7 resultados para Kernspintomographie, Medizin, lunge

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of the present study was to provide a numerical measure, through the process capability indexes (PCIs), C(p) and C(pk), on whether or not the manufacturing process can be considered capable of producing metamizol (500 mg) tablets. They were also used as statistical tool in order to prove the consistency of the tabletting process, making sure that the tablet weight and the content uniformity of metamizol are able to comply with the preset requirements. Besides that, the ANOVA, the t-test and the test for equal variances were applied to this study, allowing additional knowledge of the tabletting phase. Therefore, the proposed statistical approach intended to assure more safety, precision and accuracy on the process validation analysis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A simplex-lattice statistical project was employed to study an optimization method for a preservative system in an ophthalmic suspension of dexametasone and polymyxin B. The assay matrix generated 17 formulas which were differentiated by the preservatives and EDTA (disodium ethylene diamine-tetraacetate), being the independent variable: X-1 = chlorhexidine digluconate (0.010 % w/v); X-2 = phenylethanol (0.500 % w/v); X-3 = EDTA (0.100 % w/v). The dependent variable was the Dvalue obtained from the microbial challenge of the formulas and calculated when the microbial killing process was modeled by an exponential function. The analysis of the dependent variable, performed using the software Design Expert/W, originated cubic equations with terms derived from stepwise adjustment method for the challenging microorganisms: Pseudomonas aeruginosa, Burkholderia cepacia, Staphylococcus aureus, Candida albicans and Aspergillus niger. Besides the mathematical expressions, the response surfaces and the contour graphics were obtained for each assay. The contour graphs obtained were overlaid in order to permit the identification of a region containing the most adequate formulas (graphic strategy), having as representatives: X-1 = 0.10 ( 0.001 % w/v); X-2 = 0.80 (0.400 % w/v); X-3 = 0.10 (0.010 % w/v). Additionally, in order to minimize responses (Dvalue), a numerical strategy corresponding to the use of the desirability function was used, which resulted in the following independent variables combinations: X-1 = 0.25 (0.0025 % w/v); X-2 = 0.75 (0.375 % w/v); X-3 = 0. These formulas, derived from the two strategies (graphic and numerical), were submitted to microbial challenge, and the experimental Dvalue obtained was compared to the theoretical Dvalue calculated from the cubic equation. Both Dvalues were similar to all the assays except that related to Staphylococcus aureus. This microorganism, as well as Pseudomonas aeruginosa, presented intense susceptibility to the formulas independently from the preservative and EDTA concentrations. Both formulas derived from graphic and numerical strategies attained the recommended criteria adopted by the official method. It was concluded that the model proposed allowed the optimization of the formulas in their preservation aspect.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The bioequivalence of two different tablet formulations of tirtidazole (CAS 19387-91-8) was determined in healthy volunteers after a single dose in a randomized crossover study, with a 1-week washout period between the doses. Reference and test products were administered to 24 volunteers with 240 mL water after overnight fasting. Plasma concentrations of tinidazole were monitored by a high-performance liquid chromatographic method (HPLC) over a period of 72 h after the administration. The pharmacokinetic parameters AUC(0-t), AUC(0-infinity), C(max), T(max), T((1/2)el) and beta were determined from plasma concentration time profile of both formulations and found to be in good agreement with previously reported values. The calculated pharmacokinetic parameters were compared statistically to evaluate bioequivalence between the two brands. The analysis of variance (ANOVA) did not show any significant difference between the two formulations and 90% confidence intervals for the ratio of C(max) (93.9 - 102.6%), AUC(0-t), (94.9-101.1%) and AUC(0-infinity) (94.6-100.8%) values for the test and reference products were within the 80 - 125% interval, satisfying bioequivalence criteria of the European Committee for Proprietary Medicinal Products and the US Food and Drug Administration Guidelines. These results indicate that the test and the reference products of tinidazole are bioequivalent and, thus, may be prescribed interchangeably.