99 resultados para Cataract Surgery
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)
Resumo:
PURPOSE: To determine whether implantation of an aspherical intraocular lens (IOL) results in reduced ocular aberrations and improved contrast sensitivity after cataract surgery without critical reduction of depth of focus. DESIGN: Double-blinded, randomized, prospective study. METHODS: In an intraindividual study of 25 patients with bilateral cataract, an aspherical IOL (Akreos Advanced Optic [AO]; Bausch & Lomb, Inc., Rochester, New York, USA) was implanted in one eye and a spherical IOL (Akreos Fit; Bausch & Lomb, Inc) in the fellow eye. Higher-order aberrations with a 5- and 6-mm pupil were measured with a dynamic retinoscopy aberrometer at 1 and 3 months after surgery. Uncorrected and best-corrected visual acuity and contrast sensitivity under mesopic and photopic conditions also were measured. Distance-corrected near and intermediate visual acuity were studied as a measurement of depth of focus. RESULTS: There was no statistically significant difference between eyes in uncorrected and best-corrected visual acuity at I and 3 months after surgery. There was a statistically significant between-group difference in contrast sensitivity under photopic conditions at 12 cycles per degree and under mesopic conditions at all spatial frequencies. The Akreos AO group obtained statistically significant lower values of higher-order aberrations and spherical aberration with 5- and 6-mm pupils compared with the Akreos Fit group (P < .05). There was no significant difference in distance-corrected near and intermediate visual acuity between both groups. CONCLUSIONS: Aspherical aberration-free Akreos AO IOL induced significantly less higher-order aberrations and spherical aberration than the Akreos Fit. Contrast sensitivity was better under mesopic conditions with the Akreos AO with similar results of depth of focus. (Am J Ophthalmol 2010;149:383-389. (C) 2010 by Elsevier Inc. All rights reserved.)
Resumo:
Objective. Estimate cataract surgical rates (CSR) for Brazil and each federal unit in 2006 and 2007 based on the number of surgeries performed by the Unified Health System to help plan a comprehensive ophthalmology network in order to eliminate cataract blindness in compliance with the target set by the World Health Organization (WHO) of 3 000 cataract surgeries per million inhabitants per year. Methods. This descriptive study calculates CSR by using the number of cataract surgeries carried out by the Brazilian Unified Health System for each federal unit and estimates the need for cataract surgery in Brazil for 2006-2007, with official population data provided by the Brazilian Institute of Geography and Statistics. The number of cataract surgeries was compared with the WHO target. Results. To reach the WHO goal for eliminating age-related cataract blindness in Brazil, 560 312 cataract surgeries in 2006 and 568 006 surgeries in 2007 needed to be done. In 2006, 179 121 cataract surgeries were done by the Unified Health System, corresponding to a CSR of 959 per million population; in 2007, 223 317 were performed, with a CSR of 1 179. With the Brazilian Council of Ophthalmology estimation of 165 000 surgeries each year by the non-public services, the CSR for Brazil would be 1 842 for 2006 and 2 051 for 2007. The proportions needed to achieve the proposed target were 38.6% in 2006 and 31.6% in 2007. Conclusions. Human resources, technical expertise, and equipment are crucial to reach the WHO goal. Brazil has enough ophthalmologists but needs improved planning and infrastructure in order to eliminate the problem, aspects that require greater financial investment and stronger political commitment.
