62 resultados para 670500 Veterinary Pharmaceutical Products
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)
Resumo:
This paper describes the determination of ciclopirox olamine in pharmaceutical formulations using capillary electrophoresis with capacitively coupled contactless conductivity detection. In an alkaline medium, ciclopirox olamine is converted into an anionic species and its detection is possible in capillary electrophoresis with capacitively coupled contactless conductivity detection without an electroosmotic flow modifier, because it is a low-mobility species. A linear working range from 2.64 to 264 mu g/mL in sodium hydroxide electrolyte as well as low detection limit (0.39 mu g/mL) and a good repeatability (RSD = 3.4% for 264 mu g/mL ciclopirox solution (n = 10)) were achieved. It was also possible to determine olamine in its cationic form when acetic acid was used as the electrolyte solution. The results obtained include a linear range from 26.4 to 184.8 mu g/mL and a detection limit of 2.6 mu g/mL olamine. The proposed methods were applied to the analysis of commercial pharmaceutical products and the results were compared with the values indicated by the manufacturer as well as those obtained using a titrimetric method recommended by American Pharmacopoeia.
Resumo:
Baccharis dracunculifolia is the source of Brazilian green propolis (BGP). Considering the broad spectrum of biological activities attributed to green proplis, B. dracunculifolia has a great potential for the development of new cosmetic and pharmaceutical products. In this work, the cultivation of 10 different populations of native B. dracunculifolia had been undertaken aiming to determine the role of seasonality on its phenolic compounds. For this purpose, fruits of this plant were collected from populations of 10 different regions, and 100 individuals of each population were cultivated in an experimental area of 1800 m(2). With respect to cultivation, the yields of dry plant, essential oil and crude extract were measured monthly resulting in mean values of 399 +/- 80 g, 0.6 +/- 0.1% and 20 +/- 4%, respectively. The HPLC analysis allowed detecting seven phenolic compounds: caffeic acid, ferulic acid, aromadendrin-4'-methyl ether (AME), isosakuranetin, artepillin C, baccharin and 2-dimethyl-6-carboxyethenyl-2H-1-benzopyran acid, which were the major ones throughout the 1-year monthly analysis. Caffeic acid was detected in all cultivated populations with mean of 4.0%. AME displayed the wide variation in relation to other compounds showing means values of 0.65 +/- 0.13% at last quarter. Isosakuranetin and artepillin C showed increasing concentrations with values between 0% and 1.4% and 0% and 1.09%, respectively. The obtained results allow suggesting that the best time for harvesting this plant, in order to obtain good qualitative and quantitative results for these phenolic compounds, is between December and April.
Resumo:
Background: The effectiveness of a water/oil (w/o) microemulsion containing quercetin against ultraviolet B radiation (UVB) induced damage was recently demonstrated by our group. However, during the development of new pharmaceutical products, the evaluation of percutaneous absorption and in vivo effectiveness should be accompanied by evaluation of stability parameters as an integral part of the process. Objective: The aim was to investigate the stability of the final microemulsion formulation considering the temperature ranges of storage and application. Methods: The physical, chemical, and functional stability of this formulation under different conditions of storage during 12 months and the photostability of quercetin incorporated into this system over UVB exposure for 7 days were evaluated. Results: Although the results indicated a notable physical stability of the w/o microemulsions during the experimental period under all employed conditions, in both, the chemical and functional studies, a significant loss of quercetin content and antioxidant activity was found after 6 months of storage at 30 degrees C/70% relative humidity and after 2 months at 40 degrees C/70% relative humidity. The photostability study results demonstrated that the incorporation of quercetin into the w/o microemulsion maintained the previously demonstrated photostability of this flavonoid under forced exposure to UVB irradiation. Conclusion: Thus, this work demonstrates that special storage conditions (at 4 +/- 2 degrees C) are necessary to maintain the functionality of the w/o microemulsion containing quercetin and mainly emphasizes the importance of studying physical, chemical, and functional parameters at the same time during stability evaluation of active principles.
