35 resultados para Aimed Movement

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)


Relevância:

30.00% 30.00%

Publicador:

Resumo:

This investigation aimed at assessing the extent to which memory from practice in a specific condition of target displacement modulates temporal errors and movement timing of interceptive movements. We compared two groups practicing with certainty of future target velocity either in unchanged target velocity or in target velocity decrease. Following practice, both experimental groups were probed in the situations of unchanged target velocity and target velocity decrease either under the context of certainty or uncertainty about target velocity. Results from practice showed similar improvement of temporal accuracy between groups, revealing that target velocity decrease did not disturb temporal movement organization when fully predictable. Analysis of temporal errors in the probing trials indicated that both groups had higher timing accuracy in velocity decrease in comparison with unchanged velocity. Effect of practice was detected by increased temporal accuracy of the velocity decrease group in situations of decreased velocity; a trend consistent with the expected effect of practice was observed for temporal errors in the unchanged velocity group and in movement initiation at a descriptive level. An additional point of theoretical interest was the fast adaptation in both groups to a target velocity pattern different from that practiced. These points are discussed under the perspective of integration of vision and motor control by means of an internal forward model of external motion.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

During orthodontic tooth movement, there is local production of chemokines and an influx of leukocytes into the periodontium. CCL5 plays an important role in osteoclast recruitment and activation. This study aimed to investigate whether the CCR5-receptor influences these events and, consequently, orthodontic tooth movement. An orthodontic appliance was placed in wild-type mice (WT) and CCR5-deficient mice (CCR5(-/-)). The expression of mediators involved in bone remodeling was evaluated in periodontal tissues by Real-time PCR. The number of TRAP-positive osteoclasts and the expression of cathepsin K, RANKL, and MMP13 were significantly higher in CCR5(-/-). Meanwhile, the expression of two osteoblastic differentiation markers, RUNX2 and osteocalcin, and that of bone resorption regulators, IL-10 and OPG, were lower in CCR5(-/-). Analysis of the data also showed that CCR5(-/-) exhibited a greater amount of tooth movement after 7 days of mechanical loading. The results suggested that CCR5 might be a down-regulator of alveolar bone resorption during orthodontic movement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUÇÃO: a tomografia computadorizada (TC) permite a visualização do osso alveolar que recobre os dentes por vestibular e lingual. OBJETIVO: o propósito deste estudo foi expor e discutir as implicações da morfologia do osso alveolar, visualizado por meio da TC, sobre o diagnóstico e plano de tratamento ortodôntico. MÉTODOS: foram descritas as evidências sobre a inter-relação entre características dentofaciais e a morfologia das tábuas ósseas vestibular e lingual, assim como evidências sobre a repercussão da movimentação ortodôntica sobre o nível e espessura dessas estruturas periodontais. RESULTADOS: pacientes adultos podem apresentar deiscências ósseas previamente ao tratamento ortodôntico, principalmente na região dos incisivos inferiores. Os pacientes com padrão de crescimento vertical parecem apresentar menor espessura das tábuas ósseas vestibular e lingual no nível do ápice dos dentes permanentes, comparados a pacientes com padrão de crescimento horizontal. O movimento dentário vestibulolingual descentraliza os dentes do rebordo alveolar e ocasiona deiscências ósseas. CONCLUSÃO: a morfologia do rebordo alveolar constitui um fator limitante para a movimentação dentária e deve ser considerada, de forma individual, na realização do plano de tratamento ortodôntico.