27 resultados para Hearing Losses
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)
Resumo:
We assessed the feasibility of obtaining probe microphone measurements of hearing aids at a distance. Face-to-face and remote probe microphone measurements were carried out in 60 hearing aid users (mean age 67 yrs) with uni- or bilateral hearing losses (105 ears tested). The participant and a facilitator were located in a room equipped with a probe microphone system interfaced to a PC. Desktop videoconferencing and application sharing was used to allow an audiologist in another room to instruct the facilitator and control the equipment via the LAN. There were significant correlations between face-to-face and remote real ear unaided response (REUR), aided response (REAR) and insertion gain (REIG) at seven discrete frequencies from 250 to 6000 Hz. Differences between face-to-face and remote responses were within the reported variability for probe microphone measurements themselves. The results show that remote probe microphone measurements are feasible and might improve the quality of public hearing aid services and professional training in Brazil.
Resumo:
In this paper, we estimate the losses during teleportation processes requiring either two high-Q cavities or a single bimodal cavity. The estimates were carried out using the phenomenological operator approach introduced by de Almeida et al. [Phys. Rev. A 62, 033815 (2000)].
Resumo:
This paper presents an approach for the active transmission losses allocation between the agents of the system. The approach uses the primal and dual variable information of the Optimal Power Flow in the losses allocation strategy. The allocation coefficients are determined via Lagrange multipliers. The paper emphasizes the necessity to consider the operational constraints and parameters of the systems in the problem solution. An example, for a 3-bus system is presented in details, as well as a comparative test with the main allocation methods. Case studies on the IEEE 14-bus systems are carried out to verify the influence of the constraints and parameters of the system in the losses allocation.
Resumo:
An ultra-low carbon steel (30 ppm after decarburization) containing Al and Si was aged for distinct soaking times at 210 degrees C. The core loss increased continuously until around 24 h. After that, only slight changes were verified. It was found that only the hysteresis loss component changed during the aging treatment. By internal friction test and transmission electron microscopy it was seen that carbon precipitation caused the magnetic aging. By scanning electron microscopy it could be concluded that the increase of aging index was attributed to the high number of carbides larger than 0.1 mu m. (C) 2008 Elsevier B. V. All rights reserved.
Resumo:
Square and two-level pulse width modulation (PWM) magnetic induction waveforms are investigated and their effect on electrical steels losses as a function of the grain size is determined. The increase of hysteresis losses-as compared to that resulting from sinusoidal voltages-occurs only for two-level PWM waveforms. Total losses are lower for square waveform, and the difference between losses under square and sinusoidal waveform increase with increasing grain size, result explained with the loss separation model. (C) 2008 Elsevier B.V. All rights reserved.
Resumo:
Florida Spodosols axe sandy, inherently low in Fe- and Al-based minerals, and sorb phosphorus (P) poorly. We evaluated runoff and leachate P losses from a typical Florida Spodosol amended with biosolids and triple superphosphate (TSP). Phosphorus losses were evaluated with traditional indoor rainfall simulations but used a double-deck box arrangement that allowed leaching and runoff to be determined simultaneously. Biosolids (Lakeland, OCUD, Milorganite, and Disney) represented contrasting values of total P, percent water-extractable p (PWEP), and percentage of solids. All P sources were surface applied at 224 kg P ha(-1), representing a soil P rate typical of N-based biosolids application. All biosolids-P sources lost less P than TSp, and leachate-P losses generally dominated. For Lakeland-amended I soil, bioavailable P (BAP) was mainly lost by runoff (81% of total BAP losses). This behavior was due to surface scaling and 1 drying after application of the slurry (31 g kg(-1) solids), material. For all other P sources, BAP losses in leachate were much,greater than in runoff, representing 94% of total BAP losses for TSP, 80% for Milorganite, 72% for Disney, and 69% for OCUD treatments. Phosphorus leaching can be extreme and represents a great concern in many coarse-textured Florida Spodosols, and other coastal plain soils with low P-sorption,capacities. The PWEP values of P sources were significantly correlared with total P and BAP losses in runoff and leachate. The PWEP of a source can serve as a good indicator of potential P loss when amended to sandy soils with low P-retention capacities.
