528 resultados para 2-HYDROXYETHYL METHACRYLATE

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)


Relevância:

40.00% 40.00%

Publicador:

Resumo:

The enzymatic kinetic resolution of tert-butyl 2-(1-hydroxyethyl) phenylcarbamate via lipase-catalyzed transesterification reaction was studied. We investigated several reaction conditions and the carbamate was resolved by Candida antarctica lipase B (CAL-B), leading to the optically pure (R)- and (S)-enantiomers. The enzymatic process showed excellent enantioselectivity (E > 200). (R)- and (S)-tert-butyl 2-(1-hydroxyethyl) phenylcarbamate were easily transformed into the corresponding (R)and (S)-1-(2-aminophenyl)ethanols.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The wear resistance of denture teeth is important to the longevity of removable prostheses of edentulous patients. The ability of denture teeth to maintain a stable occlusal relationship over time may be influenced by this property. The purpose of this in vitro study was to evaluate the wear resistance of polymethyl methacrylate (PMMA) denture teeth based on their chemical composition when opposed by a ceramic antagonist. The maxillary canines (n=10) of 3 PMMA denture teeth (Trubyte Biotone, cross-linked PMMA; Trilux, highly cross-linked IPN (interpenetrating polymer network)-PMMA; and Vivodent, highly cross-linked PMMA) were secured in an in vitro 2-body wear-testing apparatus that produced sliding contact of the specimens (4.5 cycles/s, sliding distance of 20 mm, under 37°C running water) against glazed or airborne particle abraded ceramic. Wear resistance was measured as height loss (mm) under 300 g (sliding force) after 100,000 cycles, using a digital measuring microscope. Mean values were analyzed by 2-way ANOVA and Tukey's test (a=0.05). The wear of Trubyte Biotone (0.93 ± 0.14 mm) was significantly higher than that of both other types of teeth tested against abraded ceramic (p<0.05). The Vivodent tooth (0.64 ± 0.17 mm) exhibited the best wear resistance among the denture teeth tested against airborne particle abraded ceramic. There were no statistically significant differences (p>0.05) in wear among the 3 denture teeth evaluated against glazed ceramic. Trilux and Vivodent teeth tested against either glazed or airborne particle abraded ceramic did not differ significantly from each other (p<0.05). All teeth showed significantly more wear against airborne particle abraded ceramic than against glazed ceramic (p<0.05). In conclusion, the three types of PMMA denture teeth presented significantly different wear resistance against the abraded ceramic. The high-strength PMMA denture teeth were more wear-resistant than the conventional PMMA denture tooth.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: This study assessed in vitro the physicochemical properties of 2 methacrylate resin-based sealers (Epiphany SE and Hybrid Root SEAL), comparing the results with a well-established epoxy resin-based sealer (AH Plus). Methods: Five samples of each material were used for each test (setting time, flow, radiopacity, dimensional change after setting, and solubility) according to American National Standards Institute/American Dental Association (ANSI/ADA) Specification 57. The samples were assigned to 3 groups: I, AH Plus; II, Epiphany SE; and III, Hybrid Root SEAL. The distilled and deionized water used at the solubility test was submitted to atomic absorption spectrometry to observe the presence of Ca2+, K+, Ni2+, and Zn2+ ions. In addition, the surface morphology of the specimens was analyzed by means of scanning electron microscopy (SEM). Statistical analysis was performed by using one-way analysis of variance and Tukey-Kramer test (P < .05). Results: Flow, radiopacity, and solubility of all sealers were in accordance with ANSI/ADA. The setting time of Hybrid Root SEAL did not agree with ANSUADA requirements. The dimensional change of all sealers was greater than the values considered acceptable by ANSI/ADA. The spectrometry analysis showed significant Ca2+ ions release for AH Plus. In SEM analysis, Hybrid Root SEAL presented spherical monomers with inferior size than AH Plus and Epiphany SE. Conclusions: It might be concluded that physicochemical properties of the tested sealers conformed to ANSI/ADA (2000) standardization, except for the setting time of Hybrid Root SEAL and the dimensional change of all sealers, which did not fulfill the ANSI/ADA requirements. (J Endod 2010;36:1531-1536)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