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: esta pesquisa objetivou avaliar cefalometricamente as alterações dentoesqueléticas de jovens com Classe II dentária tratados com o distalizador Jones jig. METODOLOGIA: foram avaliados 30 pacientes, sendo 15 de cada gênero, com média de idades iniciais de 13,63 anos; brasileiros, naturais da cidade de Bauru/SP, caracterizados por má oclusão de Classe II, 1ª e 2ª divisões de Angle sem comprometimento esquelético. Os jovens foram tratados com aparelho Jones jig a fim de distalizar os molares superiores a uma relação molar de "super Classe I"; sendo que esse dispositivo permaneceu, em média, por 0,55 anos. Ao final da sobrecorreção, os molares distalizados receberam um botão de Nance e, como ancoragem extrabucal, o aparelho extrabucal (AEB) com tração média-alta, com o intuito de verticalizar e corrigir a angulação radicular dos molares distalizados. Foram realizadas telerradiografias em normal lateral inicial (T1) e pós-distalização (T2). As medidas cefalométricas foram submetidas ao teste t dependente de Student para avaliar as alterações de T1 para T2. RESULTADOS: com base nos resultados obtidos e a partir da metodologia empregada, observou-se alterações dentárias significativas, como a movimentação distal linear e angular, assim como a intrusão dos segundos e primeiros molares superiores no sentido vertical. Também se confirmou efeitos indesejáveis, como a perda de ancoragem refletida em mesialização, extrusão e angulação mesial dos segundos pré-molares, a protrusão dos incisivos superiores e o aumento do trespasse vertical e horizontal. Pode-se confirmar que certas movimentações dentárias promovem significativas alterações esqueléticas de estruturas localizadas à distância, ou seja, observou-se extrusão significativa dos segundos pré-molares superiores, o que resultou em rotação mandibular, aumento significativo da altura facial anteroinferior e protrusão do lábio inferior. CONCLUSÃO: pode-se concluir que o distalizador Jones jig promove, basicamente, alterações dentárias.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present work has aimed to determine the 16 US EPA priority PAH atmospheric particulate matter levels present in three sites around Salvador, Bahia: (i) Lapa bus station, strongly impacted by heavy-duty diesel vehicles; (ii) Aratu harbor, impacted by an intense movement of goods, and (iii) Bananeira village on Maré Island, a non vehicle-influenced site with activities such as handcraft work and fisheries. Results indicated that BbF (0.130-6.85 ng m-3) is the PAH with highest concentration in samples from Aratu harbor and Bananeira and CRY (0.075-6.85 ng m-3) presented higher concentrations at Lapa station. PAH sources from studied sites were mainly of anthropogenic origin such as gasoline-fueled light-duty vehicles and diesel-fueled heavy-duty vehicles, discharges in the port, diesel burning from ships, dust ressuspension, indoor soot from cooking, and coal and wood combustion for energy production.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A distrofia muscular de Duchenne (DMD) é uma alteração neuromuscular caracterizada por contínua necrose muscular e degeneração, com eventual fibrose e infiltração por tecido adiposo. O aumento progressivo da fibrose intersticial no músculo impede a migração das células miogênicas, necessárias para a formação muscular. O modelo canino constitui-se nas melhores fenocópias da doença em humanos, quando comparados com outros modelos animais com distrofia. O tratamento antifibrose de pacientes DMD, tendo como alvo os mediadores da citocina, TGF-beta, e o tratamento com antiinflamatórios, podem limitar a degeneração muscular e contribuir para a melhora do curso da doença. O presente estudo teve como objetivo observar os possíveis efeitos adversos na fisiologia renal, por meio de avaliação bioquímica sanguínea e da pressão arterial, verificando a viabilidade do uso do Losartan (um inibidor de TGF-beta) nos cães afetados pela distrofia muscular. Foram utilizados quatro cães adultos, sendo dois machos e duas fêmeas. Utilizou-se a dose de 50mg de Losartan, administrada via oral, uma vez ao dia. Os exames clínicos, bem como alterações na função renal, o nível do potássio sérico e a pressão arterial não evidenciaram reação adversa durante todo o período do experimento. O uso de Losartan, por um período de 9 semanas, mostrou-se como uma terapia segura para o tratamento antifibrótico em cães adultos, não afetando a função renal ou pressão arterial dos animais.