2 resultados para ATROPA-BELLADONNA

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)


Relevância:

60.00% 60.00%

Publicador:

Resumo:

The availaibilty of chloroplast genome (cpDNA) sequences of Atropa belladonna, Nicotiana sylvestris, N tabacum, N tomentosiformis, Solanum bulbocastanum, S lycopersicum and S tuberosum, which are Solanaceae species, allowed us to analyze the organization of cpSSRs in their genic and intergenic regions In general, the number of cpSSRs in cpDNA ranged from 161 in S tuberosum to 226 in N tabacum, and the number of intergenic cpSSRs was higher than genic cpSSRs The mononucleotide repeats were the most frequent in studied species, but we also identified di-, tri-, tetra-, penta- and hexanucleotide repeats Multiple alignments of all cpSSRs sequence from Solanaceae species made the identification of nucleotide variability possible and the phylogeny was estimated by maximum parsimony Our study showed that the plastome database can be exploited for phylogenetic analyses and biotechnological approaches

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Many therapeutic agents are commercialized under their racemic form. The enantiomers can show differences in the pharmacokinetic and pharmacodynamic profile. The use of a pure enantiomer in pharmaceutical formulations may result in a better therapeutic index and fewer adverse effects. Atropine, an alkaloid of Atropa belladonna, is a racemic mixture of l-hyoscyamine and d-hyoscyamine. It is widely used to dilate the pupil. To quantify these enantiomers in ophthalmic solutions, an HPLC method was developed and validated using a Chiral AGP (R) column at 20 degrees C. The mobile phase consisted of a buffered phosphate solution (containing 10 mM 1-octanesulfonic acid sodium salt and 7.5 mM triethylamine, adjusted to pH 7.0 with orthophosphoric acid) and acetonitrile (99 + 1, v/v). The flow rate was 0.6 mL/min, with UV detection at 205 nm. In the concentration range of 14.0-26.0 mu g/mL, the method was found to be linear (r > 0.9999), accurate (with recovery of 100.1-100.5%), and precise (RSD system: <= 0.6%; RSD intraday: <= 1.1%; RSD interday: <= 0.9%). The method was specific, and the standard and sample solutions were stable for up to 72 h. The factorial design assures robustness with a variation of +/-10% in the mobile phase components and 2 degrees C of column temperature. The complete validation, including stress testing and factorial design, was studied and is presented in this research.