27 resultados para 810

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To evaluate the influence of 810-nm-diode laser irradiation, applied before root canal filling, on apical sealing ability of three different resin-based sealers (AH Plus, EndoRez, and RealSeal). Background: Lasers have been widely used in endodontics. The dentin wall changes caused by laser irradiation could improve the sealing ability of endodontic cements. Methods: Sixty single-rooted human teeth were divided into six groups, according to the endodontic sealer used and previous 810-nm-diode laser irradiation. The protocol for laser irradiation was 2.5W in a continuous wave, in scanning mode, with four irradiations per tooth. After sample preparation, they were analyzed according to apical leakage with silver nitrate impregnation. Results: The RealSeal sealer achieved minimum leakage rates (1.24 mm), with significant differences at the 1% level (Tukey's test, p < 0.01) from AH Plus (1.84 mm) in nonirradiated groups. When the laser was used, there were also significant differences at the 5% level (p < 0.05) between irradiated groups (1.31 and 1.78 mm, respectively). Conclusion: The 810-nm-diode laser irradiation did not promote significant differences in apical leakage.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To investigate the effect of therapeutic infrared class 3B laser irradiation on skin temperature in healthy participants of differing skin color, age, and gender. Background: Little is known about the potential thermal effects of Low Level Laser Therapy (LLLT) irradiation on human skin. Methods: Skin temperature was measured in 40 healthy volunteers with a thermographic camera at laser irradiated and control (non-irradiated) areas on the skin. Six irradiation doses (2-12 J) were delivered from a 200mW, 810nm laser and a 60mW, 904nm laser, respectively. Results: Thermal effects of therapeutic LLLT using doses recommended in the World Association for Laser Therapy (WALT) guidelines were insignificant; below 1.5 degrees C in light, medium, and dark skin. When higher irradiation doses were used, the 60mW, 904 nm laser produced significantly (p < 0.01) higher temperatures in dark skin (5.7, SD +/- 1.8 degrees C at 12 J) than in light skin, although no participants requested termination of LLLT. However, irradiation with a 200mW, 810nm laser induced three to six times more heat in dark skin than in the other skin color groups. Eight of 13 participants with dark skin asked for LLLT to be stopped because of uncomfortable heating. The maximal increase in skin temperature was 22.3 degrees C. Conclusions: The thermal effects of LLLT at doses recommended by WALT-guidelines for musculoskeletal and inflammatory conditions are negligible (< 1.5 degrees C) in light, medium, and dark skin. However, higher LLLT doses delivered with a strong 3B laser (200mW) are capable of increasing skin temperature significantly and these photothermal effects may exceed the thermal pain threshold for humans with dark skin color.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES: The purpose of this in vitro study was to evaluate misfit alterations at the implant/abutment interface of external and internal connection implant systems when subjected to cyclic loading. MATERIAL AND METHODS: Standard metal crowns were fabricated for 5 groups (n=10) of implant/abutment assemblies: Group 1, external hexagon implant and UCLA cast-on premachined abutment; Group 2, internal hexagon implant and premachined abutment; Group 3, internal octagon implant and prefabricated abutment; Group 4, external hexagon implant and UCLA cast-on premachined abutment; and Group 5, external hexagon implant and Ceraone abutment. For groups 1, 2, 3 and 5, the crowns were cemented on the abutments and in group 4 crowns were screwed directly on the implant. The specimens were subjected to 500,000 cycles at 19.1 Hz of frequency and non-axial load of 133 N in a MTS 810 machine. The vertical misfit (μm) at the implant/abutment interface was evaluated before (B) and after (A) application of the cyclic loading. Data were analyzed statistically by using two-away ANOVA and Tukey's post-hoc test (p<0.05). RESULTS: Before loading values showed no difference among groups 2 (4.33±3.13), 3 (4.79±3.43) and 5 (3.86±4.60); between groups 1 (12.88±6.43) and 4 (9.67±3.08), and among groups 2, 3 and 4. However, groups 1 and 4 were significantly different from groups 2, 3 and 5. After loading values of groups 1 (17.28±8.77) and 4 (17.78±10.99) were significantly different from those of groups 2 (4.83±4.50), 3 (8.07±4.31) and 5 (3.81±4.84). There was a significant increase in misfit values of groups 1, 3 and 4 after cyclic loading, but not for groups 2 and 5. CONCLUSIONS: The cyclic loading and type of implant/abutment connection may develop a role on the vertical misfit at the implant/abutment interface.