Resumo:
Objective: To estimate the prevalence of blindness in the elderly population of Campinas, Brazil, and to describe the coverage and quality of cataract surgery services in the area. Methods: A brief assessment of cataract surgery services (using the RACSS (Rapid Assessment of Cataract Surgical Services Method) was conducted using random cluster sampling, with a sample composed of 60 clusters of 40 people aged 50 years or older. Visual acuity (VA) was measured and the lens status observed by direct visual ophthalmoscopy. From the selected sample of 2,400 subjects, 92.67% were examined. Results: Blindness (VA 3/60 with available correction) was found in 1.98 % (2.03 % among male subjects, and 1.94 % among female subjects). The prevalence of blindness varied with age, from 0.2%, in the group from 50 to 54 years, to 7.2% in those above 80. Cataract was the main cause of blindness (40.2%) followed by suspected posterior segment disorders (18.2%), diabetic retinopathy (15.9%), and glaucoma (11.4%). The cataract surgical coverage was of 93% (VA 3/60) and 82.18% when the criterion was VA 6/60 in the best eye. The main reasons the subjects did not receive surgical treatment were: fear of undergoing surgery, 11.1%; lack of awareness about the condition, 16.7%; waiting for maturity, 16.7%; and contraindication to surgery, 44.4%. Conclusion: Cataract is the major cause of blindness in Campinas. Education on eye diseases, their prevention and treatment must become part of the city`s public healthcare policies.
Resumo:
Purpose: To compare the level of sedation of oral administration of diazepam or midazolam associated or not with clonidine and their effects on upper eyelid margin position, heart rate, arterial pressure, and oxygen saturation. Methods: Seventy consecutive healthy patients American Society of Anesthesiologists (ASA) grade I-II scheduled for lower eyelid blepharoplasty were randomized into 4 groups according to the oral sedative agent used (group 1, diazepam 10 mg; group 2, diazepam 10 mg plus clonidine 0.15 mg; group 3, midazolam 15 mg; group 4, midazolam plus clonidine 0.15 mg). For all patients, the midpupil-to-upper eyelid margin distance, the heart rate, systolic and diastolic blood pressure, and oxygen saturation were recorded before and 1 hour after the administration of oral medication. The level of sedation at the time of surgery was measured with the Michigan University scale. Results: The depth of sedation was significantly more pronounced with midazolam (median score = 2) than with diazepam (median score = 1). Clonidine slightly increased the level of sedation of both diazepam and midazolam. The diastolic arterial blood pressure drop with midazolam associated or not with clonidine was significantly greater than with diazepam. The mean upper eyelid margin position shift (-1.42 mm) verified when clonidine was associated with midazolam was also significantly greater than with diazepam. Discussion: Oral sedation with diazepam or midazolam associated or not with clonidine is safe for ASA grade I-II patients. The systemic effects of diazepam and midazolam were small and very similar. The sedation induced by midazolam was clearly greater than that induced by diazepam. However, this higher level of sedation was accompanied by a more important shift in upper eyelid margin position.
Resumo:
OBJETIVO: Verificar em dois grupos de pacientes com visão monocular (grupo 1) e com visão binocular (grupo 2), a serem submetidos à cirurgia de catarata num hospital universitário, opiniões em relação ao problema ocular, à qualidade da visão e à cirurgia de catarata. MÉTODOS: Foi realizado estudo transversal e comparativo, de forma consecutiva, por meio de questionário estruturado, aplicado por entrevista a pacientes, elaborado a partir de estudo exploratório e medidas acuidade visual e causa da perda visual. RESULTADOS: A amostra foi constituída por 96 indivíduos do grupo 1 (50,0% homens; 50,0% mulheres, com idade entre 41 e 91 anos, média 69,3 anos ± 10,4 anos) e 110, do grupo 2 (40,9% homens; 59,1% mulheres, com idade entre 40 e 89 anos, média 68,2 anos ± 10,2 anos). A maioria dos indivíduos de ambos os grupos apresentava baixa escolaridade. Não houve diferença estatisticamente significante entre os grupos em relação ao sexo (p=0,191), à idade (p=0,702) e à escolaridade (p=0,245). Não exerciam atividade laboral 95,8% dos indivíduos do grupo 1 e 83,6%, do grupo 2 (p=0,005) e 30,4% do grupo 1 mencionaram não ter possibilidade de trabalhar por causa da deficiência visual. Observou-se acuidade visual do olho a ser operado menor que 0,05 em 40,6% (grupo 1) e 33,6% (grupo 2), entre 0,25 e 0,05. Quase a totalidade dos indivíduos de ambos os grupos afirmou ter dificuldade para realização das atividades de vida diária e qualificou como insuficiente a respectiva acuidade visual; 71,9% dos entrevistados do grupo 1 e 71,6%, do grupo 2 mencionaram saber a causa da visão fraca; desses, 87,1% do grupo 1 e 83,3% do grupo 2 referiram a catarata como causa da baixa acuidade visual. CONCLUSÃO: Os indivíduos de ambos os grupos tiveram acesso à cirurgia de catarata com acuidade visual menor do que a idealmente indicada; os pacientes com visão monocular apresentaram acuidade visual significativamente menor em relação aos com visão binocular; a maioria dos entrevistados de ambos os grupos referiu dificuldades para realizar atividades cotidianas como consequência da baixa visão; muitos indivíduos de ambos os grupos desconheciam a causa da dificuldade visual ou a atribuíram a outra causa que não a catarata.