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Two different cefadroxil (CAS 50370-12-2) formulations were evaluated for their relative bioavailability in 24 healthy volunteers who received a single 500 mg oral dose of each preparation. An open, randomized clinical trial designed as a two-period crossover study with a 7-day washout period between doses was employed. Plasma samples for assessments of their cefadroxil concentration by HPLC-UV were obtained over 8 h after administration. Values of 48.94 +/- 10.18 mu g . h/ml for test, and 48.51 +/- 9.02 mu g . h/ml for the reference preparation AUC(0-t) demonstrate a nearly identical extend of drug absorption. Maximum plasma concentration C-max of 16.04 +/- 4.94 mu g/ml and 16.01 +/- 4.02 mu g/ml achieved for the test and reference preparations did not differ significantly. The parametric 90% confidence intervals (CI) of the mean of the difference (test-reference) between log-transformed values of the two formulations were 96.80% to 104.51% and 92.01% to 107.00% for AUC(0-t) and C-max, respectively. Since for both AUC(0-t) or C-max the 90% CI values are within the interval proposed by the Food and Drug Administration, the test product is bioequivalent to the reference product for both the rate and extent of absorption after single dose administration.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

There are many techniques for the treatment of hip dysplasia, and novel research is currently being undertaken in the hope of obtaining more efficient and less traumatic techniques. The denervation of the hip joint capsule is a simple and effective technique that allows recovery of the functional activity of the affected limbs in significantly less time than other techniques. This surgical procedure consists of removing the acetabular periosteum, thus eliminating the nerve fibres with consequent analgesia. The aim of this investigation was to quantify the number of nerve fibres present in different regions of the acetabular periosteum. The knowledge of regional differences is potentially valuable for the refining of the denervation technique of the hip joint capsule. Thirty canine acetabular fragments were used to compare the nerve fibre density of the periosteum. The results showed a significant difference between the mean density of nerve fibres at the cranial and dorsal-lateral portion (approximately 75 fibres/mm(2)) and caudal lateral portion (approximately 60 fibres/mm(2)) of the acetabulum. Those fibres at the pedosteum are almost positioned in a sagittal plane, pointing towards the joint capsule, suggesting the some density in the latter region. These results indicate a new approach to the articular denervation technique, thus obtanining even better results for the treatment of hip dysplasia in dogs.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An extensible internal device (EID) was developed to preserve growth plate during the treatment of fracture complications or segmental bone loss from tumour resection in children. Since this type of extensible, trans-physeal, internal fixation device has only been used in a few paediatric cases; the aim of this study was to evaluate an in vivo canine study, a surgical application of this device, and its interference with longitudinal growth of the non-fractured distal femur. Ton clinically healthy two- to three-month-old poodles weighing 1.5-2.3 kg were used. Following a medial approach to the right distal femur, one extremity of the EID, similar to a T-plate, was fixed in the femoral condyle with two cortical screws placed below the growth plate. The other extremity, consisting of an adaptable brim with two screw holes and a plate guide, was fixed in the third distal of the femoral diaphysis with two cortical screws. The EID was removed 180 days after application. All of the dogs demonstrated full weight-bearing after surgery. The values of thigh and stifle circumferences, and stifle joint motion range did not show any difference between operated and control hindlimbs. The plate slid in the device according to longitudinal bone growth, in all but one dog. In this dog, a 10.5% shortening of the femoral shaft was observed due to a lack of EID sliding. The other dogs had the some longitudinal lengths in both femurs. The EID permits longitudinal bone growth without blocking the distal femur growth plate if appropriately placed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To assess the comparative bioavailability of two formulations (250 mg/5 mL suspension) of cefuroxime axetil (CAS 64544-07-6), administered with food, in healthy volunteers of both sexes. Methods: The study was conducted using an open, randomized, two-period crossover design with a 1-week washout interval. Plasma samples were obtained for up to 12 h post dose. Plasma cefuroxime axetil concentrations were analyzed by liquid chromatography coupled with tandem mass spectrometry (LC-MS-MS) with negative ion electrospray ionization using multiple reactions monitoring (MRM). From the cefuroxime axetil plasma concentration vs. time curves, the following pharmacokinetic parameters were obtained: AUC(last) and C(max). Results: The limit of quantification was 0.1 mu g/mL for plasma cefuroxime axetil analysis. The geometric mean and 90% confidence interval CI of test/reference product percent ratios were: 106.1% (100.8%-111.8%) for C(max), 109.4% (104.8%-114.2%) for AUC(last). Conclusion: Since the 90% Cl for AUC(last) and C(max) ratios were within the 80-125 % interval proposed by the US FDA, it was concluded that cefuroxime axetil (test formulation, 250 mg/5 mL suspension) was bioequivalent to a reference formulation under fed conditions, for both the rate and extent of absorption.