133 resultados para Radioactive decay


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The electrochemical treatment of a synthetic tannery wastewater prepared with 30 compounds used in animal skin processing was studied. Electrolyses were performed in a one-compartment flow cell at a current density of 20 mA cm(-2), using a dimensionally stable anode (DSA (R)) of composition Ti/Ir(0.10)Sn(0.90)O(2) as the working electrode. Effects of chloride concentration and presence of sulfate were evaluated. Variation in the concentration of phenolic compounds as a function of electrolysis time revealed a first-order exponential decay; faster phenol removals were obtained with increasing chloride concentration in the wastewater. Lower phenol removals were obtained in the presence of sulfate. Higher chloride concentrations led to a faster decrease in total organic carbon (TOC), chemical oxygen demand (COD), and absorbance values at 228 nm. Faster wastewater color removal, higher current efficiency and lower energy consumption were also obtained. This electrochemical treatment was also able to reduce the wastewater toxicity for Daphnia similis. (C) 2008 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We investigated three amino derivatives of ortho-aminobenzoic or anthranilic acid (o-Abz): a) 2-Amino-benzamide (AbzNH(2)); b) 2-Amino-N-methyl-benzamide (AbzNHCH(3)) and c) 2-Amino-N-N`-dimethyl-bezamide (AbzNH(CH(3))(2)), see Scheme 1. We describe the results of ab-initio calculations on the structural characteristics of the compounds and experimental studies about solvent effects in their absorption and steady-state and time-resolved emission properties. Ab-initio calculations showed higher stability for the rotameric conformation in which the oxygen of carbonyl is near to the nitrogen of ortho-amino group. The derivatives present decrease in the delocalization of pi electron, and absorption bands are blue shifted compared to the parent compound absorption, the extent of the effect increasing from to Abz-NH(2) to Abz-NHCH(3) Abz-NH(CH(3))(2). Measurements performed in several solvents have shown that the the dependence of Stokes shift of the derivatives with the orientational polarizability follows the Onsager-Lippert model for general effects of solvent. However deviation occurred in solvents with properties of Bronsted acids, or electron acceptor characteristics, so that hydrogen bonds formed with protic solvents predominates over intramolecular hydrogen bond. In most solvents the fluorescence decay of AbzNH(2) and AbzNHCH(3) was fitted to a single exponential with lifetimes around 7.0 ns and no correlation with polarity of the solvent was observed. The fluorescence decay of AbzN(CH(3))(2) showed lifetimes around 2.0 ns, consistent with low quantum yield of the compound. The spectroscopic properties of the monoamino derivative AbzNHCH(3) are representative of the properties presented by Abz labelled peptides and fatty acids previously studied.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Radiation dose calculations in nuclear medicine depend on quantification of activity via planar and/or tomographic imaging methods. However, both methods have inherent limitations, and the accuracy of activity estimates varies with object size, background levels, and other variables. The goal of this study was to evaluate the limitations of quantitative imaging with planar and single photon emission computed tomography (SPECT) approaches, with a focus on activity quantification for use in calculating absorbed dose estimates for normal organs and tumors. To do this we studied a series of phantoms of varying complexity of geometry, with three radionuclides whose decay schemes varied from simple to complex. Four aqueous concentrations of (99m)Tc, (131)I, and (111)In (74, 185, 370, and 740 kBq mL(-1)) were placed in spheres of four different sizes in a water-filled phantom, with three different levels of activity in the surrounding water. Planar and SPECT images of the phantoms were obtained on a modern SPECT/computed tomography (CT) system. These radionuclides and concentration/background studies were repeated using a cardiac phantom and a modified torso phantom with liver and ""tumor"" regions containing the radionuclide concentrations and with the same varying background levels. Planar quantification was performed using the geometric mean approach, with attenuation correction (AC), and with and without scatter corrections (SC and NSC). SPECT images were reconstructed using attenuation maps (AM) for AC; scatter windows were used to perform SC during image reconstruction. For spherical sources with corrected data, good accuracy was observed (generally within +/- 10% of known values) for the largest sphere (11.5 mL) and for both planar and SPECT methods with (99m)Tc and (131)I, but were poorest and deviated from known values for smaller objects, most notably for (111)In. SPECT quantification was affected by the partial volume effect in smaller objects and generally showed larger errors than the planar results in these cases for all radionuclides. For the cardiac phantom, results were the most accurate of all of the experiments for all radionuclides. Background subtraction was an important factor influencing these results. The contribution of scattered photons was important in quantification with (131)I; if scatter was not accounted for, activity tended to be overestimated using planar quantification methods. For the torso phantom experiments, results show a clear underestimation of activity when compared to previous experiment with spherical sources for all radionuclides. Despite some variations that were observed as the level of background increased, the SPECT results were more consistent across different activity concentrations. Planar or SPECT quantification on state-of-the-art gamma cameras with appropriate quantitative processing can provide accuracies of better than 10% for large objects and modest target-to-background concentrations; however when smaller objects are used, in the presence of higher background, and for nuclides with more complex decay schemes, SPECT quantification methods generally produce better results. Health Phys. 99(5):688-701; 2010