Resumo:
The wastes occurred during the harvest cause a hard impact in the agricultural business. About the soy fields, recent researches indicate that half of this waste could be avoided, reducing the cost of production and resultant earning of the companies. The purpose of this article is to analyze the estimative of soy harvest field area of 2006/07 to 2007/08 and respective production, subsidy estimate the waste that could be avoided during the harvest, considerating tolerable levels of 60 Kg by hectare, accordant is the model adopted on USA e Brazil. This research was based in a bibliographic study to explain and analyze all sides, practical and theoretical around the investigate problem. It was checked that is possible expect and avoid these wastes during the harvest. Such wastes overcome the mark of 20,000 ton/year, that in money talks represent over R$ 1.000.000 mil/year. Conclude however that wastes when treated provide a production cost reduction, indicating execution and a positive impact on agricultural companies` earnings.
Resumo:
This article analyzes traditions of debate about the teaching of history in Brazil since the 1964-1984 dictatorship. It discusses the changes, continuities, achievements and losses in the history of the discipline. It emphasizes the importance of school culture, the necessary continuity of the school as an institution and dialogue with non-school forms of education.
Resumo:
Background and purpose: Tinnitus is a frequent disorder which is very difficult to treat and there is compelling evidence that tinnitus is associated with functional alterations in the central nervous system. Targeted modulation of tinnitus-related cortical activity has been proposed as a promising new treatment approach. We aimed to investigate both immediate and long-term effects of low frequency (1 Hz) repetitive transcranial magnetic stimulation (rTMS) in patients with tinnitus and normal hearing. Methods: Using a parallel design, 20 patients were randomized to receive either active or placebo stimulation over the left temporoparietal cortex for five consecutive days. Treatment results were assessed by using the Tinnitus Handicap Inventory. Ethyl cysteinate dimmer-single photon emission computed tomography (SPECT) imaging was performed before and 14 days after rTMS. Results: After active rTMS there was significant improvement of the tinnitus score as compared to sham rTMS for up to 6 months after stimulation. SPECT measurements demonstrated a reduction of metabolic activity in the inferior left temporal lobe after active rTMS. Conclusion: These results support the potential of rTMS as a new therapeutic tool for the treatment of chronic tinnitus, by demonstrating a significant reduction of tinnitus complaints over a period of at least 6 months and significant reduction of neural activity in the inferior temporal cortex, despite the stimulation applied on the superior temporal cortex.
Resumo:
The aim of this study was to establish parameters for the gaps-in-noise test in normal-hearing young adults. One hundred subjects (50 males and 50 females) received an audiological evaluation to rule out hearing loss and auditory processing disorder. The gaps-in-noise test was then conducted on all subjects. The mean gap detection threshold was 4.19 ms. A psychometric function by gap duration was constructed, revealing that the percentage of correct responses was less than or equal to 5% for a gap duration of 2 ms, 10-30% for a gap duration of 3 ms, 60-70% for a gap duration of 4 ms, and over 96% for gap durations of 5 ms or longer. The results suggest that the data obtained can be applied as reference values for future testing. In the subjects evaluated, the gaps-in-noise test proved to be consistent with low variability.
Resumo:
This study was designed to investigate the feasibility of applying tone-ABRs in the nursery and neonatal intensive care unit (NICU), and to provide normative tone-ABR data from neonates. Normative tone-ABR latency data were determined. The study obtained intensity series of tone-ABRs from thirty preterm neonates and twenty fullterm neonates who had confirmed normal peripheral auditory function after passing both an OAE and ABR screening examination. ABRs were collected in response to 500, 1500, and 4000 Hz tone bursts at 70, 50, 30, and 20 dB nHL. Mean wave V latencies were compared between groups, ears, and by gender. Responses to tone bursts of 20 and 30 dB nHL were detected in 97% and 100% of all ears respectively, in addition to responses to the higher-intensity stimuli. Preterm neonates` ABRs showed significantly longer latencies than those of the full-term infants. Tone-ABR evaluation was found to be both feasible and reliable as a measure of auditory function in neonates.
