34 resultados para External combustion engines.
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)
Resumo:
The flow in the automotive catalytic converter is, in general, not uniform. This significantly affects cost, service life, and performance, in particular, during cold startup. The current paper reports on a device that provided a large improvement in flow uniformity. The device is to be placed in the converter inlet diffuser and is constructed out of ordinary screens. It is cheap and easy to install. Moreover, the device does not present most of the undesired effects, such as increase in pressure drop and time to light off, often observed in other devices developed for the same purpose.
Resumo:
Daytime fatigue and lack of sleep seem to increase throughout adolescent years. Several environmental, psychological, and biological factors have been associated with the development of sleep across adolescence. The aim of the present article is to summarize these factors and to give examples of various outcomes in sleep patterns among adolescents studied in different cultural settings. It is obvious from earlier work that many adolescents have displaced circadian rhythms and lack of adaptation to school hours due to an early school start or additional burdens for work. Several interventions have aimed to help the adaptation process by supporting sleep processes and changing scheduling, in this way promoting classroom alertness. In summary, adolescents worldwide shorten their sleep due to schoolwork hours and additional work, especially by disturbing their sleep due to circadian misalignment
Resumo:
We examine, in the imaginary-time formalism, the high temperature behavior of n-point thermal loops in static Yang-Mills and gravitational fields. We show that in this regime, any hard thermal loop gives the same leading contribution as the one obtained by evaluating the loop integral at zero external energies and momenta.
Resumo:
In a U(1)(*)-noncommutative gauge field theory we extend the Seiberg-Witten map to include the (gauge-invariance-violating) external current and formulate-to the first order in the noncommutative parameter-gauge-covariant classical field equations. We find solutions to these equations in the vacuum and in an external magnetic field, when the 4-current is a static electric charge of a finite size a, restricted from below by the elementary length. We impose extra boundary conditions, which we use to rule out all singularities, 1/r included, from the solutions. The static charge proves to be a magnetic dipole, with its magnetic moment being inversely proportional to its size a. The external magnetic field modifies the long-range Coulomb field and some electromagnetic form factors. We also analyze the ambiguity in the Seiberg-Witten map and show that at least to the order studied here it is equivalent to the ambiguity of adding a homogeneous solution to the current-conservation equation.
Resumo:
We examined effects of attentional focus on swimming speed. Participants` task was to swim one length of a pool (16 m) using the front crawl stroke. In Experiment 1, intermediate swimmers were given attentional focus instructions related to the crawl arm stroke or the leg kick, respectively. Participants were instructed to focus on ""pulling your hands back"" or ""pushing the instep down"" (internal focus), or on ""pushing the water back/down"" (external focus), respectively. Swim times were significantly shorter with an external focus. In Experiment 2, a control condition was included. Times were significantly faster in the external focus compared with both the internal focus and control conditions. These findings have implications for enhancing performance in swimming.
Resumo:
A novel methodology to assess the risk of power transformer failures caused by external faults, such as short-circuit, taking the paper insulation condition into account, is presented. The risk index is obtained by contrasting the insulation paper condition with the probability that the transformer withstands the short-circuit current flowing along the winding during an external fault. In order to assess the risk, this probability and the value of the degree of polymerization of the insulating paper are regarded as inputs of a type-2 fuzzy logic system (T2-FLS), which computes the fuzzy risk level. A Monte Carlo simulation has been used to find the survival function of the currents flowing through the transformer winding during a single-phase or a three-phase short-circuit. The Roy Billinton Test System and a real power system have been used to test the results. (C) 2008 Elsevier B.V. All rights reserved.
Resumo:
An investigation was conducted on pollutants emitted from steady-state, steady-flow gasification and combustion of polyethylene (PE) in a two-stage furnace. The polymer, in pulverized form, was first pyrolyzed at 1000 degrees C, and subsequently, its gaseous pyrolyzates were burned, upon mixing with air at high temperatures (900-1100 degrees C). The motivation for this indirect type of burning PE was to attain nominally premixed combustion of the pyrolyzate gases with air, thereby achieving lower pollutant emissions than those emanating from the direct burning of the solid PE polymer. This work assessed the effluents of the two-stage furnace and examined the effects of the combustion temperature, as well as the polymer feed rate and the associated fuel/air equivalence ratio (0.3 < phi < 1.4). It was found that, whereas the yield of pyrolysis gas decreased with an increasing polymer feed rate, its composition was nearly independent of the feed rate. CO2 emissions peaked at an equivalence ratio near unity, while the CO emissions increased with an increasing equivalence ratio. The total light volatile hydrocarbon and semivolatile polycyclic aromatic hydrocarbon (PAH) emissions of combustion increased with an increasing equivalence ratio. The generated particulates were mostly submicrometer in size. Overall, PAH and soot emissions from this indirect burning of PE were an order of magnitude lower than corresponding emissions from the direct burning of the solid polymer, obtained previously in this laboratory using identical sampling and analytical techniques. Because pyrolysis of this polymer requires a nominal heat input that amounts to only a diminutive fraction of the heat released during its combustion, implementation of this technique is deemed advantageous.
