162 resultados para Biomechanical Phenomena

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: The complexity and heterogeneity of human bone, as well as ethical issues, frequently hinder the development of clinical trials. The purpose of this in vitro study was to determine the modulus of elasticity of a polyurethane isotropic experimental model via tension tests, comparing the results to those reported in the literature for mandibular bone, in order to validate the use of such a model in lieu of mandibular bone in biomechanical studies. MATERIAL AND METHODS: Forty-five polyurethane test specimens were divided into 3 groups of 15 specimens each, according to the ratio (A/B) of polyurethane reagents (PU-1: 1/0.5, PU-2: 1/1, PU-3: 1/1.5). RESULTS: Tension tests were performed in each experimental group and the modulus of elasticity values found were 192.98 MPa (SD=57.20) for PU-1, 347.90 MPa (SD=109.54) for PU-2 and 304.64 MPa (SD=25.48) for PU-3. CONCLUSION: The concentration of choice for building the experimental model was 1/1.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: The complexity and heterogeneity of human bone, as well as ethical issues, most always hinder the performance of clinical trials. Thus, in vitro studies become an important source of information for the understanding of biomechanical events on implant-supported prostheses, although study results cannot be considered reliable unless validation studies are conducted. The purpose of this work was to validate an artificial experimental model based on its modulus of elasticity, to simulate the performance of human bone in vivo in biomechanical studies of implant-supported prostheses. MATERIAL AND METHODS: In this study, fast-curing polyurethane (F16 polyurethane, Axson) was used to build 40 specimens that were divided into five groups. The following reagent ratios (part A/part B) were used: Group A (0.5/1.0), Group B (0.8/1.0), Group C (1.0/1.0), Group D (1.2/1.0), and Group E (1.5/1.0). A universal testing machine (Kratos model K - 2000 MP) was used to measure modulus of elasticity values by compression. RESULTS: Mean modulus of elasticity values were: Group A - 389.72 MPa, Group B - 529.19 MPa, Group C - 571.11 MPa, Group D - 470.35 MPa, Group E - 437.36 MPa. CONCLUSION: The best mechanical characteristics and modulus of elasticity value comparable to that of human trabecular bone were obtained when A/B ratio was 1:1.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: The ability to predict and understand which biomechanical properties of the cornea are responsible for the stability or progression of keratoconus may be an important clinical and surgical tool for the eye-care professional. We have developed a finite element model of the cornea, that tries to predicts keratoconus-like behavior and its evolution based on material properties of the corneal tissue. METHODS: Corneal material properties were modeled using bibliographic data and corneal topography was based on literature values from a schematic eye model. Commercial software was used to simulate mechanical and surface properties when the cornea was subject to different local parameters, such as elasticity. RESULTS: The simulation has shown that, depending on the corneal initial surface shape, changes in local material properties and also different intraocular pressures values induce a localized protuberance and increase in curvature when compared to the remaining portion of the cornea. CONCLUSIONS: This technique provides a quantitative and accurate approach to the problem of understanding the biomechanical nature of keratoconus. The implemented model has shown that changes in local material properties of the cornea and intraocular pressure are intrinsically related to keratoconus pathology and its shape/curvature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: To analyze the effects of low-level laser therapy (LLLT), 670 nm, with doses of 4 and 7 J/cm(2), on the repair of surgical wounds covered by occlusive dressings. Background Data: The effect of LLLT on the healing process of covered wounds is not well defined. Materials and Methods: For the histologic analysis with HE staining, 50 male Wistar rats were submitted to surgical incisions and divided into 10 groups (n=5): control; stimulated with 4 and 7 J/cm(2) daily, for 7 and 14 days, with or without occlusion. Reepithelization and the number of leukocytes, fibroblasts, and fibrocytes were obtained with an image processor. For the biomechanical analysis, 25 rats were submitted to a surgical incision and divided into five groups (n=5): treated for 14 days with and without occlusive dressing, and the sham group. Samples of the lesions were collected and submitted to the tensile test. One-way analysis of variance was performed, followed by post hoc analysis. A Tukey test was used on the biomechanical data, and the Tamhane test on the histologic data. A significance level of 5% was chosen (p <= 0.05). Results: The 4 and 7J/cm(2) laser with and without occlusive dressing did not alter significantly the reepithelization rate of the wounds. The 7 J/cm(2) laser reduced the number of leukocytes significantly. The number of fibroblasts was higher in the groups treated with laser for 7 days, and was significant in the covered 4 J/cm(2) laser group. Conclusions: Greater interference of the laser-treatment procedure was noted with 7 days of stimulation, and the occlusive dressing did not alter its biostimulatory effects.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work we investigate the influence of the adsorption of ions on the impedance spectroscopy of an electrolytic cell. We consider that the positive and negative ions present in a dielectric liquid are adsorbed in the electrode surfaces with different adsorption energies. This difference in adsorption energies causes an additional plateaux in the limit of the low-frequency range of the real part of the impedance Z. In the same frequency range, a second minimum in the imaginary part of Z is predicted. The theory is illustrated with measurements of the impedance of an electrolytic solution in the frequency range from 10(-2) Hz to 1 KHz. A comparison between the present model and others from the literature to describe the experimental results is also made.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study, we examined Spatial-temporal gait stride parameters, lower extremity joint angles, ground reaction forces (GRF) components, and electromyographic activation patterns of 10 healthy elderly individuals (70 +/- 6 years) walking in water and on land and compared them to a reference group of 10 younger adults (29 +/- 16 years). They all walked at self-selected comfortable speeds both on land and while immersed in water at the Xiphoid process level. Concerning the elderly individuals, the main significant differences observed were that they presented shorter stride length, slower speed, lower GRF values, higher horizontal impulses, smaller knee range of motion, lower ankle dorsiflexion, and more knee flexion at the stride`s initial contact in water than on land. Concerning the comparison between elderly individuals and adults, elderly individuals walked significantly slower on land than adults but both groups presented the same speed walking in water. In water, elderly individuals presented significantly shorter stride length, lower stride duration, and higher stance period duration than younger adults. That is, elderly individuals` adaptations to walking in water differ from those in the younger age group. This fact should be considered when prescribing rehabilitation or fitness programs for these populations. (C) 2006 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study reports the effects of dietary iron (Fe) deficiency and recovery on bone mineral composition and strength in anemic rats submitted to a hemoglobin (Hb) repletion assay. Weanling male Wistar rats were fed a low-Fe diet (12 mg/kg) for 15 days followed by 2 weeks of Fe repletion with diets providing 35 mg Fe/kg as either ferrous sulfate (n = 8) or ferric pyrophosphate (FP; n = 12). At final day of each period (depletion and repletion), Fe-adequate animals were also euthanized. Iron status (blood Hb, Hb Fe pool, Hb regeneration efficiency), tibia mineral concentrations (Ca, Mg, Fe, Cu, and Zn) and biomechanical properties were evaluated. Iron-deficient rats had lower tibia Fe and Mg levels and bone strength when compared to controls. Yield load and resilience were positively related to tibia Mg levels (r = 0.47, P = 0.02 and r = 0.56, P = 0.004, respectively). Iron repletion did not recover tibia Mg concentrations impaired by Fe deficiency. Moreover, bone elastic properties were negatively affected by FP consumption. In conclusion, bone mineral composition and strength were affected by Fe deficiency, whereas dietary Fe source influenced tibia Mg and resistance in the period during which rats were recovering from anemia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Feeding mineral-deficient diets enhances absorptive efficiency as an attempt of the body to compensate for the lack of an essential nutrient. Under certain