3 resultados para Curricular department
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)
Resumo:
Background: Patients with chronic obstructive pulmonary disease (COPD) can have recurrent disease exacerbations triggered by several factors, including air pollution. Visits to the emergency respiratory department can be a direct result of short-term exposure to air pollution. The aim of this study was to investigate the relationship between the daily number of COPD emergency department visits and the daily environmental air concentrations of PM(10), SO(2), NO(2), CO and O(3) in the City of Sao Paulo, Brazil. Methods: The sample data were collected between 2001 and 2003 and are categorised by gender and age. Generalised linear Poisson regression models were adopted to control for both short-and long-term seasonal changes as well as for temperature and relative humidity. The non-linear dependencies were controlled using a natural cubic spline function. Third-degree polynomial distributed lag models were adopted to estimate both lag structures and the cumulative effects of air pollutants. Results: PM(10) and SO(2) readings showed both acute and lagged effects on COPD emergency department visits. Interquartile range increases in their concentration (28.3 mg/m(3) and 7.8 mg/m(3), respectively) were associated with a cumulative 6-day increase of 19% and 16% in COPD admissions, respectively. An effect on women was observed at lag 0, and among the elderly the lag period was noted to be longer. Increases in CO concentration showed impacts in the female and elderly groups. NO(2) and O(3) presented mild effects on the elderly and in women, respectively. Conclusion: These results indicate that air pollution affects health in a gender-and age-specific manner and should be considered a relevant risk factor that exacerbates COPD in urban environments.
Resumo:
The treatment of sensorineural hearing loss is based on hearing aids, also known as individual sound amplification devices. The hearing aids purchased by the Brazilian Government, aiming at fulfilling public policies, are based on dedicated components, which bring about benefits, but also render them expensive and may impair repair services after manufacture`s warranty expires. Aim: to design digital behind-the-ear hearing aids built from standardized components coming from the very supply chain of these manufacturers. Study design: experimental. Materials and Methods: to identify the supply chain of these manufacturers, request samples and set up hearing aids in the laboratory. Results: The developed hearing aids did not show lesser electroacoustic characteristics when compared to those acquired by the Government, also being tested by the same reference international technical standard. Conclusion: It is possible to develop digital behind-the-ear hearing aids based on off-the-shelf components from hearing aid manufacturers` supply chain. Their advantages include low operational costs - for acquisition (with clear advantages for the Government) and service (advantage for the patient).
Resumo:
Background Occupational risk due to airborne disease challenges healthcare institutions. Environmental measures are effective but their cost-effectiveness is still debatable and most of the capacity planning is based on occupational rates. Better indices to plan and evaluate capacity are needed. Goal To evaluate the impact of installing an exclusively dedicated respiratory isolation room (EDRIR) in a tertiary emergency department (ED) determined by a time-to-reach-facility method. Methods A group of patients in need of respiratory isolation were first identified-group I (2004; 29 patients; 44.1 +/- 3.4 years) and the occupational rate and time intervals (arrival to diagnosis, diagnosis to respiratory isolation indication and indication to effective isolation) were determined and it was estimated that adding an EDRIR would have a significant impact over the time to isolation. After implementing the EDRIR, a second group of patients was gathered in the same period of the year-group II (2007; 50 patients; 43.4 +/- 1.8 years) and demographic and functional parameters were recorded to evaluate time to isolation. Cox proportional hazard models adjusted for age, gender and inhospital respiratory isolation room availability were obtained. Results Implementing an EDRIR decreased the time from arrival to indication of respiratory isolation (27.5 +/- 9.3 X 3.7 +/- 2.0; p = 0.0180) and from indication to effective respiratory isolation (13.3 +/- 3.0 X 2.94 +/- 1.06; p = 0.003) but not the respiratory isolation duration and total hospital stay. The impact on crude isolation rates was very significant (8.9 X 75.4/100.000 patients; p < 0.001). The HR for effective respiratory isolation was 26.8 (95% CI 7.42 to 96.9) p < 0.001 greater for 2007. Conclusion Implementing an EDRIR in a tertiary ED significantly reduced the time to respiratory isolation.