Resumo:
This work reports on the synthesis, characterization and applications of the new cerium(III) beta-diketonate Ce(hdacac)(3)(Hhdacac)(3)center dot 2H(2)O (where hdacac and Hhdacac denote, respectively, the hexadecylpentane-2,4-dionate and hexadecylpentane-2,4-dione ligands) as catalyst for the reduction of automotive emissions. Due to its amphiphilic character, this complex can be solubilized in non-polar fuels, thus generating cerium(IV) oxide particles, which efficiently catalyze the oxidation of diesel/biodiesel soot. The synthesized complex was characterized by microanalysis (C, H), thermal analysis, and infrared spectroscopy. Scanning electron microscopy, X-ray diffractometry, and specific surface area measurements attested that the complex can act as a soluble precursor of homogeneous CeO(2) spherical nanoparticles. The efficiency of this compound as catalyst for the reduction of soot emission was evaluated through static studies (comprising carbon black oxidation), which confirmed that increasing concentrations of the complex result in lower carbon black oxidation temperatures and lower activation Gibbs free energies. Dynamic studies, which embraced the combustion of diesel/biodiesel blends containing different amounts of the solubilized complex in a stationary motor, allowed a comparative evaluation of the soot emission through diffuse reflectance spectroscopy. These analyses provided very emphatic evidences of the efficiency of this new cerium complex for the control of soot emission in diesel/biodiesel motors. (c) 2009 Published by Elsevier B.V.
Resumo:
Background Women with 21-hydroxylase deficiency present much variability in external genitalia virilization, even among those with similar impairments of 21-hydroxylase (21OH) activity. Objective To evaluate if the number of CAG (nCAG) repeats of the androgen receptor gene influences the degree of external genitalia virilization in women with CYP21A2 mutations, grouped according to impairment of 21OH activity. Patients The nCAG was determined in 106 congenital adrenal hyperplasia (CAH) patients and in 302 controls. The patients were divided, according to their CYP21A2 genotypes, into Groups A and B, which confer total and severe impairment of 21OH activity, respectively. Methods The inactivation pattern of the X-chromosome was studied through genomic DNA digestion with Hpa II. The CAG repeat region was amplified by polymerase chain reaction (PCR) and analysed by GeneScan. Results The nCAG and the frequency of severe skewed X-inactivation did not differ between normal women and patients. The nCAG median in genotype A was 20.7 (IQR 2.3) for Prader I + II, 22.5 (3.6) for Prader III and 21 (2.9) for Prader IV + V (P < 0.05 for Prader III and Prader IV + V). The nCAG median in genotype B was 21.3 (1.1) for Prader I + II, 20.5 (2.9) for Prader III and 22 (2.8) for Prader IV + V (P > 0.05). A significant difference was found regarding the nCAG median in patients presenting Prader III from genotypes A and B. Conclusions We observed great variability in the degree of external genitalia virilization in both CYP21A2 genotypes, and we showed that the CAG repeats of the androgen receptor gene influences this phenotypic variability.
Resumo:
Background and purpose: To evaluate biochemical control and treatment related toxicity of patients with localized adenocarcinoma of the prostate treated with high dose-rate brachytherapy (HDRB) combined with conventional 2D or 3D-conformal external beam irradiation (EBI). Material and methods: Four-hundred and three patients treated between December 2000 and March 2004. HDRB was delivered with three fractions of 5.5-7 Gy with a single implant, followed by 45 Gy delivered with 2D or 3D conformal EBI. Results: The median follow-up was 48.4 months. Biochemical failure (BF) occurred in 9.6% according to both ASTRO and Phoenix consensus criteria. Mean time to relapse was 13 and 26 months, respectively. The 5-year BF free survival using the ASTRO criteria was 94.3%, 86.9% and 86.6% for the low, intermediate and high risk groups, respectively; using Phoenix criteria, 92.4%, 88.0% and 85.3%, respectively. The only predictive factor of BF in the multivariate analysis by both ASTRO and Phoenix criteria was the presence of prostate nodules detected by digital palpation, and patients younger than 60 years presented a higher chance of failure using Phoenix criteria only. Conclusions: Treatment scheme is feasible and safe with good efficacy. (C) 2011 Elsevier Ireland Ltd All rights reserved. Radiotherapy and Oncology 98 (2011) 169-174
Resumo:
To describe incidence rates and risk factors associated with external ventricular drain (EVD)-related infections at a tertiary Brazilian teaching hospital. The patient cohort consisted of all patients at a major teaching hospital in Brazil with an EVD during the period 1 April 2007 to 30 June 2008 (15 months). Patients were followed up for 30 days after catheter removal. According to the Center for Diseases Control and Prevention criteria for meningitis/ventriculitis, all of the central nervous system (CNS) infections that occurred during this period could be considered to be meningitis or ventriculitis related to EVD placement. Infection rates were calculated using different denominators, such as (1) per patient (incidence), (2) per procedure, and (3) per 1,000 catheter-days (drain-associated infection rate). Patient demographic data, medical history of underlying diseases, antibiotic prophylaxis usage, American Society of Anesthesiologists Score classification, duration of surgery and hospitalization, length of time the EVD was in place, and overall mortality were evaluated during the study period. A logistic regression model was developed to identify factors associated with infection. A total of 119 patients, 130 EVD procedures, and 839 catheter-days were evaluated. The incidence of infection was 18.3%, the infection rate was 16.9% per procedure, and the drain-associated infection rate was 22.4 per 1,000 catheter-days; 77% of the infections were caused by Gram-negative micro-organisms. Only 75% of patients received antibiotic prophylaxis. The infection rate increased with length of the hospital stay. The length of time the catheter was in place was the only independent risk factor associated with infection (p = 0.0369). The incidence of EVD-related infections is high in our hospital, Gram-negative micro-organisms were the most frequent causal agents identified and length of time that the catheter was in place contributed to the infection rate.