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The present study was carried out to investigate the cytogenetic effects of therapeutic exposure to radioiodine preceded by rhTSH in an animal model. Three groups of Wistar rats (n = 6) were used: one group was treated only with I-131 (11.1 MBq/animal); the other two groups received rhTSH (1.2 mu g/rat of either Thyrogen or rhTSH-IPEN, respectively) 24 h before administration of radioiodine. The percentage of lymphocytes with chromosome aberrations and the average number of aberrations and of dicentrics per cell were determined on blood samples collected 24 h, 7 and 30 days after administration of I-131. The data show that the treatment with radioiodine alone or associated with rhTSH resulted in a greater quantity of chromosome alterations in relation to basal values after 24 h, with a gradual decline after 7 and 30 days of treatment. An increase in chromosome alterations was also seen after rhTSH treatment alone. Neither of the treatments, i.e., with I-131 alone or associated with hormone, resulted in an aneugenic effect or influenced the kinetics of cellular proliferation in rat blood lymphocytes. There was no significant difference between the cytogenetic effects of Thyrogen and rhTSH-IPEN treatment. These data suggest that the treatment with radioiodine, associated or not with rhTSH, affects to a limited extent a relatively small number of cells although the occurrence of late stochastic effects could not be discarded.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To clarify whether the metabolism of triglyceride-rich lipoproteins and lipid transfer to high-density lipoprotein (HDL) are altered in patients with polycystic ovary syndrome (PCOS). Design: Case control study. Setting: Endocrinology clinics. Patient(s): Eight normal-weight (NW) and 15 obese (013) patients with PCOS were compared with 10 NW and 10 Ob women without PCOS paired for age and body mass index. Intervention(s): Determination of triglyceride-rich lipoprotein metabolism and lipid transfer to HDL. Main Outcome Measure(s): Participants were injected triglyceride-rich emulsions labeled with (14)C-cholesteryl esters and (3)H-triglycerides and the fractional clearance rate (FCR, in min(-1)) of labels was determined. Lipid transfer from artificial nanoemulsions to HDL was performed by incubating radioactively labeled lipid nanoemulsions with plasma during 1 hour, followed by radioactive counting of HDL-containing supernatant after chemical precipitation. Result(s): Lipolysis estimated by triglyceride FCR was equal in PCOS groups (NW = 0.043 +/- 0.032, Ob = 0.033 +/- 0.009) and respective controls (NW = 0.039 +/- 0.015, Ob = 0.044 +/- 0.019). However, the remnant removal as estimated by cholesteryl ester FCR was reduced in both PCOS groups (NW = 0.005 +/- 0.006, Ob = 0.005 +/- 0.005) compared with controls (NW = 0.016 +/- 0.006, Ob = 0.011 +/- 0.072). Lipid transfer rates were not different among groups, but triglyceride transfer rates were positively correlated with homeostasis model assessment estimate of insulin resistance in PCOS. Conclusion(s): PCOS patients showed decreased removal of atherogenic remnants even when fasting glucose was <100 mg/dL. This reinforces the usefulness of the measures taken to prevent cardiovascular events in PCOS patients. (Fertil Steril (R) 2010;93:1948-56. (C)2010 by American Society for Reproductive Medicine.)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To determine the impact of menopause on lipid transfer from donor lipoproteins to high-density lipoproteins (HDLs)-a process that is related to the protective function of HDL-and the size of HDL particles. Method: Plasma from 22 prernenopausal and 18 postmenopausal nonobese, normolipidemic women paired for age (40-50 years) was incubated in an artificial nanoemulsion labeled with radioactive lipids. Then the HDL fraction was assessed for radioactivity; the percentage of radioactive lipids transferred from the nanoemulsion to HDL was determined; and the size of HDL particles was measured by laser light scattering. Results: There were no differences between the 2 groups in serum concentration of HDL cholesterol (61 12 mg/dL vs 61 +/- 14 mg/dL) or apolipoprotein A(1) (1.5 +/- 0.3 g/L vs 1.5 +/- 0.2 g/L); lipid transfer to HDL; or size of HDL particles (8.8 +/- 0.8 vs 9.0 +/- 0.5 nm). Conclusion: Menopause was not found to affect HDL cholesterol plasma concentration, lipid transfer to HDL, or size of HDL particles in normolipidemic nonobese women. (C) 2008 International Federation of Gynecology and Obstetrics. Published by Elsevier Ireland