7 resultados para Choruses, Secular (Mixed voices) with orchestra--Vocal scores with piano
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)
Resumo:
Linear mixed models were developed to handle clustered data and have been a topic of increasing interest in statistics for the past 50 years. Generally. the normality (or symmetry) of the random effects is a common assumption in linear mixed models but it may, sometimes, be unrealistic, obscuring important features of among-subjects variation. In this article, we utilize skew-normal/independent distributions as a tool for robust modeling of linear mixed models under a Bayesian paradigm. The skew-normal/independent distributions is an attractive class of asymmetric heavy-tailed distributions that includes the skew-normal distribution, skew-t, skew-slash and the skew-contaminated normal distributions as special cases, providing an appealing robust alternative to the routine use of symmetric distributions in this type of models. The methods developed are illustrated using a real data set from Framingham cholesterol study. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
Let M = (V, E, A) be a mixed graph with vertex set V, edge set E and arc set A. A cycle cover of M is a family C = {C(1), ... , C(k)} of cycles of M such that each edge/arc of M belongs to at least one cycle in C. The weight of C is Sigma(k)(i=1) vertical bar C(i)vertical bar. The minimum cycle cover problem is the following: given a strongly connected mixed graph M without bridges, find a cycle cover of M with weight as small as possible. The Chinese postman problem is: given a strongly connected mixed graph M, find a minimum length closed walk using all edges and arcs of M. These problems are NP-hard. We show that they can be solved in polynomial time if M has bounded tree-width. (C) 2008 Elsevier B.V. All rights reserved.
Resumo:
Purpose: The aim of the present paper was to determine the effect of different types of ionizing radiation on the bond strength of three different dentin adhesive systems. Materials and Methods: One hundred twenty specimens of 60 human teeth (protocol number: 032/2007) sectioned mesiodistally were divided into 3 groups according to the adhesives systems used: SB (Adper Single Bond Plus), CB (Clearfil SE Bond) and AP (Adper Prompt Self-Etch). The adhesives were applied on dentin and photo-activated using LED (Lec 1000, MMoptics, 1000 mW/cm(2)). Customized elastomer molds (0.5 mm thickness) with three orifices of 1.2 mm diameter were placed onto the bonding areas and filled with composite resin (Filtek Z-250), which was photo-activated for 20 s. Each group was subdivided into 4 Subgroups for application of the different types of ionizing radiation: ultraviolet radiation (UV), diagnostic x-ray radiation (DX), therapeutic x-ray radiation (TX) and without irradiation (control group, CG). Microshear tests were carried out (Instron, model 4411), and afterwards the modes of failure were evaluated by optical and scanning electron microscope and classified using 5 scores: adhesive failure, mixed failures with 3 significance levels, and cohesive failure. The results of the shear bond strength test were submitted to ANOVA with Tukey`s test and Dunnett`s test, and the data from the failure pattern evaluation were analyzed with the Mann Whitney test (p = 0.05). Results: No change in bond strength of CB and AP was observed after application of the different radiation types, only SB showed increase in bond strength after UV (p = 0.0267) irradiation. The UV also changed the failure patterns of SB (p = 0.0001). Conclusion: The radio-induced changes did not cause degradation of the restorations, which means that they can be exposed to these types of ionizing radiation without weakening the bond strength.
Resumo:
Objective. The aim was to evaluate the bleaching efficacy of sodium perborate/37% carbamide peroxide paste and traditional sodium perborate/distilled water for intracoronal bleaching. Study design. Thirty patients with dark anterior teeth were divided into 2 groups (n = 15): group A: sodium perborate/ distilled water; and group B: sodium perborate/37% carbamide peroxide paste. The bleaching treatment limited each patient to the maximum of 4 changes of the bleaching agent. Initial and final color shades were measured using the Vita Lumin shade guide. Results. Data was analyzed with Wilcoxon test for initial and final comparison according to the bleaching agent, demonstrating efficacy of the bleaching treatment with both agents. Mann-Whitney test was used for comparison of the efficacy of the bleaching agents, showing that there was no significant difference between them. Conclusion. The sodium perborate/37% carbamide peroxide association for intracoronal bleaching has proven to be as effective as sodium perborate/distilled water. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2009; 107: e43-e47)
Resumo:
Objective: To develop yardsticks for assessment of dental arch relationship in young individuals with repaired complete bilateral cleft lip and palate appropriate to different stages of dental development. Participants: Eleven cleft team orthodontists from five countries worked on the projects for 4 days. A total of 776 sets of standardized plaster models from 411 patients with operated complete bilateral cleft lip and palate were available for the exercise. Statistics: The interexaminer reliability was calculated using weighted kappa statistics. Results: The interrater weighted kappa scores were between .74 and .92, which is in the ""good"" to ""very good"" categories. Conclusions: Three bilateral cleft lip and palate yardsticks for different developmental stages of the dentition were made: one for the deciduous dentition (6-year-olds` yardstick), one for early mixed dentition (9-year-olds` yardstick), and one for early permanent dentition (12-year-olds` yardstick).
Resumo:
Prediction of random effects is an important problem with expanding applications. In the simplest context, the problem corresponds to prediction of the latent value (the mean) of a realized cluster selected via two-stage sampling. Recently, Stanek and Singer [Predicting random effects from finite population clustered samples with response error. J. Amer. Statist. Assoc. 99, 119-130] developed best linear unbiased predictors (BLUP) under a finite population mixed model that outperform BLUPs from mixed models and superpopulation models. Their setup, however, does not allow for unequally sized clusters. To overcome this drawback, we consider an expanded finite population mixed model based on a larger set of random variables that span a higher dimensional space than those typically applied to such problems. We show that BLUPs for linear combinations of the realized cluster means derived under such a model have considerably smaller mean squared error (MSE) than those obtained from mixed models, superpopulation models, and finite population mixed models. We motivate our general approach by an example developed for two-stage cluster sampling and show that it faithfully captures the stochastic aspects of sampling in the problem. We also consider simulation studies to illustrate the increased accuracy of the BLUP obtained under the expanded finite population mixed model. (C) 2007 Elsevier B.V. All rights reserved.
Resumo:
Mixed-ligand complexes of technetium(V) or rhenium(V) containing tridentate N-[(dialkylamino)(thiocarbonyl)]benzamidine (H(2)L(1)) and bidentate N,N-dialkyl-N`-benzoylthiourea (HL(2)) ligands were formed in high yields when (NBu(4))[MOCl(4)] (M = Tc or Re) or [ReOCl(3)(PPh(3))(2)] was treated with mixtures of the proligands. Other approaches for the synthesis of the products are reactions of [MOCl(L(1))] complexes with HL(2) or compounds of the-composition [ReOCl(2)(PPh(3))(L(2))] with H(2)L(1). The resulting air-stable [MO(L(1))(L(2))] complexes possess potential for the development of metal-based radiopharmaceuticals. [TcO(L(1))(L(2))] complexes are readily reduced by PPh3 with formation of [Tc(L(1))(L(2))(PPh(3))]. The resulting Tc(III) complexes undergo two almost-reversible oxidation steps corresponding to one-electron transfer processes. ((C) Wiley-VCH Verlag GmbH & Co. KGaA, 69451 Weinheim, Germany, 2009)