43 resultados para Coeficiente de atrito

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The pollutant transference among reservoirs atmosphere-hydrosphere, relevant to the atmospheric chemistry, depends upon scavenging coefficient (Λ) calculus, which depends on the raindrop size distribution as well as on the rainfall systems, both different to each locality. In this work, the Λ calculus will be evaluated to gas SO2 and particulate matter fine and coarse among five sites in Germany and two in Brazil. The results show three possible classifications in function of Λ, comparable to literature, however with a greater range due to the differences of rainfall system sites. This preliminary study supports future researches

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Atualmente, os braquetes autoligáveis têm sido associados a tratamentos mais rápidos e eficazes, o que desperta a curiosidade em compará-los ao sistema convencional. Ao contrário dos braquetes tradicionais, os autoligáveis não necessitam de ligaduras, sejam elásticas ou metálicas. A literatura é farta em concluir que essa característica diminui, ostensivamente, a resistência do atrito durante as mecânicas de deslize. Além disso, existem alegações sobre a dimimuição da necessidade de extrações e de expansão maxilar com o uso desses acessórios. Portanto, o objetivo dessa revisão de literatura foi buscar os mais novos estudos a respeito dos aparelhos autoligáveis atualmente utilizados nos tratamentos ortodônticos, confirmando ou retificando as especulações vigentes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Este estudo caracteriza-se epidemiológico-descritivo com objetivo de descrever a evolução temporal dos casos de dengue em Ribeirão Preto, São Paulo, no período de 1994 a 2003, segundo mês de ocorrência e sexo. Os dados foram obtidos junto às fichas de notificação compulsória fornecidas pela Vigilância Epidemiológica da Secretaria Municipal de Saúde do município. Foram obtidos os coeficientes de incidência por 100.000 habitantes, segundo estimativas populacionais do Instituto Brasileiro de Geografia e Estatística. O município viveu uma epidemia de dengue no ano de 2001, quando o coeficiente de incidência chegou a 619,65 casos/100.000 habitantes, sendo que dentre os 5.553 casos encontrados no período estudado, 0,07% ocorreram no ano de 1994, 3,68% em 1995, 4,52% em 1996, 2,40% em 1997, 1,82% em 1998, 5,73% em 1999, 3,75% em 2000, 57,37% em 2001, 6,25% em 2002 e, 14,39% em 2003 . Os meses do ano de maior ocorrência da doença foram de janeiro a maio. Em relação à variável sexo, a proporção entre o número de casos foi de aproximadamente 1:1, mostrando pequenas flutuações de casos de dengue entre homens e mulheres, para todo período estudado. Os resultados apontam a necessidade do desenvolvimento de estudos sobre a temática e reforçam o papel das instituições de ensino na questão da dengue no nosso país.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Este trabalho avaliou o material de higiene bucal usado em escolas para estabelecer um protocolo às ações de higiene bucal coletiva. O estudo foi dividido em duas etapas: 1ª- 20 responsáveis pelos procedimentos coletivos com escolares de Bauru e São José dos Campos - SP responderam a dois questionários sobre o uso de cinco kits de higiene bucal coletiva. A análise estatística foi realizada através do teste Wilcoxon (p < 0,05); 2ª - 178 escolares de 4 a 8 anos de Bauru e Bariri-SP dispensaram na escova uma quantidade de creme dental e dentifrício líquido para a prática da escovação, a qual foi pesada através de uma balança portátil. A análise estatística foi obtida através do coeficiente de correlação de Pearson e a análise de covariância (p< 0,05). O kit 5 obteve graus de satisfação e muita satisfação quando comparado aos kits 1 a 4. A quantidade de creme dental dispensada pelos escolares foi em média 0,41g (Bauru) e 0,48g (Bariri). Não houve diferença estatística entre os escolares de Bauru e Bariri em relação ao dentifrício líquido (média de 0,15g). O dentifrício líquido, através da "técnica da gota", foi considerado prático, dispensando uma pequena quantidade padronizada. O kit 5 demonstrou ser uma boa alternativa ao estabelecimento de um protocolo de ações em saúde bucal coletiva no SUS.