Ltd.All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background and purpose: Protein kinase (PK) A and the epsilon isoform of PKC (PKC epsilon) are involved in the development of hypernociception (increased sensitivity to noxious or innocuous stimuli) in several animal models of acute and persistent inflammatory pain. The present study evaluated the contribution of PKA and PKC epsilon to the development of prostaglandin E(2) (PGE(2))-induced mechanical hypernociception. Experimental approach: Prostaglandin E(2)-induced mechanical hypernociception was assessed by constant pressure rat paw test. The activation of PKA or PKC epsilon was evaluated by radioactive enzymic assay in the dorsal root ganglia (DRG) of sensory neurons from the hind paws. Key results: Hypernociception induced by PGE(2) (100 ng) by intraplantar (i.pl.) injection, was reduced by i.pl. treatment with inhibitors of PKA [A-kinase-anchoring protein St-Ht31 inhibitor peptide (AKAPI)], PKC epsilon (PKC epsilon I) or adenylyl cyclase. PKA activity was essential in the early phase of the induction of hypernociception, whereas PKC activity was involved in the maintenance of the later phase of hypernociception. In the DRG (L4-L5), activity of PKA increased at 30 min after injection of PGE(2) but PKC activity increased only after 180 min. Moreover, i.pl. injection of the catalytic subunit of PKA induced hypernociception which was markedly reduced by pretreatment with an inhibitor of PKC epsilon, while the hypernociception induced by paw injection of PKC epsilon agonist was not affected by an inhibitor of PKA (AKAPI). Conclusions and implications: Taken together, these findings are consistent with the suggestion that PKA activates PKC epsilon, which is a novel mechanism of interaction between these kinases during the development of PGE(2)-induced mechanical hypernociception.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Seroprevalence data from a representative population were used to estimate the annual incidence of congenital toxoplasmosis in Sao Paulo Metropolitan Region (SPMR). Retrospective anti-toxoplasma IgG serological analysis was conducted to determine age-dependent seroprevalence, force of infection, average age of acquisition of infection and curve of decay of maternally derived antibodies. Seroprevalence was used to calculate the number of new infections. Toxoplasmosis in pregnant women was estimated by total number of deliveries in a given year as a proxy for the number of pregnancies per year. Toxoplasma seroprevalence was 64.9% in women of childbearing age. Average age of acquisition of toxoplasmosis was 10.74 years. The estimated annual incidence of congenital toxoplasmosis varied from 9.5 to 10.6/1000 births in the studied period. The toxoplasmosis seroprevalence model allowed a good incidence estimation of congenital disease in SPMR compared to other published data, indicating that this mathematical approach is useful in calculating the potential demand of congenital disease due to Toxoplasma gondii in a given community.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ten male Holstein calves (74.3 +/- 3.2 kg LW) were used for a trial with trickle infection with Cooperia punctata to evaluate phosphorus (P) kinetics. Five calves were inoculated with 10,000 L(3) stage larvae per week during 35 days, while the other group of five calves was kept as a control. On the 29th day each calf was intravenously injected with 29.6 MBq of a (32)p solution. Blood samples were taken at 24 h periods for 7 days, after which all calves were slaughtered and worms burdens. Faeces, urine and tissue samples were taken for analysis using isotopic dilution and modeling techniques. The number of eggs per gram of faeces (EPG)was 1920 +/- 168 on 28th day and the total number of worms burdens was 11,131 +/- 1500. Infected calves showed lower feed intake and live weight gain, as well as lower P intake, absorption and retention than control calves. The P flows between body compartments were lower for blood to gastrointestinal tract (TGI), TGI to blood, blood to soft tissues, bone balance and soft tissue balance in infected calves when compared to the control. The trickle infection of C punctata affected P metabolism due to the decrease in P retained and live weight due to fall in feed intake. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Quantitation of progesterone (P(4)) in biological fluids is often performed by radioimmunoassay (RIA), whereas liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) has been used much less often. Due to its autoconfirmatory nature, LC-MS/MS greatly minimizes false positives and interference. Herein we report and compare with RIA an optimized LC-MS/MS method for rapid, efficient, and cost-effective quantitation of P(4) in plasma of cattle with no sample derivatization. The quantitation of plasma P(4) released from three nonbiodegradable, commercial, intravaginal P(4)-releasing devices (IPRD) over 192 h in six ovariectomized cows was compared in a pairwise study as a test case. Both techniques showed similar P(4) kinetics (P > 0.05) whereas results of P(4) quantitation by RIA were consistently higher compared with LC-MS/MS (P < 0.05) due to interference and matrix effects. The LC-MS/MS method was validated according to the recommended analytical standards and displayed P(4) limits of detection (LOD) and quantitation (LOQ) of 0.08 and a 0.25 ng/mL, respectively. The high selective LC-MS/MS method proposed herein for P(4) quantitation eliminates the risks associated with radioactive handling; it also requires no sample derivatization, which is a common requirement for LC-MS/MS quantitation of steroid hormones. Its application to multisteroid assays is also viable, and it is envisaged that it may provide a gold standard technique for hormone quantitation in animal reproductive science studies. (C) 2011 Elsevier Inc. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fluorides and chlorhexidine are technologies that are 65 and 40 years old, respectively. This overview argues that current methods of caries prevention are not effective for the high caries risk patient. In this review examples, arguments and recommendations are provided to address the high caries risk patient that include: failure of comprehensive chemical modalities treatments to address the high caries risk patient; ecological alteration - would this be an effective approach?; and biomaterials and oral microbiome research to address the high caries risk patient.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: Up-regulated matrix metalloproteinases may be involved in the development of cardiomyocyte injury and the degradation of troponin associated with acute pulmonary thromboembolism. We examined whether pretreatment with doxycycline (a nonspecific matrix metalloproteinase inhibitor) protects against cardiomyocyte injury associated with acute pulmonary thromboembolism. Design: Controlled animal study. Setting: University research laboratory. Subjects: Mongrel dogs. Interventions: Anesthetized animals received doxycycline (10 mg/kg intravenously) or saline and acute pulmonary thromboembolism was induced with autologous blood clots injected into the right atrium. Control animals received doxycycline (or saline). Measurements and Main Results: Hemodynamic measurements were performed, and acute pulmonary thromboembolism increased baseline mean pulmonary arterial pressure and pulmonary vascular resistance by approximately 160% and 362%, respectively (both p<.05), 120 mins after acute pulmonary thromboembolism. Pretreatment with doxycycline attenuated these increases (to 125% and 232%, respectively; both p<.05). Although acute pulmonary thromboembolism tended to increase the right ventricle maximum rate of isovolumic pressure development and the maximum rate of isovolumic pressure decay, doxycycline produced no effects on these parameters. Gelatin zymograms of right ventricle showed that acute pulmonary thromboembolism marginally increased matrix metalloproteinase-9 (but not matrix metalloproteinase-2) levels in the right ventricle. A fluorometric assay to assess net matrix metalloproteinase activities showed that acute pulmonary thromboembolism increased matrix metalloproteinase activities in the right ventricle by >100% (p<.05), and this finding was confirmed by in situ zymography of the right ventricle. Doxycycline attenuated acute pulmonary thromboembolism-induced increases in right ventricle matrix metalloproteinase activities. Acute pulmonary thromboembolism induced neutrophil accumulation in the right ventricle, as estimated by myeloperoxidase activity, and doxycycline blunted this effect (p<.05). Serum cardiac troponin I concentrations, which reflect cardiomyocyte injury, increased after acute pulmonary thromboembolism, and this increase was attenuated by pretreatment with doxycycline (p<.05). Conclusions: We found evidence supporting the idea that acute pulmonary thromboembolism is associated with increased matrix metalloproteinase activities in the right ventricle, which may lead to degradation of sarcomeric proteins, including cardiac troponin I. Inhibition of matrix metalloproteinases may be an effective therapeutic intervention in the management of acute pulmonary thromboembolism. (Crit Care Med 2011; 39: 349-356)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: The aim of the present study was to evaluate the clinical efficacy of an experimental dentifrice (CH) containing an antimicrobial agent (1% chloramine-T). Materials and Methods: A clinical, fully randomised, double-blind comparative study was designed for 30 selected patients aged 15 to 50 years, with no periodontal disease, decay or other oral diseases, good general health and the presence of dental plaque and sulcus bleeding. Baseline Turesky modified plaque index (PI) and sulcus bleeding index (SBI) were scored for all patients. Volunteers randomly received the experimental dentifrice (CH) or a commercial-brand dentifrice containing triclosan (TR). Both dentifrices were provided in identical, number-labelled tubes, and the subjects were instructed to use the supplied dentifrice only for their usual oral hygiene, three times a day for a duration of 7 days. After 7-day use of dentifrices, the PI and SBI were assessed again. The data obtained were subjected to the Kruskal Wallis test, followed by Dunn`s post hoc test. Results: After 7-day use of dentifrices, the PI scores diminished significantly for both evaluated dentifrices. The SBI values decreased significantly for both experimental and commercial-brand dentifrices. Conclusions: Both dentifrices reduced PI and SBI. By comparing the experimental and gold-standard dentifrice, it was found that there was no statistically significant difference between the PI and SBI scores after their use, suggesting that they exerted a similar effect on the oral health indexes.