P>Aim To assess the push-out strength of Epiphany SE, Epiphany and Hybrid Root SEAL to the dentine walls of root canals. Methodology Sixty roots of canines were prepared and distributed to six groups (n = 10) according to the filling material: GI - Epiphany SE, GII - Epiphany primer and sealer, GIII - Epiphany primer, sealer and resinous solvent, GIV - Clearfil DC Bond and Epiphany sealer, GV - Clearfil, Epiphany sealer and solvent and GVI - Hybrid Root SEAL. Resilon cones were used in all groups. Roots were sectioned transversally to obtain three slices from each third. One slice was subjected to the push-out test (MPa), and results were analysed by anova and Tukey`s test (P < 0.05). The other two slices were prepared for scanning electron microscopy (SEM). Failure mode was also analysed. Results A statistically significant difference (P < 0.05) occurred between Hybrid Root SEAL (5.27 +/- 2.07) and the other materials, GI (0.40 +/- 0.23), GII (0.78 +/- 0.45), GIII (0.57 +/- 0.28), GIV (0.40 +/- 0.24) and GV (0.50 +/- 0.41), which did not differ significantly from each other (P > 0.05). Adhesive failures predominated in groups I, II, IV and V, whilst mixed and cohesive failures were the most frequent in groups III and VI, respectively. There were gaps in the adhesive interface of GI and GII, continuity areas of the filling material with dentine in GIV and GV and good adaptation of the interface of GVI. Conclusion Hybrid Root SEAL had greater push-out strength to root canal dentine than Epiphany SE and Epiphany. The use of primer, solvent and adhesive system did not influence the adhesion of Epiphany.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A polyfluorene derivative of the PPV, poly(9,9`-n-dihexyl-2,7-fluorenedilvinylene-alt-1,4-phenylenevinylene), with a strong tendency to aggregation was blended with several members of a series composed by poly(alkyl methacrylate)s with the following substituents in the ester position: methyl, ethyl, isopropyl, isobutyl, n-butyl, and cyclohexyl. The de-aggregation effect in blends was studied by steady-state photoluminescence spectroscopy using several blend compositions. The efficiency of each dispersing phase was discussed in terms of the polymer miscibility, controlled by interaction parameters between the polyfluorene and every poly(alkyl methacrylate)s, here described using Hilde-brand solubility parameters. (c) 2009 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this work was to evaluate the effect of the storage time on the thermal properties of triethylene glycol dimethacrylate/2,2-bis[4-(2-hydroxy-3-methacryloxy-prop-1-oxy)-phenyl]propane bisphenyl-alpha-glycidyl ether dimethacrylate (TB) copolymers used in formulations of dental resins after photopolymerization. The TB copolymers were prepared by photopolymerization with an Ultrablue IS light-emitting diode, stored in the dark for 160 days at 37 degrees C, and characterized with differential scanning calorimetry (DSC), dynamic mechanical analysis (DMA), and Fourier transform infrared spectroscopy with attenuated total reflection. DSC curves indicated the presence of an exothermic peak, confirming that the reaction was not completed during the photopolymerization process. This exothermic peak became smaller as a function of the storage time and was shifted at higher temperatures. In DMA studies, a plot of the loss tangent versus the temperature initially showed the presence of two well-defined peaks. The presence of both peaks confirmed the presence of residual monomers that were not converted during the photopolymerization process. (C) 2009 Wiley Periodicals, Inc. J Appl Polym Sci 112: 679-684, 2009