Resumo:
P>Background: We aimed to evaluate the ascorbic acid concentration in secondary aqueous humour (AH) from glaucomatous patients and to compare it with primary AH from primary open-angle glaucoma patients and non-glaucomatous patients. Methods: Primary AH samples were prospectively obtained from clinically uncontrolled primary open-angle glaucoma patients and senile cataract patients (controls) prior to trabeculectomy and cataract surgery. Secondary AH samples were obtained from eyes with previous intraocular surgery, prior to trabeculectomy or cataract surgery. AH (0.1 mL) was aspirated by inserting a 26-gauge needle into the anterior chamber just before surgery and then immediately stored at -80 degrees C. The ascorbic acid concentration was determined in a masked fashion by high-pressure liquid chromatography. Results: A total of 18 patients with senile cataract, 16 glaucomatous patients with primary AH (no previous intraocular surgery) and 11 glaucomatous patients with secondary AH (previous intraocular surgery) were included. There was no difference in mean age between groups (P = 0.15). The mean +/- standard deviation concentration of ascorbic acid in the secondary AH from glaucomatous patients (504 +/- 213 mu mol/L [95% confidence interval {CI}, 383-624]) was significantly lower than the concentration of ascorbic acid found in the primary aqueous of primary open-angle glaucoma (919 +/- 427 mu mol/L [95% CI, 709-1128]) and control patients (1049 +/- 433 mu mol/L [95% CI, 848-1249]; P < 0.01, Kruskal-Wallis test). Conclusions: The ascorbic acid concentration in secondary AH of glaucomatous patients was approximately twofold lower in comparison with primary AH of glaucomatous and cataract patients. The implications of a reduced concentration of ascorbic acid in the secondary AH deserve further investigation.
Resumo:
Purpose: To evaluate wavefront performance and modulation transfer function (MTF) in the human eye aft er the implantation of diffractive or refractive multifocal intraocular lenses (IOLs). Materials and Methods: This was a prospective, interventional, comparative, nonrandomized clinical study. Uncorrected distance and near visual acuity, and wavefront analysis including MTF curves (iTrace aberrometer, Tracey Technologies, Houston, TX, USA) were measured in 60 patients aft er bilateral IOL implantation with 6 months of follow-up. Forty eyes received the diffractive ReSTOR (Alcon), 40 eyes received the refractive ReZoom (Advanced Medical Optics) and 40 eyes, the Tecnis ZM900 (Advanced Medical Optics). The comparison of MTF and aberration between the intraocular lenses was performed using analysis of variance (ANOVA), followed by the Dunn test when necessary. Results: The mean uncorrected distance visual acuity was similar in all three groups of multifocal IOLs. The ReSTOR group provided better uncorrected near visual acuity than the ReZoom group (P < 0.001), but similar to the Tecnis group. Spherical aberration was significantly higher in the ReZoom group (P = 0.007). Similar MTF curves were found for the aspheric multifocal IOL Tecnis and the spheric multifocal IOL ReSTOR, and both performed better than the multifocal IOL ReZoom in a 5 mm pupil (P < 0.001 at all spatial frequencies). Conclusions: Diffractive IOLs studied presented similar MTF curves for a 5 mm pupil diameter. Both diffractive IOLs showed similar spherical aberration, which was significantly better with the full-diffractive IOL Tecnis than with the refractive IOL ReZoom.