circumstances, it does not succeed, and nutritional deficiency is produced Our hypothesis was that mulin-type fructans (ITF), which arc known to affect mineral absorption, could increase Ca and Fe bioavailability in Ca- and Fe-deficient rats. Male Wistar rats (n = 48, 4 weeks old) were assigned to I of 8 groups derived from 2 x 2 x 2 factorial design with 2 levels of added Fe (0 and 35 mg/kg), Ca (0 and 5 g/kg), and ITF (0 and 100 g/kg) for 33 days. The Fe status (hemoglobin, serum Fe, total Fe-binding capacity, transferrin saturation, liver minerals) was evaluated. Tibia minerals (Ca, Mg, and Zn), bone strength, and histomorphometry were determined In nondeficient rats, ITF supplementation did not affect Fe status or organ minerals, with the exception of tibia Mg Moreover, ITF improved bone resilience and led to a reduction in eroded surface per body surface and number of osteoclasts per area In Ca-deficient rats, ITF increased liver (Fe and Zn) and tibia (Zn) mineral levels but impaired tibia Mg, yield load, and resilience. In conclusion, ITF worsened the tibia Mg levels and elastic properties when supplemented in Ca-deficient diets In contrast, although bone Ca was not affected in nondeficient rats under the present experimental conditions, bone quality improved, as demonstrated by a moderate reduction in femur osteoclast resorption and significant increases in tibia Mg content and elasticity. (C) 2009 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To compare changes in corneal hysteresis (CH) and the corneal resistance factor (CRF) in myopic and hyperopic laser in situ keratomileusis (LASIK) and evaluate their relationship to the number of photoablative pulses delivered, a surrogate for ablation volume. SETTING: Cleveland Clinic Cole Eye Institute, Cleveland, Ohio, USA. METHODS: Preoperative and 1-week postoperative Ocular Response Analyzer measurements in eyes that had femtosecond-assisted LASIK were studied retrospectively. Changes in CH and CRF were compared and tested for correlation with the number of excimer laser pulses. RESULTS: Thirteen myopic eyes and 11 hyperopic eyes were evaluated. Preoperative corneal thickness, CH, CRF, programmed correction magnitude, flap thickness, and total number of fixed spotsize photoablative pulses were similar in the 2 groups (P>.1). Decreases in CH and CRF were greater after myopic LASIK than after hyperopic LASIK (P<.005), and changes in CRF were correlated with the number of excimer laser pulses in the myopic group only (r = -0.63, P = .02). Regardless of ablation profile, changes in CH were more strongly correlated with preoperative CH values than with attempted ablation volume. CONCLUSIONS: With comparable flap thickness and attempted ablation volumes, myopic photoablation profiles were associated with greater decreases in CRF and CH than hyperopic profiles. Results indicate that preoperative corneal biomechanical status, ablation volume, and the spatial distribution of ablation are important factors that affect corneal resistance and viscous dissipative properties differently. Preferential tissue removal in the natively thicker paracentral cornea in hyperopia may partially account for the rarity of ectasia after hyperopic LASIK.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aimed to investigate bone responses to a novel bioactive fully crystallized glass-ceramic of the quaternary system P(2)O(5)-Na(2)O-CaO-SiO(2) (Biosilicates (R)). Although a previous study demonstrated positive effects of Biosilicate (R) on in vitro bone-like matrix formation, its in vivo effect was not studied yet. Male Wistar rats (n = 40) with tibial defects were used. Four experimental groups were designed to compare this novel biomaterial with a gold standard bioactive material (Bioglass (R) 45S5), unfilled defects and intact controls. A three-point bending test was performed 20 days after the surgical procedure, as well as the histomorphometric analysis in two regions of interest: cortical bone and medullary canal where the particulate biomaterial was implanted. The biomechanical test revealed a significant increase in the maximum load at failure and stiffness in the Biosilicate group (R) (vs. control defects), whose values were similar to uninjured bones. There were no differences in the cortical bone parameters in groups with bone defects, but a great deal of woven bone was present surrounding Biosilicate (R) and Bioglass (R) 45S5 particulate. Although both bioactive materials supported significant higher bone formation; Biosilicate (R) was superior to Bioglass (R) 45S5 in some histomorphometric parameters (bone volume and number of osteoblasts). Regarding bone resorption, Biosilicate (R) group showed significant higher number of osteoclasts per unit of tissue area than defect and intact controls, despite of the non-significant difference in the osteoclastic surface as percentage of bone surface. This study reveals that the fully crystallized Biosilicate (R) has good bone-forming and bone-bonding properties. (C) 2011 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 978: 139-147, 2011.