129 resultados para Endoscopic band removal

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: One of the complications of laparoscopic adjustable gastric banding is intragastric erosion, leading to a revisional procedure to remove the band. Our aim was to present the procedure and results of endoscopic band removal in a 5-year multicenter experience from the Gastro Obeso Center and Universidade de Sao Paulo, Sao Paulo, and Universidade Federal de Pernambuco, Recite, Brazil. Methods: From 2003 to 2008, 82 patients were diagnosed with band erosion. The clinical data concerning the endoscopic procedure were prospectively recorded and retrospectively reviewed. Results: The average preoperative body mass index was 43.2 kg/m(2) (range 34-50). At the diagnosis of intragastric erosion, the body mass index was 24-41 kg/m(2) (average 31.8). The erosion occurred an average of 16.3 months (range 6-36) postoperatively. The symptoms included pain in 25 (31%), port infection in 21 patients (27%), and weight regain in 20 (25%), and 12 patients (15%) were asymptomatic. Endoscopic removal was possible for 78 patients (95%). In 85% of patients, the band was removed in the first session, with an average duration of 55 minutes (range 25-150). Five cases of pneumoperitoneum occurred after the procedure. Of these, 3 were treated conservatively, 1 was treated by laparoscopy, and I was treated by abdominal puncture using the Veress needle. Conclusion: Endoscopic removal of eroded laparoscopic adjustable gastric banding is safe and effective. It can be used as a first choice procedure in clinical practice. (Surg Obes Relat Dis 2010; 6:423-428.) (C) 2010 American Society for Metabolic and Bariatric Surgery. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The local-density approximation (LDA) together with the half occupation (transitionstate) is notoriously successful in the calculation of atomic ionization potentials. When it comes to extended systems, such as a semiconductor infinite system, it has been very difficult to find a way to half ionize because the hole tends to be infinitely extended (a Bloch wave). The answer to this problem lies in the LDA formalism itself. One proves that the half occupation is equivalent to introducing the hole self-energy (electrostatic and exchange correlation) into the Schrodinger equation. The argument then becomes simple: The eigenvalue minus the self-energy has to be minimized because the atom has a minimal energy. Then one simply proves that the hole is localized, not infinitely extended, because it must have maximal self-energy. Then one also arrives at an equation similar to the self- interaction correction equation, but corrected for the removal of just 1/2 electron. Applied to the calculation of band gaps and effective masses, we use the self- energy calculated in atoms and attain a precision similar to that of GW, but with the great advantage that it requires no more computational effort than standard LDA.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Silastic rings are used in gastric bypass procedures for the treatment of obesity, but ring slippage may lead to gastric pouch outlet stenosis (GPOS). Conventional management has been ring removal through abdominal surgery. Objective: To describe a novel, safe, minimally invasive, endoscopic technique for the treatment of GPOS caused by ring slippage after gastric bypass. Design: Case series. Setting: Federal University of Pernambuco and sao Paulo University. Patients: This study involved 39 consecutive patients who-were screened for inclusion. Intervention: Endoscopic dilation with an achalasia balloon. Main Outcome Measurements: Technical success and safety of the procedure. Results: Among the 39 patients, 35 underwent endoscopic dilation at the ring slippage site for the relief of GPOS. The 4 patients who did not undergo endoscopic dilation underwent surgical removal of the ring, based on the exclusion criteria. The endoscopic approach was successful in 1 to 4 sessions in 100% of cases with radioscopic control (n = 12). The duration of the procedures ranged from 5 to 30 minutes, and the average internment was 14.4 hours. Dilation promoted either rupture (65.7%) or stretching (34.3%) of the thread within the ring, thereby increasing the luminal diameter of the GPOS. Complications included self-limited upper digestive tract hemorrhage (n = 1) and asymptomatic ring erosion (n = 4). There were no recurrences of obstructive symptoms during the follow-up period (mean of 33.3 months). Limitations: This was not a randomized, comparison study, and the number of patients was relatively small. Conclusion: The technique described promotes the relief of GPOS with low overall morbidity and avoids abdominal reoperation for ring removal. (Gastrointest Endosc 2010;72:44-9.)