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To evaluate the effects of local administration of epidermal growth factor (EGF) located within liposomes on recruitment of osteoclasts during mechanical force in rats. Materials and Methods: An orthodontic elastic band was inserted between the left upper first and second molars, to move mesially the first molar. Rats were randomly divided into 4 groups (n = 8): EGF (2 ng/mu L) located within liposomes (group 1), liposomes only (group 2), soluble EGF (2 ng/mu L; group 3), or vehicle alone (group 4). The solutions were injected into the region of the root furcation of the left first molar after elastic band insertion. Tooth movement was measured using a plaster model of the maxilla, and the number of osteoclasts recruited at the pressure side of the first molar was histologically evaluated. Results: Intergroup analysis showed that there was no significant difference between group 2 and group 4 (P >.05) and between group 1 and group 3 (P >.05). However, group 1 and group 3 exhibited greater differences in tooth movement than group 2 and group 4 (P <.05). On the other hand, group 1 showed greater tooth movement than groups 2 and 4 with statistical significance (P <.01). The increase in the number of osteoclasts in group 1 was significantly higher than in the other groups (P <.05). Conclusion: Exogenous EGF-liposome administration has an additive effect when compared with soluble EGF on the rate of osteoclast recruitment, producing faster bone resorption and tooth movement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Long-acting injectable antipsychotics may improve medication adherence, thereby improving overall treatment effectiveness. This study aimed to evaluate the effectiveness, safety, and tolerability of risperidone long-acting injection in schizophrenic patients switched from oral antipsychotic medication. Methods: In a 12-month, multicenter, open-label, noncomparative study, symptomatically stable patients on oral antipsychotic medication with poor treatment adherence during the previous 12 months received intramuscular injections of risperidone long-acting injection (25 mg starting dose) every 2 weeks. The primary endpoint was the change in Positive and Negative Syndrome Scale (PANSS) total score. Results: Of the 60 patients who were screened, 53 received at least one injection (safety population), and 51 provided at least one postbaseline assessment. Mean PANSS total scores improved significantly throughout the study and at endpoint. Significant improvements were also observed in Clinical Global Impression of Severity, Personal and Social Performance, and Drug Attitude Inventory scales. Risperidone long-acting injection was safe and well-tolerated. Severity of movement disorders on the Extrapyramidal Symptom Rating Scale was reduced significantly. The most frequently reported adverse events were insomnia (22.6%), increased prolactin (17.0%), and weight gain (13.2%). Conclusion: Risperidone long-acting injection was associated with significant symptomatic improvements in stable patients with schizophrenia following a switch from previous antipsychotic medications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To determine if the magnitude of the force used to induce incisor tooth movement promotes distinct activation in cells in the central amygdala (CEA) and lateral hypothalamus (LH) of rats. Also, the effect of morphine on Fos immunoreactivity (Fos-IR) was investigated in these nuclei. Materials and Methods: Adult male rats were anesthetized and divided into six groups: only anesthetized (control), without orthodontic appliance (OA), OA but without force, OA activated with 30g or 70g, OA with 70g in animals pretreated with morphine (2 mg/kg, intraperitoneal). Three hours after the onset of the experiment the rats were reanesthetized and perfused with 4% paraformaldehyde. The brains were removed and fixed, and sections containing CEA and LH were processed for Fos protein immunohistochemistry. Results: The results show that in the control group, the intramuscular injection of a ketamine/xylazine mixture did not induce Fos-IR cells in the CEA or in the LH. Again, the without force group showed a little Fos-IR. However, in the 70g group the Fos-IR was the biggest observed (P < .05, Tukey) in the CEA and LH compared with the other groups. In the 30g group, the Fos-IR did not differ from the control group, the without OA group, and the without force group. Furthermore, pretreatment with morphine in the 70g group reduced Fos-IR in these regions. Conclusions: Tooth movement promotes Fos-IR in the CEA and LH according to the magnitude of the force applied. (Angle Orthod. 2010;80:111-115.)