2 resultados para Duloxetine

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Antidepressants increase melatonin levels, but it is still unclear whether this effect is related to the improvement of depressive symptoms or to unrelated pharmacological action of antidepressants. To answer this question, the effect of antidepressants on 6-sulphatoxymelatonin (aMT6s), the main melatonin urinary metabolite, was examined in drug-free depressed patients - most of them antidepressant-naive. aMT6s was evaluated in 34 depressed patients, before and after 8 weeks of placebo (n = 12) or antidepressant (n = 22; fluoxetine, duloxetine or Hypericum perforatum). Both groups showed an improvement of depressive symptoms after treatment compared to baseline (Hamilton Depression scores): 17.0 +/- 1.4 vs. 9.0 +/- 2.8, P = 0.007 for placebo, and 18.6 +/- 1.1 vs. 11.8 +/- 1.6, P < 0.001 for antidepressants). After treatment, aMT6s levels increased after antidepressants (P < 0.01), but not after placebo (P > 0.05). As depressive symptoms improved both in patients taking antidepressant and in those taking placebo, but an effect of antidepressants could only be seen in those taking antidepressants, we suggest that melatonin changes after antidepressants are more likely due to a pharmacological action of these drugs on melatonin secretion.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A new polymeric coating consisting of a dual-phase, polydimethylsiloxane (PDMS) and polypyrrole (PPY) was developed for the stir bar sorptive extraction (SBSE) of antidepressants (mirtazapine, citalopram, paroxetine, duloxetine, fluoxetine and sertraline) from plasma samples, followed by liquid chromatography analysis (SBSE/LC-UV). The extractions were based on both adsorption (PPY) and sorption (PDMS) mechanisms. SBSE variables, such as extraction time, temperature, pH of the matrix, and desorption time were optimized, in order to achieve suitable analytical sensitivity in a short time period. The PDMS/PPY coated stir bar showed high extraction efficiency (sensitivity and selectivity) toward the target analytes. The quantification limits (LOQ) of the SBSE/LC-UV method ranged from 20 ng mL(-1) to 50 ng mL(-1), and the linear range was from LOQ to 500 ng mL(-1), with a determination coefficient higher than 0.99. The inter-day precision of the SBSE/LC-UV method presented a variation coefficient lower than 15%. The efficiency of the SBSE/LC-UV method was proved by analysis of plasma samples from elderly depressed patients. (C) 2008 Elsevier B.V. All rights reserved.