115 resultados para COMPARATIVE PHARMACOKINETICS
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)
Resumo:
Objective-To evaluate the effects of increasing doses of remifentanil hydrochloride administered via constant rate infusion (CRI) on the minimum alveolar concentration (MAC) of isoflurane in cats. Animals-6 healthy adult cats. Procedures-For each cat, 2 experiments were performed (2-week interval). On each study day, anesthesia was induced and maintained with isoflurane; a catheter was placed in a cephalic vein for the administration of lactated Ringer`s solution or remifentanil CRIs, and a catheter was placed in the jugular vein for collection of blood samples for blood gas analyses. On the first study day, individual basal MAC (MAC(Basal)) was determined for each cat. On the second study day, 3 remifentanil CRIs (0.25, 0.5, and 1.0 mu g/kg/min) were administered (in ascending order); for each infusion, at least 30 minutes elapsed before determination of MAC (designated as MAC(R0.25`) MAC(R0.5`) and MACR(R1.0`) respectively). A 15-minute washout period was allowed between CRIs. A control MAC (MAC Control) was determined after the last remifentanil infusion. Results-Mean +/- SD MAC(Basal) and MAC(Control) values at sea level did not differ significantly (1.66 +/- 0.08% and 1.52 +/- 0.21%, respectively). The MAC values determined for each remifentanil CRI did not differ significantly. However, MACR(0.25`) MAC(R0.5`) and MAC(R1.0) were significantly decreased, compared with MAC(Basal`) by 23.4 +/- 79%, 29.8 +/- 8.3%, and 26.0 +/- 9.4%, respectively. Conclusions and Clinical Relevance-The 3 doses of remifentanil administered via CRI resulted in a similar degree of isoflurane MAC reduction in adult cats, indicating that a ceiling effect was achieved following administration of the lowest dose. (Am J Vet Res 2009;70:581-588)
Resumo:
In the present study a fast, sensitive and robust validated method to quantify chlorpheniramine in human plasma using brompheniramine as internal standard (IS) is described. The analyte and the IS were extracted from plasma by LLE (diethyl ether-dichloromethane, 80:20, v/v) and analyzed by HPLC-ESI-MS/MS. Chromatographic separation was performed using a gradient of methanol from 35 to 90% with 2.5 mm NH(4)OH on a Gemini Phenomenex C(8) 5 mu m column (50 x 4.6 mm i.d.) in 5.0 min/run. The method fitted to a linear calibration curve (0.05-10 ng/mL, R > 0.9991). The precision (%CV) and accuracy ranged, respectively: intra-batch from 1.5 to 6.8% and 99.1 to 106.6%, and inter-batch from 2.4 to 9.0%, and 99.9 to 103.1%. The validated bioanalytical procedure was used to assess the comparative bioavailability in healthy volunteers of two dexchlorpheniramine 2.0 mg tablet formulations (test dexchlorpheniramine, Eurofarma, and reference Celestamine (R), Schering-Plough). The study was conducted using an open, randomized, two-period crossover design with a 2 week washout interval. Since the 90% confidence interval for C(max) and AUC ratios were all within the 80-125% interval proposed by ANVISA and FDA, it was concluded that test and reference formulations are bioequivalent concerning the rate and the extent of absorption. Copyright (C) 2009 John Wiley & Sons, Ltd.
Resumo:
Objective: To assess the comparative bioavailability of two formulations (250 mg/5 mL suspension) of cefuroxime axetil (CAS 64544-07-6), administered with food, in healthy volunteers of both sexes. Methods: The study was conducted using an open, randomized, two-period crossover design with a 1-week washout interval. Plasma samples were obtained for up to 12 h post dose. Plasma cefuroxime axetil concentrations were analyzed by liquid chromatography coupled with tandem mass spectrometry (LC-MS-MS) with negative ion electrospray ionization using multiple reactions monitoring (MRM). From the cefuroxime axetil plasma concentration vs. time curves, the following pharmacokinetic parameters were obtained: AUC(last) and C(max). Results: The limit of quantification was 0.1 mu g/mL for plasma cefuroxime axetil analysis. The geometric mean and 90% confidence interval CI of test/reference product percent ratios were: 106.1% (100.8%-111.8%) for C(max), 109.4% (104.8%-114.2%) for AUC(last). Conclusion: Since the 90% Cl for AUC(last) and C(max) ratios were within the 80-125 % interval proposed by the US FDA, it was concluded that cefuroxime axetil (test formulation, 250 mg/5 mL suspension) was bioequivalent to a reference formulation under fed conditions, for both the rate and extent of absorption.