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Adjunctive therapeutic strategies that modulate the inflammatory mediators can play a significant role in periodontal therapy. In this double-blind, placebo-controlled study, 60 subjects diagnosed as periodontitis patients were evaluated for 28 days after periodontal treatment combined with selective cyclooxygenase-2 (COX-2) inhibitor. The experimental group received scaling and root planning (SRP) combined with the Loxoprofen antiinflammatory drug (SRP+Loxoprofen). The control group received SRP combined with placebo (SRP+placebo). Plaque index (PI), probing pocket depth (PD) and bleeding on probing (BOP) were monitored with an electronic probe at baseline and after 14 and 28 days. Both groups displayed clinical improvement in PD, PI and BOP. They also showed statistically similar values (p>0.05) of PD reduction on day 14 (0.4 mm) and on day 28 (0.6 mm). At the baseline, few deeper sites (>7 mm) from SRP+Loxoprofen group were responsible and most PD reduction was observed after 14 days (p<0.05). The percentage of remaining deep pockets (>7 mm) after 14 days in the SRP+Loxoprofen group was significantly lower (p<0.05) than in the SRP+placebo group. Loxoprofen presents potential effect as an adjunct of periodontal disease treatment, but long-term clinical trials are necessary to confirm its efficacy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluate the tissue compatibility of a silorane-based resin system (FiltekTM Silorane) and a methacrylate-based nanoparticle resin (FiltekTM Supreme XT) after implantation in the subcutaneous connective tissue of isogenic mice. One hundred and thirty five male isogenic BALB/c mice were randomly assigned to 12 experimental and 3 control groups, according to the implanted material and the experimental period of 7, 21 and 63 days. At the end of each period, the animals were killed and the tubes with the surrounding tissues were removed and processed for microscopic analysis. Samples were subjected to a descriptive and a semi-quantitative analyses using a 4-point scoring system (0-3) to evaluate the collagen fiber formation and inflammatory infiltrate. Data were statistically analyzed using the Kruskal Wallis test (?=0.05). The results showed that there was no significant difference between the experimental and control groups considering the three evaluation periods (p>0.05). The silorane-based and the methacrylate-based nanoparticle resins presented similar tissue response to that of the empty tube (control group) after subcutaneous implantation in isogenic mice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fluorinated denture base acrylic resins can present more stable physical properties when compared with conventional polymers. This study evaluated the incorporation of a fluoroalkyl methacrylate (FMA) mixture in a denture base material and its effect on roughness and flexural strength. A swelling behavior assessment of acrylic resin specimens (n=3, per substance) after 12 h of FMA or methyl methacrylate (MMA) immersion was conducted to determine the solvent properties. Rectangular specimens (n=30) were allocated to three groups, according to the concentration of FMA substituted into the monomer component of a heat-polymerized acrylic resin (Lucitone 550), as follows: 0% (control), 10% and 20% (v/v). Acrylic resin mixed with concentrations of 25% or more did not reach the dough stage and was not viable. The surface roughness and flexural strength of the specimens were tested. Variables were analyzed by ANOVA and Tukey's test (a=0.05). Immersion in FMA produced negligible swelling, and MMA produced obvious swelling and dissolution of the specimens. Surface roughness at concentrations of 0%, 10% and 20% were: 0.25 ± 0.04, 0.24 ± 0.04, 0.22 ± 0.03 mm (F=1.78; p=0.189, not significant). Significant differences were found for flexural strength (F=15.92; p<0.001) and modulus of elasticity (F=7.67; p=0.002), with the following results: 96 ± 6, 82 ± 5, 84 ± 6 MPa, and 2,717 ± 79, 2,558 ± 128, 2574 ± 87 MPa, respectively. The solvent properties of FMA against acrylic resin are weak, which would explain why concentrations over 20% were not viable. Surface changes were not detected after the incorporation of FMA in the