15 resultados para HTS Coils
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)
Resumo:
A bifilar Bi-2212 bulk coil with parallel shunt resistor was tested under fault current condition using a 3 MVA single-phase transformer in a 220 V-60 Hz line achieving fault current peak of 8 kA. The fault current tests are performed from steady state peak current of 200 A by applying controlled short circuits up to 8 kA varying the time period from one to six cycles. The test results show the function of the shunt resistor providing homogeneous quench behavior of the HTS coil besides its intrinsic stabilizing role. The limiting current ratio achieves a factor 4.2 during 5 cycles without any degradation.
Resumo:
Several high temperature superconductor (HTS) tapes have been developed since the late eighties. Due to the new techniques applied for their production, HTS tapes are becoming feasible and practical for many applications. In this work, we present the test results of five commercial HTS tapes from the BSCCO and YBCO families (short samples of 200 mm). We have measured and analyzed their intrinsic and extrinsic properties and compared their behaviors for fault current limiter (FCL) applications. Electrical measurements were performed to determine the critical current and the n value through the V-I relationship under DC and AC magnetic fields. The resistance per unit length was determined as a function of temperature. The magnetic characteristics were analyzed through susceptibility curves as a function of temperature. As transport current generates a magnetic field surrounding the HTS material, the magnetic measurements indicate the magnetic field supported by the tapes under a peak current 1.5 times higher than the critical current, I(c). By pulsed current tests the recovery time and the energy/volume during a current fault were also analyzed. These results are in agreement with the data found in the literature giving the most appropriate performance conductor for a FCL device (I(peak) = 4 kA) to be used in a 220 V-60 Hz grid.
Resumo:
The evaluation of the electrical characteristics of technical HTS tapes are of the key importance in determining the design and operational features of superconducting power apparatuses as well as to understand the external factors which affect the superconducting performance. In this work we report the systematic measurements of the electric field versus current density, E-J relation of short samples for three commercial HTS tapes (BSCCO-2223 tapes, with and without steel reinforcement, and YBCO-coated conductor) at 77 K. In order to get sensitive and noiseless voltage signals the measurements were carried out with DC transport current and subjecting the broad surface tape to DC (0-300 mT) and AC (0-62 mT, 60 Hz) magnetic fields. The voltage is measured by a sensitive nanovoltmeter and the applied magnetic field is monitored by a Hall sensor placed on the tape broad surface. The comparison between the results obtained from the three tapes was done by fitting a power-law equation for currents in the vicinity of the critical current. For the current regime below the critical one a linear correlation of the electric field against the current density is observed. The BSCCO samples presented the same behavior, i.e., a decreasing of n-index with the increasing DC and AC magnetic field strength. Under AC field the decreasing slope of n-index is steeper as compared to DC field. The n-index curve for the YBCO tape showed similar behavior for AC field, however under DC field in the 0-390 mT range exhibited a slight decreasing of the n-index.
Resumo:
Neste trabalho é apresentado um experimento incluído no contexto de experimentos longos adotado nas disciplinas experimentais de eletricidade, magnetismo e óptica, e consiste na caracterização de um seletor de velocidades que funciona com campos elétricos e magnéticos cruzados. Utiliza-se um tubo de raios catódicos para gerar um feixe de elétrons. As placas de deflexão vertical do tubo geram o campo elétrico e um par de bobinas, com os eixos perpendiculares ao eixo do tubo, gera o campo magnético. São realizados estudos de trajetória dos elétrons com auxílio de um programa de simulação de elétrons.
Resumo:
The joint process between tapes of coated conductors is a critical issue for the most of the applications of high temperature superconductors (HTS). Using different fabrication techniques joints of YBCO coated superconductors were prepared and characterized through electrical measurements. For soldering material low melting point eutectic alloys, such as In-Sn (m.p. 116 degrees C) and Sn-Pb (m. p. 189 degrees C) were selected to prepare lap joints with effective length between 1 to 20 cm. The splice resistance and the critical current of the joints were evaluated by I-V curve measurements with the maximum current strength above the critical current, in order to evaluate the degree of degradation for each joint method. Pressed lap joints prepared with tapes without external reinforcement presented low resistance lap joint nevertheless some critical current degradation occurs when strong pressing is applied. When mechanical pressure is applied during the soldering process we can reduce the thickness of the solder alloy and a residual resistance arises from contributions of high resistivity matrix and external reinforcement. The lap joints for reinforced tape were prepared using two methods: the first, using ""as-supplied"" tape and the other after reinforcement-removal; in the latter case, the tapes were resoldered using Sn-Pb alloy. The results using several joint geometries, distinct surface preparation processes and different soldering materials are presented and analysed. The solder alloy with lower melting point and the longer joint length presented the smallest joint resistance.