Resumo:
Objective: To assess the bioequivalence of three ibuprofen formulations (Test formulation: ibuprofen (400 mg capsule) manufactured by Cardinal Health Brasil 402 Ltda. (Sorocaba, Brazil) and licensed to Boehringer Ingelheim do Brasil Quim. e Farm. Ltda. (Sao Paulo, Brazil); Reference formulation (1): ibuprofen (Advil (R); 2 x 200 mg coated tablet) from Wyeth-Whitehall Ltda. (Itapevi, Brazil); Reference formulation (2): ibuprofen (Alivium (R); 8 ml x 50 mg/ml solution) from Schering Plough S.A. (Rio de Janeiro, Brazil)) in 24 healthy volunteers of both sexes. Methods: The study was conducted using an open, randomized, three-period crossover design with at least 5-day washout interval. Plasma samples were obtained over a 24-h period. Plasma ibuprofen concentrations were analyzed by liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) with negative ion electrospray ionization using multiple reaction monitoring (MRM). The following pharmacokinetic parameters were obtained from the ibuprofen plasma concentration vs. time curves: AUC(last), AUC(trunctmax) AUC(inf) and C-max. Results: The limit of quantification for ibuprofen was 0.1 mu g x ml(-1). The geometric mean with corresponding 90% confidence interval (CI) for Test/Reference (1) percent ratios were 114.24% (90% CI = 105.67, 123.50%) for C-max, 98.97% (90% CI = 94.69, 103.44%) for AUC(last) and 99.40% (90% CI = 95.21, 103.78%) for AUCinf. The geometric mean and respective 90% confidence interval (CI) for Test/Reference (2) percent ratios were 108.38% (90% Cl = 100.195, 117.25%) for C-max, 100.79% (90% CI = 96.39, 105.40%) for AUC(last) and 101.26% (90% CI = 96.94, 105.77%) for AUC(inf); t(max) for the 400 mg Test capsule was shorter than that for the 2 x 200 mg Reference (1) tablets (p < 0.002). Conclusion: Since the 90% CI for AUC(last), AUC(inf) and C-max ratios were within the 80 - 125% interval proposed by the US FDA, it was concluded that ibuprofen formulation manufactured by Cardinal Health Brasil 402 Ltda. and licensed to Boehringer Ingelheim do Brasil Quim. e Farm. Ltda. is bioequivalent to the Advil (R) and Alivium (R) formulations with regard to both the rate and the extent of absorption.
Resumo:
The aim of this study was to comparatively assess dental arch width, in the canine and molar regions, by means of direct measurements from plaster models, photocopies and digitized images of the models. The sample consisted of 130 pairs of plaster models, photocopies and digitized images of the models of white patients (n = 65), both genders, with Class I and Class II Division 1 malocclusions, treated by standard Edgewise mechanics and extraction of the four first premolars. Maxillary and mandibular intercanine and intermolar widths were measured by a calibrated examiner, prior to and after orthodontic treatment, using the three modes of reproduction of the dental arches. Dispersion of the data relative to pre- and posttreatment intra-arch linear measurements (mm) was represented as box plots. The three measuring methods were compared by one-way ANOVA for repeated measurements (α = 0.05). Initial / final mean values varied as follows: 33.94 to 34.29 mm / 34.49 to 34.66 mm (maxillary intercanine width); 26.23 to 26.26 mm / 26.77 to 26.84 mm (mandibular intercanine width); 49.55 to 49.66 mm / 47.28 to 47.45 mm (maxillary intermolar width) and 43.28 to 43.41 mm / 40.29 to 40.46 mm (mandibular intermolar width). There were no statistically significant differences between mean dental arch widths estimated by the three studied methods, prior to and after orthodontic treatment. It may be concluded that photocopies and digitized images of the plaster models provided reliable reproductions of the dental arches for obtaining transversal intra-arch measurements.