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: EUS is being increasingly utilized for the diagnosis of choledocholithiasis and microlithiasis, especially in patients with biliary colic. Simultaneously, there is also a rising interest in the use of EUS for therapeutic interventions. Objectives: Our goal was to assess the effectiveness of EUS-directed common bile duct (CBD) stone removal to compare its safety and effectiveness with ERCP-directed intervention. Design: interim results of a prospective, randomized, single-center blinded clinical trial. Setting: A single tertiary care referral center. Patients: Fifty-two patients with uncomplicated CBD stones were prospectively randomized to CBD cannulation and stone removal under EUS or ERCP guidance. Main Outcome Measurements and Interventions: Primary outcome measure was the rate of successful cannulation of the CBD. Secondary Outcome measures included Successful removal of stones and overall complication rates. Results: CBD cannulation followed by stone extraction was successful in 23 of 26 patients (88.5%) in the EUS group (1) versus 25 of 26 patients (96.2%) in the ERCP group (11) (95% CI, -27.65%, 9.88%). Overall, there were 3 complications in the EUS group and 4 complications in the ERCP group. Limitation: The current study is an interim report from a single center report and performed by a single operator. Conclusions: Our preliminary analysis indicates that Outcomes following EUS-guided CBD stone retrieval are equivalent to those following ERCP EUS-related adverse events are similar to those following ERCP. ERCP and EUS-guided stone retrieval appears to be equally effective for therapeutic interventions of the bile duct. Additional studies are required to validate these preliminary results and to determine predictors of success of EUS-guided stone removal. (Gastrointest Endosc 2009;69:238-43.)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Anterior ethmoidal artery (AEA) ligation may be necessary in cases of severe epistaxis not controllable with traditional therapy. Endoscopic endonasal ligation of the AEA is not used frequently; there are few studies in the literature for standardization of the endoscopic technique for this vessel. Aim: To demonstrate the feasibility of periorbital AEA ligation in a transethmoidal endoscopic approach. Methods: A prospective study where 50 nasal cavities were dissected. After anterior ethmoidectomy and partial removal of lamina papyracea, the periorbital area was carefully dissected along a subperiosteal plane to identify the AEA. The vessel was exposed within the orbit and dissected. Results: Data on technical difficulties, complications, the learning curve and anatomical variations were gathered. Conclusion: An endonasal endoscopic approach to the AEA within the orbit was shown to be feasible. Identifying the artery is not difficult, and this technique avoids external incisions. This approach appears to be an excellent alternative for approaching the AEA. Further clinical studies are needed to demonstarte the benefits of this technique.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To develop a new endoscopic approach to the correction of a myelomeningocele-like defect in fetal sheep. Methods: The fetuses of 9 pregnant ewes, with an average gestational age of 115 days, were subjected to a 3.0 x 2.0 cm removal of the skin over the lumbar spine, performed through hysterotomy. The uterus was closed, and three 5-mm endoscopic cannulas, without valve mechanisms, were inserted. In the pilot phase (2 animals), we initially worked exclusively in the amniotic fluid space. In the study phase, we partially withdrew the fetus from the amniotic fluid to completely expose its back. By simply allowing air to enter the amniotic cavity (without gas injection), a working space was created using a uterine lift device. The skin around the defect was dissected, and a biosynthetic cellulose material was applied to cover the area. A continuous suture of the skin was performed to completely hide the material. Results: The combined air/fluid space allowed the skin to be successfully closed in 6 out of 7 cases in the study phase. All fetuses were alive at the end of the procedures. Time to complete the endoscopic part of the procedure fell from 3 to 1 h by the end of this series. Premature birth occurred in 2 of the 4 cases allowed to continue with the pregnancy. Conclusion: A new gasless fetoscopic surgery technique was developed as an alternative to current techniques used for fetal endoscopic surgery. Copyright (C) 2008 S. Karger AG, Basel.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: The pterygopalatine fossa (PPF) is a narrow space located between the posterior wall of the antrum and the pterygoid plates. Surgical access to the PPF is difficult because of its protected position and its complex neurovascular anatomy. Endonasal approaches using rod lens endoscopes, however, provide better visualization of this area and are associated with less morbidity than external approaches. Our aim was to develop a simple anatomical model using cadaveric specimens injected with intravascular colored silicone to demonstrate the endoscopic anatomy of the PPF. This model could be used for surgical instruction of the transpterygoid approach. Methods: We dissected six PPF in three cadaveric specimens prepared with intravascular injection of colored material using two different injection techniques. An endoscopic endonasal approach, including a wide nasoantral window and removal of the posterior antrum wall, provided access to the PPF. Results: We produced our best anatomical model injecting colored silicone via the common carotid artery. We found that, using an endoscopic approach, a retrograde dissection of the sphenopalatine artery helped to identify the internal maxillary artery (IMA) and its branches. Neural structures were identified deeper to the vascular elements. Notable anatomical landmarks for the endoscopic surgeon are the vidian nerve and its canal that leads to the petrous portion of the internal carotid artery (ICA), and the foramen rotundum, and V2 that leads to Meckel`s cave in the middle cranial fossa. These two nerves, vidian and V2, are separated by a pyramidal shaped bone and its apex marks the ICA. Conclusion: Our anatomical model provides the means to learn the endoscopic anatomy of the PPF and may be used for the simulation of surgical techniques. An endoscopic endonasal approach provides adequate exposure to all anatomical structures within the PPF. These structures may be used as landmarks to identify and control deeper neurovascular structures. The significance is that an anatomical model facilitates learning the surgical anatomy and the acquisition of surgical skills. A dissection superficial to the vascular structures preserves the neural elements. These nerves and their bony foramina, such as the vidian nerve and V2, are critical anatomical landmarks to identify and control the ICA at the skull base.