Resumo:
Thyristor-based onload tap-changing ac voltage stabilizers are cheap and robust. They have replaced most mechanical tap-changers in low voltage applications from 300 VA to 300 M. Nevertheless, this replacement hardily applies to tap-changers associated to transformers feeding medium-voltage lines (typically 69 kV primary, 34.5 kV line, 10 MVA) which need periodical maintenance of contacts and oil. The Electric Power Research Institute (EPRI) has studied the feasibility of this replacement. It detected economical problems derived from the need for series association of thyristors to manage the high voltages involved, and from the current overload developed under line fault. The paper reviews the configurations used in that field and proposes new solutions, using a compensating transformer in the main circuit and multi-winding coils in the commutating circuit, with reduced overload effect and no series association of thyristors, drastically decreasing their number and rating. The stabilizer can be installed at any point of the line and the electronic circuit can be fixed to ground. Subsequent works study and synthesize several commutating circuits in detail.
Resumo:
Objectives: Acute pancreatitis (AP) protease release induces lung parenchymal destruction via matrix metalloproteinases (MMPs), a neutrophil (polymorphonuclear leukocyte)-dependent process. Recent studies in hemorrhagic shock revealed that hypertonic saline (HTS) has an anti-inflammatory effect and can inhibit a variety of neutrophil functions. The aim of this study was to determine whether HTS and its actions in the pathway of neutrophil migration, MMPs, and heat shock proteins (HSPs) are effective in protecting the lung from injury associated with AP. Methods: We determined neutrophil infiltration and expressions of MMPs and HSPs in the lung tissue after AP induced by retrograde infusion of 2.5% of sodium taurocholate. Results: Animals submitted to AP that received HTS compared with those who received normal saline presented with increased HSP70 and HSP90 expressions and reduced myeloperoxidase levels and MMP-9 expression and activity. Conclusions: Our data raised the hypothesis that a sequence of HTS lung protection events increases HSP70 and HSP90, inhibiting infiltration of neutrophils and their protease actions in the lung.
Resumo:
Background. Diving liver ischemia, the decrease in mitochondrial energy causes cellular damage that is aggravated after reperfusion. This injury can trigger a systemic inflammatory syndrome, also producing remote organ damage. Several substances have been employed to decrease this inflammatory response during liver transplantation, liver resections, and hypovolemic shock. The aim of this study was to evaluate the effects of hypertonic saline solution and the best timing of administration to prevent organ injury during experimental liver ischemia/reperfusion. Methods. Rats underwent 1 hr of warm liver ischemia followed by reperfusion. Eighty-four rats Were allocated into 6 groups: sham group, control of ischemia group) (C), pre-ischemia treated NaCl 0.9% (ISS) and NaCl 7.5% (HTS) groups, pre-repefusion ISS, and HTS groups. Blood and tissue samples were collected 4 hr after reperfusion. Results. HTS showed beneficial effects in prevention of live ischemia/reperfusion injury. HTS groups developed increases in AST and ALT levels that were significantly less than ISS groups; however, the HTS pre-reperfusion group showed levels significantly less than the HTS pre-ischemia group. No differences in IL-6 and IL-10 levels, were observed. A significant decrease in mitochondrial dysfunction as well as hepatic edema was observed in the HTS pre-reperfusion group. Pulmonary vascular permeability Was significantly less in the pre-reperfusion HTS group compared to the ISS group. No differences in myeloperoxidase activity were observed. The liver histologic score was significantly less in the pre-reperfusion HTS group compared to the pre-ischemia I-ITS group. Conclusion. HTS ameliorated local and systemic injuries in experimental liver ischemia/reperfusion. Infusion of HTS in the pre-reperfusion period may be an important adjunct to accomplish the best results. (Surgery 2010;147:415-23.)
