18 resultados para HELLER MYOTOMY
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)
Resumo:
Purpose: Achalasia of the esophagus is characterized by aperistalsis and incomplete relaxation of the lower esophageal sphincter in response to swallowing. The objective of the present study is to present the experience of a modified Heller myotomy via a laparoscopic approach for the treatment of children who had this condition. Methods: A retrospective review of medical records of all patients who underwent this procedure from 2000 to 2009 was performed. The procedure consisted of an extended esophagomyotomy beginning on the lower part of the lower esophageal sphincter and continuing 5 to 6 cm above on the lower third of the esophagus, and then extended 3 to 4 cm below to the stomach, associated with an anterior 180-degree hemi-fundoplication according to Dor`s technique. Results: Fifteen patients were included in the study. There were 8 female and 7 male patients. Mean operating time was 190 minutes with no intraoperative complications and 1 conversion to open surgery because of difficulty in dissecting an inflamed distal esophagus. In a mean follow-up period of 32.3 months, 2 patients had recurrence of mild dysphagia that disappeared spontaneously, and 1 required a single botulinum toxin injection with complete resolution of symptoms. Conclusion: We conclude that the laparoscopic extended Heller myotomy with Dor fundoplication is a safe and effective method for the treatment for achalasia in the pediatric population even in advanced cases. (C) 2010 Elsevier Inc. All rights reserved.
Resumo:
Chagas` disease (CD) is highly prevalent in South America. Brazilian surgeons and gastroenterologists gained valuable experience in the treatment of CD esophagopathy (chagasic achalasia) due to the high number of cases treated. The authors reviewed the lessons learned with the treatment of achalasia by different centers experienced in the treatment of Chagas` disease. Preoperative evaluation, endoscopic treatment (forceful dilatation and botulinum toxin injection), Heller`s myotomy, esophagectomy, conservative techniques other than myotomy, and reoperations are discussed in the light of personal experiences and review of International and Brazilian literature. Aspects not frequently adopted by North American and European surgeons are emphasized. The review shows that nonadvanced achalasia is frequently treated by Heller`s myotomy. Endoscopic treatment is reserved to limited cases. Treatment for end-stage achalasia is not unanimous. Esophagectomy was a popular treatment in advanced disease; however, the morbidity/mortality associated to the procedure made some authors seek different alternatives, such as Heller`s myotomy and cardioplasties. Minimally invasive approach to esophageal resection may change this concept, although few centers perform the procedure routinely.
Resumo:
Background: Treatment of excessive gingival display usually involves procedures such as Le Fort impaction or maxillary gingivectomies. The authors propose an alternative technique that reduces the muscular function of the elevator of the upper lip muscle and repositioning of the upper lip. Methods: Fourteen female patients with excessive gingival exposure were operated on between February of 2008 and March of 2009. They were filmed before and at least 6 months after the procedure. They were asked to perform their fullest smile, and the maximum gingival exposures were measured and analyzed using ImageJ software. Patients were operated on under local anesthesia. Their gingival mucosa was freed from the maxilla using a periosteum elevator. Skin and subcutaneous tissue were dissected bluntly from the underlying musculature of the upper lip. A frenuloplasty was performed to lengthen the upper lip. Both levator labii superioris muscles were dissected and divided. Results: The postoperative course was uneventful in all of the patients. The mean gingival exposure before surgery was 5.22 +/- 1.48 mm; 6 months after surgery, it was 1.91 +/- 1.50 mm. The mean gingival exposure reduction was 3.31 +/- 1.05 mm (p < 0.001), ranging from 1.59 to 4.83 mm. Conclusion: This study shows that the proposed technique was efficient in reducing the amount of exposed gum during smile in all patients in this series. (Plast. Reconstr. Surg. 126: 1014, 2010.)
Resumo:
In Tokamak Chauffage Alfven Bresilien [R. M. O. Galvao , Plasma Phys. Controlled Fusion 43, 1181 (2001)], high magnetohydrodynamic (MHD) activity may appear spontaneously or during discharges with a voltage biased electrode inserted at the plasma edge. The turbulent electrostatic fluctuations, measured by Langmuir probes, are modulated by Mirnov oscillations presenting a dominant peak with a common frequency around 10 kHz. We report the occurrence of phase locking of the turbulent potential fluctuations driven by MHD activity at this frequency. Using wavelet cross-spectral analysis, we characterized the phase and frequency synchronization in the plasma edge region. We introduced an order parameter to characterize the radial dependence of the phase-locking intensity. (c) 2008 American Institute of Physics.