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To test the hypothesis that ruptured abdominal aortic aneurysms (AAA) are globally weaker than unruptured ones. Methods: Four ruptured and seven unruptured AAA specimens were harvested whole from fresh cadavers during autopsies performed over an 18-month period. Multiple regionally distributed longitudinally oriented rectangular strips were cut from each AAA specimen for a total of 77 specimen strips. Strips were subjected to uniaxial extension until failure. Sections from approximately the strongest and weakest specimen strips were studied histologically and histochemically. From the load-extension data, failure tension, failure stress and failure strain were calculated. Rupture site characteristics such as location, arc length of rupture and orientation of rupture were also documented. Results: The failure tension, a measure of the tissue mechanical caliber was remarkably similar between ruptured and unruptured AAA (group mean +/- standard deviation of within-subject means: 11.2 +/- 2.3 versus 11.6 +/- 3.6 N/cin; p=0.866 by mixed model ANOVA). In post-hoc analysis, there was little difference between the groups in other measures of tissue mechanical caliber as well such as failure stress (95 +/- 28 versus 98 +/- 23 N/cm(2); p=0.870), failure strain (0.39 +/- 0.09 versus 0.36 +/- 0.09; p=0.705), wall thickness (1.7 +/- 0.4 versus 1.5 +/- 0.4 mm; p=0.470), and % coverage of collagen within tissue cross section (49.6 +/- 12.9% versus 60.8 +/- 9.6%; p=0.133). In the four ruptured AAA, primary rupture sites were on the lateral quadrants (two on left; one on left-posterior; one on right). Remarkably, all rupture lines had a longitudinal orientation and ranged from 1 to 6 cm in length. Conclusion: The findings are not consistent with the hypothesis that ruptured aortic aneurysms are globally weaker than unruptured ones. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The use of synthetic mesh for abdominal wall closure after removal of the rectus abdominis is established but not standardised. This study compares two forms of mesh fixation: a simple suture, which fixes the mesh to the edges of the defect on the anterior rectus abdominis fascia; and total fixation, which incorporates the fasciae of the internal oblique, external oblique and transverse muscles in the suture, anchoring the mesh in the position of the removed muscle. Method: A total of 16 fresh cadavers were dissected. Two sutures were compared: simple and total. Three different sites were analysed: 5 cm above, 5 cm below and at the level of the umbilicus. The two sutures compared were tested in each region using a standardised technique. All sutures were performed with nylon 0, perpendicular to the linea alba. Each suture was secured to a dynamometer, which was pulled perpendicularly towards the midline until the rupture of the aponeurosis. `Rupture resistance` was measured in kilogram force. The mean among the groups was compared using the paired Student`s t-test to a significance level of 1% (p < 0.01). Results: The mean rupture resistance of the total suture was 160% higher than that of the simple suture. Conclusion: The total suture includes the external oblique, internal oblique and transverse fasciae, which are multi-directional, and creates a much higher resistance when compared with the simple suture. Total suture may reduce the incidence of bulging and hernias of the abdominal wall after harvesting the rectus abdominis muscle, but comparative clinical studies are necessary. (C) 2010 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: Acrylic cement has been used for years on orthopaedic surgeries, especially on knee arthroplasties, deserving special attention when added to antibiotics (for treatment of deep bone infections) or stains (to facilitate its removal). The present study was conducted in order to evaluate potential mechanical differences between the orthopaedic cement itself and when this is added to antibiotic and/or stains. Methods: Surgical bone cement Simplex@P Stryker, vancomycin and methylene blue