Resumo:
This study evaluated the effect of chemical and mechanical surface treatments for cast metal alloys on the bond strength of an indirect composite resin (Artglass) to commercially pure titanium (cpTi). Thirty cylindrical metal rods (3 mm diameter x 60 mm long) were cast in grade-1 cpTi and randomly assigned to 6 groups (n=5) according to the received surface treatment: sandblasting; chemical treatment; mechanical treatment - 0.4 mm beads; mechanical treatment - 0.6 mm beads; chemical/mechanical treatment - 0.4 mm; and chemical/mechanical treatment - 0.6 mm beads. Artglass rings (6.0 mm diameter x 2.0 mm thick) were light cured around the cpTi rods, according manufacturer's specifications. The specimens were invested in hard gypsum and their bond strength (in MPa) to the rods was measured at fracture with a universal testing machine at a crosshead speed of 2.0 mm/min and 500 kgf load cell. Data were analyzed statistically by one-way ANOVA and Tukey test (a=5%). The surface treatments differed significantly from each other (p<0.05) regarding the recorded bond strengths. Chemical retention and sandblasting showed statistically similar results to each other (p=0.139) and both had significantly lower bond strengths (p<0.05) than the other treatments. In conclusion, mechanical retention, either associated or not to chemical treatment, provided higher bond strength of the indirect composite resin to cpTi.
Resumo:
The interest in using titanium to fabricate removable partial denture (RPD) frameworks has increased, but there are few studies evaluating the effects of casting methods on clasp behavior. OBJECTIVE: This study compared the occurrence of porosities and the retentive force of commercially pure titanium (CP Ti) and cobalt-chromium (Co-Cr) removable partial denture circumferential clasps cast by induction/centrifugation and plasma/vacuum-pressure. MATERIAL AND METHODS: 72 frameworks were cast from CP Ti (n=36) and Co-Cr alloy (n=36; control group). For each material, 18 frameworks were casted by electromagnetic induction and injected by centrifugation, whereas the other 18 were casted by plasma and injected by vacuum-pressure. For each casting method, three subgroups (n=6) were formed: 0.25 mm, 0.50 mm, and 0.75 mm undercuts. The specimens were radiographed and subjected to an insertion/removal test simulating 5 years of framework use. Data were analyzed by ANOVA and Tukey's to compare materials and cast methods (α=0.05). RESULTS: Three of 18 specimens of the induction/centrifugation group and 9 of 18 specimens of plasma/vacuum-pressure cast presented porosities, but only 1 and 7 specimens, respectively, were rejected for simulation test. For Co-Cr alloy, no defects were found. Comparing the casting methods, statistically significant differences (p<0.05) were observed only for the Co-Cr alloy with 0.25 mm and 0.50 mm undercuts. Significant differences were found for the 0.25 mm and 0.75 mm undercuts dependent on the material used. For the 0.50 mm undercut, significant differences were found when the materials were induction casted. CONCLUSION: Although both casting methods produced satisfactory CP Ti RPD frameworks, the occurrence of porosities was greater in the plasma/vacuum-pressure than in the induction/centrifugation method, the latter resulting in higher clasp rigidity, generating higher retention force values.
Resumo:
PURPOSE: Maxillary sinus lifting is a technique, in which, a possible complication is sinus membrane perforation. The aim of this study was to compare two techniques using ultrasound surgery to perform autogenous graft for maxillary sinus lifting. METHODS: Ten rabbits were used in the study, one of them did not undergo surgery. The other nine rabbits had their maxillary sinuses filled with autogenous bone grafts collected from the external skull diploe in particulate form on the right side, and shaved on the left side, both with ultrasonic device. Data on bone density in left and right maxillary sinus, obtained by computed tomography in transverse and longitudinal sections, recorded 90 days after the grafts, were statistically compared. RESULTS: There were no statistically significant differences between the two techniques that used shaved and particulate bone collected by means of ultrasonic device from rabbit skulls. CONCLUSION: Assessment of operative procedures led to the conclusion that piezoelectric ultrasound was shown to be a safe tool in the surgical approach to the maxillary sinus of rabbits, allowing sinus membrane integrity to be maintained during surgical procedures.
Resumo:
This study compared the mandibular displacement from three methods of centric relation record using an anterior jig associated with (A) chin point guidance, (B) swallowing (control group) and (C) bimanual manipulation. Ten patients aged 25-39 years were selected if they met the following inclusion criteria: complete dentition (up to the second molars), Angle class I and absence of signs and symptoms of temporomandibular disorders and diagnostic casts showing stability in the maximum intercuspation (MI) position. Impressions of maxillary and mandibular arches were made with an irreversible hydrocolloid impression material. Master casts of each patient were obtained, mounted on a microscope table in MI as a reference position and 5 records of each method were made per patient. The mandibular casts were then repositioned with records interposed and new measurements were obtained. The difference between the two readings allowed measuring the displacement of the mandible in the anteroposterior and lateral axes. Data were analyzed statistically by ANOVA and Tukey's test at 5% significance level. There was no statistically significant differences (p>0.05) among the three methods for measuring lateral displacement (A=0.38 ± 0.26, B=0.32 ± 0.25 and C=0.32 ± 0.23). For the anteroposterior displacement (A=2.76 ± 1.43, B=2.46 ± 1.48 and C=2.97 ± 1.51), the swallowing method (B) differed significantly from the others (p<0.05), but no significant difference (p>0.05) was found between chin point guidance (A) and bimanual manipulation (C). In conclusion, the swallowing method produced smaller mandibular posterior displacement than the other methods.
