and Methods: Twenty-two voluntary individuals, aged between 55 and 75 years, were evaluated. They reported no hearing complaints and had maximal auditory thresholds of 40 dB HL until 4 KHz, 80% of minimal speech recognition scores and peripheral symmetry between the ears. We used two kinds of tests: speech in noise and dichotic alternated dissyllables (SSW). Results were compared between males and females, right and left ears and between age groups. Results: There were no significant differences between genders, in both tests. Their Left ears showed worse results, in the competitive condition of SSW. Individuals aged 65 or older had poorer performances than those aged 55 to 64. Conclusion: Central auditory tests showed worse performance with aging. The employment of a dichotic test in the auditory evaluation setting in the elderly may help in the early identification of degenerative processes, which are common among these patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to verify and describe the presence of microorganisms in the single-use trocar after its use in surgical procedures, and after this device was submitted to cleaning, conditioning, and sterilization by physicochemical processes (formaldehyde, ethylene oxide, and hydrogen peroxide plasma). Twenty-eight trocars of the Ethicon, Auto-suture, and Aesculap brands, were randomly selected and analyzed after laparoscopic cholecystectomy. The results have shown that cultures grown of the material collected from the trocars, immediately after its use and before its sterilization process, showed the presence of bacteria and fungi in 46.5% (13). In 53.5% (15) of the trocars, the presence of microorganisms was not detected, very likely due to niche`s scarcity. In the cultures grown of the 28 trocars after being submitted to sterilization processes, the presence of microorganisms was not verified. We can therefore conclude that although trocars possess compartments not easily accessed for cleaning, these devices can be adequately cleaned and effectively sterilized, when well manipulated, in the institution where the study was carried out by the processes of steam sterilization at low temperature and formaldehyde, ethylene oxide, and hydrogen peroxide plasma.