Resumo:
OBJECTIVE: We report our results using Onyx HD-500 (Micro Therapeutics, Inc., Irvine, CA) in the endovascular treatment of wide-neck intracranial aneurysms, which have a high rate of incomplete occlusion and recanalization with platinum coils. METHODS: Sixty-nine patients with 84 aneurysms were treated. Most of the aneurysms were located in the anterior circulation (80 of 84 aneurysms), were unruptured (74 of 84 aneurysms), and were incidental. Ten presented with subarachnoid hemorrhage, and 15 were symptomatic. All aneurysms had wide necks (neck >4 mm and/or dome-to-neck ratio <1.5). Fifty aneurysms were small (<12 mm), 30 were large (12 to <25 mm) and 4 were giant. Angiographic follow-up was available for 65 of the 84 aneurysms at 6 months, for 31 of the 84 aneurysms at 18 months, and for 5 of the 84 aneurysms at 36 months. RESULTS: Complete aneurysm occlusion was seen in 65.5% of aneurysms on immediate control, in 84.6% at 6 months, and in 90.3% at 18 months. The rates of complete occlusion were 74%, 95.1%, and 95.2% for small aneurysms and 53.3%, 70%, and 80% for large aneurysms at the same follow-up periods. Progression from incomplete to complete occlusion was seen in 68.2% of all aneurysms, with a higher percentage in small aneurysms (90.9%). Aneurysm recanalization was observed in 3 patients (4.6%), with retreatment in 2 patients (3.3%). Procedural mortality was 2.9%. Overall morbidity was 7.2%. CONCLUSION: Onyx embolization of intracranial wide-neck aneurysms is safe and effective. Morbidity and mortality rates are similar to those of other current endovascular techniques. Larger samples and longer follow-up periods are necessary.
Resumo:
Introduction: In this study, we compared the dentoalveolar changes of Class II patients treated with Jones jig and pendulum appliances. Methods: The experimental group comprised 40 Class II malocclusion subjects, divided into 2 groups: group 1 consisted of 20 patients (11 boys, 9 girls) at a mean pretreatment age of 13.17 years, treated with the Jones jig appliance for 0.91 years; group 2 comprised 20 patients (8 boys, 12 grls) at a mean pretreatment age of 13.98 years, treated with the pendulum appliance for 1.18 years. Only active treatment time of molar distalization was evaluated in the predistalization and postdistalization lateral cephalograms. Molar, second premolar, and incisor angular and linear variables were obtained. The intergroup treatment changes in these variables were compared with independent t tests. Results: The maxillary second premolars showed greater mesial tipping and extrusion in the Jones jig group, indicating more anchorage loss during molar distalization with this appliance. The amounts and the monthly rates of molar distalization were similar in both groups. Conclusions: The Jones jig group showed greater mesial tipping and extrusion of the maxillary second premolars. The mean amounts and the monthly rates of first molar distalization were similar in both groups. (Am J Orthod Dentofacial Orthop 2009;135:336-42)
Resumo:
A new myxosporean species, Henneguya eirasi n. sp., is described parasitizing the gill filaments of Pseudoplatystoma corruscans and Pseudoplatystoma fasciatum (Siluriformes: Pimelodidae) caught in the Patanal Wetland of the state of Mato Grosso, Brazil. The parasite formed white, elongated plasmodia measuring up to 3 mm. Mature spores were ellipsoidal in the frontal view, measuring 37.1 +/- 1.8 mu m in total length, 12.9 +/- 0.8 mu m in body length, 3.4 +/- 0.3 mu m in width, 3.1 +/- 0.1 mu m in thickness and 24.6 +/- 2.2 mu m in the caudal process. Polar capsules were elongated and equal in size, measuring 5.4 +/- 0.5 mu m in length and 0.7 +/- 0.1 mu m in width. Polar filaments had 12-13 coils. Histopathological analysis revealed that the parasite developed in the sub-epithelial connective tissue of the gill filaments and the plasmodia were surrounded by a capsule of host connective tissue. The plasmodia caused slight compression of the adjacent tissues, but no inflammatory response was observed in the infection site. Ultrastructure analysis revealed a single plasmodial wall connected to the ectoplasmic zone through numerous pinocytotic canals. The plasmodial wall exhibited numerous projections and slightly electron-dense material was found in the ectoplasm next to the plasmodial wall, forming a line just below the wall. Partial sequencing of the 18S rDNA gene of H. eirasi n. sp. obtained from P. fasciatum resulted in a total of 1066 bp and this sequence did not match any of the Myxozoa available in the GenBank. Phylogenetic analysis revealed the Henneguya species clustering into clades following the order and family of the host fishes. H. eirasi n. sp. clustered alone in one clade, which was the basal unit for the clade composed of Henneguya species parasites of siluriform ictalurids. The prevalence of the parasite was 17.1% in both fish species examined. Parasite prevalence was not influenced by season, host sex or host size. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
