29 resultados para Aquiferos - Contaminação
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)
Resumo:
The vinasse, awaste produced in the proportion of 13 liters for each liter of alcohol. It has a high potential of polluting groundwater and superficial water resources, changes the soil behaviour and can also develop sanilization problems. This work aims to evaluate the efficiency of the DC-resistivity method in detecting and mapping anomalies caused by inappropriate disposal of vinasse in an inactive infiltration tank located at Sepé-Tiarajú settlement of landless agricultural laborers in the Ribeirão Preto region. Besides, as secondary goals, this work aims to characterize the type of anomaly residue as well as to diagnose its influence inside and outside of the limits of the tank. Eleven electrical resistivity tomography profiles were carried out with the dipole-dipole array, 10m of dipoles length and 5 leveis of investigation The geophysical survey enabled us to conclude that the DC-resistivity method is appropriate for mapping the contamination plume caused by intense vinasse disposal and its influence. It enabled also to conclude that the contamination exceeds the tank limits. The vinasse influence can be characterized by low resistivity values between 10 Ohm.m and 90 Ohm.m and its behavior can be compared with the one of the chorume, which is also conductive.
Resumo:
Three approaches were applied to evaluate metal contamination in 41 sediment samples from the Santos - São Vicente Estuarine System: normalization to Al, statistical analysis and sediment quality guidelines (SQGs). The results showed increases in the concentrations of Zn, Ni, Pb, Cd, Cr and Hg, which seemed to be associated with human activities. The levels of Al, Fe and Co probably were associated with crustal material or natural weathering processes. About 45% of the samples presented concentrations exceeding TEL-ERL, levels occasionally associated with adverse biological effects. Four of these samples presented concentrations above PEL-ERM, levels frequently associated with adverse biological effects.
Resumo:
Organic markers, such as sterols and ketones, were used to assess sewage contamination in sediments from the Santos Bay, SP, and its continental shelf. These compounds were analyzed by GC/FID after soxhlet extraction, clean up and derivatization. The concentration of coprostanol and ratios between selected sterols were used to evaluate fecal contamination. The stations located in the mid-western part of the Santos Bay presented organic matter from sewage due to the input of fecal material from the city of Santos by submarine sewage outfall. Stations located at the continental shelf did not present fecal contamination. Coprostanol levels in sewage outfall stations were higher in comparison to other Brazilian coastal areas, except Guanabara Bay/RJ, and could be related to the fraction of the population without sewage treatment.
Resumo:
Este trabalho teve por objetivo monitorar a qualidade microbiológica e identificar fatores de interferência na contaminação da água de consumo de creches de um município da região oeste de São Paulo. Colheram -se 24 amostras de água tratada em 24 pontos de 11 creches, no centro e periferia de um município da região oeste de São Paulo, durante junho e julho de 2005. De cada amostra pesquisaram-se coliformes totais e Escherichia Coli. Verificou-se que nenhuma das amostras indicou presença de Escherichia Coli, nem coliformes totais. Setenta e três por cento das creches possuíam filtros de água; 64%, utilizavam água dos refeitórios para dessedentação e água das cozinhas no preparo das refeições, mamadeiras, hidratação, lavagem e desinfecção de vegetais, higiene do ambiente, utensílios e equipamentos; apenas 27% das creches transportavam água dos refeitórios e de outras áreas para a cozinha para o preparo das mamadeiras e hidratação e 9% das creches empregavam apenas água da cozinha, tanto para preparação de alimentos quanto dessedentação das crianças. Em 46% das creches a última limpeza e desinfecção dos reservatórios havia sido realizada há seis meses, em 18% há sete meses, em 9% há doze meses e 27% há mais de 12 meses. Com relação aos encanamentos, 73% das creches possuíam encanamentos de PVC (policloreto de vinila) e 27% de ferro. Concluiu-se que é fundamental o monitoramento periódico da potabilidade da água de uso nas creches; há necessidade de se implementar o procedimento de higienização dos reservatórios de água nas creches alvo deste estudo
Resumo:
This study evaluated in vitro the shear bond strength of a resin-based pit-and-fissure sealant (Fluroshield - F) associated with either an ethanol-based (Adper Single Bond 2 - SB) or an acetone-based (Prime & Bond - PB) adhesive system under conditions of oil contamination. Mesial and distal enamel surfaces from 30 sound third molars were randomly assigned to 2 groups (n=30): I - no oil contamination; II - oil contamination. Contamination (0.25 mL during 10 s) was performed after 37% phosphoric acid etching with an air/oil spray. The specimens were randomly assigned to subgroups, according to the bonding protocol adopted: subgroup A - F was applied to enamel without an intermediate bonding agent layer; In subgroups B and C, SB and PB, respectively, were applied, light-cured, and then F was applied and light-cured. Shear bond strength was tested at a crosshead speed of 0.5 mm/min in a universal testing machine. Means (± SD) in MPa were: IA-11.28 (±1.84); IIA-12.02 (±1.15); IB-9.73 (±2.38); IIB-9.62 (±2.29); IC-28.30 (±1.63); and IIC-25.50 (±1.91). It may be concluded that the oil contamination affected negatively the sealant bonding to enamel and the acetone-based adhesive system (PB) layer applied underneath the sealant was able to prevent its deleterious effects to adhesion.
