154 resultados para RADIOGRAPHIC ASSESSMENT


Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE. To assess whether baseline Glaucoma Probability Score (GPS; HRT-3; Heidelberg Engineering, Dossenheim, Germany) results are predictive of progression in patients with suspected glaucoma. The GPS is a new feature of the confocal scanning laser ophthalmoscope that generates an operator-independent, three-dimensional model of the optic nerve head and gives a score for the probability that this model is consistent with glaucomatous damage. METHODS. The study included 223 patients with suspected glaucoma during an average follow-up of 63.3 months. Included subjects had a suspect optic disc appearance and/or elevated intraocular pressure, but normal visual fields. Conversion was defined as development of either repeatable abnormal visual fields or glaucomatous deterioration in the appearance of the optic disc during the study period. The association between baseline GPS and conversion was investigated by Cox regression models. RESULTS. Fifty-four (24.2%) eyes converted. In multivariate models, both higher values of GPS global and subjective stereophotograph assessment ( larger cup-disc ratio and glaucomatous grading) were predictive of conversion: adjusted hazard ratios (95% CI): 1.31 (1.15 - 1.50) per 0.1 higher global GPS, 1.34 (1.12 - 1.62) per 0.1 higher CDR, and 2.34 (1.22 - 4.47) for abnormal grading, respectively. No significant differences ( P > 0.05 for all comparisons) were found between the c-index values ( equivalent to area under ROC curve) for the multivariate models (0.732, 0.705, and 0.699, respectively). CONCLUSIONS. GPS values were predictive of conversion in our population of patients with suspected glaucoma. Further, they performed as well as subjective assessment of the optic disc. These results suggest that GPS could potentially replace stereophotograph as a tool for estimating the likelihood of conversion to glaucoma.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Axial vertebral rotation, an important parameter in the assessment of scoliosis may be identified on X-ray images. In line with the advances in the field of digital radiography, hospitals have been increasingly using this technique. The objective of the present study was to evaluate the reliability of computer-processed rotation measurements obtained from digital radiographs. A software program was therefore developed, which is able to digitally reproduce the methods of Perdriolle and Raimondi and to calculate semi-automatically the rotation degree of vertebra on digital radiographs. Three independent observers estimated vertebral rotation employing both the digital and the traditional manual methods. Compared to the traditional method, the digital assessment showed a 43% smaller error and a stronger correlation. In conclusion, the digital method seems to be reliable and enhance the accuracy and precision of vertebral rotation measurements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In adolescent idiopathic scoliosis (AIS) there has been a shift towards increasing the number of implants and pedicle screws, which has not been proven to improve cosmetic correction. To evaluate if increasing cost of instrumentation correlates with cosmetic correction using clinical photographs. 58 Lenke 1A and B cases from a multicenter AIS database with at least 3 months follow-up of clinical photographs were used for analysis. Cosmetic parameters on PA and forward bending photographs included angular measurements of trunk shift, shoulder balance, rib hump, and ratio measurements of waist line asymmetry. Pre-op and follow-up X-rays were measured for coronal and sagittal deformity parameters. Cost density was calculated by dividing the total cost of instrumentation by the number of vertebrae being fused. Linear regression and spearman`s correlation were used to correlate cost density to X-ray and photo outcomes. Three independent observers verified radiographic and cosmetic parameters for inter/interobserver variability analysis. Average pre-op Cobb angle and instrumented correction were 54A degrees (SD 12.5) and 59% (SD 25) respectively. The average number of vertebrae fused was 10 (SD 1.9). The total cost of spinal instrumentation ranged from $6,769 to $21,274 (Mean $12,662, SD $3,858). There was a weak positive and statistically significant correlation between Cobb angle correction and cost density (r = 0.33, p = 0.01), and no correlation between Cobb angle correction of the uninstrumented lumbar spine and cost density (r = 0.15, p = 0.26). There was no significant correlation between all sagittal X-ray measurements or any of the photo parameters and cost density. There was good to excellent inter/intraobserver variability of all photographic parameters based on the intraclass correlation coefficient (ICC 0.74-0.98). Our method used to measure cosmesis had good to excellent inter/intraobserver variability, and may be an effective tool to objectively assess cosmesis from photographs. Since increasing cost density only improves mildly the Cobb angle correction of the main thoracic curve and not the correction of the uninstrumented spine or any of the cosmetic parameters, one should consider the cost of increasing implant density in Lenke 1A and B curves. In the area of rationalization of health care expenses, this study demonstrates that increasing the number of implants does not improve any relevant cosmetic or radiographic outcomes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To investigate glomerular development and expression of insulin and insulin-like growth factor receptors in an experimental model of intrauterine growth restriction (IUGR). Material and Methods: We studied three groups of Sprague-Dawley fetuses: IUGR - restricted by ligation of the right uterine artery; C-IUGR - left horn controls, and EC - external controls (non-manipulated). Body and organs were weighed, and glomerular number and volume were analyzed. Expression of IR beta, IRS-1, IRS-2 and IGF-IR beta was analyzed in liver, intestine and kidneys by immunoblotting. Results: Organ/body weight ratios were similar. In IUGR, glomerular number and volume were increased compared to C-IUGR and EC (p < 0.001). In the IUGR liver, increases were found in IGF-IR beta compared to C-IUGR and EC; IR beta compared to EC, and IRS-2 compared to C-IUGR. However, decreases in IR beta were noted in IUGR compared to C-IUGR; IRS-1 compared to C-IUGR and EC, and IRS-2 compared to EC. In IUGR intestine, increases were detected in IR beta, IRS-1 and IGF-IR beta compared to C-IUGR and EC. In IUGR kidneys, increases were observed in IR beta and IGF-IR beta compared to C-IUGR and EC, and IRS-1 compared to EC. Decreased IRS-2 in the intestine and kidney were noticed in IUGR compared to C-IUGR and EC. Conclusion: IUGR fetuses had less glomeruli and alterations in insulin receptors, which may be associated with an increased risk of disease occurrence in adulthood. Copyright (C) 2010 S. Karger AG, Basel

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High-voltage electric injuries have many manifestations, and an important complication is the damage of the central/peripheral nervous system. The purpose of this work was to assess the upper limb dysfunction in patients injured by high-voltage current. The evaluation consisted of analysis of patients` records, cutaneous-sensibility threshold, handgrip and pinch strength and a specific questionnaire about upper limb dysfunctions (DASH) in 18 subjects. All subjects were men; the average age at the time of the injury was 38 years. Of these, 72% changed job/retired after the injury. The current entrance was the hand in 94% and grounding in the lower limb in 78%. The average burned surface area (BSA) was 8.6%. The handgrip strength of the injured limb was reduced (p < 0.05) and so also that of the three pinch types. The relationship between the handgrip strength and the DASH was statistically significant (p < 0.001) as well as the relationship between the three pinch types (p <= 0.02) to the injured limb. The ability to perceive cutaneous touch/pressure was decreased in the burnt hand, principally in the median nerve area. These data indicate a reduction of the hand muscular strength and sensibility, reducing the function of the upper limb in patients who received high-voltage electrical shock. (C) 2008 Elsevier Ltd and ISBI. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The prevention and treatment of diseases related to changes in body composition require accurate methods for the measurement of body composition. However, few studies have dealt specifically with the assessment of body composition of undernourished older subjects by different methodologies. To assess the body composition of undernourished older subjects by two different methods, dual energy x-ray absorptiometry (DXA) and bioelectric impedance (BIA), and to compare results with those of an eutrophic group. The study model was cross-sectional; the study was performed at the University Hospital of the School of Medicine of Ribeiro