2 resultados para Indirect antibody competition ELISA
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)
Resumo:
Background: Human erythrovirus B 19, endemic in the Amazon region since 1990, is associated with a wide spectrum of clinical presentations. Objectives: To assess the prevalence of erythrovirus B 19 infection and the relative frequency of erythrovirus B 19 genotypes in patients in the Amazon region with various clinical presentations. Study design: A total of 487 clinical samples obtained from patients with symptoms suggestive of erythrovirus infection were tested using specific IgM and IgG antibody assays (ELISA) and PCR for viral DNA detection. Partial VP1 and VP2 regions were sequenced and genotyped by phylogenetic reconstruction. Results: B 19 DNA was detected in 117 (24%) of 487 samples. Of these, 106 (91%) isolates were genotype I and II (9%) were genotype 3. No genotype 2 was found. Genotype I had three clusters (A1, A2 and 13) and all genotype 3 sequences were subtype 3b. All patients with hernatological disorders within cluster B of genotype I were infected by the sarne B 19 lineage, suggesting that this lineage of B 19 may have been transmitted via transfusion of blood products. Conclusion: We reported two genotypes, I and 3b, with three genotype I clusters co-circulating in the Amazon region during the past 10 years. (C) 2008 Elsevier B.V. All rights reserved.
Resumo:
Background: Oxidative modification of low-density lipoprotein (LDL) plays a key role in the pathogenesis of atherosclerosis. LDL(-) is present in blood plasma of healthy subjects and at higher concentrations in diseases with high cardiovascular risk, such as familial hypercholesterolemia or diabetes. Methods: We developed and validated a sandwich ELISA for LDL(-) in human plasma using two monoclonal antibodies against LDL(-) that do not bind to native LDL, extensively copper-oxidized LDL or malondialdehyde-modified LDL. The characteristics of assay performance, such as limits of detection and quantification, accuracy, inter- and intra-assay precision were evaluated. The linearity, interferences and stability tests were also performed. Results: The calibration range of the assay is 0.625-20.0 mU/L at 1: 2000 sample dilution. ELISA validation showed intra- and inter- assay precision and recovery within the required limits for immunoassays. The limits of detection and quantification were 0.423 mU/L and 0.517 mU/L LDL(-), respectively. The intra- and inter- assay coefficient of variation ranged from 9.5% to 11.5% and from 11.3% to 18.9%, respectively. Recovery of LDL(-) ranged from 92.8% to 105.1%. Conclusions: This ELISA represents a very practical tool for measuring LDL(-) in human blood for widespread research and clinical sample use. Clin Chem Lab Med 2008; 46: 1769-75.