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The possibility of using a graphite silicone-rubber composite electrode (GSR) in a differential pulse voltammetric(DPV) procedure for rutin (vitamin P) determination is described. Cyclic voltammograms of rutin presented a reversible pair of oxidation/reduction peaks respectively at 0.411 and 0.390 V (vs. SCE) at the GSR surface in Britton-Robinson(B-R) buffer solution pH 4.0. In DPV after optimization of conditions, an oxidation peak at 0.370 V (vs. SCE) was used to quantitative determination of rutin in B-R buffer solution pH 4.0. In this case a linear dynamic range of 5.0×10-8 to 50.0×10-8 mol L-1 was observed with a detection limit of 1.8×10-8 mol L-1 for the analyte. Recoveries from 94 to 113% were observed. The electrode surface was renewed by polishing after each determination, with a repeatability of 1.09 ± 0.06 µA (n = 10) peak current. Rutin was determined in a pharmaceutical formulation using the proposed electrode and the results agreed with those from an official method within 95% confidence level.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This article reports the use of the GsuI restriction enzyme to differentiate genotypes of Bovine Coronavirus (BCoV), based on an 18-nucleotide deletion of S1-coding region found in one of the two genotypes. It was concluded that this assay can be used as a rapid tool for BCoV genotypes differentiation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Parity rate, gonotrophic cycle length, and density of a Culex quinquefasciatus female population was estimated at the Parque Ecológico do Tietê (PET), São Paulo, Brazil. Adult Cx. quinquefasciatus females were collected from vegetation along the edges of a polluted drainage canal with the use of a battery-powered backpack aspirator from September to November 2005 and from February to April 2006. We examined 255 Cx. quinquefasciatus ovaries to establish the parity rate of 0.22 and determined the gonotrophic cycle length under laboratory conditions to be 3 and 4 days. From these data, we calculated the Cx. quinquefasciatus survival rate to be 0.60 and 0.68 per day. Density of the Cx. quinquefasciatus female (5.71 females per m2) was estimated based on a population size of 28,810 individuals divided by the sampled area of 5,040 m2. Results of all experiments indicate medium survivorship and high density of the Cx. quinquefasciatus female population. This species is epidemiologically relevant in the PET area and should be a target of the vector control program of São Paulo municipality

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objetivos: Avaliar a limitação de atividades e a participação social em indivíduos portadores de diabetes melito tipo 2. Métodos: Foram avaliados 79 pacientes, utilizando-se a escala SALSA (Screening of Activity Limitation and Safety Awareness - Triagem de Limitação de Atividade e Consciência de Risco), e a escala de Participação, que abrange oito das nove principais áreas da vida definidas na Classificação Internacional de Funcionalidade, Incapacidade e Saúde (CIF) da OMS. Resultados: A idade média dos participantes foi 61,6 ± 9,8 anos, sendo 55,7 por cento do sexo feminino, 68,4 por cento com companheiro(a), 32,9 por cento com renda até 3 salários mínimos e em 13,9 por cento o diabete influenciou na ocupação. O tempo médio de doença foi 10,3 ± 8,9 anos. Tratamento de 39,3 por cento dos participantes foi com insulina, 70,9 por cento com medicação oral, 51,9 por cento com dieta e 45,6 por cento com exercícios físicos. 48,1 por cento apresentavam alguma complicação da doença. A média de pontos SALSA foi 26,5 ± 11,6 e houve maior pontuação quando o tempo de doença foi superior a 10 anos. Com a evolução do diabetes, pode haver necessidade de insulinoterapia, aparecem as complicações, que podem interferir na ocupação. Estes fatores parecem contribuir para a limitação de atividade. A média de pontos na Escala de Participação foi 9,8±10,9, com maior pontuação quando os entrevistados consideraram sua saúde física alterada no último ano e faziam uso de insulina. Conclusões: A limitação de atividades no diabetes melito tipo 2 se associou ao tempo de doença, com possível contribuição de fatores que ocorrem com sua evolução. Auto-avaliação de saúde física alterada e insulinoterapia se associaram a restrição social