Preto, University of So Paulo, Brazil. Forty-one male volunteers aged 62 to 91 years. The groups were selected on the basis of anamnesis, physical examination and nutritional assessment according to the Mini Nutritional Assessment (MNA) score. Body composition was assessed by DXA and BIA. Body weight, arm and calf circumference, body mass index (BMI), fat free mass (FFM) and fat mass (FM) were significantly lower in the undernourished group as compared to the eutrophic group. There were no significant differences between FFM and FM mean values determined by DXA and BIA in both groups, but the agreement between methods in the undernourished group was less strong. Our results suggest caution when BIA is to be applied in studies including undernourished older subjects. This study does not support BIA as an accurate method for the individual assessment of body composition.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There seems to be controversy on the anorectal sphincter presentation and anatomical division, as well as on its functional representation. Evaluation of the anorectal sphincter musculature has been achieved through several methods, including anorectal manometry and computerized tomography, but to date there is no experimental model allowing a detailed manometric study of this muscle complex. In this work, we have developed such a model, which should enable the manometric and radiographic study of the anatomical features and functional mechanisms of sphincteric injuries, as well as the assessment of drug effects on the anorectal musculature upon incontinence and constipation. Twenty-two piglets (aged 25-30 days, weighing 5-7 kg) were studied by anorectal manometry (rectoanal inhibitory reflex and vector volume) and computerized tomography (anorectal angle and anal canal length). The data obtained for the rectoanal inhibitory reflex, represented here as the average and standard deviation, were the following: relaxation duration = 14.75 +/- 3.62 s, sphincter basal pressure = 41.58 +/- 8.20 mmHg, relaxation index = 87.26 +/- 11.52%, speed of relaxation = 5.90 +/- 2.10 mm/s, and speed of relaxation recovery = 4.03 +/- 1.78 mm/s. As for the vector volume, results were as follows: vector volume = 2692.32 +/- 1298.12 mmHg(2) cm, sphincter length = 11.82 +/- 2.74 mm, high pressure zone length = 5.09 +/- 1.34 mm, maximum pressure = 61.50 +/- 20.58 mmHg, and asymmetry index = 43.50 +/- 10.03%. Radiographic evaluation led to the following results: anal canal length = 9.61 +/- 2.14 mm and anorectal angle = 137.91 +/- 7.75 degrees. The experimental model designed here allows both anorectal manometry and computerized tomography to be carried out in the same way it is performed in human beings, as long as animal sedation is strictly controlled.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Fat accumulation in the upper region of the body is common in polycystic ovary syndrome (PCOS) and is associated with metabolic complications. The present study aimed to assess the relationship between trunk circumference, metabolic indicators, and abdominal and visceral fat in obese PCOS women. Methods: The weight, fat mass, and subcutaneous arm fat (SAF) of 30 obese PCOS women and 15 healthy controls matched for age and body mass index were evaluated by bioelectrical impedance analysis. Trunk (TrC), neck (NC) and hip circumferences were measured, and the trunk/hip (Tr/H) ratio was determined. Total abdominal fat (TAF), visceral fat (VF) and trunk fat (TrF) were determined by computed tomography. Biochemical evaluation included glycaemia, insulinaemia, testosterone and lipid profile, insulin resistance (IR) was assessed by the QUICKI index. Results: In the PCOS group, there were positive correlations between NC and TAF (r = 0.49, P < 0.0006), TrC and VF (r = 0.62, P = 0.01), and NC and VF (r = 0.70, P < 0.0002). There was good correlation between TrC and TrF (r = 0.69, P = 0.003). TrF correlated with triglycerides levels positively (r = 0.44, P = 0.02). Women with PCOS and IR had a larger quantity of VF and TrF, but a smaller amount of SAF. Within the PCOS group, women with Tr/H ratio above the median had higher basal insulin levels and lower QUICKI indices compared to women presenting a Tr/H ratio below the median. Conclusions: TrC is associated with important metabolic variables in PCOS, proving to be a valuable and innovative tool for assessment of body adiposity distribution in obese PCOS women.