were used, and the mixtures were submitted to physical and mechanical tests according the ABNT NBR ISO 5833 rule. The parameters studied here were: time for mass formation, intrusion capability, resistance to compression, resistance to flexion and maximum temperature reached by the mixtures. Results: The evaluated mixtures were approved as to mass formation, maximum temperature, intrusion capability and resistance to compression. Only the one containing pure cement was approved on the flexion essay. Conclusion: The addition of vancomycin and/or methylene blue to Surgical Simplex@P Stryker bone cement reduces its resistance to flexion, being unacceptable by the ABNT NBR ISO 5833 rule.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Although obsessions and compulsions comprise the main features of obsessive-compulsive disorder (OCD), many patients report that their compulsions are preceded by a sense of ""incompleteness"" or other unpleasant feelings such as premonitory urges or a need perform action`s until feeling ""just right."" These manifestations have been characterized as Sensory Phenomena (SP). The current study presents initial psychometric data for a new scale designed to measure SP. Methods: Seventy-six adult OCD subjects were probed twice. Patients were assessed with an open clinical interview (considered as the ""gold standard"") and with the following standardized instruments: Structured Clinical Interview for Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition Axis I Disorders, Yale-Brown Obsessive-Compulsive Scale, Dimensional Yale-Brown Obsessive-Compulsive Scale, Yale Global Tic Severity Scale, Beck Anxiety Inventory, and Beck Depression Inventory. Results: SP were present in 51 OCD patients (67.1%). Tics were present in 16 (21.1%) of the overall sample. The presence of SP was significantly higher in early-onset OCD patients. There were no significant differences in the presence of SP according to comorbidity with tics or gender. The comparison between the results from the open clinical interviews and the University of Sao Paulo Sensory Phenomena Scale (USP-SPS) showed an excellent concordance between them, with no significant differences between interviewers. The inter-rater reliability between the expert raters for the USP-SPS was high, with K=.92. The Pearson correlation coefficient between the SP severity scores given by the two raters was .89. Conclusion: Preliminary results suggest that the USP-SPS is a valid and reliable instrument for assessing the presence and severity of SP in OCD subjects. CNS Spectr. 2009;14(6):315-323

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: A variety of subjective experiences have been reported to be associated with the symptom expression of obsessive-compulsive disorder (OCD) and Tourette syndrome (TS). First described in TS patients, these subjective experiences have been defined in different ways. There is no consensus in the literature on how to best define subjective experiences. This lack of consensus may hinder the understanding of study results and prevents the possibility of including them in the search for etiological factors associated with OCD and TS. Methods: The objective of this article was to review the descriptions of subjective experiences in the English-language literature from 1980-2007. This meta-analytic review was carried out using the English-language literature from 1980-2007 available on MEDLINE, PsycINFO, and the Cochrane Library databases using the following search terms: premonitory urges, sensory tics, ""just-right"" perceptions, sensory phenomena, sensory experiences, incompleteness, ""not just-right"" phenomena, obsessive-compulsive disorder and TS, including OCD and/or TS, in all combination searches. We also searched for the references cited in each article previously found that referred to the aforementioned terms. Thirty-one articles were included in the study. Results: Subjective experiences, in particular, the sensory phenomena, were important phenotypic variables in the characterization of the tic-related OCD subtype and were more frequent in the early-onset OCD subtype. There is a paucity of studies using structured interviews to assess sensory phenomena, their epidemiology and the etiological mechanisms associated with sensory phenomena. Conclusion: The current review provides some evidence that sensory phenomena can be useful to identify more homogenous subgroups of OCD and TS patients and should be included as important phenotypic variables in future clinical, genetic, neuroimaging, and treatment-response studies.