denture base acrylic resin tested. The addition of FMA into denture base resin may lower the flexural strength and modulus of elasticity, regardless of the tested concentration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Accelerated stability tests are indicated to assess, within a short time, the degree of chemical degradation that may affect an active substance, either alone or in a formula, under normal storage conditions. This method is based on increased stress conditions to accelerate the rate of chemical degradation. Based on the equation of the straight line obtained as a function of the reaction order (at 50 and 70 ºC) and using Arrhenius equation, the speed of the reaction was calculated for the temperature of 20 ºC (normal storage conditions). This model of accelerated stability test makes it possible to predict the chemical stability of any active substance at any given moment, as long as the method to quantify the chemical substance is available. As an example of the applicability of Arrhenius equation in accelerated stability tests, a 2.5% sodium hypochlorite solution was analyzed due to its chemical instability. Iodometric titration was used to quantify free residual chlorine in the solutions. Based on data obtained keeping this solution at 50 and 70 ºC, using Arrhenius equation and considering 2.0% of free residual chlorine as the minimum acceptable threshold, the shelf-life was equal to 166 days at 20 ºC. This model, however, makes it possible to calculate shelf-life at any other given temperature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVOS: avaliar a expressão de erbB-2 e dos receptores hormonais para estrógeno e progesterona (RE/RP) nas regiões de transição entre as frações in situ e invasoras de neoplasias ductais da mama (CDIS e CDI, respectivamente). MÉTODOS: oitenta e cinco casos de neoplasias mamárias, contendo regiões contíguas de CDIS e CDI, foram selecionados. Espécimes histológicos das áreas de CDIS e de CDI foram obtidos através da técnica de tissue microarray (TMA). As expressões da erbB-2 e dos RE/RP foram avaliadas por meio de imunoistoquímica convencional. A comparação da expressão da erbB-2 e dos RE/RP nas frações in situ e invasoras da mama foi realizada com emprego do teste de McNemar. Os intervalos de confiança foram determinados em 5% (p=0,05). Foram calculados coeficientes de correlação intraclasse (ICC) para avaliar a concordância na tabulação cruzada da expressão de erbB-2 e RE/RP nas frações de CDIS e CDI. RESULTADOS: a expressão da erbB-2 não diferiu entre as áreas de CDIS e CDI (p=0,38). Comparando caso a caso suas áreas de CDIS e CDI, houve boa concordância na expressão da erbB-2 (coeficiente de correlação intraclasse, ICC=0,64), dos RP (ICC = 0,71) e dos RE (ICC = 0,64). Considerando apenas tumores cujo componente in situ apresentasse áreas de necrose (comedo), o ICC para erbB-2 foi de 0,4, comparado a 0,6 no conjunto completo de casos. Os ICC não diferiram substancialmente daqueles obtidos com o conjunto completo de espécimes em relação aos RE/RP: para RE, ICC=0,7 (versus 0,7 no conjunto completo), e para RP, ICC=0,7 (versus 0,6 no conjunto completo). CONCLUSÕES: nossos achados sugerem que as expressões de erbB-2 e RE/RP não diferem nos componentes contíguos in situ e invasivo em tumores ductais da mama.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluate the following acrylic resins: Clássico®, QC-20® and Lucitone®, recommended specifically for thermal polymerization, and Acron MC® and VIPI-WAVE®, made for polymerization by microwave energy. The resins were evaluated regarding their surface nanohardness and modulus of elasticity, while varying the polymerization time recommended by the manufacturer. They were also compared as to the presence of water absorbed by the samples. The technique used was nanoindentation, using the Nano Indenter XP®, MTS. According to an intra-group analysis, when using the polymerization time recommended by the manufacturer, a variation of 0.14 to 0.23 GPa for nanohardness and 2.61 to 3.73 GPa for modulus of elasticity was observed for the thermally polymerized resins. The variation for the resins