Resumo:
Background/Purpose: Central venous catheterization is among the most common procedures performed by pediatric surgeons. Significant morbidity and even mortality can ensue from the widespread approach to the deep veins of the neck and femoral region. The external jugular vein (EJV) is a low-morbidity alternative for percutaneous catheterization in children, but it has yielded a low success rate in previous reports The authors show an improved success rate with this option. Methods: We performed an analysis of 33 patients` charts in which central venous catheterization using Seldinger technique through the EJV was attempted in 2005. Age, diagnosis, maneuvers used for success, fluoroscopy usefulness, and types of inserted catheters were evaluated. Results: The procedure was successful in 26 (78.8%) patients without complications. Diagnosis was neoplasia in almost half of the patients (42%). In half of the successful cases, body maneuvers were used, namely, twisting the head of the patient to the side of the vein and stretching the ipsilateral arm and shoulder. All but one procedure were completed under fluoroscopic guidance. In 6 (23%) patients, a long-term catheter was inserted. Conclusions: The EJV is an excellent option for central venous catheterization in children. The execution of simple maneuvers along with fluoroscopic assistance might allow for an improved success rate not only for short-term but also for long-term catheter insertion. (C) 2008 Elsevier Inc. All rights reserved.
Resumo:
A risk score model was developed based in a population of 1,224 individuals from the general population without known diabetes aging 35 years or more from an urban Brazilian population sample in order to select individuals who should be screened in subsequent testing and improve the efficacy of public health assurance. External validation was performed in a second, independent, population from a different city ascertained through a similar epidemiological protocol. The risk score was developed by multiple logistic regression and model performance and cutoff values were derived from a receiver operating characteristic curve. Model`s capacity of predicting fasting blood glucose levels was tested analyzing data from a 5-year follow-up protocol conducted in the general population. Items independently and significantly associated with diabetes were age, BMI and known hypertension. Sensitivity, specificity and proportion of further testing necessary for the best cutoff value were 75.9, 66.9 and 37.2%, respectively. External validation confirmed the model`s adequacy (AUC equal to 0.72). Finally, model score was also capable of predicting fasting blood glucose progression in non-diabetic individuals in a 5-year follow-up period. In conclusion, this simple diabetes risk score was able to identify individuals with an increased likelihood of having diabetes and it can be used to stratify subpopulations in which performing of subsequent tests is necessary and probably cost-effective.
Resumo:
Radiotherapy following breast cancer conserving surgery decreases the risks of local recurrence. Because 85% of breast cancers relapse in or around the surgical bed there has been some debate on the need for irradiating the whole breast. Electron intraoperative radiotherapy (ELIOT) has been used as a viable alternative for conventional external radiotherapy (RT). While the former requires a single dose of 21 Gy in the tumoral bed, the latter requires 5-6 weeks of irradiation with a total dose of 50 Gy and a boost of 10 Gy that irradiates the surgical bed. Herein, we investigated whether any significant differences exist between the mammography findings obtained from patients submitted to one of the two techniques. Two groups of 30 patients each were included in this study. All patients had mammographies taken at 12 and 24 months after finishing treatment. The mammography findings evaluated were: cutaneous thickening (>2 mm), architectural distortion secondary to fibrosis, edema, calcifications (both benign and malignant), and fat necrosis. For all variables studied, there was no statistical difference between the two groups. This indicates that the mammography findings obtained in either 12- or 24-month follow-up periods after breast cancer conserving surgery are similar, regardless of which of the two radiotherapy techniques (ELIOT or RT) is employed as a treatment for breast cancer. (C) 2010 Published by Elsevier Ireland Ltd.
Resumo:
An 8-month-old child presented with a right pulsatile neck mass. The tumor`s rapid increase in size and respiratory problems prompted image evaluation. An external carotid artery aneurysm was found, which was compressing other neck structures. The patient underwent aneurysm resection and ligation at its insertion on the common carotid artery. Recovery was uneventful and no further aneurysms on other arteries were found.