Resumo:
Flow injection analysis (FIA) using a carbon film sensor for amperometric detection was explored for ambroxol analysis in pharmaceutical formulations. The specially designed flow cell designed in the lab generated sharp and reproducible current peaks, with a wide linear dynamic range from 5 x 10(-7) to 3.5 x 10(-4) mol L-1, in 0.1 mol L-1 sulfuric acid electrolyte, as well as high sensitivity, 0.110 A mol(-1) L cm(-2) at the optimized flow rate. A detection limit of 7.6 x 10(-8) mol L-1 and a sampling frequency of 50 determinations per hour were achieved, employing injected volumes of 100 mu L and a flow rate of 2.0 mL min(-1). The repeatability, expressed as R.S.D. for successive and alternated injections of 6.0 x 10(-6) and 6.0 x 10(-5) mol L-1 ambroxol solutions, was 3.0 and 1.5%, respectively, without any noticeable memory effect between injections. The proposed method was applied to the analysis of ambroxol in pharmaceutical samples and the results obtained were compared with UV spectrophotometric and acid-base titrimetric methods. Good agreement between the results utilizing the three methods and the labeled values was achieved, corroborating the good performance of the proposed electrochemical methodology for ambroxol analysis. (C) 2008 Elsevier B.V. All rights reserved.
Resumo:
Flow injection analysis (FIA) with amperometric detection was employed for the quantification of N-acetylcysteine (NAC) in pharmaceutical formulations, utilizing an ordinary pyrolytic graphite (OPG) electrode modified with cobalt phthalocyanine (CoPc). Cyclic voltammetry was used in preliminary studies to establish the best conditions for NAC analysis. In FIA-amperometric experiments the OPG-CoPc electrode exhibited sharp and reproducible current peaks over a wide linear working range (5.0 x 10(-5)-1.0 x 10(-3) mol L(-1)) in 0.1 mol L(-1) NaOH solution. High sensitivity (130 mA mol(-1) cm(2)) and a low detection limit (9.0 x 10(-7) mol L(-1)) were achieved using the sensor. The repeatability (R.S.D.%) for 13 successive flow injections of a solution containing 5.0 x 10(-4) mol L(-1) NAC was 1.1%. The new procedure was applied in analyses of commercial pharmaceutical products and the results were in excellent agreement with those obtained using the official titrimetric method. The proposed amperometric method is highly suitable for quality control analyses of NAC in pharmaceuticals since it is rapid, precise and requires much less work than the recommended titrimetric method. (C) 2010 Elsevier B.V. All rights reserved.
Resumo:
This study evaluated whether the four gonadorelin products that are commercially available in the United States produce comparable ovulation responses in lactating cows. Dairy cows at 7 d after last gonadotropin-releasing hormone (GnRH) treatment of Ovsynch (Day 7), with a corpus luteum (CL) >= 15 mm and at least one follicle >= 10 mm, were evaluated for response to GnRH treatment. Selected cows were randomized to receive (100 mu g; im): (1) Cystorelin (n = 146): (2) Factrel (n = 132): (3) Fertagyl (n = 140); or (4) Ovacyst (n = 140). On Day 14, cows were examined for Ovulation by detection of an accessory CL. Circulating luteinizing hormone (LH) concentrations were also evaluated in some cows after treatment with 100 mu g (n = 10 per group) or 50 mu g (n = 5 per group) GnRH. Statistical analyses were performed with the procedures MIXED and GLIMMIX of the SAS program. Percentage of cows ovulating differed (P < 0.01) among groups, with that for Factrel being lower (55.3%) than that for Cystorelin (76.7%), Fertagyl (73.6%), or Ovacyst (85.0%), There was no effect of batch, parity, or follicle size on ovulation response. but increasing body condition score decreased Ovulation response. There was a much greater LH release in cows treated with 100 mu g than in those treated with 50 mu g, but there were no detectable differences among products in time to LH peak, peak LH concentration, or area under the LH curve and no treatment effects nor treatment by time interactions on circulating LH profile. Thus, ovulation response to Factrel on Day 7 of the cycle was lower than that for other commercial GnRH products, although a definitive mechanism for this difference between products was not demonstrated. (C) 2009 Elsevier Inc. All rights reserved.
