8 resultados para Clupea harengus, total length

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to develop a fast capillary electrophoresis method for the determination of propranolol in pharmaceutical preparations. In the method development the pH and constituents of the background electrolyte were selected using the effective mobility versus pH curves. Benzylamine was used as the internal standard. The background electrolyte was composed of 60 mmol L(-1) tris(hydroxymethyl)aminomethane and 30 mmol L(-1) 2-hydroxyisobutyric acid,at pH 8.1. Separation was conducted in a fused-silica capillary (32 cm total length and 8.5 cm effective length, 50 mu m I.D.) with a short-end injection configuration and direct UV detection at 214 nm. The run time was only 14 s. Three different strategies were studied in order to develop a fast CE method with low total analysis time for propranolol analysis: low flush time (Lflush) 35 runs/h, without flush (Wflush) 52 runs/h, and Invert (switched polarity) 45 runs/h. Since the three strategies developed are statistically equivalent, Mush was selected due to the higher analytical frequency in comparison with the other methods. A few figures of merit of the proposed method include: good linearity (R(2) > 0.9999); limit of detection of 0.5 mg L(-1): inter-day precision better than 1.03% (n = 9) and recovery in the range of 95.1-104.5%. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The present study is part of an ongoing investigation into the characteristics of Myxozoan parasites of Brazilian freshwater fish and was carried out using morphology, histopathology and electron microscopy analysis. A new Myxosporea species (Henneguya pseudoplatystoma) is described causing an important reduction in gill function in the farmed pintado (a hybrid fish from a cross between Pseudoplatystoma corruscans and Pseudoplatystoma fasciatum), which is a commercially important South American catfish. From a total of 98 pintado juveniles from fish farms in the states of Sao Paulo and Mato Grosso do Sul (Brazil), 36 samples (36.7%) exhibited infection of the gill filaments. infection was intense, with several plasmodia occurring on a same gill filament. The plasmodia were white and measured up to 0.5 mm in length; mature spores were ellipsoidal in the frontal view, measuring 33.2 +/- 1.9 mu m in total length, 10.4 +/- 0.6 mu m in body length, 3.4 +/- 0.4 mu m in width and 22.7 +/- 1.7 mu m in the caudal process. The polar capsules were elongated, measuring 3.3 +/- 0.4 mu m in length and 1.0 +/- 0.1 mu m in width and the polar filaments had six to seven turns. Histopathological analysis revealed the parasite in the connective tissue of the gill filaments and lamella. No inflammatory process was observed, but the development of the plasmodia reduced the area of functional epithelium. Ultrastructural analyses revealed a single plasmodial wall, which was in direct contact with the host cells and had numerous projections in direction of the host cells as well as extensive pinocytotic canals. A thick layer (2-6 mu m) of fibrous material and numerous mitochondria were found in the ectoplasm. Generative cells and the earliest stage of sporogenesis were seen more internally. Advanced spore developmental stages and mature spores were found in the central portion of the plasmodia. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new myxosporean species, Henneguya eirasi n. sp., is described parasitizing the gill filaments of Pseudoplatystoma corruscans and Pseudoplatystoma fasciatum (Siluriformes: Pimelodidae) caught in the Patanal Wetland of the state of Mato Grosso, Brazil. The parasite formed white, elongated plasmodia measuring up to 3 mm. Mature spores were ellipsoidal in the frontal view, measuring 37.1 +/- 1.8 mu m in total length, 12.9 +/- 0.8 mu m in body length, 3.4 +/- 0.3 mu m in width, 3.1 +/- 0.1 mu m in thickness and 24.6 +/- 2.2 mu m in the caudal process. Polar capsules were elongated and equal in size, measuring 5.4 +/- 0.5 mu m in length and 0.7 +/- 0.1 mu m in width. Polar filaments had 12-13 coils. Histopathological analysis revealed that the parasite developed in the sub-epithelial connective tissue of the gill filaments and the plasmodia were surrounded by a capsule of host connective tissue. The plasmodia caused slight compression of the adjacent tissues, but no inflammatory response was observed in the infection site. Ultrastructure analysis revealed a single plasmodial wall connected to the ectoplasmic zone through numerous pinocytotic canals. The plasmodial wall exhibited numerous projections and slightly electron-dense material was found in the ectoplasm next to the plasmodial wall, forming a line just below the wall. Partial sequencing of the 18S rDNA gene of H. eirasi n. sp. obtained from P. fasciatum resulted in a total of 1066 bp and this sequence did not match any of the Myxozoa available in the GenBank. Phylogenetic analysis revealed the Henneguya species clustering into clades following the order and family of the host fishes. H. eirasi n. sp. clustered alone in one clade, which was the basal unit for the clade composed of Henneguya species parasites of siluriform ictalurids. The prevalence of the parasite was 17.1% in both fish species examined. Parasite prevalence was not influenced by season, host sex or host size. