57 resultados para False-negative Errors

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)


Relevância:

80.00% 80.00%

Publicador:

Resumo:

This article describes and discusses a method to determine root curvature radius by using cone-beam computed tomography (CBCT). The severity of root canal curvature is essential to select instrument and instrumentation technique. The diagnosis and planning of root canal treatment have traditionally been made based on periapical radiography. However, the higher accuracy of CBCT images to identify anatomic and pathologic alterations compared to panoramic and periapical radiographs has been shown to reduce the incidence of false-negative results. In high-resolution images, the measurement of root curvature radius can be obtained by circumcenter. Based on 3 mathematical points determined with the working tools of Planimp® software, it is possible to calculate root curvature radius in both apical and coronal directions. The CBCT-aided method for determination of root curvature radius presented in this article is easy to perform, reproducible and allows a more reliable and predictable endodontic planning, which reflects directly on a more efficacious preparation of curved root canals.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The objective of the current study was to evaluate the sensitivity, specificity and accuracy of fine needle aspiration biopsy (FNAB) of submucous nodules from the oral cavity and head and neck region as an auxiliary diagnostic tool. Fifty patients with nodule lesions in the oral cavity and the head and neck region were selected. All of them were submitted to FNAB and to either incisional or excisional biopsy. The diagnoses from the FNABs were compared with the biopsy diagnosis as the gold standard. All the cases of FNAB were analyzed by a single oral pathologist prior to the biopsy diagnosis. The results showed that the sensitivity of FNAB was 75%, its specificity was 96% and its accuracy was 58.8%. The false positive and false negative rates were 6.7% and 13.3%, respectively. The positive predictive value was 86% and the negative predictive value was 93%. The inconclusive rate was 16/50. FNAB displayed a high success rate for identifying both malignant and benign lesions, but a low accuracy for making a final diagnosis.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Alternative splicing of gene transcripts greatly expands the functional capacity of the genome, and certain splice isoforms may indicate specific disease states such as cancer. Splice junction microarrays interrogate thousands of splice junctions, but data analysis is difficult and error prone because of the increased complexity compared to differential gene expression analysis. We present Rank Change Detection (RCD) as a method to identify differential splicing events based upon a straightforward probabilistic model comparing the over-or underrepresentation of two or more competing isoforms. RCD has advantages over commonly used methods because it is robust to false positive errors due to nonlinear trends in microarray measurements. Further, RCD does not depend on prior knowledge of splice isoforms, yet it takes advantage of the inherent structure of mutually exclusive junctions, and it is conceptually generalizable to other types of splicing arrays or RNA-Seq. RCD specifically identifies the biologically important cases when a splice junction becomes more or less prevalent compared to other mutually exclusive junctions. The example data is from different cell lines of glioblastoma tumors assayed with Agilent microarrays.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Although the utility of the acetylcholinesterase (AChE) histochemistry on rectal suction biopsy in diagnosing Hirschsprung`s disease (HD) has been documented, few reports address a great number of biopsies and patients. Our aim is to present a 17-year experience on the method of rectal suction biopsy and AChE histochemical staining for diagnosis of intestinal dysganglionoses. Between August 1989 and July 2006, 297 children suspected of having HD were submitted to rectal suction biopsies that were evaluated by the same two surgeons. There were 18 complications (6.0%), namely one self-limited rectal bleeding and 17 (5.7%) inadequate procedures that were repeated. A total of 157 patients (52.8%) showed no increased AChE activity and the remaining patients (140-47.2.0%) presented patterns of increased AChE activity confirming the diagnosis of HD or neuronal intestinal dysplasia. Among the 140 cases suspected as having HD, in 131 children the diagnosis of HD was confirmed and they were operated on. The histological studies showed that 111 children presented the classic form of HD or a long spastic segment. Sixteen children presented total colonic aganglionosis and four children proved to have intestinal neuronal dysplasia, according to histological and radiological criteria. Nine (6.6%) newborns were identified as false-positives and no false-negative results were verified. The rectal suction biopsy combined with AChE staining is advantageous for the differentiation between normal bowel and intestinal dysganglionoses. The rectal suction method is simple and can easily be performed by experienced surgeons. The histological evaluation is very objective and can be performed by a non-pathologist.