Resumo:
A wide variety of opportunistic pathogens has been detected in the tubing supplying water to odontological equipment, in special in the biofilm lining of these tubes. Among these pathogens, Pseudomonas aeruginosa, one of the leading causes of nosocomial infections, is frequently found in water lines supplying dental units. In the present work, 160 samples of water, and 200 fomite samples from forty dental units were collected in the city of Barretos, State of São Paulo, Brazil and evaluated between January and July, 2005. Seventy-six P. aeruginosa strains, isolated from the dental environment (5 strains) and water system (71 strains), were tested for susceptibility to six antimicrobial drugs most frequently used against P. aeruginosa infections. Susceptibility to ciprofloxacin, followed by meropenem was the predominant profile. The need for effective means of reducing the microbial burden within dental unit water lines is emphasized, and the risk of exposure and cross-infection in dental practice, in special when caused by opportunistic pathogens like P. aeruginosa, are highlighted.
Resumo:
The esthetics and functional integrity of the periodontal tissue may be compromised by dental loss. Immediate implants became a viable option to maintain the periodontal architecture because of their anatomic compatibility with the dental socket and the possibility of eliminating local contamination. This article describes the procedure of immediate implant placement in the anterior maxilla replacing teeth with chronic periapical lesions, which were condemned due to endodontic lesions persisting after failed endodontic treatment and endodontic surgery, and discusses the relationship between the procedure and periapical lesions. Surgical removal of hopeless teeth 11, 12 and 21 was performed conservatively in such a way to preserve the anatomy and gingival esthetics. A second surgical access was gained at the apical level, allowing the debridement of the surgical chamber for elimination of the periapical lesion, visual orientation for setting of the implants and filling of the surgical chamber with xenogenous bovine bone graft. After this procedure, the bone chamber was covered with an absorbent membrane and the healing screws were positioned on the implants. Later, a provisional partial removable denture was installed and the implants were inserted after 6 months. After 3 years of rehabilitation, the implants present satisfactory functional and esthetic conditions, suggesting that immediate implant placement combined with guided bone regeneration may be indicated for replacing teeth lost due to chronic periapical lesions with endodontic failure history in the anterior maxilla.
Resumo:
This study evaluated in vitro the shear bond strength (SBS) of a resin-based pit-and-fissure sealant [Fluroshield (F), Dentsply/Caulk] associated with either an etch-and-rinse [Adper Single Bond 2 (SB), 3M/ESPE] or a self-etching adhesive system [Clearfil S3 Bond (S3), Kuraray Co., Ltd.] to saliva-contaminated enamel, comparing two curing protocols: individual light curing of the adhesive system and the sealant or simultaneous curing of both materials. Mesial and distal enamel surfaces from 45 sound third molars were randomly assigned to 6 groups (n=15), according to the bonding technique: I - F was applied to 37% phosphoric acid etched enamel. The other groups were contaminated with fresh human saliva (0.01 mL; 10 s) after acid etching: II - SB and F were light cured separately; III - SB and F were light cured together; IV - S3 and F were light cured separately; V - S3 and F were light cured simultaneously; VI - F was applied to saliva-contaminated, acid-etched enamel without an intermediate bonding agent layer. SBS was tested to failure in a universal testing machine at 0.5 mm/min. Data were analyzed by one-way ANOVA and Fisher's test (α=0.05).The debonded specimens were examined with a stereomicroscope to assess the failure modes. Three representative specimens from each group were observed under scanning electron microscopy for a qualitative analysis. Mean SBS in MPa were: I-12.28 (±4.29); II-8.57 (±3.19); III-7.97 (±2.16); IV-12.56 (±3.11); V-11.45 (±3.77); and VI-7.47 (±1.99). In conclusion, individual or simultaneous curing of the intermediate bonding agent layer and the resin sealant did not seem to affect bond strength to saliva-contaminated enamel. S3/F presented significantly higher SBS than the that of the groups treated with SB etch-and-rinse adhesive system and similar SBS to that of the control group, in which the sealant was applied under ideal dry, noncontaminated conditions.