Resumo:
PURPOSE: To determine whether implantation of an intraocular lens (IOL) with an aspheric surface (Akreos AO, Bausch & Lomb Inc) results in reduced ocular aberrations (spherical aberration) and improved Strehl ratio and modulation transfer function (MTF) after cataract surgery. METHODS: In an intraindividual, randomized, double-masked, prospective study of 50 eyes (25 patients) with bilateral cataract, an IOL with modified anterior and posterior surfaces (Akreos AO) was implanted in one eye and a biconvex IOL with spherical surfaces (Akreos Fit, Bausch & Lomb Inc) implanted in the fellow eye. Ocular aberrations, Strehl ratio, and MTF curve with 4.5-, 5.0-, and 6.0-mm pupils were measured with a NIDEK OPD-Scan dynamic retinoscopy aberrometer 3 months after surgery. Uncorrected and corrected distance visual acuity (UDVA and CDVA, respectively) were also measured. RESULTS: No statistically significant difference was noted between eyes in postoperative UDVA and CDVA at 1 month. At 3 months, the Akreos AO IOL group obtained statistically significant lower values of higher order and spherical aberrations with 4.5-, 5.0-, and 6.0-mm pupil diameters than the Akreos Fit IOL group (P<.05). The value of Strehl ratio was statistically significantly higher in eyes with the Akreos AO IOL for 4.5- and 6.0-mm pupils (P<.05). The MTF curve was better in the Akreos AO IOL group in 4.5-, 5.0-, and 6.0-mm pupils (P<.05). CONCLUSIONS: The aspheric Akreos AO IOL induced significantly less spherical aberration than the Akreos Fit IOL for 4.5-, 5.0-, and 6.0-mm pupils. Modulation transfer function and Strehl ratio were also better in eyes implanted with the Akreos AO IOL than the Akreos Fit. [J Refract Surg. 2011;27(4):287-292.] doi:10.3928/1081597X-20100714-01
Resumo:
PURPOSE To compare reading ability after cataract surgery and bilateral implantation of multifocal intraocular lenses (IOLs) with a +3 00 diopter (D) addition (add) or a +4 00 D add SETTING Department of Ophthalmology, University of Sao Paulo, Sao Paulo, Brazil DESIGN Prospective comparative study METHODS Patients scheduled for cataract surgery were randomly assigned to bilateral implantation of an aspheric AcrySof ReSTOR multifocal IOL with a +3 00 diopter (D) addition (add) or a +4 00 D add The reading speed, critical print size, and reading acuity were measured binocularly with best correction using MNREAD acuity charts 6 months after surgery Patients were tested with the chart at the best patient-preferred reading distance and at 40 cm Binocular uncorrected and best distance-corrected visual acuities at far and near were also measured RESULTS The study enrolled 32 patients At the best reading distance the results were similar between the 2 IOL groups in all reading parameters When tested at 40 cm, reading speed at all print sizes from 03 to 00 (all P< 001), critical print size (P< 001) and reading acuity (P = 014) were statistically significantly better in the +3 00 D IOL group than in the +4 00 DIOL group Uncorrected and corrected visual acuities at far and near were similar between the 2 groups CONCLUSION Although the 2 IOL groups had similar performance in reading parameters, patients had to adjust to their best reading distance The +3 00 D IOL performed better than the +4 00 D IOL at 40 cm
Trypan blue staining for capsulorhexis: Ultrastructural effect on lens epithelial cells and capsules