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVE. The purposes of this study were to use the myocardial delayed enhancement technique of cardiac MRI to investigate the frequency of unrecognized myocardial infarction (MI) in patients with end-stage renal disease, to compare the findings with those of ECG and SPECT, and to examine factors that may influence the utility of these methods in the detection of MI. SUBJECTS AND METHODS. We prospectively performed cardiac MRI, ECG, and SPECT to detect unrecognized MI in 72 patients with end-stage renal disease at high risk of coronary artery disease but without a clinical history of MI. RESULTS. Fifty-six patients (78%) were men ( mean age, 56.2 +/- 9.4 years) and 16 (22%) were women ( mean age, 55.8 +/- 11.4). The mean left ventricular mass index was 103.4 +/- 27.3 g/m(2), and the mean ejection fraction was 60.6% +/- 15.5%. Myocardial delayed enhancement imaging depicted unrecognized MI in 18 patients (25%). ECG findings were abnormal in five patients (7%), and SPECT findings were abnormal in 19 patients (26%). ECG findings were false-negative in 14 cases and false-positive in one case. The accuracy, sensitivity, and specificity of ECG were 79.2%, 22.2%, and 98.1% (p = 0.002). SPECT findings were false-negative in six cases and false-positive in seven cases. The accuracy, sensitivity, and specificity of SPECT were 81.9%, 66.7%, and 87.0% ( not significant). During a period of 4.9-77.9 months, 19 cardiac deaths were documented, but no statistical significance was found in survival analysis. CONCLUSION. Cardiac MRI with myocardial delayed enhancement can depict unrecognized MI in patients with end-stage renal disease. ECG and SPECT had low sensitivity in detection of MI. Infarct size and left ventricular mass can influence the utility of these methods in the detection of MI.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Tuberculosis has emerged as a major concern in patients with immuno-mediated diseases, including psoriasis, undergoing treatment with biologicals. However, it is not known whether the chronically activated immune system of psoriasis patients interferes with their Mycobacterium tuberculosis (Mtb)-specific immunity, especially in tuberculosis-endemic areas like Brazil. We evaluated T-cell responses to a Mtb lysate and to the recombinant Mtb proteins ESAT-6 and Ag85B of tuberculin skin test (TST) positive and TST negative patients with severe or mild/moderate, untreated psoriasis in three different assays: lymphocyte proliferation, enzyme immunoassay for interferon (IFN)-gamma and interleukin (IL)-10 production by peripheral blood mononuclear cells and overnight enzyme immunospot (ELISpot) for enumerating IFN-gamma-secreting cells. In our cohort, a low proportion (29%) of the severe psoriasis patients tested were TST-positive. IFN-gamma and IL-10 secretion and T-cell proliferation to Mtb antigens were reduced in TST-negative but not in TST-positive patients with severe psoriasis when compared to healthy controls with the same TST status. Similarly, severe psoriasis patients had decreased cytokine secretion and proliferative response to phytohemagglutinin. However, most psoriasis patients and healthy controls showed detectable numbers of IFN-gamma-secreting effector-memory T-cells in response to Mtb antigens by ELISpot. TST-negative, mild/moderate psoriasis patients had responses that were mostly intermediary between TST-negative controls and severe psoriasis patients. Thus, patients with severe psoriasis possess decreased anti-Mtb central memory T-cell responses, which may lead to false-negative results in the diagnosis of TB infection, but retain T-cell memory-effector activity against Mtb antigens. We hypothesize that the latter may confer some protection against tuberculosis reactivation.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Toxoplasma gondii causes severe disease both to man and livestock and its detection in meat after slaughtering requires PCR or biological tests. Meat packages contain retained exudate that could be used for serology due to its blood content. Similar studies reported false negative assays in those tests. We standardized an anti-T. gondii IgG ELISA in muscle juices from experimentally infected rabbits, with blood content determination by cyanhemoglobin spectrophotometry. IgG titers and immunoblotting profiles were similar in blood, serum or meat juice, after blood content correction. These assays were adequate regardless of the storage time up to 120 days or freeze-thaw cycles, without false negative results. We also found 1.35% (1/74) positive sample in commercial Brazilian rabbit meat cuts, by this assay. The blood content determination shows ELISA of meat juice may be useful for quality control for toxoplasmosis monitoring. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In this paper, methods are presented for automatic detection of the nipple and the pectoral muscle edge in mammograms via image processing in the Radon domain. Radon-domain information was used for the detection of straight-line candidates with high gradient. The longest straight-line candidate was used to identify the pectoral muscle edge. The nipple was detected as the convergence point of breast tissue components, indicated by the largest response in the Radon domain. Percentages of false-positive (FP) and false-negative (FN) areas were determined by comparing the areas of the pectoral muscle regions delimited manually by a radiologist and by the proposed method applied to 540 mediolateral-oblique (MLO) mammographic images. The average FP and FN were 8.99% and 9.13%, respectively. In the detection of the nipple, an average error of 7.4 mm was obtained with reference to the nipple as identified by a radiologist on 1,080 mammographic images (540 MLO and 540 craniocaudal views).