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this report, we describe Henneguya arapaima n. sp., a parasite of the gill arch and gall bladder of Arapaima gigas (pirarucu) collected in the Araguaia River, in the municipality of Nova Crixas, Goias State, central Brazil. The plasmodia were white, round or ellipsoidal and measured 200-600 mu m. Parasite development was asynchronous and the mature spores were fusifonn and had smooth wall. The spores measurements were (range, with means +/- S.D. in parentheses): total length-48.4-53.1 mu m (51.6 +/- 3.4 mu m), body length-13.5-15.2 mu m (14.2 +/- 0.8 mu m), body width-5.1-6.1 mu m (5.7 +/- 0.5 mu m), body thickness-4.7-5.3 mu m (4.9 +/- 0.2 mu m) and caudal process length-38.0-41.2 mu m (38.3 +/- 2.9 mu m). The polar capsules were elongated and of unequal size, with lengths of 6.3-6.8 mu m (6.5 +/- 0.2) and 6.2-6.6 mu m (6.3 +/- 0.1) for the longest and shortest axes, respectively. Capsule width was 1.4-1.6 mu m (1.5 +/- 0.1). Histological analysis showed that the plasmodia occurred in the tunica adventitia of the gall bladder and were delimited by a thin capsule of connective tissue. In the gill arch, the plasmodia were also surrounded by connective tissue similar to the endomesium, of striated skeletal muscle cells. Sixty-five juvenile specimens of A. gigas weighing 1.0-25.0 kg were examined, 17 (26.1%) of which were infected. Of these, 14 (82.3%) had cysts in the gall bladder, two (11.7%) had cysts in the gill arch and only one (5.9%) had cysts in both organs. When the fish were grouped by weight, the prevalence of infection in fish weighing up to 10.0 kg (20.7%) was significantly lower than in fish weighing 10.1-25.0 kg (50%) (G = 3.93; d.f. = 1; p < 0.05). (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to develop a fast capillary electrophoresis method for the determination of benzoate and sorbate ions in commercial beverages. In the method development the pH and constituents of the background electrolyte were selected using the effective mobility versus pH curves. As the high resolution obtained experimentally for sorbate and benzoate in the studies presented in the literature is not in agreement with that expected from the ionic mobility values published, a procedure to determine these values was carried out. The salicylate ion was used as the internal standard. The background electrolyte was composed of 25 mmol L(-1) tris(hydroxymethyl)aminomethane and 12.5 mmol L(-1) 2-hydroxyisobutyric acid, atpH 8.1.Separation was conducted in a fused-silica capillary(32 cm total length and 8.5 cm effective length, 50 mu m I.D.), with short-end injection configuration and direct UV detection at 200 nm for benzoate and salicylate and 254 nm for sorbate ions. The run time was only 28 s. A few figures of merit of the proposed method include: good linearity (R(2) > 0.999), limit of detection of 0.9 and 0.3 mg L(-1) for benzoate and sorbate, respectively, inter-day precision better than 2.7% (n =9) and recovery in the range 97.9-105%. Beverage samples were prepared by simple dilution with deionized water (1:11, v/v). Concentrations in the range of 197-401 mg L(-1) for benzoate and 28-144 mg L(-1) for sorbate were found in soft drinks and tea. (c) 2008 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to develop a fast capillary electrophoresis method for the determination of inorganic cations (Na(+), K(+), Ca(2+), Mg(2+)) in biodiesel samples, using barium (Ba(2+)) as the internal standard. The running electrolyte was optimized through effective mobility curves in order to select the co-ion and Peakmaster software was used to determine electromigration dispersion and buffer capacity. The optimum background electrolyte was composed of 10 mmol L(-1) imidazole and 40 mmol L(-1) of acetic acid. Separation was conducted in a fused-silica capillary (32 cm total length and 23.5 cm effective length, 50 mu m I.D.), with indirect UV detection at 214 nm. The migration time was only 36 s. In order to obtain the optimized conditions for extraction, a fractional factorial experimental design was used. The variables investigated were biodiesel mass, pH, extractant volume, agitation and sonication time. The optimum conditions were: biodiesel mass of 200 mg, extractant volume of 200 mu L. and agitation of 20 min. The method is characterized by good linearity in the concentration range of 0.5-20 mg kg(-1) (r > 0.999), limit of detection was equal to 0.3 mg kg(-1), inter-day precision was equal to 1.88% and recovery in the range of 88.0-120%. The developed method was successfully applied to the determination of cations in biodiesel samples. (c) 2010 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aim To evaluate ex vivo the accuracy of two electronic apex locators during root canal length determination in primary incisor and molar teeth with different stages of physiological root resorption. Methodology One calibrated examiner determined the root canal length in 17 primary incisors and 16 primary molars (total of 57 root canals) with different stages of root resorption based on the actual canal length and using two electronic apex locators. Root canal length was measured both visually, with the placement of a K-file 1 mm short of the apical foramen or the apical resorption bevel, and electronically using two electronic apex locators (Root ZX II - J. Morita Corp. and Mini Apex Locator - SybronEndo) according to the manufacturers` instructions. Data were analysed statistically using the intraclass correlation (ICC) test. Results Comparison of the actual root canal length and the electronic root canal length measurements revealed high correlation (ICC = 0.99), regardless of the tooth type (single-rooted and multi-rooted teeth) or the presence/absence of physiological root resorption. Conclusions Root ZX II and Mini Apex Locator proved useful and accurate for apex foramen location during root canal length measurement in primary incisors and molars.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the accuracy of electronic apex locators Digital Signal Processing (DSP) and ProPex, for root canal length determination in primary teeth. Fifteen primary molars (a total of 34 root canals) were divided into two groups: Group I - without physiological resorption (n = 16); and Group II - with physiological resorption (n = 18). The length of each canal was measured by introducing a file until its tip was visible and then it was retracted 1 mm. For electronic measurement, the devices were set to 1 mm short of the apical resorption. The data were analysed statistically using the intraclass correlation coefficient (ICC). Results showed that the ICC was high for both electronic apex locators in all situations - with (ICC: DSP = 0.82 and Propex = 0.89) or without resorption (ICC: DSP = 0.92 and Propex = 0.90). Both apex locators were extremely accurate in determining the working length in primary teeth, both with or without physiological resorption.