Resumo:
PURPOSE: The aim of this study was to assess the contamination status of endodontic absorbent paper points from sterilized or not sterilized commercial packs, as well as paper points exposed to the dental office environment. METHODS: Twenty absorbent paper points were evaluated for contamination status packed under different conditions: commercial/sterilized pack, commercial/non-sterilized pack, exposed to the clinical environment, and intentionally contaminated (positive control). Contamination was determined qualitatively and quantitatively by aerobiosis, capnophilic growth, and pour plate. The Petri dishes were analyzed with a colony counter, and the results were expressed as colony-forming units. The data were analyzed by Kruskal-Wallis test (α=0.05). RESULTS: No difference in colony-forming units was found among the groups of endodontic absorbent paper points. All groups were contaminated by fungi and bacteria. CONCLUSION: It can be concluded that the sterilization of absorbent endodontic paper points before clinical use should be recommended regardless of commercial presentation
Resumo:
A ocorrência de aflatoxina B1 (AFB1) em rações e aflatoxina M1 (AFM1) no leite cru foi avaliada em propriedades leiteiras situadas na região nordeste do Estado de São Paulo, Brasil, de outubro de 2005 a fevereiro de 2006. A análise de aflatoxinas foi efetuada utilizando-se colunas de imunoafinidade para purificação dos extratos, sendo a quantificação realizada através de cromatografia líquida de alta eficiência. A AFB1 foi detectada em 40% das rações em níveis de 1,0 a 19,5 μg.kg-1. A concentração de AFM1 em 36,7% de amostras de leite positivas variou de 0,010 a 0,645 μg.L-1. Somente uma amostra de leite estava acima do limite de tolerância adotado no Brasil (0,5 μg.L-1) para AFM1. Concluiu-se que as concentrações de aflatoxinas na ração e no leite foram relativamente baixas, embora a alta frequência das aflatoxinas nas amostras analisadas indique a necessidade de contínuo monitoramento a fim de prevenir a contaminação de ingredientes e rações destinadas ao gado leiteiro.
Resumo:
Ensaios de sondagem e caminhamento elétrico têm sido realizados globalmente na avaliação de uma grande variedade de problemas em exploração mineral e hidrogeologia, bem como na caracterização de locais com risco de contaminação. A despeito da utilidade de ensaios geoelétricos em estudos hidrogeológicos e na caracterização de depósitos de resíduos desativados, um problema na utilização de sondagens elétricas ocorre em conseqüência da falta de espaço para aquisição de dados nessas áreas. Em áreas urbanas, isto constitui uma limitação importante devido à existência de construções, o que muitas vezes interrompe o desenvolvimento de ensaios de campo com arranjos de comprimentos adequados. Embora investigações rasas tendam a ser eficazes em caracterização geoambiental, a estimativa de parâmetros-chave pode depender da investigação de porções mais profundas. Entretanto, uma profundidade de investigação ligeiramente maior é obtida pelo arranjo dipolo-dipolo em comparação aos arranjos Schlumberger e Wenner de mesmo comprimento. Essa característica do arranjo dipolo-dipolo pode ser observada em vários estudos, mas provavelmente devido à tradição e à relação sinal-ruído, a grande maioria das sondagens elétricas é feita com os arranjos Schlumberger e Wenner.O arranjo dipolo-dipolo é mais utilizado em ensaios 2D. Até onde se sabe, essa maior capacidade de investigação em profundidade do arranjo dipolo-dipolo 1D não foi explorada em estudos geoambientais e nem em estudos hidrogeológicos em áreas urbanas. Este trabalho apresenta resultados de ensaios de campo que ressaltam a utilidade de sondagens dipolo-dipolo na investigação de tais áreas.