Resumo:
A simple and fast capillary zone electrophoresis (CZE) method has been developed and validated for quantification of a non-nucleoside reverse transcriptase inhibitor (NNRTI) nevirapine, in pharmaceuticals. The analysis was optimized using 10 mmol L-1 sodium phosphate buffer pH 2.5, +25 kV applied voltage, hydrodynamic injection 0.5 psi for 5 s and direct UV detection at 200 µm. Diazepam (50.0 µg mL-1) was used as internal standard. Under these conditions, nevirapine was analyzed in approximately less than 2.5 min. The analytical curve presented a coefficient of correlation of 0.9994. Limits of detection and quantification were 1.4 µg mL-1 and 4.3 µg mL-1, respectively. Intra- and inter-day precision expressed as relative standard deviations were 1.4% and 1.3%, respectively and the mean recovery was 100.81%. The active pharmaceutical ingredient was subjected to hydrolysis (acid, basic and neutral) and oxidative stress conditions. No interference of degradation products and tablet excipients were observed. This method showed to be rapid, simple, precise, accurate and economical for determination of nevirapine in pharmaceuticals and it is suitable for routine quality control analysis since CE offers benefits in terms of quicker method development and significantly reduced operating costs.
Resumo:
The immunogenic properties of cysteine proteases obtained from excretory/secretory products (ES) of Haemonchus contortus were investigated with a fraction purified with a recombinant H. contortus cystatin affinity column. The enrichment of H. contortus ES for cysteine protease was confirmed with substrate SDS-PAGE gels since the cystatin-binding fraction activity was three times higher than total ES, despite representing only 3% of total ES. This activity was inhibited by a specific cysteine protease inhibitor (E64) and by recombinant cystatin. The one-dimensional profile of the cystatin-binding fraction displayed a single band with a molecular mass of 43 kDa. Mass spectrometry showed this to be AC-5, a cathepsin B-like cysteine protease which had not been identified in ES products of H. contortus before. The cystatin binding fraction was tested as an immunogen in lambs which were vaccinated three times (week 0, 2.5 and 5), challenged with 10 000 L3 H. contortus (week 6) before necropsy and compared to unvaccinated challenge controls and another group given total ES (n = 10 per group). The group vaccinated with cystatin-binding proteins showed 36% and 32% mean worm burden and eggs per gram of faeces (EPG) reductions, respectively, compared to the controls but total ES was almost without effect. After challenge the cystatin-binding proteins induced significantly higher local and systemic ES specific IgA and IgG responses.
Resumo:
A great deal of attention in the supply chain management literature is devoted to study material and demand information flows and their coordination. But in many situations, supply chains may convey information from different nature, they may be an important channel companies have to deliver knowledge, or specifically, technical information to the market. This paper studies the technical flow and highlights its particular requirements. Drawing upon a qualitative field research, it studies pharmaceutical companies, since those companies face a very specific challenge: consumers do not have discretion over their choices, ethical drugs must be prescribed by physicians to be bought and used by final consumers. Technical information flow is rich, and must be redundant and early delivered at multiple points. Thus, apart from the regular material channel where products and order information flow, those companies build a specialized information channel, developed to communicate to those who need it to create demand. Conclusions can be extended to supply chains where products and services are complex and decision makers must be clearly informed about technology-related information. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
We examined the correlation between results obtained from the in vivo Draize test for ocular irritation and in vitro results obtained from the sheep red blood cell (RBC) haemolytic assay, which assesses haemolysis and protein denaturation in erythrocytes, induced by cosmetic products. We sought to validate the haemolytic assay as a preliminary test for identifying highly-irritative products, and also to evaluate the in vitro test as alternative assay for replacement of the in vivo test. In vitro and in vivo analyses were carried out on 19 cosmetic products, in order to correlate the lesions in the ocular structures with three in vitro parameters: (i) the extent of haemolysis (H50); (ii) the protein denaturation index (131); and (iii) the H50/DI ratio, which reflects the irritation potential (IP). There was significant correlation between maximum average scores (MAS) and the parameters determined in vitro (r = 0.752-0.764). These results indicate that the RBC assay is a useful and rapid test for use as a screening method to assess the IP of cosmetic products, and for predicting the IP value with a high level of concordance (94.7%). The assay showed high sensitivity and specificity rates of 91.6% and 100%, respectively.