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work, a low alloy steel and a fabrication process were developed to produce U-Bolts for commercial vehicles. Thus, initially five types of no-heat treated steel were developed with different additions of chrome, nickel, and silicon to produce strain hardening effect during cold-forming processing of the U-Bolts, assuring the required mechanical properties. The new materials exhibited a fine perlite and ferrite microstructure due to aluminum and vanadium additions, well known as grain size refiners. The mechanical properties were evaluated in a servo-hydraulic test machine system-MTS 810 according to ASTM A370-03; E739 and E08m-00 standards. The microstructure and fractography analyses of the cold-formed steels were performed by using optical and scanning electronic microscope techniques. To evaluate the performance of the steels and the production process, fatigue tests were carried out under load control (tensile-tensile), R = 0.1 and f = 30 Hz. The Weibull statistic methodology was used for the analysis of the fatigue results. At the end of this work the 0.21% chrome content steel, Alloy 2, presented the best fatigue performance.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Context. Tight binaries discovered in young, nearby associations are ideal targets for providing dynamical mass measurements to test the physics of evolutionary models at young ages and very low masses. Aims. We report the binarity of TWA22 for the first time. We aim at monitoring the orbit of this young and tight system to determine its total dynamical mass using an accurate distance determination. We also intend to characterize the physical properties (luminosity, effective temperature, and surface gravity) of each component based on near-infrared photometric and spectroscopic observations. Methods. We used the adaptive-optics assisted imager NACO to resolve the components, to monitor the complete orbit and to obtain the relative near-infrared photometry of TWA22 AB. The adaptive-optics assisted integral field spectrometer SINFONI was also used to obtain medium-resolution (R(lambda) = 1500-2000) spectra in JHK bands. Comparison with empirical and synthetic librairies were necessary for deriving the spectral type, the effective temperature, and the surface gravity for each component of the system. Results. Based on an accurate trigonometric distance (17.5 +/- 0.2 pc) determination, we infer a total dynamical mass of 220 +/- 21 M(Jup) for the system. From the complete set of spectra, we find an effective temperature T(eff) = 2900(-200)(+200) K for TWA22A and T(eff) = 2900(-100)(+200) for TWA22 B and surface gravities between 4.0 and 5.5 dex. From our photometry and an M6 +/- 1 spectral type for both components, we find luminosities of log(L/L(circle dot)) = -2.11 +/- 0.13 dex and log(L/L(circle dot)) = -2.30 +/- 0.16 dex for TWA22 A and B, respectively. By comparing these parameters with evolutionary models, we question the age and the multiplicity of this system. We also discuss a possible underestimation of the mass predicted by evolutionary models for young stars close to the substellar boundary.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background Data and Objective: There is anecdotal evidence that low-level laser therapy (LLLT) may affect the development of muscular fatigue, minor muscle damage, and recovery after heavy exercises. Although manufacturers claim that cluster probes (LEDT) maybe more effective than single-diode lasers in clinical settings, there is a lack of head-to-head comparisons in controlled trials. This study was designed to compare the effect of single-diode LLLT and cluster LEDT before heavy exercise. Materials and Methods: This was a randomized, placebo-controlled, double-blind cross-over study. Young male volleyball players (n = 8) were enrolled and asked to perform three Wingate cycle tests after 4 x 30 sec LLLT or LEDT pretreatment of the rectus femoris muscle with either (1) an active LEDT cluster-probe (660/850 nm, 10/30mW), (2) a placebo cluster-probe with no output, and (3) a single-diode 810-nm 200-mW laser. Results: The active LEDT group had significantly decreased post-exercise creatine kinase (CK) levels (-18.88 +/- 41.48U/L), compared to the placebo cluster group (26.88 +/- 15.18U/L) (p < 0.05) and the active single-diode laser group (43.38 +/- 32.90U/L) (p<0.01). None of the pre-exercise LLLT or LEDT protocols enhanced performance on the Wingate tests or reduced post-exercise blood lactate levels. However, a non-significant tendency toward lower post-exercise blood lactate levels in the treated groups should be explored further. Conclusion: In this experimental set-up, only the active LEDT probe decreased post-exercise CK levels after the Wingate cycle test. Neither performance nor blood lactate levels were significantly affected by this protocol of pre-exercise LEDT or LLLT.