Resumo:
O Parque Estadual Intervales (PEI) e sua Zona de Amortecimento (ZA), inseridos nos vales dos rios Ribeira de Iguape e Paranapanema, situam-se em domínios de rochas carbonáticas proterozóicas de grande interesse para a mineração, onde se verifica a formação de carste com ocorrência expressiva de cavernas. A caracterização do carste no PEI e ZA para o plano de manejo foi baseada em estudos geológicos e geomorfológicos que permitiram definir o grau de vulnerabilidade à contaminação do aquífero cárstico. As regiões de maior vulnerabilidade do carste no PEI e ZA são aquelas que permitem a introdução direta de contaminantes no aquífero e se caracterizam pela presença de feições cársticas tais como cavernas e sumidouros. Para as regiões onde a recarga ocorre exclusivamente por infiltração difusa e o escoamento superficial converge para rios de superfície, foi associado grau de vulnerabilidade intermediário. Considerando essa análise, foram identificadas áreas com maior potencial para impactos e feitas recomendações para a gestão do parque e sua zona de amortecimento.
Resumo:
OBJECTIVE: To analyze household risk factors associated with high lead levels in surface dental enamel. METHODS: A cross-sectional study was conducted with 160 Brazilian adolescents aged 14-18 years living in poor neighborhoods in the city of Bauru, southeastern Brazil, from August to December 2008. Body lead concentrations were assessed in surface dental enamel acid-etch microbiopsies. Dental enamel lead levels were measured by graphite furnace atomic absorption spectrometry and phosphorus levels were measured by inductively coupled plasma optical emission spectrometry. The parents answered a questionnaire about their children's potential early (05 years old) exposure to well-known lead sources. Logistic regression was used to identify associations between dental enamel lead levels and each environmental risk factor studied. Social and familial covariables were included in the models. RESULTS: The results suggest that the adolescents studied were exposed to lead sources during their first years of life. Risk factors associated with high dental enamel lead levels were living in or close to a contaminated area (OR = 4.49; 95% CI: 1.69;11.97); and member of the household worked in the manufacturing of paints, paint pigments, ceramics or batteries (OR = 3.43; 95% CI: 1.31;9.00). Home-based use of lead-glazed ceramics, low-quality pirated toys, anticorrosive paint on gates and/or sale of used car batteries (OR = 1.31; 95% CI: 0.56;3.03) and smoking (OR = 1.66; 95% CI: 0.52;5.28) were not found to be associated with high dental enamel lead levels. CONCLUSIONS: Surface dental enamel can be used as a marker of past environmental exposure to lead and lead concentrations detected are associated to well-known sources of lead contamination.
Resumo:
An alternative technique for the fabrication of disposable electrochemical microcells containing working, reference and auxiliary electrodes on a single device is reported. The procedure is based on thermal-transfer of toner masks onto CD-R (recordable compact discs) gold surfaces to define the layout of the electrodes (contour). In a subsequent step, the layout is manually painted with a permanent marker pen. The unprotected gold surface is conveniently etched (chemical corrosion) and the ink is then easily removed with ethanol, generating gold surfaces without contamination. The final and reproducible area of the electrodes is defined by heat transference of a second toner mask. Silver epoxy is deposited on one of the gold bands which is the satisfactorily used as reference electrode. These microcells were electrochemically characterized by cyclic, linear, and square wave voltammetry, and several electroactive species were used as model systems. The area reproducibility of the electrodes for different microcells was studied and a relative standard deviation better than 1,0% (n = 10) was obtained. Disposable electrochemical microcells were successfully used in analysis of liquid samples with volumes lower than 200 µL and good stability and reproducibility (RSD less than 2.0%) were achieved. These microcells were also evaluated for quantification of paracetamol and dipyrone in pharmaceutical formulations.
Resumo:
Hematological alterations in fish are considered a useful tool to evaluate pathological processes resulting from the exposure to environmental pollutants. The whitemouth croaker Micropogonias furnieri is a common species in estuarine areas and potentially exposed to many contaminants. In the present study, the hematological characteristics of fish collected at two sites in Baixada Santista (Santos Estuarine System - SES, a polluted site; and the Estuary of Itanhaém River - EIR, unpolluted site) del was analysed. The following blood descriptors were analyzed: number of Erythrocytes (Er), Hematocrit (Ht), Hemoglobin (Hb), Mean Corpuscular Volume (MCV) and Mean Corpuscular Hemoglobin concentration (MCHC). Fish from SES exhibited significant lower levels of Ht and increase on MCHC and Hb. Such differences are likely related to the different contamination levels found in these estuaries.