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVOS: avaliar a expressão de erbB-2 e dos receptores hormonais para estrógeno e progesterona (RE/RP) nas regiões de transição entre as frações in situ e invasoras de neoplasias ductais da mama (CDIS e CDI, respectivamente). MÉTODOS: oitenta e cinco casos de neoplasias mamárias, contendo regiões contíguas de CDIS e CDI, foram selecionados. Espécimes histológicos das áreas de CDIS e de CDI foram obtidos através da técnica de tissue microarray (TMA). As expressões da erbB-2 e dos RE/RP foram avaliadas por meio de imunoistoquímica convencional. A comparação da expressão da erbB-2 e dos RE/RP nas frações in situ e invasoras da mama foi realizada com emprego do teste de McNemar. Os intervalos de confiança foram determinados em 5% (p=0,05). Foram calculados coeficientes de correlação intraclasse (ICC) para avaliar a concordância na tabulação cruzada da expressão de erbB-2 e RE/RP nas frações de CDIS e CDI. RESULTADOS: a expressão da erbB-2 não diferiu entre as áreas de CDIS e CDI (p=0,38). Comparando caso a caso suas áreas de CDIS e CDI, houve boa concordância na expressão da erbB-2 (coeficiente de correlação intraclasse, ICC=0,64), dos RP (ICC = 0,71) e dos RE (ICC = 0,64). Considerando apenas tumores cujo componente in situ apresentasse áreas de necrose (comedo), o ICC para erbB-2 foi de 0,4, comparado a 0,6 no conjunto completo de casos. Os ICC não diferiram substancialmente daqueles obtidos com o conjunto completo de espécimes em relação aos RE/RP: para RE, ICC=0,7 (versus 0,7 no conjunto completo), e para RP, ICC=0,7 (versus 0,6 no conjunto completo). CONCLUSÕES: nossos achados sugerem que as expressões de erbB-2 e RE/RP não diferem nos componentes contíguos in situ e invasivo em tumores ductais da mama.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: avaliar a influência da idade, do sexo, da relação oclusal sagital, do Padrão Facial e de 8 medidas do perfil facial sobre a estética do perfil. MÉTODOS: foram utilizadas tabelas de contingência, o Teste Qui-quadrado e o coeficiente de Cramér para avaliar a possível associação entre a nota dada por 32 avaliadores (14 ortodontistas, 12 leigos e 6 artistas) para a estética do perfil de 100 brasileiros - adultos, leucodermas, portadores de selamento labial passivo - e a idade, o sexo, a relação oclusal sagital, o Padrão Facial e as variáveis da análise facial numérica do perfil. RESULTADOS: não foi observada associação entre a idade, o sexo e a relação oclusal sagital e a estética do perfil facial. A associação foi observada entre a nota recebida para a estética do perfil e o Padrão Facial, o ângulo de convexidade facial e o ângulo do terço inferior da face. CONCLUSÃO: o Padrão Facial, definido na avaliação do perfil pela convexidade do perfil facial, e a projeção anterior do mento foram, entre os fatores avaliados, os determinantes para a estética do perfil facial.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Este estudo teve como objetivo realizar a adaptação cultural do The Environmental Stressor Questionnaire - (ESQ) para a língua portuguesa do Brasil e verificar sua confiabilidade e validade. Foram empregadas as etapas metodológicas recomendadas pela literatura para adaptação cultural. A versão brasileira do ESQ foi aplicada a 106 pacientes de Unidade de Terapia Intensiva (UTI) de dois hospitais, público e privado, do interior do Estado de São Paulo. A confiabilidade foi avaliada quanto à consistência interna e estabilidade (teste e reteste); a validade convergente foi verificada por meio da correlação entre o ESQ e questão genérica sobre estresse em UTI. A confiabilidade foi satisfatória com Alfa de Crombach=0,94 e Coeficiente de Correlação Intraclasse=0,861 (IC95% 0,723; 0,933). Constatou-se correlação entre o escore total do ESQ e a questão genérica sobre estresse (r=0,70), confirmando a validade convergente. A versão brasileira do ESQ mostrou-se uma ferramenta confiável e válida para avaliação de estressores em UTI.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVOS: avaliar e mensurar a sutura palatina mediana por meio de radiografias oclusais totais de maxila digitalizadas, antes e depois da sua disjunção. MÉTODOS: a amostra constou de 17 pacientes, com idades entre 7 e 22 anos. Radiografias oclusais totais da maxila foram executadas antes e depois da abertura da sutura palatina mediana, e digitalizadas em scanner HP Scanjet 6110 C com adaptador de transparências HPC 6261 6100 C, utilizando-se o programa Deskscan II. Para a avaliação e medição, foi utilizado o programa Radioimp® (Radiomemory, MG/Brasil). Na análise estatística, foram utilizados a média, o desvio-padrão, o coeficiente de variação e os testes "t" e ANOVA. CONCLUSÕES: após os resultados, foi possível concluir que (1) na região dos incisivos, houve uma abertura palatina mediana estatisticamente significativa; (2) houve abertura de diastema entre os incisivos centrais superiores em torno de 69,37% dos casos; (3) houve uma maior abertura da sutura palatina mediana na região a 10mm a partir da crista para posterior, em comparação com a região a 3mm para posterior do parafuso expansor; (4) na região a 3mm para posterior do parafuso expansor houve uma abertura de 35,97%, e na região a 10mm para posterior da crista uma abertura de 69,37%.