Resumo:
This paper reports results from a search for nu(mu) -> nu(e) transitions by the MINOS experiment based on a 7 x 10(20) protons-on-target exposure. Our observation of 54 candidate nu(e) events in the far detector with a background of 49.1 +/- 7.0(stat) +/- 2.7(syst) events predicted by the measurements in the near detector requires 2sin(2)(2 theta(13))sin(2)theta(23) < 0.12(0.20) at the 90% C.L. for the normal (inverted) mass hierarchy at delta(CP) = 0. The experiment sets the tightest limits to date on the value of theta(13) for nearly all values of delta(CP) for the normal neutrino mass hierarchy and maximal sin(2)(2 theta(23)).
Resumo:
The energy dependence of the neutrino-iron and antineutrino-iron inclusive charged-current cross sections and their ratio have been measured using a high-statistics sample with the MINOS near detector exposed to the NuMI beam from the main injector at Fermilab. Neutrino and antineutrino fluxes were determined using a low hadronic energy subsample of charged-current events. We report measurements of nu-Fe ((nu) over bar - Fe) cross section in the energy range 3-50 GeV (5-50 GeV) with precision of 2%-8% (3%-9%) and their ratio which is measured with precision 2%-8%. The data set spans the region from low energy, where accurate measurements are sparse, up to the high-energy scaling region where the cross section is well understood.
Resumo:
A search for depletion of the combined flux of active neutrino species over a 735 km baseline is reported using neutral-current interaction data recorded by the MINOS detectors in the NuMI neutrino beam. Such a depletion is not expected according to conventional interpretations of neutrino oscillation data involving the three known neutrino flavors. A depletion would be a signature of oscillations or decay to postulated noninteracting sterile neutrinos, scenarios not ruled out by existing data. From an exposure of 3.18 x 10(20) protons on target in which neutrinos of energies between similar to 500 MeV and 120 GeV are produced predominantly as nu(mu), the visible energy spectrum of candidate neutral-current reactions in the MINOS far detector is reconstructed. Comparison of this spectrum to that inferred from a similarly selected near-detector sample shows that of the portion of the nu(mu) flux observed to disappear in charged-current interaction data, the fraction that could be converting to a sterile state is less than 52% at 90% confidence level (C. L.). The hypothesis that active neutrinos mix with a single sterile neutrino via oscillations is tested by fitting the data to various models. In the particular four-neutrino models considered, the mixing angles theta(24) and theta(34) are constrained to be less than 11 degrees and 56 degrees at 90% C. L., respectively. The possibility that active neutrinos may decay to sterile neutrinos is also investigated. Pure neutrino decay without oscillations is ruled out at 5.4 standard deviations. For the scenario in which active neutrinos decay into sterile states concurrently with neutrino oscillations, a lower limit is established for the neutrino decay lifetime tau(3)/m(3) > 2.1 x 10(-12) s/eV at 90% C.L.
Resumo:
The temperature of the upper atmosphere affects the height of primary cosmic ray interactions and the production of high-energy cosmic ray muons which can be detected deep underground. The MINOS far detector at Soudan, MN, has collected over 67 X 10(6) cosmic ray induced muons. The underground muon rate measured over a period of five years exhibits a 4% peak-to-peak seasonal variation which is highly correlated with the temperature in the upper atmosphere. The coefficient, alpha(T), relating changes in the muon rate to changes in atmospheric temperature was found to be alpha(T) 0: 873 +/- 0: 009(stat) +/- 0.010(syst). Pions and kaons in the primary hadronic interactions of cosmic rays in the atmosphere contribute differently to alpha(T) due to the different masses and lifetimes. This allows the measured value of alpha(T) to be interpreted as a measurement of the K/pi ratio for E(p) greater than or similar to 7 TeV of 0.12(-0.05)(+0.07), consistent with the expectation from collider experiments.
Resumo:
This Letter reports on a search for nu(mu)->nu(e) transitions by the MINOS experiment based on a 3.14x10(20) protons-on-target exposure in the Fermilab NuMI beam. We observe 35 events in the Far Detector with a background of 27 +/- 5(stat)+/- 2(syst) events predicted by the measurements in the Near Detector. If interpreted in terms of nu(mu)->nu(e) oscillations, this 1.5 sigma excess of events is consistent with sin(2)(2 theta(13)) comparable to the CHOOZ limit when |Delta m(2)|=2.43x10(-3) eV(2) and sin(2)(2 theta(23))=1.0 are assumed.
Resumo:
We report the first detailed comparisons of the rates and spectra of neutral-current neutrino interactions at two widely separated locations. A depletion in the rate at the far site would indicate mixing between nu(mu) and a sterile particle. No anomalous depletion in the reconstructed energy spectrum is observed. Assuming oscillations occur at a single mass-squared splitting, a fit to the neutral- and charged-current energy spectra limits the fraction of nu(mu) oscillating to a sterile neutrino to be below 0.68 at 90% confidence level. A less stringent limit due to a possible contribution to the measured neutral-current event rate at the far site from nu(e) appearance at the current experimental limit is also presented.
