10 resultados para Compliance aid

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: The aim of this study was to assess the infuence of efforts applied to modify the patients' behavior towards periodontal maintenance. MATERIAL AND METHODS: Patients were classifed into three groups: Complete Compliance (participation in all visits), Irregular Compliance (irregular participation, one or more missing appointments), and Noncompliance (abandoned or never returned to the program). Complete compliers received usual procedures of the maintenance visit. The irregular compliers and non-compliers received usual procedures and strategies such as reminding next visit, informing patients on both periodontal disease and importance of maintenance, motivating the patient who showed an improvement in compliance. Thus, 137 patients were observed for 12 months. RESULTS: The degree of compliance has increased signifcantly during this period (p=0.001). No association was detected between age or gender and compliance degree. CONCLUSIONS: The results have shown that the intervention applied had a favorable infuence on the patients' compliance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The Brazilian consensus recommends a short-term treatment course with clarithromycin, amoxicillin and proton-pump inhibitor for the eradication of Helicobacter pylori ( H. pylori). This treatment course has good efficacy, but cannot be afforded by a large part of the population. Azithromycin, amoxicillin and omeprazole are subsidized, for several aims, by the Brazilian federal government. Therefore, a short-term treatment course that uses these drugs is a low-cost one, but its efficacy regarding the bacterium eradication is yet to be demonstrated. The study's purpose was to verify the efficacy of H. pylori eradication in infected patients who presented peptic ulcer disease, using the association of azithromycin, amoxicillin and omeprazole. Methods: Sixty patients with peptic ulcer diagnosed by upper digestive endoscopy and H. pylori infection documented by rapid urease test, histological analysis and urea breath test were treated for six days with a combination of azithromycin 500 mg and omeprazole 20 mg, in a single daily dose, associated with amoxicillin 500 mg 3 times a day. The eradication control was carried out 12 weeks after the treatment by means of the same diagnostic tests. The eradication rates were calculated with 95% confidence interval. Results: The eradication rate was 38% per intention to treat and 41% per protocol. Few adverse effects were observed and treatment compliance was high. Conclusion: Despite its low cost and high compliance, the low eradication rate does not allow the recommendation of the triple therapy with azithromycin as an adequate treatment for H. pylori infection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Soci UPR, Fernandes T, Hashimoto NY, Mota GF, Amadeu MA, Rosa KT, Irigoyen MC, Phillips MI, Oliveira EM. MicroRNAs 29 are involved in the improvement of ventricular compliance promoted by aerobic exercise training in rats. Physiol Genomics 43: 665-673, 2011. First published March 29, 2011; doi:10.1152/physiolgenomics.00145.2010.-MiRNAs regulate cardiac development, hypertrophy, and angiogenesis, but their role in cardiac hypertrophy (CH) induced by aerobic training has not previously been studied. Aerobic training promotes physiological CH preserving cardiac function. This study assessed involvement of miRNAs-29 in CH of trained rats. Female Wistar rats (n = 7/group) were randomized into three groups: sedentary (S), training 1 (T1), training 2 (T2). T1: swimming sessions of 60 min/5 days/wk/10 wk. T2: similar to T1 until 8th wk. On the 9th wk rats swam 2x/day, and on the 10th wk 3x/day. MiRNAs analysis was performed by miRNA microarray and confirmed by real-time PCR. We assessed: markers of training, CH by ratio of left ventricle (LV) weight/body wt and cardiomyocytes diameter, pathological markers of CH (ANF, skeletal alpha-actin, alpha/beta-MHC), collagen I and III (COLIAI and COLIIIAI) by real-time PCR, protein collagen by hydroxyproline (OH-proline) concentration, CF and CH by echocardiography. Training improved aerobic capacity and induced CH. MiRNAs-1, 133a, and 133b were downregulated as observed in pathological CH, however, without pathological markers. MiRNA-29c expression increased in T1 (52%) and T2 (123%), correlated with a decrease in COLIAI and COLIIIAI expression in T1 (27%, 38%) and T2 (33%, 48%), respectively. MiRNA-29c was inversely correlated to OH-proline concentration (r = 0.61, P = 0.05). The E/A ratio increased in T2, indicating improved LV compliance. Thus, these results show that aerobic training increase miR-29 expression and decreased collagen gene expression and concentration in the heart, which is relevant to the improved LV compliance and beneficial cardiac effects, associated with aerobic high performance training.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims: To report the conclusion of the Think Thank 8 on Compliance Discussions during the second ICI-RS meeting in 2010. Methods: During a 3-day meeting a group of specialists discussed bladder compliance, what it represents, how it can be measured and if it is clinically relevant. Results: Bladder compliance is the result of a mathematical calculation of the volume required for a unit rise of pressure measured during a cystometric filling. It gives an indication on how the different mechanisms in the bladder wall react on stretching. There is a need of standardization of measurement and suggestions for this are given in the text. Pitfalls are described and how to avoid them. There is a wide range of compliance values in healthy volunteers and groups of patients. Poor compliance needs to be defined better as it can have significant clinical consequences. Prevention and treatment are discussed. Conclusion: If compliance is correctly measured and interpreted, it has importance in urodynamic testing and gives information relevant for clinical management. Neurourol. Urodynam. 30:714-722, 2011. (C) 2011 Wiley-Liss, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

