6 resultados para Ex-prisoners
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)
Resumo:
The purpose of this study was to evaluate ex vivo the accuracy an electronic apex locator during root canal length determination in primary molars. Methods: One calibrated examiner determined the root canal length in 15 primary molars (total=34 root canals) with different stages of root resorption. Root canal length was measured both visually, with the placement of a K-file 1 mm short of the apical foramen or the apical resorption bevel, and electronically using an electronic apex locator (Digital Signal Processing). Data were analyzed statistically using the intraclass correlation (ICC) test. Results: Comparing the actual and electronic root canal length measurements in the primary teeth showed a high correlation (ICC=0.95) Conclusions: The Digital Signal Processing apex locator is useful and accurate for apex foramen location during root canal length measurement in primary molars. (Pediatr Dent 200937:320-2) Received April 75, 2008 vertical bar Lost Revision August 21, 2008 vertical bar Revision Accepted August 22, 2008
Resumo:
Aim To evaluate ex vivo the accuracy of two electronic apex locators during root canal length determination in primary incisor and molar teeth with different stages of physiological root resorption. Methodology One calibrated examiner determined the root canal length in 17 primary incisors and 16 primary molars (total of 57 root canals) with different stages of root resorption based on the actual canal length and using two electronic apex locators. Root canal length was measured both visually, with the placement of a K-file 1 mm short of the apical foramen or the apical resorption bevel, and electronically using two electronic apex locators (Root ZX II - J. Morita Corp. and Mini Apex Locator - SybronEndo) according to the manufacturers` instructions. Data were analysed statistically using the intraclass correlation (ICC) test. Results Comparison of the actual root canal length and the electronic root canal length measurements revealed high correlation (ICC = 0.99), regardless of the tooth type (single-rooted and multi-rooted teeth) or the presence/absence of physiological root resorption. Conclusions Root ZX II and Mini Apex Locator proved useful and accurate for apex foramen location during root canal length measurement in primary incisors and molars.
Resumo:
P>Aim To evaluate ex vivo the accuracy of the iPex multi-frequency electronic apex locator (NSK Ltd, Tokyo, Japan) for working length determination in primary molar teeth. Methodology One calibrated examiner determined the working length in 20 primary molar teeth (total of 33 root canals). Working length was measured both visually, with the placement of a K-file 1 mm short of the apical foramen or the most coronal limit of root resorption, and electronically using the electronic apex locator iPex, according to the manufacturers` instructions. Data were analysed statistically using the intraclass correlation (ICC) test. Results Comparison of the actual and the electronic measurements revealed high correlation (ICC = 0.99) between the methods, regardless of the presence or absence of physiological root resorption. Conclusions In this laboratory study, the iPex accurately identified the apical foramen or the apical opening location for working length measurement in primary molar teeth.
Resumo:
(Nectandra Rol. ex Rottb. (Lauraceae) in Mato Grosso do Sul State, Brazil). This paper presents the taxonomic study of the species of Nectandra from Mato Grosso do Sul. Eight species of Nectandra were identified through the morphological analyses of specimens collected in different regions from the State: N. amazonum Nees, N. cissiflora Nees, N. cuspidata Nees, N. falcifolia (Nees) J.A. Castigl. ex Mart. Crov. & Piccinini, N. gardneri Meisn., N. hihua (Ruiz & Pav.) Rohwer, N. megapotamica (Spreng.) Mez and N. psammophila Nees. Identification key, morphological descriptions, geographic distribution, habitat, fenologic aspect, taxonomic comments, and illustrations are presented.
Resumo:
A new genus and species of Normanellidae (Copepoda, Harpacticoida), Paranaiara inajae gen. et sp. nov., is described from the continental shelf off the northern coast of Sao Paulo State, Brazil. The new genus differs from the type genus Normanella Brady, 1880 and Sagamiella Lee & Huys, 1999 in its presence of lamelliform caudal rami, a maxillulary endopod represented by 2 setae, an unarmed maxillipedal syncoxa, and reduced setation on P2 enp-2 (without outer spine) and P3 enp-2 (with only 2 inner setae). All these apomorphic character states are shared with the genus Pseudocletodes Scott & Scott, 1893, formerly placed in the family Nannopodidae (ex Huntemanniidae) and here assigned to the Normanellidae. Pseudocletodes can be differentiated from Paranaiara by the loss of the P1 endopod and of the inner seta on P2-P4 enp-1, the presence of only 2 inner setae on P2 enp-2 (instead of 3) and only 1 inner seta on P4 exp-3 (instead of 2), the presence of a second inner seta on P4 enp-2 (instead of 1), the morphology of the fifth pair of legs which are not medially fused and have only 3 endopodal elements (instead of 4) in the male, and the well developed caudal ramus seta V (instead of rudimentary). It is postulated that prehensility of the P1 endopod was secondarily lost in the common ancestor of Paranaiara and Pseudocletodes. An updated family diagnosis of the Normanellidae and a dichotomous identification key to the 22 currently valid species are presented.
Resumo:
Scanning electrochemical microscopy (SECM) in feedback mode was employed to characterise the reactivity and microscopic peculiarities of bismuth and bismuth/lead alloys plated onto gold disk substrates in 0.1 molL(-1) NaOH solutions. Methyl viologen was used as redox mediator, while a platinum microelectrode was employed as the SECM tip. The metal films were electrodeposited ex situ from NaOH solutions containing either bismuth ions only or both bismuth and lead ions. Approach curves and SECM images indicated that the metal films were conductive and locally reactive with oxygen to provide Bi(3+) and Pb(2+) ions. The occurrence of the latter chemical reactions was verified by local anodic stripping voltammetry (ASV) at the substrate solution interface by using a mercury-coated platinum SECM tip. The latter types of measurements allowed also verifying that lead was not uniformly distributed onto the bismuth film electrode substrate. These findings were confirmed by scanning electron microscopy images. The surface heterogeneity produced during the metal deposition process, however, did not affect the analytical performance of the bismuth coated gold electrode in anodic stripping voltammetry for the determination of lead in alkaline media, even in aerated aqueous solutions. Under the latter conditions, stripping peak currents proportional to lead concentration with a satisfactory reproducibility (within 5% RSD) were obtained.