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study analyzed the effects of the unilateral removal and dissection of the masseter muscle on the facial growth of young rats. A total of 30 one-month-old Wistar rats were used. Unilateral complete removal of the masseter muscle was performed in the removal group, and detachment followed by repositioning of the masseter muscle was performed in the dissection group, while only surgical access was performed in the sham-operated group. The animals were sacrificed at three months of age. Axial radiographic projections of the skulls and lateral projections of the hemimandibles were taken. Cephalometric evaluations were made and the values obtained were submitted to statistical analyses. In the removal group, there were contour alterations of the angular process, and a significant homolateral difference in the length of the maxilla and a significant bilateral difference in the height of the mandibular body and the length of the mandible were observed. Comparison among groups revealed significance only in the removal group. It was concluded that the experimental removal of the masseter muscle during the growing period in rats induced atrophic changes in the angular process, as well as asymmetry of the maxilla and shortening of the whole mandible.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: Causes may be found in most cases of acute pancreatitis, however no etiology is found by clinical, biological and imaging investigations in 30% of these cases. Our objective was to evaluate results from endoscopic ultrasonography (EUS) for diagnosis of gallbladder microlithiasis in patients with unexplained (idiopathic) acute pancreatitis. METHODS: Thirty-six consecutive non-alcoholic patients with diagnoses of acute pancreatitis were studied over a five-year period. None of them showed signs of gallstones on transabdominal ultrasound or tomography. We performed EUS within one week of diagnosing acute pancreatitis. Diagnosis of gallbladder microlithiasis on EUS was based upon findings of hyperechoic signals of 0.5-3.0 mm, with or without acoustic shadowing. All patients (36 cases) underwent cholecystectomy, in accordance with indication from the attending physician or based upon EUS diagnosis. RESULTS: Twenty-seven patients (75%) had microlithiasis confirmed by histology and nine did not (25%). EUS findings were positive in twenty-five. Two patients had acute cholecystitis diagnosed at EUS that was confirmed by surgical and histological findings. In two patients, EUS showed cholesterolosis and pathological analysis disclosed stones not detected by EUS. EUS diagnosed microlithiasis in four cases not confirmed by surgical treatment. In our study, sensitivity, specificity and positive and negative predictive values to identify gallbladder microlithiasis (with 95% confidence interval) were 92.6% (74.2-98.7%), 55.6% (22.7-84.7%), 86.2% (67.4-95.5%) and 71.4% (30.3-94.9%), respectively. Overall EUS accuracy was 83.2%. CONCLUSIONS: EUS is a very reliable procedure to diagnose gallbladder microlithiasis and should be used for the management of patients with unexplained acute pancreatitis. This procedure should be part of advanced endoscopic evaluation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to verify whether screw abutment lubrication can generate higher preload values compared to non-lubricated screws, a titanium abutment was screwed onto an implant analog and scanned with the Procera System to generate 20 zirconia abutments. MKIII Brånemark implants were clamped to a precision torque device, and the abutments were distributed in dry and wet groups with 10 specimens each. In the wet groups, the inner threads of the implants were filled with artificial saliva. All abutments were fastened with a Torqtite screw under 32 Ncm. Ten detorque measurements were performed per group pushing the reverse button of the Torque controller soon after screw tightening with values registered. The mean detorque values were calculated and compared by a Student's t test (?=0.05). The wet condition presented significantly higher mean detorque than the dry condition (31.5 ± 1.2 versus 27.5 ± 1.5 Ncm, respectively; p=0.0000024). In conclusion, there was always a loss in the initial torque values when the removal torque was measured under both conditions. The wet condition presented higher mean torque than the dry condition. Better preload values were established in the wet group, suggesting that the abutment screw must be lubricated in saliva to avoid further loosening.