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: To describe the microscopic pulpal reactions resulting from orthodontically induced tooth movement associated with low-level laser therapy (LLLT) in rats. Materials and Methods: Forty-five young male Wistar rats were randomly assigned to three groups. In group I (n = 20), the maxillary right first molars were submitted to orthodontic movement with placement of a coil spring. In group II (n = 20), the teeth were submitted to orthodontic movement plus LLLT at 4 seconds per point (buccal, palatal, and mesial) with a GaAlAs diode laser source (830 nm, 100 mW, 18 J/cm(2)). Group III (n = 5) served as a control (no orthodontic movement or LLLT). Groups I and 11 were divided into four subgroups according to the time elapsed between the start of tooth movement and sacrifice (12 hours, 24 hours, 3 days, and 7 days). Results: Up until the 3-day period, the specimens in group I presented a thicker odontoblastic layer, no cell-free zone of Weil, pulp core with differentiated mesenchymal and defense cells, and a high concentration of blood vessels. In group II, at the 12- and 24-hour time points, the odontoblastic layer was disorganized and the cell-free zone of Weil was absent, presenting undifferentiated cells, intensive vascularization with congested capillaries, and scarce defense cells in the cell-rich zone. In groups I and II, pulpal responses to the stimuli were more intense in the area underneath the region of application of the force or force/laser. Conclusions: The orthodontic-induced tooth movement and LLLT association showed reversible hyperemia as a tissue response to the stimulus. LLLT leads to a faster repair of the pulpal tissue due to orthodontic movement. (Angle Orthod. 2010;80:116-122.)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

More than 2 years after undergoing anterior cruciate ligament (ACL) reconstruction, women still present bilateral asymmetries during multijoint movement tasks. Given the well-known ACL-injury gender bias, the goal of this study was to investigate whether males also present such asymmetries more than 2 years after undergoing ACL reconstruction. This study involved 12 participants submitted to ACL reconstruction in the ACL group and 17 healthy participants in the control group. The mean postoperative period was 37 months. The participants executed bilateral countermovement jumps and load squat tasks. The kinematics and ground reaction forces on each lower limb and pelvis were recorded, and used to compute bilateral peak vertical ground reaction forces, peak knee and hip joint powers in the sagittal plane, and the ratio between these powers. For the jump task, the groups had the same performance in the jump height, but for the ACL group the peak knee joint power on the operated side was 13% lower than on the non-operated side (p = 0.02). For the squat task, the hip-knee joint power ratio on the operated side of the ACL group was 31% greater than on the non-operated side (p = 0.02). The ACL group presented a deficit in the operated knee that had its energy generation over time (joint power) partially substituted by the hip joint power of the same side. The fact that, even after more than 2 years following the ACL reconstruction and returning to regular activity, the ACL group still had neuromuscular asymmetries suggests a need for improvement in the ACL reconstruction surgery procedures and/or rehabilitation protocols.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Manual asymmetries were analyzed in 18- to 63-year-old right-handers in different motor tasks. This analysis aimed at describing the asymmetry profile for each task and assessing their stability across ages. For this purpose, performance of the right and left hands were analyzed in the following aspects: simple reaction time, rate of sequential finger movements, maximum grip force, accuracy in anticipatory timing, rate of repetitive tapping, and rate of drawing movements. In addition, stability of manual preference across ages was assessed through the Edinburgh inventory (Oldfield, 1971). The results indicated different profiles of manual asymmetry, with identification of three categories across tasks: symmetric performance (asymmetry indices close to zero), inconsistent asymmetry (asymmetry indices variable in magnitude and direction), and consistent asymmetry (asymmetry indices favoring a single hand). The different profiles observed in the young adults were stable across ages with two exceptions: decreased lateral asymmetry for maximum grip force and increased asymmetry for sequential drawing in older individuals. These results indicate that manual asymmetries are task specific. Such task specificity is interpreted to be the result of different sensorimotor requirements imposed by each motor task in association with motor experiences accumulated over the lifetime. Analysis of manual preference showed that strength of preference for the right hand was greater in older individuals. (C) 2008 Elsevier Masson Srl. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ide, BN, Leme, TCF, Lopes, CR, Moreira, A, Dechechi, CJ, Sarraipa, MF, da Mota, GR, Brenzikofer, R, and Macedo, DV. Time course of strength and power recovery after resistance training with different movement velocities. J Strength Cond Res 25(7): 2025-2033, 2011-The purpose of this study was to evaluate the time course of strength and power recovery after a single bout of strength training designed with fast and slow contraction velocities. Nineteen male subjects were randomly divided into 2 groups: the slow-velocity contraction (SV) group and the fast velocity contraction (FV) group. Resistance training protocols consisted of 5 sets of 12 repetition maximum (5 x 12RM) with 50 seconds of rest between sets and 2 minutes between exercises. Contraction velocity was controlled by the execution time for each repetition (SV-6 seconds to complete concentric and eccentric phases and for FV-1.5 seconds). Leg Press 45 degrees 1RM (LP 1RM), horizontal countermovement jump (HCMJ), and right thigh circumference (TC) were accessed in 6 distinct moments: base (1 week before exercise), 0 (immediately after exercises), 24, 48, 72, and 96 hours after exercise protocol. The SV and FV presented significant LP 1RM decrements at 0, and these were still evident 24-48 hours postexercise. The magnitude of decline was significantly (p<0.05) higher for FV. The SV and FV presented significant HCMJ decrements at 0, but only for FV were these still evident 24-72 hours postexercise. The SV and FV presented significant TC increments at 0, and these were still evident 24-48 hours postexercise for SV but for FV it continued up to 96 hours. The magnitude of increase was significantly (p<0.05) higher for FV. In conclusion, the fast contraction velocity protocol resulted in greater decreases in LP 1RM and HCMJ performance, when compared with slow velocity. The results lead us to interpret that this variable may exert direct influence on acute muscle strength and power generation capacity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Self controlling practice implies a process of decision making which suggests that the options in a self controlled practice condition could affect learners The number of task components with no fixed position in a movement sequence may affect the (Nay learners self control their practice A 200 cm coincident timing track with 90 light emitting diodes (LEDs)-the first and the last LEDs being the warning and the target lights respectively was set so that the apparent speed of the light along the track was 1 33 m/sec Participants were required to touch six sensors sequentially the last one coincidently with the lighting of the tar get light (timing task) Group 1 (n=55) had only one constraint and were instructed to touch the sensors in any order except for the last sensor which had to be the one positioned close to the target light Group 2 (n=53) had three constraints the first two and the last sensor to be touched Both groups practiced the task until timing error was less than 30 msec on three consecutive trials There were no statistically significant differences between groups in the number of trials needed to reach the performance criterion but (a) participants in Group 2 created fewer sequences corn pared to Group 1 and (b) were more likely to use the same sequence throughout the learning process The number of options for a movement sequence affected the way learners self-controlled their practice but had no effect on the amount of practice to reach criterion performance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Generally, quadriplegic individuals have difficulties performing object manipulation. Toward satisfactory manipulation, reach and grasp movements must be performed with voluntary control, and for that, grasp force feedback is essential. A hybrid system aiming at partial upper limb sensory-motor restoration for quadriplegics was built. Such device is composed of an elbow dynamic orthosis that provides elbow flexion/extension (range was approximately from 20 degrees to 120 degrees, and average angular speed was approximately 15 degrees/s) with forearm support, a wrist static orthosis and neuromuscular electrical stimulation for grasping generation, and a glove with force sensors that allows grasping force feedback. The glove presents two user interface modes: visual by light emitting diodes or audio emitted by buzzer. Voice control of the entire system (elbow dynamic orthosis and electrical stimulator) is performed by the patient. The movements provided by the hybrid system, combined with the scapular and shoulder movements performed by the patient, can aid quadriplegic individuals in tasks that involve reach and grasp movements.