Resumo:
In Brazil there are no specific tests for either signed or spoken language for deaf children. A protocol evaluating communicative abilities independent of modality of communication (sign language or spoken language), and comprising assessments of (a) pragmatic profile; (b) modality of communication and linguistic level; (c) complexity of communication; and (d) style and efficacy of communication between parent and child was administered to 127 deaf and hearing children. The children, aged 3-6 years old, were distributed in three groups: 20 with severe hearing loss, 40 with profound hearing loss and 67 normally hearing. Deaf children were found to be delayed, independent of their linguistic level and preferred modality of communication. The protocol in this study proved to be an useful instrument for gathering relevant information about the three groups of preschool children`s communicative abilities, and particularly suitable for use in countries where standardized assessments are not available. Learning outcomes: The reader will be introduced to the use of an assessment protocol comprising its development, application and data analysis. The reader will be informed about assessment of deaf children`s preferred modality of communication, by the participation of a bilingual (sign language user) professional. Communication abilities can be assessed independently of the linguistic modality. In developing countries in general, where simple and easy to administer assessments tools are scarce, such a protocol is of specific value. (c) 2010 Elsevier Inc. All rights reserved.
Resumo:
The treatment of sensorineural hearing loss is based on hearing aids, also known as individual sound amplification devices. The hearing aids purchased by the Brazilian Government, aiming at fulfilling public policies, are based on dedicated components, which bring about benefits, but also render them expensive and may impair repair services after manufacture`s warranty expires. Aim: to design digital behind-the-ear hearing aids built from standardized components coming from the very supply chain of these manufacturers. Study design: experimental. Materials and Methods: to identify the supply chain of these manufacturers, request samples and set up hearing aids in the laboratory. Results: The developed hearing aids did not show lesser electroacoustic characteristics when compared to those acquired by the Government, also being tested by the same reference international technical standard. Conclusion: It is possible to develop digital behind-the-ear hearing aids based on off-the-shelf components from hearing aid manufacturers` supply chain. Their advantages include low operational costs - for acquisition (with clear advantages for the Government) and service (advantage for the patient).
Resumo:
Tinnitus is a symptom present in approximately 15% of the world population. Most patients are between 40 and 80 years of age; the prevalence above 60 reaches 33%. About 20% have moderate to severe impact in the quality of life but the factors associated with the tinnitus annoyance are not completely known. Aim: The objective of this study is to evaluate the relationship between age, gender and hearing loss on tinnitus annoyance. Materials and methods: 68 patients were evaluated at the tinnitus center at our hospital, from March 2007 to march 2008, with a detailed interview, complete otolaryngological examination, the Portuguese version of the Tinnitus Handicap Inventory and pure tone audiometry. Results: Age varied from 24 to 83 (mean=59); the mean THI value was 39 (females: 36; males: 44). THI grades were: slight: 32.3%; mild: 19.1%; moderate: 20.6%; severe: 13.2% and catastrophic: 14.7%. No significant correlation was found between gender (p=0.30), age (p=0.77) hearing loss (p>0.05 for all averages analyzed) and tinnitus severity. Conclusion: Gender, age and hearing loss do not influence tinnitus annoyance, using the THI.
Resumo:
Profound hearing loss is a disability that affects personality and when it involves teenagers before language acquisition, these bio-psychosocial conflicts can be exacerbated, requiring careful evaluation and choice of them for cochlear implant. Aim: To evaluate speech perception by adolescents with profound hearing loss, users of cochlear Implants. Study Design: Prospective. Materials and Methods: Twenty-five individuals with severe or profound pre-lingual hearing loss who underwent cochlear implantation during adolescence, between 10 to 17 years and 11 months, who went through speech perception tests before the implant and 2 years after device activation. For comparison and analysis we used the results from tests of four choice, recognition of vowels and recognition of sentences in a closed setting and the open environment. Results: The average percentage of correct answers in the four choice test before the implant was 46.9% and after 24 months of device use, this value went up to 86.1% in the vowels recognition test, the average difference was 45.13% to 83.13% and the sentences recognition test together in closed and open settings was 19.3% to 60.6% and 1.08% to 20.47% respectively. Conclusion: All patients, although with mixed results, achieved statistical improvement in all speech tests that were employed.