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Temperature-dependent electrical resistance in quasi-one-dimensional Li(0.9)Mo(6)O(17) is described by two Luttinger liquid anomalous exponents alpha, each associated with a distinct one dimensional band. The band with alpha < 1 is argued to crossover to a higher dimension below the temperature T(M'), leading to superconductivity. Disorder and magnetic fields are shown to induce the Bose metal behavior in this bulk compound.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Lignin and hemicelluloses are the major components limiting enzyme infiltration into cell walls. Determination of the topochemical distribution of lignin and aromatics in sugar cane might provide important data on the recalcitrance of specific cells. We used cellular ultraviolet (UV) microspectrophotometry (UMSP) to topochemically detect lignin and hydroxycinnamic acids in individual fiber, vessel and parenchyma cell walls of untreated and chlorite-treated sugar cane. Internodes, presenting typical vascular bundles and sucrose-storing parenchyma cells, were divided into rind and pith fractions. Results: Vascular bundles were more abundant in the rind, whereas parenchyma cells predominated in the pith region. UV measurements of untreated fiber cell walls gave absorbance spectra typical of grass lignin, with a band at 278 nm and a pronounced shoulder at 315 nm, assigned to the presence of hydroxycinnamic acids linked to lignin and/or to arabino-methylglucurono-xylans. The cell walls of vessels had the highest level of lignification, followed by those of fibers and parenchyma. Pith parenchyma cell walls were characterized by very low absorbance values at 278 nm; however, a distinct peak at 315 nm indicated that pith parenchyma cells are not extensively lignified, but contain significant amounts of hydroxycinnamic acids. Cellular UV image profiles scanned with an absorbance intensity maximum of 278 nm identified the pattern of lignin distribution in the individual cell walls, with the highest concentration occurring in the middle lamella and cell corners. Chlorite treatment caused a rapid removal of hydroxycinnamic acids from parenchyma cell walls, whereas the thicker fiber cell walls were delignified only after a long treatment duration (4 hours). Untreated pith samples were promptly hydrolyzed by cellulases, reaching 63% of cellulose conversion after 72 hours of hydrolysis, whereas untreated rind samples achieved only 20% hydrolyzation. Conclusion: The low recalcitrance of pith cells correlated with the low UV-absorbance values seen in parenchyma cells. Chlorite treatment of pith cells did not enhance cellulose conversion. By contrast, application of the same treatment to rind cells led to significant removal of hydroxycinnamic acids and lignin, resulting in marked enhancement of cellulose conversion by cellulases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ultraprecision diamond turning was used to evaluate the surface integrity of a carbon nanotube (CNT) composite as a function of the cutting conditions and the percentage of CNT in the epoxy matrix. The effects of cutting conditions on the chip morphology and surface roughness were analysed. The results showed that an increase in the percentage of CNT may influence the mechanism of material removal and consequently improve the quality of the machined surface. When smaller quantities of CNT (0.02 and 0.07 wt %) are present in the matrix, microcracks form within the cutting grooves (perpendicular to the cutting direction). This indicates that the amount of CNT on the epoxy matrix may have a direct influence on the mechanical properties of these materials. Chips removed from the CNT composite samples were analysed by scanning electron microscopy in order to correlate the material removal mechanism and the surface generation process. The area average surface roughness Sa was influenced by the material removal mechanism (Sa ranging from 0.28 to 1.1 mu m).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and Purpose: Fibrotic or neoplastic obstruction of the terminal ureter and ureterovesical junction can preclude internal drainage with a Double-J catheter. Some minimally invasive alternatives are described in the literature to avoid a percutaneous nephrostomy. We present a pure endourologic technique. Patients and Methods: In six patients with an obstructed upper urinary tract, after the introduction of iodine contrast, the ureter was punctured with a needle to introduce a guidewire in the urinary tract under cystoscopic and fluoroscopic control. The alternative path between the bladder and ureter was then dilated up 10F to facilitate the Double-J catheter introduction. Results: All six patients had their obstructed urinary tract drained with a Double-J catheter inserted above the level of obstruction. No complication was verified. Conclusion: Internal urinary tract drainage with a Double-J catheter was accomplished using endourologic principles in six patients, avoiding a percutaneous nephrostomy or other more invasive procedures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Over two-thirds of renal masses noted incidentally on abdominal CT scans performed for nonurological indications are most likely renal cell carcinoma (RCC). The prognosis in these instances is often quite favorable, as early diagnosis offers the best hope of a complete cure. We report the identification of a RCC incidentally at endoscopic ultrasound (EUS) while an earlier CT scan of abdomen was negative. The mass was biopsied resulting in a histological confirmation of RCC and successful surgical resection.