Relevância:

80.00% 80.00%

Publicador:

Resumo:

At present, the sporadic occurrence of human rabies in Brazil can be attributed primarily to dog- and vampire bat-related rabies viruses. Reverse transcription loop-mediated isothermal amplification (RT-LAMP) was employed as a simultaneous detection method for both rabies field variants within 60 min. Vampire bat-related rabies viruses could be distinguished from dog variants by digesting amplicons of the RT-LAMP reaction using the restriction enzyme Alwl. Amplification and digestion could both be completed within 120 min after RNA extraction. In addition, the RI-LAMP assay also detected rabies virus in isolates from Brazilian frugivorous bats and Ugandan dog, bovine and goat samples. In contrast, there were false negative results from several Brazilian insectivorous bats and all of Chinese dog, pig, and bovine samples using the RI-LAMP assay. This study showed that the RT-LAMP assay is effective for the rapid detection of rabies virus isolates from the primary reservoir in Brazil. Further improvements are necessary so that the RT-LAMP assay can be employed for the universal detection of genetic variants of rabies virus in the field. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The purpose of this study was to evaluate a new periapical index based on cone beam computed tomography (CBCT) for identification of apical periodontitis (AP). The periapical index proposed in this study (CBCTPAI) was developed on the basis of criteria established from measurements corresponding to periapical radiolucency interpreted on CBCT scans. Radiolucent images suggestive of periapical lesions were measured by using the working tools of Planimp software on CBCT scans in 3 dimensions: buccopalatal, mesiodistal, and diagonal. The CBCTPAI was determined by the largest lesion extension. A 6-point (0-5) scoring system was used with 2 additional variables, expansion of cortical bone and destruction of cortical bone. A total of 1014 images (periapical radiographs and CBCT scans) originally taken from 596 patients were evaluated by 3 observers by using the CBCTPAI criteria. AP was identified in 39.5% and 60.9% of cases by radiography and CBCT, respectively (P<.01). The CBCTPAI offers an accurate diagnostic method for use with high-resolution images, which can reduce the incidence of false-negative diagnosis, minimize observer interference, and increase the reliability of epidemiologic studies, especially those referring to AP prevalence and severity. (J Endod 2008;34:1325-1331)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The performance of the rapid slide agglutination test, with and without 2-mercaptoethanol (RSAT and 2ME-RSAT) and agar gel immunodiffusion test (AGID) was evaluated for the diagnosis of brucellosis in naturally infected dogs. The microbiological culture, PCR and clinical parameters were used as reference. A total of 167 dogs were clinically examined and tested by blood culture, culture of semen/vaginal swab and PCR in blood and semen/vaginal swab. According to the results observed the 167 dogs were divided into three groups: Brucella canis infected dogs (Group 1). B. canis non-infected dogs (Group 2) and dogs with suspected brucellosis (Group 3). The dogs were then tested by RSAT, 2ME-RSAT and AGID. Groups 1 and 2 were used to calculate the diagnostic sensitivity and specificity of the serological tests and the results observed in Group 3 were also discussed. The diagnostic sensitivity of RSAT, 2ME-RSAT and AGID was respectively 70.58%, 31.76%, and 52.94%. The diagnostic specificity of RSAT, 2ME-RSAT and AGID was respectively 83.34%, 100%, and 100%. In dogs with suspected brucellosis 15% were RSAT positive, none was 2ME-RSAT positive and 5% were AGID positive. Although the serological tests are the most commonly used methods for brucellosis diagnosis, a significant proportion of false-negative results were observed highlighting the importance of the direct methods of diagnosis, like blood culture and PCR to improve the diagnosis of canine brucellosis. (c) 2008 Elsevier Ltd. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Sampling protocols for detecting Salmonella on poultry differ among various countries. In the United States, the U.S. Department of Agriculture Food Safety and Inspection Service dictates that whole broiler carcasses should be rinsed with 400 ml of 1% buffered peptone water, whereas in the European Union 25-g samples composed of neck skin from three carcasses are evaluated. The purpose of this study was to evaluate a whole carcass rinse (WCR) and a neck skin excision (NS) procedure for Salmonella and Escherichia coli isolation from the same broiler carcass. Carcasses were obtained from three broiler processing plants. The skin around the neck area was aseptically removed and bagged separately from the carcass, and microbiological analysis was performed. The corresponding carcass was bagged and a WCR sample was evaluated. No significant difference (alpha <= 0.05) in Salmonella prevalence was found between the samples processed by the two methods, but both procedures produced many false-negative Salmonella results. Prechill, 37% (66 carcasses), 28% (50 carcasses), and 51% (91 carcasses) of the 180 carcasses examined were positive for Salmonella by WCR, NS, and both procedures combined, respectively. Postchill, 3% (5 carcasses), 7% (12 carcasses), and 10% (17 carcasses) of the 177 carcasses examined were positive for Salmonella by the WCR, NS, and combination of both procedures, respectively. Prechill, E. coli plus coliform counts were 3.0 and 2.6 log CFU/ml by the WCR and NS methods, respectively. Postchill. E. coli plus coliform counts were 1.7 and 1.4 log CFU/ml by the WCR and NS methods, respectively.