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tamoxifen has been suggested to produce beneficial cardiovascular effects, although the mechanisms for these effects are not fully known. Moreover, although tamoxifen metabolites may exhibit 30-100 times higher potency than the parent drug, no previous study has compared the effects produced by tamoxifen and its metabolites on vascular function. Here, we assessed the vascular responses to acetylcholine and sodium nitroprusside on perfused hindquarter vascular bed of rats treated with tamoxifen or its main metabolites (N-desmethyl-tamoxifen, 4-hydroxy-tamoxifen, and endoxifen) for 2 weeks. Plasma and whole-blood thiobarbituric acid reactive substances (TBARS) concentrations were determined using a fluorometric method. Plasma nitrite and NOx (nitrite + nitrate) concentrations were determined using an ozone-based chemiluminescence assay and Griess reaction, respectively. Treatment with tamoxifen reduced the responses to acetylcholine (pD(2) = 2.2 +/- 0.06 and 1.9 +/- 0.05 after vehicle and tamoxifen, respectively; P < 0.05), while its metabolites improved these responses (pD(2) = 2.5 +/- 0.04 after N-desmethyl-tamoxifen, 2.5 +/- 0.03 after 4-hydroxy-tamoxifen, and 2.6 +/- 0.08 after endoxifen; P < 0.01). Tamoxifen and its metabolites showed no effect on endothelial-independent responses to sodium nitroprusside (P > 0.05). While tamoxifen treatment resulted in significantly higher plasma and whole blood lipid peroxide levels (37% and 62%, respectively; both P < 0.05), its metabolites significantly decreased lipid peroxide levels (by approximately 50%; P < 0.05). While treatment with tamoxifen decreased the concentrations of markers of nitric oxide formation by approximately 50% (P < 0.05), tamoxifen metabolites had no effect on these parameters (P > 0.05). These results suggest that while tamoxifen produces detrimental effects, its metabolites produce counteracting beneficial effects on the vascular system and on nitric oxide/reactive oxygen species formation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: To compare the circulating levels of matrix metalloproteinase (MMP)-2, MMP-9, tissue inhibitors of metalloproteinase (TIMP)-1, TIMP-2, and the MMP-9/TIMP-1 and MMP-2/TIMP-2 ratios in preeclampsia and gestational hypertension with those found in normotensive pregnancies. Design and methods: We studied 83 pregnant women (30 healthy pregnant women with uncomplicated pregnancies, 26 with gestational hypertension, and 27 with preeclampsia) and 30 healthy nonpregnant women in a cross-sectional study. MMP and TIMP concentrations were measured in plasma samples by gelatin zymography and ELISA, respectively. Results: We found higher plasma pro-MMP-9 levels, and higher pro-MMP-9/TIMP-1 ratios in women with gestational hypertension (95%-CI: 1.031 to 2.357, and 0.012 to 0.031, respectively), but not with preeclampsia, compared with those found in normotensive pregnant women (95%-CI: 0.810 to 1.350, and 0.006 to 0.013, respectively; both P<0.05). We found no significant differences in pro-MMP-2 levels (P>0.05). Conclusions: The higher net MMP-9 (but not MMP-2) activity in gestational hypertension compared with normotensive pregnancy suggests that MMP-9 plays a role in the pathophysiology of gestational hypertension. Conversely, the lack of such alterations in preeclampsia is consistent with the notion that different pathophysiological mechanisms are involved in these hypertensive disorders. (C) 2008 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The frontal assessment battery (FAB) is a bedside cognitive scale designed to measure executive functions. Huntington`s disease (HD) is a neurodegenerative disorder characterized by motor, behavioral, and cognitive dysfunction. The aim of this study was to check the validity of the FAB for the evaluation of cognitive impairment in patients with HD. Forty-one patients diagnosed with HD and 53 healthy controls matched by education, sex and age were evaluated with a validated Brazilian version of the UHDRS, the VFT, the SDMT, the SIT, the MMSE, and the FAB. The diagnosis of HD was made by DNA analysis. FAB scores were lower in patients than in the controls (p < 0.001) and had significant correlations with the VFT (r = 0.79; p < 0.05), the SDMT (r = 0.80; p < 0.05), the SIT (r = 0.72; p < 0.05), the MMSE (r = 0.83; p < 0.05), the FCS (r = 0.79; p < 0.05) and the motor section of the UHDRS (r = -0.80; p < 0.05). The FAB differentiated between HD patients in the initial and later stages of the disease. The one-year longitudinal evaluation revealed a global trend toward a worsening in the second score of