Resumo:
The purpose of this study was to test the hypothesis that both human and bovine sclerotic dentin have similar hardness properties, in addition to similar micromorphological characteristics. Sixteen teeth (8 human and 8 bovine) exhibiting exposed dentin in the incisal edge and showing characteristics typical of sclerosis were used. Vickers surface microhardness testing was conducted. Three areas of the dentin surface of each specimen were selected. All teeth were processed for scanning electron microscopy in order to estimate the amount (in percentage) of solid dentin on the sclerotic dentin surface. The data were compared by Student's t test (α = 0.05). The micromorphological and microhardness data were compared by Pearson's linear correlation test (α = 0.05). The mean percentages of solid dentin of human and bovine sclerotic dentin were similar (human 90.71 ± 0.83 and bovine 89.08 ± 0.81, p = 0.18). The mean microhardness value (VHN) of human sclerotic dentin was significantly higher than that of bovine sclerotic dentin (human 45.26 ± 2.92 and bovine 29.93 ± 3.83, p = 0.006). No correlation was found between the microhardness values and the amount of solid dentin in the sclerotic dentin, irrespective of the species considered (human R² = 0.0240, p = 0.714; bovine R² = 0.0017, p = 0.923; and combined R² = 0.038, p = 0.46). We concluded that although both bovine and human sclerotic dentin present a similar amount of solid tissue, human sclerotic dentin presents higher microhardness than bovine sclerotic dentin.
Resumo:
Cross-amplification was tested and variability in microsatellite primers (designed for Neotropical parrots) compared, in five macaw species, viz., three endangered blue macaws (Cyanopsitta spixii [extinct in the wild], Anodorhynchus leari [endangered] and Anodorhynchus hyacinthinus [vulnerable]), and two unthreatened red macaws (Ara chloropterus and Ara macao). Among the primers tested, 84.6% successfully amplified products in C. spixii, 83.3% in A. leari, 76.4% in A. hyacinthinus, 78.6% in A. chloropterus and 71.4% in A. macao. The mean expected heterozygosity estimated for each species, and based on loci analyzed in all the five, ranged from 0.33 (A. hyacinthinus) to 0.85 (A. macao). As expected, the results revealed lower levels of genetic variability in threatened macaw species than in unthreatened. The low combined probability of genetic identity and the moderate to high potential for paternity exclusion, indicate the utility of the microsatellite loci set selected for each macaw species in kinship and population studies, thus constituting an aid in planning in-situ and ex-situ conservation.
Resumo:
Er:YAG laser has been studied as a potential tool for restorative dentistry due to its ability to selectively remove oral hard tissue with minimal or no thermal damage to the surrounding tissues. The purpose of this study was to evaluate in vitro the tensile bond strength (TBS) of an adhesive/composite resin system to human enamel surfaces treated with 37% phosphoric acid, Er:YAG laser (lambda=2.94 mum) with a total energy of 16 J (80 mJ/pulse, 2Hz, 200 pulses, 250 ms pulse width), and Er:YAG laser followed by phosphoric acid etching. Analysis of the treated surfaces was performed by scanning electron microscopy (SEM) to assess morphological differences among the groups. TBS means (in MPa) were as follows: Er:YAG laser + acid (11.7 MPa) > acid (8.2 MPa) > Er:YAG laser (6.1 MPa), with the group treated with laser+acid being significantly from the other groups (p=0.0006 and p= 0.00019, respectively). The groups treated with acid alone and laser alone were significantly different from each other (p=0.0003). The SEM analysis revealed morphological changes that corroborate the TBS results, suggesting that the differences in TBS means among the groups are related to the different etching patterns produced by each type of surface treatment. The findings of this study indicate that the association between Er:YAG laser and phosphoric acid can be used as a valuable resource to increase bond strength to laser-prepared enamel.
