136 resultados para interfacial polarization
Resumo:
Purpose: To compare the ability of Subjective assessment of optic nerve head (ONH) and retinal nerve fiber layer (RNFL) by general ophthalmologists and by a glaucoma expert with objective measurements by optical coherence tomography (Stratus OCT, Carl Zeiss Meditec Inc), confocal scanning laser ophthalmoscope (HRT III; Heidelberg Engineering, Heidelberg. Germany), and scanning laser polarimetry (GDx enhanced corneal compensation; Carl Zeiss Meditec Inc, Dublin, CA) in discriminating glaucomatous and normal eyes. Methods: Sixty-one glaucomatous and 57 normal eyes or 118 subjects Were included in the study. Three independent general ophthalmologists and I glaucoma expert evaluated ONH stereo-photographs. Receiver operating characteristic curves were constructed for each imaging technique and sensitivity at fixed specificity was estimated. Comparisons or areas under these curves (aROCs) and agreement (k) were determined between stereophoto grading and best parameter from each technique. Results: Best parameter from each technique showed larger aROC (Stratus OCT RNFL 0.92; Stratus OCT ONH vertical integrated area = 0.86; Stratus OCT macular thickness = 0.82; GDx enhanced corneal compensation = 0.91, HRT3 global cup-to-disc ratio = 0.83; HRT3 glaucoma probability score numeric area score 0.83) compared with stereophotograph grading by general ophthalmologists (0.80) in separating glaucomatous and normal eyes. Glaucoma expert stereophoto grading provided equal or larger aROC (0.92) than best parameter of each computerized imaging device. Stereophoto evaluated by a glaucoma expert showed better agreement with best parameter of each quantitative imaging technique in classifying eyes either as glaucomatous or normal compared with stereophoto grading by general ophthalmologists, The combination Of Subjective assessment of the optic disc by general ophthalmologists with RNFL objective parameters improved identification of glaucoma patients in a larger proportion than the combination of these objective parameters with Subjective assessment of the optic disc by a glaucoma expert (29.5% vs. 19.7%, respectively). Conclusions: Diagnostic ability of all imaging techniques showed better performance than subjective assessment of the ONH by general ophthalmologists, but not by It glaucoma expert, Objective RNFL measurements may provide improvement in glaucoma detection when combined with subjective assessment of the optic disc by general ophthalmologists or by a glaucoma expert.
Resumo:
The aim of this study was to evaluate the effect of the pulsed ultrasound therapy (PUT) in stimulating myoregeneration and collagen deposition in an experimental model of lacerative gastrocnemius muscle lesion in 30 Wistar rats. Fifteen rats were treated (TG) daily with 1 MHz pulsed ultrasound (50%) at 0.57 W/cm(2) for 5 min, and 15 were control animals (CG). Muscle samples were analyzed on postoperative days 4, 7 and 14 through H&E, Picrosirius-polarization and immunohistochemistry for desmin. The lesions presented similar inflammatory responses in both treated and control groups. The areal fraction of fibrillar collagen was larger in the TG at 4 days post-operatively (17.53 +/- 6.2% vs 6.79 +/- 1.3%, p = 0.0491), 7 days (31.07 +/- 7.45% vs 12.57 +/- 3.6%, p = 0.0021) and 14 days (30.39 +/- 7.3% vs 19.13 +/- 3.51%, p = 0.0118); the areal fraction of myoblasts and myotubes was larger in the TG at 14 days after surgery (41.66 +/- 2.97% vs 34.83 +/- 3.08%, p = 0.025). Our data suggest that the PUT increases the differentiation of muscular lineage cells, what would favor tissue regeneration. On the other hand, it is also suggested that there is a larger deposition of collagenous fibers, what could mean worse functional performance. However, the percentage of fibers seems to have stabilized at day 7 in TG and kept increasing in CG. Furthermore, the collagen supramolecular organization achieved by the TG is also significant according to the Sirius red staining results. (C) 2008 Elsevier B.V. All rights reserved.