Resumo:
PURPOSE: To evaluate the ultrastructural effect of trypan blue 0.1% staining for capsulorhexis on lens epithelial cells (LECs) and capsules SETTING: Division of Ophthalmology. University of Sao Paulo, Sao Paulo, Brazil METHODS: Before capsulorhexis, patients were randomly assigned to 1 of 2 groups Trypan blue 0 1% staining was performed in the treatment group No trypan blue was used in the control group Samples of capsules with LECs were fixed and analyzed with routine optical microscopy techniques. immunohistochemistry for beclin-1 expression (a marker of autophagy), terminal deoxynucleotidyl transf erase-mediated dUTP-biotin nick-end labeling to detect apoptosis, and transmission electron microscopy (TEM) Morphometric analyses were performed. and the 2 sets of data were compared. RESULTS: Each group comprised 15 patients Cell death by autophagy and apoptosis was observed in the treatment group but not in the control group The TEM images of subcapsular epithelium cells showed mitochondria` rupture, dilation of the cisterns of the endoplasmic reticulum, increased cytoplasmic and nuclear electron density, and abnormalities in the nuclear profile of trypan blue-stained cells. Morphometric analysis showed statistically significant differences between the 2 groups in the longest nuclear axes and the ratio between the total nuclear perimeter and the cell area (P = .03) The difference in capsule thickness between groups was not significant. CONCLUSION: Trypan blue caused LEC death, which supports the hypothesis that staining with trypan blue 0 1% can help reduce the incidence of posterior capsule pacification after cataract surgery
Resumo:
PURPOSE: To evaluate the advantages and disadvantages of the new low-addition (add) (+3.00 diopter [D]) ReSTOR multifocal IOL compared with the preceding ReSTOR model with +4.00 D add. SETTING: University Eye Hospital, Tuebingen, Germany. DESIGN: Comparative case series. METHODS: Patients with a +3.00 D or +4.00 D add multifocal IOL were examined for uncorrected and distance-corrected visual acuity at distance, intermediate, and near. A defocus profile was assessed, individual reading distance and the distance for lowest intermediate visual acuity were determined. Patient satisfaction was evaluated with a standardized questionnaire. Contrast sensitivity was tested under mesopic and photopic conditions. RESULTS: Uncorrected and distance-corrected intermediate visual acuities were statistically significantly better in the +3.00 D add group (24 eyes) than in the +4.00 D add group (30 eyes); distance and near visual acuities were not different between groups. The defocus profile significantly varied between groups. The +4.00 D add group had a closer reading distance (33.0 cm) than the +3.00 D add group (43.5 cm), a closer point of lowest intermediate visual acuity (65.8 cm versus 86.9 cm) and worse lowest intermediate visual acuity (20/59 +/- 4.5 letters [SD] versus 20/48 +/- 5.5 letters). Thus, patients in the +3.00 D add group reported being more satisfied with intermediate visual acuity. The +3.00 D add group reported more glare but less halos than the +4.00 D add group; contrast sensitivity was not different. CONCLUSION: The lower addition resulted in a narrower defocus profile, a farther reading distance, and better intermediate visual acuity and thus increased patient satisfaction.