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A simple and low cost method to determine volatile contaminants in post-consumer recycled PET flakes was developed and validated by Headspace Dynamic Concentration and Gas Chromatography-Flame Ionization Detection (HDC-GC-FID). The analytical parameters evaluated by using surrogates include: correlation coefficient, detection limit, quantification limit, accuracy, intra-assay precision, and inter-assay precision. In order to compare the efficiency of the proposed method to recognized automated techniques, post-consumer PET packaging samples collected in Brazil were used. GC-MS was used to confirm the identity of the substances identified in the PET packaging. Some of the identified contaminants were estimated in the post-consumer material at concentrations higher than 220 ng.g-1. The findings in this work corroborate data available in the scientific literature pointing out the suitability of the proposed analytical method.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Amyloglucosidase enzyme was produced by Aspergillus niger NRRL 3122 from solid-state fermentation, using deffated rice bran as substrate. The effects of process parameters (pH, temperature) in the equilibrium partition coefficient for the system amyloglucosidase - resin DEAE-cellulose were investigated, aiming at obtaining the optimum conditions for a subsequent purification process. The highest partition coefficients were obtained using 0.025M Tris-HCl buffer, pH 8.0 and 25ºC. The conditions that supplied the highest partition coefficient were specified, the isotherm that better described the amyloglucosidase process of adsorption obtained. It was observed that the adsorption could be well described by Langmuir equation and the values of Qm and Kd estimated at 133.0 U mL-1 and 15.4 U mL-1, respectively. From the adjustment of the kinetic curves using the fourth-order Runge-Kutta algorithm, the adsorption (k1) and desorption (k2) constants were obtained through optimization by the least square procedure, and the values calculated were 2.4x10-3 mL U-1 min-1 for k1 and 0.037 min-1 for k2 .

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This article deals with the scavenging processes modeling of the particulate sulfate and the gas sulfur dioxide, emphasizing the synoptic conditions at different sampling sites in order to verify the domination of the in-cloud or below-cloud scavenging processes in the Metropolitan Area of São Paulo (RMSP). Three sampling sites were chosen: GV (Granja Viana) at RMSP surroundings, IAG-USP and Mackenzie (RMSP center). Basing on synoptic conditions, it was chosen a group of events where the numerical modeling, a simple scavenging model, was used. These synoptic conditions were usually convective cloud storms, which are usual at RMSP. The results show that the in-cloud processes were dominant (80%) for sulfate/sulfur dioxide scavenging processes, with below-cloud process indicating around 20% of the total. Clearly convective events, with total rainfall higher than 20 mm, are better modeled than the stratiform events, with correlation coefficient of 0.92. There is also a clear association with events presenting higher rainfall amount and the ratio between modeled and observed data set with correlation coefficient of 0.63. Additionally, the suburb sampling site, GV, as expected due to the pollution source distance, presents in general smaller amount of rainwater sulfate (modeled and observed) than the center sampling site, Mackenzie, where the characterization event explains partially the rainfall concentration differences.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Este trabalho avalia o desempenho de previsões sazonais do modelo climático regional RegCM3, aninhado ao modelo global CPTEC/COLA. As previsões com o RegCM3 utilizaram 60 km de resolução horizontal num domínio que inclui grande parte da América do Sul. As previsões do RegCM3 e CPTEC/COLA foram avaliadas utilizando as análises de chuva e temperatura do ar do Climate Prediction Center (CPC) e National Centers for Enviromental Prediction (NCEP), respectivamente. Entre maio de 2005 e julho de 2007, 27 previsões sazonais de chuva e temperatura do ar (exceto a temperatura do CPTEC/COLA, que possui 26 previsões) foram avaliadas em três regiões do Brasil: Nordeste (NDE), Sudeste (SDE) e Sul (SUL). As previsões do RegCM3 também foram comparadas com as climatologias das análises. De acordo com os índices estatísticos (bias, coeficiente de correlação, raiz quadrada do erro médio quadrático e coeficiente de eficiência), nas três regiões (NDE, SDE e SUL) a chuva sazonal prevista pelo RegCM3 é mais próxima da observada do que a prevista pelo CPTEC/COLA. Além disto, o RegCM3 também é melhor previsor da chuva sazonal do que da média das observações nas três regiões. Para temperatura, as previsões do RegCM3 são superiores às do CPTEC/COLA nas áreas NDE e SUL, enquanto o CPTEC/COLA é superior no SDE. Finalmente, as previsões de chuva e temperatura do RegCM3 são mais próximas das observações do que a climatologia observada. Estes resultados indicam o potencial de utilização do RegCM3 para previsão sazonal, que futuramente deverá ser explorado através de previsão por conjunto.