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The confined flows in tubes with permeable surfaces arc associated to tangential filtration processes (microfiltration or ultrafiltration). The complexity of the phenomena do not allow for the development of exact analytical solutions, however, approximate solutions are of great interest for the calculation of the transmembrane outflow and estimate of the concentration, polarization phenomenon. In the present work, the generalized integral transform technique (GITT) was employed in solving the laminar and permanent flow in permeable tubes of Newtonian and incompressible fluid. The mathematical formulation employed the parabolic differential equation of chemical species conservation (convective-diffusive equation). The velocity profiles for the entrance region flow, which are found in the connective terms of the equation, were assessed by solutions obtained from literature. The velocity at the permeable wall was considered uniform, with the concentration at the tube wall regarded as variable with an axial position. A computational methodology using global error control was applied to determine the concentration in the wall and concentration boundary layer thickness. The results obtained for the local transmembrane flux and the concentration boundary layer thickness were compared against others in literature. (C) 2007 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mechanisms of leukocyte NADPH oxidase regulation remain actively investigated. We showed previously that vascular and macrophage oxidase complexes are regulated by the associated redox chaperone PDI. Here, we investigated the occurrence and possible underlying mechanisms of PDI-mediated regulation of neutrophil NADPH oxidase. In a semirecombinant cell-free system, PDI inhibitors scrRNase (100 mu g/mL) or bacitracin (1 mM) near totally suppressed superoxide generation. Exogenously incubated, oxidized PDI increased (by similar to 40%), whereas PDIred diminished (by similar to 60%) superoxide generation. No change occurred after incubation with PDI serine-mutated in all four redox cysteines. Moreover, a mimetic CxxC PDI inhibited superoxide production by similar to 70%. Thus, oxidized PDI supports, whereas reduced PDI down-regulates, intrinsic membrane NADPH oxidase complex activity. In whole neutrophils, immunoprecipitation and colocalization experiments demonstrated PDI association with membrane complex subunits and prominent thiol-mediated interaction with p47(phox) in the cytosol fraction. Upon PMA stimulation, PDI was mobilized from azurophilic granules to cytosol but did not further accumulate in membranes, contrarily to p47(phox). PDI-p47(phox) association in cytosol increased concomitantly to opposite redox switches of both proteins; there was marked reductive shift of cytosol PDI and maintainance of predominantly oxidized PDI in the membrane. Pulldown assays further indicated predominant association between PDIred and p47(phox) in cytosol. Incubation of purified PDI (> 80% reduced) and p47(phox) in vitro promoted their arachidonate-dependent association. Such PDI behavior is consistent with a novel cytosolic regulatory loop for oxidase complex (re) cycling. Altogether, PDI seems to exhibit a supportive effect on NADPH oxidase activity by acting as a redox-dependent enzyme complex organizer. J. Leukoc. Biol. 90: 799-810; 2011.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To evaluate the effect of maternal oral hydration on amniotic fluid index (AFI) in pregnancies with fetal gastroschisis. Methods: AFI was evaluated at 24-hour intervals, during 4 consecutive days, under a continuous maternal oral water hydration regimen, in singleton pregnancies with isolated fetal gastroschisis. Results: Nine pregnancies were examined at a mean gestational age of 31.6 weeks (+/-1.4) and mean maternal daily oral water intake was 3,437 (+/-810) ml. Mean AFI on days 0-3 were 13.2 (+/-2.9), 14.8 (+/-3.3), 14.5 (+/-3.1) and 14.8 (+/-2.6), respectively. AFI on day 0 was significantly lower compared to all the other 3 days (p = 0.01 and 0.02). Significant correlation was found in relative difference in AFI between day 0 and day 1 and gestational age (r = -0.67, p = 0.05) and the amount of water intake in the previous 24 h (r = 0.76, p = 0.02). Conclusion: Maternal oral water hydration significantly increases AFI in pregnancies with isolated fetal gastroschisis. Copyright (C) 2010 S. Karger AG, Basel