Resumo:
A search for a sidereal modulation in the MINOS near detector neutrino data was performed. If present, this signature could be a consequence of Lorentz and CPT violation as predicted by the effective field theory called the standard-model extension. No evidence for a sidereal signal in the data set was found, implying that there is no significant change in neutrino propagation that depends on the direction of the neutrino beam in a sun-centered inertial frame. Upper limits on the magnitudes of the Lorentz and CPT violating terms in the standard-model extension lie between 10(-4) and 10(-2) of the maximum expected, assuming a suppression of these signatures by a factor of 10(-17).
Resumo:
This Letter reports new results from the MINOS experiment based on a two-year exposure to muon neutrinos from the Fermilab NuMI beam. Our data are consistent with quantum-mechanical oscillations of neutrino flavor with mass splitting vertical bar Delta m(2)vertical bar = (2.43 +/- 0.13) x 10(-3) eV(2) (68% C.L.) and mixing angle sin(2)(2 theta) > 0.90 (90% C.L.). Our data disfavor two alternative explanations for the disappearance of neutrinos in flight: namely, neutrino decays into lighter particles and quantum decoherence of neutrinos, at the 3.7 and 5.7 standard-deviation levels, respectively.
Resumo:
This paper describes four new species of the bryozoan genus Beania from the Brazilian coast. Two of them have been previously recorded in the western Atlantic as Beania hirtissima (Heller, 1867) and Beania mirabilis Johnston, 1840, respectively; they are redescribed here as Beania americana n. sp. and Beania mirabilissima n. sp. Two reticulate species, Beania correiae n. sp. and Beania metrii n. sp., are newly described. Descriptions of four other species of Beania from the region are also included: Beania australis Busk, 1852, Beania cupulariensis Osburn, 1914, Beania klugei Cook, 1968 and Beania maxilladentata Ramalho, Muricy & Taylor, 2010.
Resumo:
Clinical applications of quantitative computed tomography (qCT) in patients with pulmonary opacifications are hindered by the radiation exposure and by the arduous manual image processing. We hypothesized that extrapolation from only ten thoracic CT sections will provide reliable information on the aeration of the entire lung. CTs of 72 patients with normal and 85 patients with opacified lungs were studied retrospectively. Volumes and masses of the lung and its differently aerated compartments were obtained from all CT sections. Then only the most cranial and caudal sections and a further eight evenly spaced sections between them were selected. The results from these ten sections were extrapolated to the entire lung. The agreement between both methods was assessed with Bland-Altman plots. Median (range) total lung volume and mass were 3,738 (1,311-6,768) ml and 957 (545-3,019) g, the corresponding bias (limits of agreement) were 26 (-42 to 95) ml and 8 (-21 to 38) g, respectively. The median volumes (range) of differently aerated compartments (percentage of total lung volume) were 1 (0-54)% for the nonaerated, 5 (1-44)% for the poorly aerated, 85 (28-98)% for the normally aerated, and 4 (0-48)% for the hyperaerated subvolume. The agreement between the extrapolated results and those from all CT sections was excellent. All bias values were below 1% of the total lung volume or mass, the limits of agreement never exceeded +/- 2%. The extrapolation method can reduce radiation exposure and shorten the time required for qCT analysis of lung aeration.
Resumo:
Whenever the surgeon uses the stomach as an esophageal substitute, either one of two techniques is generally performed: total gastric transposition or gastric tube esophagoplasty. No existing reports compare the complications associated with these two surgical procedures. The purpose of this study is to review the authors` experience with total gastric transposition and verify whether this technique is superior to gastric tube esophagoplasty in children by comparing the main complications with those reported in the publications of gastric tubes esophagoplasties in the English language literature published in the last 38 years. A total of 35 children underwent total gastric transposition according to the classical technique. Most of these patients (27, or 77.1%) had long gap esophageal atresia. The most frequently observed complications were compared to those reported in nine studies of gastric tube esophagoplasty comprising 184 patients. Mortality and graft failure rates were also compared. Seven patients (20.0%) presented with leaks, all of which closed spontaneously. Six children were reoperated, three experienced gastric outlet obstruction secondary to axial torsion of the stomach placed in the retrosternal space and the other three experienced delayed gastric emptying that required revision of the piloroplasty. There were two deaths (5.7%) and no graft failure. Strictures were observed in five patients (14.2%) and all of these were resolved with endoscopic dilatations. Six patients had diarrhea that spontaneously resolved. In the late follow-up period, all patients were on full feed and thriving well. The comparisons with gastric tube patients demonstrated that the total gastric transposition group presented with significantly less leaks and strictures (P = 0.0001 and 0.001, respectively). The incidence of death and graft failure was not statistically different. In conclusion, gastric transposition is as a simple technical procedure for esophageal replacement in children with satisfactory results, and is superior to gastric tube esophagoplasty.