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: The aim of this study was to translate the Structured Clinical Interview for Mood Spectrum into Brazilian Portuguese, measuring its reliability, validity, and defining scores for bipolar disorders. METHOD: Questionnaire was translated (into Brazilian Portuguese) and back-translated into English. Sample consisted of 47 subjects with bipolar disorder, 47 with major depressive disorder, 18 with schizophrenia and 22 controls. Inter-rater reliability was tested in 20 subjects with bipolar disorder and MDD. Internal consistency was measured using the Kuder Richardson formula. Forward stepwise discriminant analysis was performed. Scores were compared between groups; manic (M), depressive (D) and total (T) threshold scores were calculated through receiver operating characteristic (ROC) curves. RESULTS: Kuder Richardson coefficients were between 0.86 and 0.94. Intraclass correlation coefficient was 0.96 (CI 95 % 0.93-0.97). Subjects with bipolar disorder had higher M and T, and similar D scores, when compared to major depressive disorder (ANOVA, p < 0.001). The sub-domains that best discriminated unipolar and bipolar subjects were manic energy and manic mood. M had the best area under the curve (0.909), and values of M equal to or greater than 30 yielded 91.5% sensitivity and 74.5% specificity. CONCLUSION: Structured Clinical Interview for Mood Spectrum has good reliability and validity. Cut-off of 30 best differentiates subjects with bipolar disorder vs. unipolar depression. A cutoff score of 30 or higher in the mania sub-domain is appropriate to help make a distinction between subjects with bipolar disorder and those with unipolar depression.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A avaliação do coeficiente de variação (CV) como medida da precisão dos experimentos tem sido feita com diversas culturas, espécies animais e forrageiras por meio de trabalhos sugerindo faixas de classificação dos valores, considerando-se a média, o desvio padrão e a distribuição dos valores de CV das diversas variáveis respostas envolvidas nos experimentos. Neste trabalho, objetivouse estudar a distribuição dos valores de CV de experimentos com a cultura do feijão, propondo faixas que orientem os pesquisadores na avaliação de seus estudos com cada variável. Os dados utilizados foram obtidos de revisão em revistas que publicam artigos científicos com a cultura do feijão. Foram consideradas as variáveis: rendimento, número de vagens por planta, número de grãos por vagem, peso de 100 grãos, estande final, altura de plantas e índice de colheita. Foram obtidas faixas de valores de CV para cada variável tomando como base a distribuição normal, utilizando-se também a distribuição dos quantis amostrais e a mediana e o pseudo-sigma, classificando-os como baixo, médio, alto e muito alto. Os cálculos estatísticos para verificação da normalidade dos dados foram implementados por meio de uma função no software estatístico livre R. Os resultados obtidos indicaram que faixas de valores de CV diferiram entre as diversas variáveis apresentando ampla variação justificando a necessidade de utilizar faixa de avaliação específica para cada variável.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A simple and fast capillary zone electrophoresis (CZE) method has been developed and validated for quantification of a non-nucleoside reverse transcriptase inhibitor (NNRTI) nevirapine, in pharmaceuticals. The analysis was optimized using 10 mmol L-1 sodium phosphate buffer pH 2.5, +25 kV applied voltage, hydrodynamic injection 0.5 psi for 5 s and direct UV detection at 200 µm. Diazepam (50.0 µg mL-1) was used as internal standard. Under these conditions, nevirapine was analyzed in approximately less than 2.5 min. The analytical curve presented a coefficient of correlation of 0.9994. Limits of detection and quantification were 1.4 µg mL-1 and 4.3 µg mL-1, respectively. Intra- and inter-day precision expressed as relative standard deviations were 1.4% and 1.3%, respectively and the mean recovery was 100.81%. The active pharmaceutical ingredient was subjected to hydrolysis (acid, basic and neutral) and oxidative stress conditions. No interference of degradation products and tablet excipients were observed. This method showed to be rapid, simple, precise, accurate and economical for determination of nevirapine in pharmaceuticals and it is suitable for routine quality control analysis since CE offers benefits in terms of quicker method development and significantly reduced operating costs.