Resumo:
Background/aims To compare two intraocular irrigating solutions, Balanced Salt Solution Plus (BSS Plus) versus Lactated Ringer`s (Ringer), for the preservation of corneal integrity after phacoemulsification. Methods 110 patients undergoing phacoemulsification were randomised to either BSS Plus (n = 55) or Ringer (n = 55) as the irrigating solution. Patients were examined at baseline and at 1, 8, 15, 30 and 60 days postoperatively. Evaluations included specular microscopy to evaluate endothelial cell density (ECD) and endothelial cell size variability (CV), and corneal pachymetry for central corneal thickness (CCT) measurement. Results Groups were well balanced regarding baseline ECD, CV and CCT (p>0.05). There was no statistically significant difference between ECD reduction in group BSS Plus 13.1 +/- 2.0% and Ringer 9.2 +/- 1.9% (p<0.05) at day 60 or in any study visit. There was no statistically significant difference between CV increase in group BSS Plus 23.0 +/- 3.0% and Ringer 20.2 +/- 4.0% (p<0.05) at day 60 or in any study visit. CCT was significantly increased (p<0.05) at 1, 8, 15 and 30 days postoperatively, returning to baseline at 60 days in both groups. There was no significant difference in CCT increase in both groups at any visit. Interestingly, there were statistically significant correlations between ECD loss and phacoemulsification time (p<0.0001) and ECD loss and irrigation solution volume (p<0.0001) in the Ringer group, but not in the BSS Plus group. Conclusions Ringers solution was similar to BSS Plus for corneal preservation in atraumatic cataract surgery. However, our study demonstrates that there is a trend towards lower postoperative endothelial cell density for surgeries with longer phacoemulsification time and higher irrigation volumes if Ringer is used.
Resumo:
The aim of this study was to evaluate in situ changes in the alveolar crest bone height around immediate implant-supported crowns in comparison to tooth-supported crowns (control) with the cervical margins located at the bone crest level, without occlusal load. In Group I, after extraction of 12 mandibular premolars from 4 adult dogs, implants from Branemark System (MK III TiU RP 4.0 x 11.5 mm) were placed to retain complete acrylic crowns. In Group II, premolars were prepared to receive complete metal crowns. Sixteen weeks after placement of the crowns (38 weeks after tooth extraction), the height of the alveolar bone crest was measured with a digital caliper. Data were analyzed statistically by the Mann-Whitney test at 5% significance level. The in situ analysis showed no statistically significant difference (p=0.880) between the implant-supported and the tooth-supported groups (1.528 + 0.459 mm and 1.570 + 0.263 mm, respectively). Based on the findings of the present study, it may be concluded that initial peri-implant bone loss may result from the remodeling process necessary to establish the biological space, similar to which occurs with tooth-supported crowns.
Resumo:
We report a case of a 67 year-old-male patient admitted to the intensive care unit in the post-coronary bypass surgery period who presented cardiogenic shock, acute renal failure and three episodes of sepsis, the latter with pulmonary distress at the 30th post-operative day. The patient expired within five days in spite of treatment with vancomycin, imipenem, colistimethate and amphotericin B. At autopsy severe adenovirus pneumonia was found. Viral pulmonary infections following cardiovascular surgery are uncommon. We highlight the importance of etiological diagnosis to a correct treatment approach.
Resumo:
The efficacy of breast-conserving surgery for the local control of early breast cancer has been repeatedly evidenced. Although immediate reconstruction following breast-conserving surgery has been described, little information is available regarding surgical management in reoperative settings due to positive margins. We studied the influence of intraoperatively assessed and postoperatively controlled surgical margin status on the type of breast-conserving surgery and report our results regarding complications in a reoperative breast reconstruction scenario. All patients were seen by a multidisciplinary team who recommended breast-conserving surgery. According to the breast volume, ptosis and tumor size/location, the patients were also evaluated by a plastic surgeon, who recommended reconstruction with the appropriate technique. Intraoperative assessment of surgical margins was determined by histological examination of frozen sections. The mean follow-up time was 48months. Two hundred and eighteen patients (88.5 per cent ) underwent breast-conserving surgery and immediate reconstruction. Twelve (5.5 per cent ) patients had a positive tumor margin after review of the permanent section. All patients underwent re-exploration. In 1.3 per cent , a second reconstructive technique was indicated and in 2.2 per cent a skin-sparing mastectomy with total reconstruction was performed. Our findings support the important role of the intraoperative assessment of surgical margins and its interference in the selection of reconstruction techniques and negative margins; however, it will not guarantee complete excision of the tumor. Success depends on coordinated planning with the oncologic surgeon and careful intraoperative management