Resumo:
Objective/Hypothesis: To describe the arrangement of collagen fibers in the superficial layer of the lamina propria of the vocal folds with Reinke` edema. Study Design: Cross sectional analysis of the lamina propria of the vocal folds with Reinke`s edema (RE). Method: The picrosirius polarization method was used to study the arrangement of collagen fiber. Findings of collagen disarrangement were categorized semiquantitatively and correlated with RE severity, age, cigarette smoking and duration of dysphonia. Results: Analysis of 20 specimens of vocal folds with RE showed that the intertwined network of collagen fibers resembling a wicker-basket normally observed in vocal folds was disarranged in RE. The collagen fibers were loosely arranged, fragmented and intermixed with varying amounts of myxoid stroma. Moderate and large areas of disarrangement (90% of cases) predominated. Collagen fiber arrangement in the region underneath the epithelium was better preserved when compared with fibers in the deeper region of the superficial layer of the lamina propria. There was a statistical difference in collagen disarrangement between grade II and grade III severity (P = .007) that appeared to be due to the large areas of disarrangement observed in 73% of patients with grade III severity and in 44% of grade II severity. Age was the only variable correlated with collagen fiber disarrangement (r = 0.47, P = .037). Conclusion: Our findings suggest that the flexible framework which maintains the uniformity of the lamina propria was lost in RE caused by the disarrangement of the collagen fibers.
Resumo:
Objectives: To analyze the presence and distribution of collagen fibers and versican in human vocal fold lamina propria of fetal larynges. Study Design: Cross sectional analysis of cadaveric vocal folds of human fetuses. Methods: Seven fetal larynges obtained from 28- to 36-week-old fetuses were analyzed with the Picrosirius-polarization method, immunohistochemistry, and image analysis. Results: Collagen fibers within the lamina propria exhibited a monolaminar distribution pattern and spatial arrangement in ""wicker basket."" Versican distribution was larger in the superficial and intermediate layers when compared to the deep layer. Conclusion: Our findings suggest that collagen and versican distribution and arrangement within the lamina propria in the developing fetus are important for vocalization at birth.
Resumo:
Although it is currently believed that the vocal ligament of humans undergoes considerable development postnatally, there is no consensus as to the age at which it first emerges. In the newborn infant, the lamina propria has been described as containing a sparse collection of relatively unorganized fibres. In this study we obtained larynges from autopsy of human fetuses aged 7-9 months and used light and electron microscopy to study the collagenous and elastic system fibres in the lamina propria of the vocal fold. Collagen fibres were viewed using the Picrosirius polarization method and elastic system fibres were stained using Weigert`s resorcin-fuchsin after oxidation with oxone. The histochemical and electron microscopic observations were consistent, showing collagen populations with an asymmetric distribution across different compartments of the lamina propria. In the central region, the collagen appeared as thin, weakly birefringent, greenish fibres when viewed using the Picrosirius polarization method, whereas the superficial and deep regions contained thick collagen fibres that displayed a strong red or yellow birefringence. These findings suggest that the thin fibres in the central region consist mainly of type III collagen, whereas type I collagen predominates in the superficial and deep regions, as has been reported in studies of adult vocal folds. Similarly, elastic system fibres showed a differential distribution throughout the lamina propria. Their distribution pattern was complementary to that of collagen fibres, with a much greater density of elastic fibres apparent in the central region than in the superficial and deep regions. This distribution of collagen and elastic fibres in the fetal vocal fold mirrors that classically described for the adult vocal ligament, suggesting that a vocal ligament has already begun to develop by the time of birth. The apparently high level of organization of connective tissue components in the newborn is in contrast to current hypotheses that argue that the mechanical stimuli of phonation are essential to the determination of the layered structure of the lamina propria and suggests that genetic factors may play a more significant role in the development of the vocal ligament than previously believed.