Resumo:
cDNA coding for two digestive lysozymes (MdL1 and MdL2) of the Musca domestica housefly was cloned and sequenced. MdL2 is a novel minor lysozyme, whereas MdL1 is the major lysozyme thus far purified from M. domestica midgut. MdL1 and MdL2 were expressed as recombinant proteins in Pichia pastoris, purified and characterized. The lytic activities of MdL1 and MdL2 upon Micrococcus lysodeikticus have an acidic pH optimum (4.8) at low ionic strength (μ = 0.02), which shifts towards an even more acidic value, pH 3.8, at a high ionic strength (μ = 0.2). However, the pH optimum of their activities upon 4-methylumbelliferyl N-acetylchitotrioside (4.9) is not affected by ionic strength. These results suggest that the acidic pH optimum is an intrinsic property of MdL1 and MdL2, whereas pH optimum shifts are an effect of the ionic strength on the negatively charged bacterial wall. MdL2 affinity for bacterial cell wall is lower than that of MdL1. Differences in isoelectric point (pI) indicate that MdL2 (pI = 6.7) is less positively charged than MdL1 (pI = 7.7) at their pH optima, which suggests that electrostatic interactions might be involved in substrate binding. In agreement with that finding, MdL1 and MdL2 affinities for bacterial cell wall decrease as ionic strength increases.
Resumo:
This study deals with detailed morphology and anatomy of 4 species of Scaphopoda and 5 species of protobranch Bivalvia. Both classes are traditionally grouped in the taxon Diasoma, which has been questioned by different methodologies, such as molecular and developmental. This study is developed under a phylogenetic methodology with the main concern in performing it in an intelligible and testable methodology. The analyzed Scaphopoda species came from the Brazilian coast and belong to the family Dentaliidae [(1) Coccodentalium carduus; (2) Paradentalium disparile] and Gadiliidae; [(3) Polyschides noronhensis, n. sp. from Fernando de Noronha Archipelago; (4) Gadila braziliensis]. These species represent the main branches of the class Scaphopoda. From protobranch bivalves, representatives of the families Solemyidae [(5) Solemya occidentalis, from Florida; S. notialis, n. sp. from S.E. Brazil], Nuculanidae [(6) Propeleda carpentieri from Florida], and Nuculidae [(7) Ennucula puelcha, from south Brazil] are included. These species represent the main branches of the basal Bivalvia. The descriptions on the anatomy of S. occidentalis and of P. carpentieri are published elsewhere. The remaining are included here, for which a complete taxonomical treatment is performed. Beyond these species, representatives of other taxa are operationally included as part of the ingroup (indices are then shared with them), as a procedure to test the morphological monophyly of Diasoma. These taxa are: two lamellibranch bivalves [(8) Barbatia - Arcidae; (9) Serratina - Tellinidae; both published elsewhere;, and Propilidium (10) Patellogastropoda, and (11) Nautilus, basal Cephalopoda, based on basal taxa. The effective outgroups are (12) Neopilina (Monoplacophora) and (13) Hanleya (Polyplacophora). The phylogenetic analysis based on morphology revealed that the taxon Diasoma is supported by 14 synapomorphies, and is separated from Cyrtosoma (Gastropoda + Cephalopoda). Although they are not the main goal of this paper, the taxa Scaphopoda and Bivalvia are supported by 8 and by 7 synapomorphies respectively. The taxon Protobranchia resulted paraphyletic. Both scaphopod orders resulted monophyletic. The obtained cladogram is: ((((Coccodentalium carduus - Paradentalium disparile) (Polyschides noronhensis - Gadila brasiliensis)) ((Solemya occidentalis - S. notialis) (Propeleda carpenteri (Ennucula puelcha (Barbatia cancellaria - Serratina capsoides))))) (Propilidium curumim - Nautilus pompilius - Lolliguncula brevis)).
Comparative descriptions of eggs from three species of Rhodnius (Hemiptera: Reduviidae: Triatominae)
Resumo:
The authors describe and compare the morphological and ultrastructural characteristics of eggs from the three most recent described species of the genus Rhodnius Stål, 1859, which have not previously been studied. These species are Rhodnius colombiensis (Mejia, Galvão & Jurberg 1999), Rhodnius milesi (Carcavallo, Rocha, Galvão & Jurberg 2001) and Rhodnius stali (Lent, Jurberg & Galvão 1993). The results revealed that there are similarities in the exochorial architecture of optical microscopy and scanning electron microscopy; these include the predominance of hexagonal cells that are common to all Rhodnius species and variable degrees of lateral flattening, which is common not only to species of this genus, but also to the Rhodniini tribe. Differences in overall colour, the presence of a collar in R. milesi, a longitudinal bevel in R. stali and the precise length of R. colombiensis can be useful distinguishing features. As a result of this study, the key for egg identification proposed by Barata in 1981 can be updated.