made for polymerization by microwave energy was 0.15 to 0.22 GPa for nanohardness and 2.94 to 3.73 GPa for modulus of elasticity. The conclusion was that the Classico® resin presented higher nanohardness and higher modulus of elasticity values when compared to those of the same group, while Acron MC® presented the highest values for the same characteristics when compared to those of the same group. The water absorption evaluation showed that all the thermal polymerization resins, except for Lucitone®, presented significant nanohardness differences when submitted to dehydration or rehydration, while only Acron MC® presented no significant differences when submitted to a double polymerization time. Regarding the modulus of elasticity, it was observed that all the tested materials and products, except for Lucitone®, showed a significant increase in modulus of elasticity when submitted to a lack of hydration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to investigate the association between bottle feeding and prevalence rates of increased overjet and Class 2 primary canine relationship. The sample consisted of 911 children (461 boys, 450 girls) aged 3 (13.9%), 4 (40.8%), 5 (34%) and 6 (11.3%) years, with complete primary dentition. Information about nutritive and nonnutritive (pacifier and/or digit) sucking habits was collected through questionnaires. Three calibrated dentists (κ: 0.9-1.0 and Rs > 0.90) performed the clinical assessments. The children were divided into four groups: G1 - not bottle-fed; G2 - exclusively bottle-fed; G3 - breast- and bottle-fed, bottle feeding ceased before 3 years of age; and G4 - breast- and bottle-fed, bottle feeding ceased between 3 and 4 years of age. Associations between nutritive and nonnutritive sucking behaviors and the malocclusions studied were analyzed by multiple binary logistic regression (α= 0.05). The frequencies of increased overjet were: 25.3% (G1), 38.8% (G2), 39.2% (G3) and 47.8% (G4). The percentages of Class 2 canine relationship were: 27.9% (G1), 48.8% (G2), 43.4% (G3) and 43% (G4). No significant effect of bottle feeding was found. The chances of diagnosing increased overjet (O.R. = 4.42, p < 0.001) and Class 2 canine relationship (O.R. = 4.02, p < 0.001) were greater for children with pacifier and/or digit-sucking habits, compared to those without a history of nonnutritive sucking behavior. It may be suggested that bottle feeding alone is not directly associated with higher prevalence rates of increased overjet and Class 2 canine relationship in the primary dentition.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Association studies between ADIPOR1 genetic variants and predisposition to type 2 diabetes (DM2) have provided contradictory results. We determined if two single nucleotide polymorphisms (SNP c.-8503G>A and SNP c.10225C>G) in regulatory regions of ADIPOR1 in 567 Brazilian individuals of European (EA; N = 443) or African (AfA; N = 124) ancestry from rural (quilombo remnants; N = 439) and urban (N = 567) areas. We detected a significant effect of ethnicity on the distribution of the allelic frequencies of both SNPs in these populations (EA: -8503A = 0.27; AfA: -8503A = 0.16; P = 0.001 and EA: 10225G = 0.35; AfA: 10225G = 0.51; P < 0.001). Neither of the polymorphisms were associated with DM2 in the case-control study in EA (SNP c.-8503G>A: DM2 group -8503A = 0.26; control group -8503A = 0.30; P = 0.14/SNP 10225C>G: DM2 group 10225G = 0.37; control group 10225G = 0.32; P = 0.40) and AfA populations (SNP c.-8503G>A: DM2 group -8503A = 0.16; control group -8503A = 0.15; P = 0.34/SNP 10225C>G: DM2 group 10225G = 0.51; control group 10225G = 0.52; P = 0.50). Similarly, none of the polymorphisms were associated with metabolic/anthropometric risk factors for DM2 in any of the three populations, except for HDL cholesterol, which was significantly higher in AfA heterozygotes (GC = 53.75 ± 17.26 mg/dL) than in homozygotes. We conclude that ADIPOR1 polymorphisms are unlikely to be major risk factors for DM2 or for metabolic/anthropometric measurements that represent risk factors for DM2 in populations of European and African ancestries.