(ECHOCARDIOGRAPHY, Volume 26, September 2009).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The treatment of sensorineural hearing loss is based on hearing aids, also known as individual sound amplification devices. The hearing aids purchased by the Brazilian Government, aiming at fulfilling public policies, are based on dedicated components, which bring about benefits, but also render them expensive and may impair repair services after manufacture`s warranty expires. Aim: to design digital behind-the-ear hearing aids built from standardized components coming from the very supply chain of these manufacturers. Study design: experimental. Materials and Methods: to identify the supply chain of these manufacturers, request samples and set up hearing aids in the laboratory. Results: The developed hearing aids did not show lesser electroacoustic characteristics when compared to those acquired by the Government, also being tested by the same reference international technical standard. Conclusion: It is possible to develop digital behind-the-ear hearing aids based on off-the-shelf components from hearing aid manufacturers` supply chain. Their advantages include low operational costs - for acquisition (with clear advantages for the Government) and service (advantage for the patient).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim Stapled haemorrhoidopexy may damage the anorectal musculature and its sensorimotor function. Most studies have not used a barostat for the measurement of compliance. This study aimed to investigate the effect of stapled haemorrhoidopexy on rectal compliance and sensitivity. Method After Ethical Committee approval, we studied 10 male patients (mean age 33.8 years) with third- or fourth-degree haemorrhoids. Rectal compliance and sensitivity were measured with a 600-ml bag and an electronic barostat. Volunteers were submitted to two consecutive rectal distension protocols, including continuous distension at 2, 4 and 6 months after stapled haemorrhoidopexy. Intraluminal volume and pressure were recorded, including the first rectal sensation, desire to defecate and onset of rectal pain. Another group of 10 male control patients (mean age 24.9 years) with pilonidal sinus and no haemorrhoids was also included in the study. Results Two months after stapled haemorrhoidopexy, rectal compliance decreased (7.1 +/- 0.2 vs 5.3 +/- 0.1, 6.4 +/- 0.1 vs 5.1 +/- 0.1 and 5.6 +/- 0.2 vs 4.7 +/- 0.1 ml/mmHg for first rectal sensation, desire to defecate and rectal pain, respectively; P < 0.05). The sensitivity threshold volume did not change for the first sensation but decreased significantly for the desier to defecate and pain (p < 0.05) (116.8 +/- 13.8 vs 148.4 +/- 14.61, 251.1 +/- 8.9 vs 185.8 +/- 8.6 and 293.3 +/- 16.6 vs 221.2 +/- 6.0 ml for first rectal sensation, desire to defecate and rectal pain, respectively). Four and 6 months after surgery, rectal compliance and sensitivity returned to levels similar to those in the basal period. Muscle tissue was found in only three of the 10 resected doughnuts. Controls remained without any change in rectal compliance and sensitivity. Conclusion Stapled haemorrhoidopexy transiently decreases rectal compliance and sensitivity threshold in young male patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Swallowed prostheses have been described in the literature, and in some cases, the diagnosis can be challenging, especially if the partial or complete denture is metal-free. This article presents a case of a swallowed partial denture and points to the importance of early diagnosis. A man was admitted to the emergency room complaining of progressive breathing difficulty while presenting with an extra volume in his neck. After inconclusive image examinations, endoscopy under sedation was used to identify and retrieve the foreign object, which was a metal-free acrylic partial denture. Early diagnosis and the correct treatment can avoid serious sequelae, such as edematous reactions, mucosal infection, and necrosis. Patients should be scheduled for regular recall visits for evaluation of prosthesis fit and retention, condition of the abutments, and nocturnal wear. Int J Prosthodont 2010;23:339-341.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives. Evaluate the effect of testing system compliance on polymerization stress and stress distribution of composites. Methods. Composites tested were Filtek Z250 (FZ), Herculite (HL), Tetric Ceram (TC), Helio Fill-AP (HF) and Heliomolar (HM). Stress was determined in 1-mm thick specimens, inserted between two rods of either poly(methyl methacrylate), PMMA, or glass. Experimental nominal stress (sigma(exp)) was calculated by dividing the maximum force recorded 5 min after photoactivation by the cross-sectional area of the rod. Composites` elastic modulus (E) was obtained by three-point bending. Data were submitted to one-way ANOVA/Tukey`s test (alpha = 0.05). Stress distribution on longitudinal (sigma(y)) and transverse (sigma(x)) axes of models representing the composites with the highest and lowest E (FZ and HM, respectively) were evaluated by finite element analysis (FEA). Results. sigma(exp) ranged from 5.5 to 8.8 MPa in glass and from 2.6 to 3.4 MPa in PMMA. Composite ranking was not identical in both substrates, since FZ showed or sigma(exp) statistically higher than HM in glass, while in PMMA FZ showed values similar to the other composites. A strong correlation was found between stress reduction (%) from glass to PMMA and composite`s E (r(2) = 0.946). FEA revealed that system compliance was influenced by the composite (FZ led to higher compliance than HM). sigma(x) distribution was similar in both substrates, while cry distribution showed larger areas of compressive stresses in specimens built on PMMA. Significance. sigma(exp) determined in PMMA was 53-68% lower than in glass. Composite ranking varied slightly due to differences in substrates` longitudinal and transverse deformation. (c) 2007 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We assessed the feasibility of obtaining probe microphone measurements of hearing aids at a distance. Face-to-face and remote probe microphone measurements were carried out in 60 hearing aid users (mean age 67 yrs) with uni- or bilateral hearing losses (105 ears tested). The participant and a facilitator were located in a room equipped with a probe microphone system interfaced to a PC. Desktop videoconferencing and application sharing was used to allow an audiologist in another room to instruct the facilitator and control the equipment via the LAN. There were significant correlations between face-to-face and remote real ear unaided response (REUR), aided response (REAR) and insertion gain (REIG) at seven discrete frequencies from 250 to 6000 Hz. Differences between face-to-face and remote responses were within the reported variability for probe microphone measurements themselves. The results show that remote probe microphone measurements are feasible and might improve the quality of public hearing aid services and professional training in Brazil.