Resumo:
A solid graphite-polyurethane composite electrode has been used to determine release profiles of verapamil, a calcium-channel blocker. The electro-oxidation process was characterized by cyclic voltammetry and electrochemical impedance spectroscopy and showed no adsorption of analyte or oxidation products, unlike at other carbon-based electrodes. Quantification gave linear ranges up to 40molL-1 with cyclic voltammetry and detection limits of 0.7molL-1 by differential pulse and square-wave voltammetry. Commercial product samples were successfully analyzed with results equal to those from spectrophotometry. Because no electrode surface renewal is needed, this electrode material has many advantages.
Resumo:
This study was conducted to evaluate the inclusion of two levels (2.5 e 5.0%) of dried yeast (Saccharomyces cerevisiae) and its by-products, disrupted yeast cells and yeast cell wall in diets for juveniles of pacu (Piaractus mesopotamicus). Production performance, body and plasmatic composition indexes were evaluated. Seven isoproteic (26% digestible protein) and isoenergetic (3.100 kcal digestible energy) diets were formulated containing increased levels of each ingredient. The diets were supplied for 86 days, "ad libitum". Yeast and by-products increase feed efficiency and protein use, when compared to the control diet. Carcass composition and plasmatic (glucose, cortisol, uric acid, urea and plasmatic protein) levels are not affected by the test ingredient supplementation.
Resumo:
An analytical method for the determination of the anti-inflammatory drug 5-aminosalicylic acid (5-ASA) in pharmaceutical formulations using square wave voltammetry at pencil graphite electrodes was developed. After the optimization of the experimental conditions, calibration curves were obtained in the linear concentration range from 9.78 × 10-7 to 7.25 × 10-5 mol L-1 resulting in a limit of detection of 2.12 ± 0.05 x 10-8 mol L-1. Statistical tests showed that the concentrations of 5-ASA in commercial tablets and enemas obtained with the proposed voltammetric method agreed with HPLC values at a 95% confidence level.
Resumo:
Electrochemical behavior of pesticides is extensively studied, but little attention has been given to the study of their degradation products (by-products) by electrochemical methods. However, the degradation products of pesticides can be even more toxic then the parent products and such studies should be encouraged. Therefore, the objective of this work was to evaluate the electroactivity of by-products of imazaquin, methylparathion, bentazon and atrazine, generated by UV irradiation and measured using cyclic and differential pulse voltammetry and UV-visible absorption spectrophotometry. Results have shown that several by-products exhibit electroactivity, allowing, in some cases, the simultaneous determination of both parent and degradation products.
Resumo:
The possibility of using a graphite silicone-rubber composite electrode (GSR) in a differential pulse voltammetric(DPV) procedure for rutin (vitamin P) determination is described. Cyclic voltammograms of rutin presented a reversible pair of oxidation/reduction peaks respectively at 0.411 and 0.390 V (vs. SCE) at the GSR surface in Britton-Robinson(B-R) buffer solution pH 4.0. In DPV after optimization of conditions, an oxidation peak at 0.370 V (vs. SCE) was used to quantitative determination of rutin in B-R buffer solution pH 4.0. In this case a linear dynamic range of 5.0×10-8 to 50.0×10-8 mol L-1 was observed with a detection limit of 1.8×10-8 mol L-1 for the analyte. Recoveries from 94 to 113% were observed. The electrode surface was renewed by polishing after each determination, with a repeatability of 1.09 ± 0.06 µA (n = 10) peak current. Rutin was determined in a pharmaceutical formulation using the proposed electrode and the results agreed with those from an official method within 95% confidence level.