Resumo:
PURPOSE: To compare the abilities of scanning laser polarimetry (SLP) with enhanced corneal compensation (ECC) and variable corneal compensation (VCC) modes for detection of retinal nerve fiber layer (RNFL) loss in eyes with band atrophy (BA) of the optic nerve. DESIGN. Cross-sectional study. METHODS: Thirty-seven eyes from 37 patients with BA and temporal visual field defect from chiasmal compression and 40 eyes from 40 healthy subjects were studied. Subjects underwent standard automated perimetry and RNFL measurements using an SLP device equipped with VCC and ECC. Receiver operating characteristic (ROC) curves were calculated for each parameter. Pearson correlation coefficients were obtained to evaluate the relationship between RNFL thickness parameters and severity of visual field loss, as assessed by the temporal mean defect. RESULTS: All RNFL thickness parameters were significantly lower in eyes with BA compared with normal eyes with both compensation modes. However, no statistically significant differences were observed in the areas under the ROC curves for the different parameters between GDx VCC and ECC (Carl Zeiss Meditec, Inc, Dublin, California, USA). Structure-function relationships also were similar for both compensation modes. CONCLUSIONS: No significant differences were found between the diagnostic accuracy of GDx ECC and that of VCC for detection of BA of the optic nerve. The use of GDx ECC does not seem to provide a better evaluation of RNFL loss on the temporal and nasal sectors of the peripapillary retina in subjects with BA of the optic nerve.
Resumo:
Preliminary findings suggest that transcranial direct current stimulation (tDCS) can have antidepressant effects. We sought to test this further in a parallel-group, double-blind clinical trial with 40 patients with major depression, medication-free randomized into three groups of treatment: anodal tDCS of the left dorsolateral prefrontal cortex (active group-`DLPFC`); anodal tDCS of the occipital cortex (active control group-`occipital`) and sham tDCS (placebo control group-`sham`). tDCS was applied for 10 sessions during a 2-wk period. Mood was evaluated by a blinded rater using the Hamilton Depression Rating Scale (HDRS) and Beck Depression Inventory (BDI). The treatment was well tolerated with minimal side-effects that were distributed equally across all treatment groups. We found significantly larger reductions in depression scores after DLPFC tDCS [HDRS reduction of 40.4 % (+/-25.8%)] compared to occipital [HDRS reduction of 21.3 % ( +/-12.9%)] and sham tDCS [HDRS reduction of 10.4 % (+/-36.6%)]. The beneficial effects of tDCS in the DLPFC group persisted for 1 month after the end of treatment. Our findings support further investigation on the effects of this novel potential therapeutic approach - tDCS - for the treatment of major depression.
Resumo:
Objective: To determine the elution characteristics of the antibiotic (gentamicin) mixed with bone cement. Methods: 480mg of gentamicin was added to 40g of bone cement. Ten specimens were immersed in buffered saline solution for 28 days. Samples of days 1, 2, 7, 14, 21 and 28 were analyzed by the fluorescence polarization immunoassay method, Results: Most of the gentamicin was eluted from the cement in the first 24 hours. A gradual downslide occurred between days 2 and 14. By the 28th day, there was no trace of the antibiotic. Conclusion: The mixture released high amounts of the antibiotic in a predictable (therapeutic) manner during at least fourteen days.
Resumo:
Type 17 helper T (Th17) cells are implicated in the pathogenesis many of human autoimmune diseases. Development of Th17 can be enhanced by the activation of aryl hydrocarbon receptor (AHR) whose ligands include the environmental pollutant dioxin, potentially linking environmental factors to the increased prevalence of autoimmune disease. We report here that nitric oxide (NO) can suppress the proliferation and function of polarized murine and human Th17 cells. NO also inhibits AHR expression in Th17 cells and the downstream events of AHR activation, including IL-22, IL-23 receptor, and Cyp1a1. Conversely, NO did not affect the polarization of Th17 cells from mice deficient in AHR. Furthermore, mice lacking inducible nitric oxide synthase (Nos2(-/-)) developed more severe experimental autoimmune encephalomyelitis than WT mice, with elevated AHR expression, increased IL-17A, and IL-22 synthesis. NO may therefore represent an important endogenous regulator to prevent overexpansion of Th17 cells and control of autoimmune diseases caused by environmental pollutants.