In magnetic resonance imaging (MRI), either on human or animal studies, the main requirements for radiofrequency (RF) coils are to produce a homogeneous RF field while used as a transmitter coil and to have the best signal-to-noise ratio (SNR) while used as a receiver. Besides, they need to be easily frequency adjustable and have input impedance matching 50 Omega to several different load conditions. New theoretical and practical concepts are presented here for considerable enhancing of RF coil homogeneity for MRI experiments on small animals. To optimize field homogeneity, we have performed simulations using Blot and Savart law varying the coil`s window angle, achieving the optimum one. However, when the coil`s dimensions are the same order of the wave length and according to transmission line theory, differences in electrical length and effects of mutual inductances between adjacent strip conductors decrease both field homogeneity and SNR. The problematic interactions between strip conductors by means of mutual inductance were eliminated by inserting crossings at half electrical length, avoiding distortion on current density, thus eliminating sources of field inhomogeneity. Experimental results show that measured field maps and simulations are in good agreement. The new coil design, dubbed double-crossed saddle described here have field homogeneity and SNR superior than the linearly driven 8-rung birdcage coil. One of our major findings was that the effects of mutual inductance are more significant than differences in electrical length for this frequency and coil dimensions. In vitro images of a primate Cebus paela brain were acquired, confirming double-crossed saddle superiority. (C) 2010 Wiley Periodicals, Inc. Concepts Magn Reson Part B (Magn Reson Engineering) 37B: 193-201, 2010
Deciphering the role of the electrostatic interactions in the alpha-tropomyosin head-to-tail complex
Resumo:
Skeletal alpha-tropomyosin (Tm) is a dimeric coiled-coil protein that forms linear assemblies under low ionic strength conditions in vitro through head-to-tail interactions. A previously published NMR structure of the Tin head-to-tail complex revealed that it is formed by the insertion of the N-terminal coiled-coil of one molecule into a cleft formed by the separation of the helices at the C-terminus of a second molecule. To evaluate the contribution of charged residues to complex stability, we employed single and double-mutant Tm fragments in which specific charged residues were changed to alanine in head-to-tail binding assays, and the effects of the mutations were analyzed by thermodynamic double-mutant cycles and protein-protein docking. The results show that residues K5, K7, and D280 are essential to the stability of the complex. Though D2, K6, D275, and H276 are exposed to the solvent and do not participate in intermolecular contacts in the NMR structure, they may contribute to head-to-tail complex stability by modulating the stability of the helices at the Tm termini.
Resumo:
A cDNA coding for a Tenebrio molitor midgut protein named peritrophic membrane ancillary protein (PMAP) was cloned and sequenced. The complete cDNA codes for a protein of 595 amino acids with six insect-allergen-related-repeats that may be grouped in A (predicted globular)- and B (predicted nonglobular)-types forming an ABABAB structure. The PMAP-cDNA was expressed in Pichia pastoris and the recombinant protein (64 kDa) was purified to homogeneity and used to raise antibodies in rabbits. The specific antibody detected PMAP peptides (22 kDa) in the anterior and middle midgut tissue, luminal contents, peritrophic membrane and feces. These peptides derive from PMAP, as supported by mass spectrometry, and resemble those formed by the in vitro action of trypsin on recombinant PMAP. Both in vitro and in vivo PMAP processing seem to occur by attack of trypsin to susceptible bonds in the coils predicted to link AB pairs, thus releasing the putative functional AB structures. The AB-domain structure of PMAP is found in homologous proteins from several insect orders, except lepidopterans that have the apparently derived protein known as nitrile-specifier protein. Immunocytolocalization shows that PMAP is secreted by exocytosis and becomes entrapped in the glycocalyx, before being released into midgut contents. Circumstantial evidence suggests that PMAP-like proteins have a role in peritrophic membrane type 2 formation. (C) 2007 Elsevier Ltd. All rights reserved.
Resumo:
The aim of this work is to address the activation process of a high temperature shift (HTS) catalyst, composed of Fe2O3/Cr2O3/CuO, by analyzing it before activation (HTS-V) and after activation (HTS-A) using complementary characterization techniques. The textural and morphological characterizations were done by transmission electron rnicroscopy (TEM) and nitrogen physisorption at 77 K; crystallographic structure was confirmed by X-ray diffraction (XRD); electronic structure was analyzed by X-ray absorption spectroscopy (XAS) and the chemical composition of the catalyst`s surface was obtained by X-ray photoelectron spectroscopy (XPS). The investigation pointed out that the HTS-V catalyst presents good textural and morphological properties, which are not deeply affected by the activation process (sample HTS-A). The iron oxide phase in the HTS-V catalyst is hematite whereas in HTS-A catalyst is magnetite with Fe2+/Fe3+ ratio close to the expected value (0.5). For both samples, the Cr ions seem to be incorporated in the iron oxide lattice with higher concentration at particle surface. In the HTS-V catalyst, the Cu ions have oxidation number II and occupy in average distorted octahedral sites; after the activation, the Cu ions are partially reduced, suggesting that the reduction of the Cu species is complex. (C) 2007 Elsevier B.V. All rights reserved.