the FAB. The results demonstrate that the FAB presents good internal consistency and also convergent and discriminative validity; therefore it is a useful scale to assess executive functions and to evaluate cognitive impairment in patients with HD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background. Play is an indication of a children`s development. Purpose. Organize a culturally adapt the Child-Initiated Pretend Play Assessment to Brazilian population. Method. Translation and cultural adaptation procedures consisted of translation, synthesis, back translation, author`s approval, and pretest of the assessment. For the pretest, 14 typically developing children were assessed. Was evaluated the use of play materials, duration of the assessment, and reliability. Findings. Play materials and duration of the assessment were appropriate for Brazilian children. Analysis of intra-rater reliability showed good agreement ranging from 0.90 to 1.00. Inter-rater reliability showed good to moderate agreement for five items ranging from 0.76 to 0.59. Four items showed chance to poor agreement (rho = -0.13 to 0.50). Implications. Results of the pretest indicate the Brazilian version of the ChIPPA is potentially useful for Brazilian children. ChIPPA training in Portuguese in Brazil with play observation feedback is recommended to improve inter-rater reliability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The normalized electromyographic characteristics of masticatory muscles in patients with temporomandibular joint disorders (TMD) and healthy controls were compared. Thirty TMD patients (15 men, 15 women, mean age 23 years) with long lasting pain (more than 6 months), and 20 control subjects matched for sex and age were examined. All patients had arthrogenous TMD according to the Research Diagnostic Criteria for TMD (RDC/TMD). Surface electromyography of masseter and temporal muscles was performed during maximum teeth clenching either on cotton rolls or in intercuspal position. Standardized EMG indices and the median power frequency were obtained, and compared between the two groups and sexes using ANOVAs. During clenching, the TMD patients had larger asymmetry in their temporalis muscles, larger temporalis activity relative to masseter, and reduced mean power frequencies than the control subjects (p < 0.05, ANOVA). In both groups, the mean power frequencies of the temporalis muscles were larger than those of the masseter muscles (p < 0.001). No sex related differences, and no sex x group interactions were found. In conclusion, young adult patients with long lasting TMD have an increased and more asymmetric standardized activity of their temporalis anterior muscle, and reduced mean power frequencies, relative to healthy controls. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Osteoarthritis (OA) is the most frequent form of arthritis, with major implications for individual and public health care without effective treatment available. The field of joint imaging, and particularly magnetic resonance (MR) imaging, has evolved rapidly owing to technical advances and the application of these to the field of clinical research. Cartilage imaging certainly is at the forefront of these developments. In this review, the different aspects of OA imaging and cartilage assessment, with an emphasis on recent advances, will be presented. The current role of radiography, including advances in the technology for joint space width assessment, will be discussed. The development of various MR imaging techniques capable of facilitating assessment of cartilage morphology and the methods for evaluating the biochemical composition of cartilage will be presented. Advances in quantitative morphologic cartilage assessment and semiquantitative whole-organ assessment will be reviewed. Although MR imaging is the most important modality in imaging of OA and cartilage, others such as ultrasonography play a complementary role that will be discussed briefly.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Knee osteoarthritis (OA) has to be considered a whole joint disease. Magnetic resonance imaging (MRI) allows superior assessment of all joint tissues that may be involved in OA, such as the subchondral bone, synovium, ligaments, and periarticular soft tissues. Reliable MRI-based scoring systems are available to assess and quantify these structures and associated pathology. Cross-sectional and longitudinal evaluation has enabled practitioners to understand their relevance in explaining pain and structural progression.