Resumo:
Bothropstoxin-I (BthTx-I) is a homodimerie Lys49-PLA(2) from the venom of the snake Bothrops jararacussu, which lacks hydrolytic activity against phospholipid substrates, yet permeabilizes membranes by a Ca2+- independent mechanism. The interaction of the BthTx-I with model membranes has been studied by intrinsic tryptophan fluorescence emission (ITFE) spectroscopy. Nine separate mutants have been created each with a unique tryptophan residue located at a different position in the interfacial recognition site (IRS) of the protein. The rapid and efficient Ca2+-independent membrane damage against unilamellar liposomes composed of DPPC/DMPA in a 9:1 molar ratio was unaffected by these substitutions. Binding studies revealed low protein affinity for these liposomes and no changes were observed in the ITFE properties. In contrast, the binding of all mutants to DPPC/DMPA liposomes in a 1:1 molar ratio was stronger, and was correlated with altered ITFE properties. The blue-shifted emission spectra and increased emission intensity of mutants at positions 31, 67 and 115-117 in the interface recognition surface of the protein suggest these regions are partially inserted into the membrane. These results are consistent with a model for the Ca2+-independent membrane damaging mechanism that involves a transient interaction of the protein with the outer phospholipid leaflet of the target membrane. (C) 2007 Elsevier Masson SAS. All rights reserved.
Resumo:
P>According to the hygiene hypothesis, the increased incidence of allergic and autoimmune diseases in developed countries is mainly explained by the decreased contact between the human population and certain environmental agents as lactobacillus, mycobacteria and helminths. In this study, we evaluated the effect of multiple infections with Strongyloides venezuelensis on the development of experimental autoimmune encephalomyelitis (EAE) in Lewis rats. Multiple infections before EAE induction were not able to change the evolution of the disease. No alterations were observed in weight loss, clinical score and inflammation intensity at the central nervous system. The presence of significant levels of parasite-specific IgG1 but not IgG2b suggested a Th2 polarization. However, the percentage and absolute number of CD4+CD25+Foxp3+ T cells were not changed, being their levels in the spleen and lymph nodes of infected rats comparable to the ones found in normal animals. These results suggest that a Th2-polarized response without concomitant expansion of Foxp3+ regulatory T cells was not able to modify EAE progression. Even though these results do not threaten the hygiene hypothesis, they suggest that this paradigm might be an oversimplification. They also emphasize the need of a study to compare the immunoregulatory ability associated with different helminth spp.
Resumo:
Purpose: To assess the effects of three different dental adhesive systems on the formation of secondary root caries, in vitro, with a standardized interfacial gap in a filled cavity model. Methods: 40 sound human molars were selected and randomly assigned to four experimental groups: Clearfil SE Bond (CSEB), Xeno III (X-III), Scotchbond Multi-Purpose Plus (SBMP) and negative control (NC) without an adhesive system. After the standardized Class V cavity preparations on the buccal and lingual surfaces, restorations were placed with resin composite (Filtek Z250) using a standardized interfacial gap, using a 3 x 2 mm piece of 50 mu m metal matrix. The teeth were sterilized with gamma irradiation and exposed to a cariogenic challenge using a bacterial system with Streptococcus mutans. Depth and extension of wall lesions formed and the depth of outer lesions were measured by software coupled with light microscopy. Results: For wall lesion extension the ANOVA test showed differences between groups except between X-HI and SBMP (P= 0.294). The Tukey`s test of confidence intervals indicated smaller values for the CSEB group than for the others. For wall lesion depth the CSEB group also presented the smallest mean values of wall lesion depth when compared to the others (P< 0.0001) for all comparisons using Tukey`s test. Regarding outer lesion depth, all adhesives showed statistically similar behavior. SEM evaluation of the morphologic appearance of caries lesions confirmed the statistical results showing small caries lesion development for cavities restored with CSEB adhesive system, which may suggest that this adhesive system interdiffusion zone promoted a good interaction with subjacent dentin protecting the dental tissues from recurrent caries. (Am J Dent 2010;23:93-97).