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: People with less education in Europe, Asia, and the United States are at higher risk of mortality associated with daily and longer-term air pollution exposure. We examined whether educational level modified associations between mortality and ambient particulate pollution (PM(10)) in Latin America, using several timescales. Methods: The study population included people who died during 1998-2002 in Mexico City, Mexico; Santiago, Chile; and Sao Paulo, Brazil. We fit city-specific robust Poisson regressions to daily deaths for nonexternal-cause mortality, and then stratified by age, sex, and educational attainment among adults older than age 21 years (none, some primary, some secondary, and high school degree or more). Predictor variables included a natural spline for temporal trend, linear PM(10) and apparent temperature at matching lags, and day-of-week indicators. We evaluated PM(10) for lags 0 and I day, and fit an unconstrained distributed lag model for cumulative 6-day effects. Results: The effects of a 10-mu g/m(3) increment in lag 1 PM(10) on all nonextemal-cause adult mortality were for Mexico City 0.39% (95% confidence interval = 0.131/-0.65%); Sao Paulo 1.04% (0.71%-1.38%); and for Santiago 0.61% (0.40%-0.83%. We found cumulative 6-day effects for adult mortality in Santiago (0.86% [0.48%-1.23%]) and Sao Paulo (1.38% [0.85%-1.91%]), but no consistent gradients by educational status. Conclusions: PM(10) had important short- and intermediate-term effects on mortality in these Latin American cities, but associations did not differ consistently by educational level.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: To analyze mortality rates of children with severe sepsis and septic shock in relation to time-sensitive fluid resuscitation and treatments received and to define barriers to the implementation of the American College of Critical Care Medicine/Pediatric Advanced Life Support guidelines in a pediatric intensive care unit in a developing country. Methods: Retrospective chart review and prospective analysis of septic shock treatment in a pediatric intensive care unit of a tertiary care teaching hospital. Ninety patients with severe sepsis or septic shock admitted between July 2002 and June 2003 were included in this study. Results: Of the 90 patients, 83% had septic shock and 17% had severe sepsis; 80 patients had preexisting severe chronic diseases. Patients with septic shock who received less than a 20-mL/kg dose of resuscitation fluid in the first hour of treatment had a mortality rate of 73%, whereas patients who received more than a 40-mL/kg dose in the first hour of treatment had a mortality rate of 33% (P < 0.05.) Patients treated less than 30 minutes after diagnosis of severe sepsis and septic shock had a significantly lower mortality rate (40%) than patients treated more than 60 Minutes after diagnosis (P < 0.05). Controlling for the risk of mortality, early fluid resuscitation was associated with a 3-fold reduction in the odds of death (odds ratio, 0.33; 95% confidence interval, 0.13-0.85). The most important barriers to achieve adequate severe sepsis and septic shock treatment were lack of adequate vascular access, lack of recognition of early shock, shortage of health care providers, and nonuse of goals and treatment protocols. Conclusions: The mortality rate was higher for children older than years, for those who received less than 40 mL/kg in the first hour, and for those whose treatment was not initiated in the first 30 Minutes after the diagnosis of septic shock. The acknowledgment of existing barriers to a timely fluid administration and the establishment of objectives to overcome these barriers may lead to a more successful implementation of the American College of Critical Care Medicine guidelines and reduced mortality rates for children with septic shock in the developing world.