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: There are several studies in the literature depicting measurement error in gene expression data and also, several others about regulatory network models. However, only a little fraction describes a combination of measurement error in mathematical regulatory networks and shows how to identify these networks under different rates of noise. Results: This article investigates the effects of measurement error on the estimation of the parameters in regulatory networks. Simulation studies indicate that, in both time series (dependent) and non-time series (independent) data, the measurement error strongly affects the estimated parameters of the regulatory network models, biasing them as predicted by the theory. Moreover, when testing the parameters of the regulatory network models, p-values computed by ignoring the measurement error are not reliable, since the rate of false positives are not controlled under the null hypothesis. In order to overcome these problems, we present an improved version of the Ordinary Least Square estimator in independent (regression models) and dependent (autoregressive models) data when the variables are subject to noises. Moreover, measurement error estimation procedures for microarrays are also described. Simulation results also show that both corrected methods perform better than the standard ones (i.e., ignoring measurement error). The proposed methodologies are illustrated using microarray data from lung cancer patients and mouse liver time series data. Conclusions: Measurement error dangerously affects the identification of regulatory network models, thus, they must be reduced or taken into account in order to avoid erroneous conclusions. This could be one of the reasons for high biological false positive rates identified in actual regulatory network models.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The divided visual field technique was used to investigate the pattern of brain asymmetry in the perception of positive/approach and negative/withdrawal facial expressions. A total of 80 undergraduate students (65 female, 15 male) were distributed in five experimental groups in order to investigate separately the perception of expressions of happiness, surprise, fear, sadness, and the neutral face. In each trial a target and a distractor expression were presented simultaneously in a computer screen for 150 ms and participants had to determine the side (left or right) on which the target expression was presented. Results indicated that expressions of happiness and fear were identified faster when presented in the left visual field, suggesting an advantage of the right hemisphere in the perception of these expressions. Fewer judgement errors and faster reaction times were also observed for the matching condition in which emotional faces were presented in the left visual field and neutral faces in the right visual field. Other results indicated that positive expressions (happiness and surprise) were perceived faster and more accurately than negative ones (sadness and fear). Main results tend to support the right hemisphere hypothesis, which predicts a better performance of the right hemisphere to perceive emotions, as opposed to the approach-withdrawal hypothesis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Um total de 109 cepas de Staphylococci coagulase-negativa foi isolado de leite de vacas com mastite clínica e subclínica, em 35 fazendas, situadas em nove estados brasileiros, no período de fevereiro a maio de 2005. Os isolados foram investigados em relação a susceptibilidade in vitro a diversos agentes antimicrobianos. A resistência à penicilina foi a observação mais freqüente (93,5%), seguida por sulfonamida (88,9%), novobiocina (88,6%) e ampicilina (85,3%). Todas as cepas examinadas mostraram resistência a pelo menos uma das drogas antimicrobianas testadas. Cepas apresentando resistência múltipla foram extremamente comuns, com 10,0% dos microrganismos isolados apresentando resistência a todas as drogas antimicrobianas. Os resultados obtidos indicaram que as cepas de Staphylococci coagulase-negativas, isoladas no Brasil, apresentaram um alto grau de resistência a antimicrobianos. Estes resultados são, provavelmente, uma conseqüência da pressão devida ao uso intensivo de drogas antimicrobianas.