Resumo:
Objectives: To evaluate the efficacy of simplified dehydration protocols, in the absence of tubular occlusion, on bond strength and interfacial nanoleakage of a hydrophobic experimental adhesive blend to acid-etched, ethanol-dehydrated dentine immediately and after 6 months. Methods: Molars were randomly assigned to 6 treatment groups (n = 5). Under pulpal pressure simulation, dentine crowns were acid-etched with 35% H(3)PO(4) and rinsed with water. Adper Scotchbond Multi-Purpose was used for the control group. The remaining groups had their dentine surface dehydrated with ethanol solutions: group 1 = 50%, 70%, 80%, 95% and 3 x 100%, 30 s for each application; group 2 the same ethanol sequence with 15 s for each solution; groups 3, 4 and 5 used 100% ethanol only, applied in seven, three or one 30 s step, respectively. After dehydration, a primer (50% BisGMA + TEGDMA, 50% ethanol) was used, followed by the neat comonomer adhesive application. Resin composite build-ups were then prepared using an incremental technique. Specimens were stored for 24 h, sectioned into beams and stressed to failure after 24 h or after 6 months of artificial ageing. Interfacial silver leakage evaluation was performed for both storage periods (n = 5 per subgroup). Results: Group 1 showed higher bond strengths at 24 h or after 6 months of ageing (45.6 +/- 5.9(a)/43.1 +/- 3.2(a) MPa) and lower silver impregnation. Bond strength results were statistically similar to control group (41.2 +/- 3.3(ab)/38.3 +/- 4.0(ab) MPa), group 2 (40.0 +/- 3.1(ab)/38.6 +/- 3.2(ab) MPa), and group 3 at 24 h (35.5 +/- 4.3(ab) MPa). Groups 4 (34.6 +/- 5.7(bc)/25.9 +/- 4.1(c) MPa) and 5 (24.7 +/- 4.9(c)/18.2 +/- 4.2(c) MPa) resulted in lower bond strengths, extensive interfacial nanoleakage and more prominent reductions (up to 25%) in bond strengths after 6 months of ageing. Conclusions: Simplified dehydration protocols using one or three 100% ethanol applications should be avoided for the ethanol-wet bonding technique in the absence of tubular occlusion, as they showed decreased bond strength, more severe nanoleakage and reduced bond stability over time. (C) 2009 Elsevier Ltd. All rights reserved.
Resumo:
Objective. The goal of this paper is to undertake a literature search collecting all dentin bond strength data obtained for six adhesives with four tests ( shear, microshear, tensile and microtensile) and to critically analyze the results with respect to average bond strength, coefficient of variation, mode of failure and product ranking. Method. A PubMed search was carried out for the years between 1998 and 2009 identifying publications on bond strength measurements of resin composite to dentin using four tests: shear, tensile, microshear and microtensile. The six adhesive resins were selected covering three step systems ( OptiBond FL, Scotch Bond Multi-Purpose Plus), two-step (Prime & Bond NT, Single Bond, Clear. l SE Bond) and one step (Adper Prompt L Pop). Results. Pooling results from 147 references showed an ongoing high scatter in the bond strength data regardless which adhesive and which bond test was used. Coefficients of variation remained high (20-50%) even with the microbond test. The reported modes of failure for all tests still included high number of cohesive failures. The ranking seemed to be dependant on the test used. Significance. The scatter in dentin bond strength data remains regardless which test is used confirming Finite Element Analysis predicting non-uniform stress distributions due to a number of geometrical, loading, material properties and specimens preparation variables. This reopens the question whether, an interfacial fracture mechanics approach to analyze the dentin - adhesive bond is not more appropriate for obtaining better agreement among dentin bond related papers. (C) 2009 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Resumo:
This study examined the early and long-term microtensile bond strengths (mu TBS) and interfacial enamel gap formation (IGW) of two-step selfetch systems to unground and ground enamel. Resin composite (Filtek Z250) buildups were bonded to proximal enamel surfaces (unground, bur-cut or SiC-treated enamel) of third molars after the application of four self-etch adhesives: a mild (Clearfil SE Bond [SE]), two moderate (Optibond Solo Plus Self-Etch Primer [SO] and AdheSE [AD]) and a strong adhesive (Tyrian Self Priming Etchant + One Step Plus [TY]) and two etch-and-rinse adhesive systems (Single Bond [SB] and Scotchbond Multi-Purpose Plus [SBMP]). Ten tooth halves were assigned for each adhesive. After storage in water (24 hours/37 degrees C), the bonded specimens were sectioned into beams (0.9 mm(2)) and subjected to mu TBS (0.5 mm/minute) or interfacial gap width measurement (stereomicroscope at 400x) either immediately (IM) or after 12 months (12M) of water storage. The data were analyzed by three-way repeated measures ANOVA and Tukey`s test (alpha=0.05). No gap formation was observed in any experimental condition. The mu TBS in the Si-C paper and diamond bur groups were similar and greater than the unground group only for the moderate self-etch systems (SO and AD). No reductions in bond strength values were observed after 12 months of water storage, regardless of the adhesive evaluated.