143 resultados para Amplitude térmica
Masticatory muscle function three years after surgical correction of class III dentofacial deformity
Resumo:
Individuals with dentofacial deformities have masticatory muscle changes. The objective of the present study was to determine the effect of interdisciplinary treatment in patients with dentofacial deformities regarding electromyographic activity (EMG) of masticatory muscles three years after surgical correction. Thirteen patients with class III dentofacial deformities were studied, considered as group PI (before surgery) and group P3 (3 years to 3 years and 8 months after surgery). Fifteen individuals with no changes in facial morphology or dental occlusion were studied as controls. The participants underwent EMG examination of the temporal and masseter muscles during mastication and biting. Evaluation of the amplitude interval of EMG activity revealed a difference between P1 and P3 and no difference between P3 and the control group. In contrast, evaluation of root mean square revealed that, in general, P3 values were higher only when compared with PI and differed from the control group. There was an improvement in the EMG activity of the masticatory muscles, mainly observed in the masseter muscle, with values close to those of the control group in one of the analyses.
Resumo:
Background Chronic progressive external ophthalmoplegia is a mitochondrial myopathy that causes muscular or multisystem symptoms and has dysphagia as one manifestation. Aim To evaluate esophageal contractions in patients with chronic progressive external ophthalmoplegia. Methods We studied 14 patients with chronic progressive external ophthalmoplegia and 16 asymptomatic volunteers. The diagnosis of the disease was established by the clinical picture and by mitochondrial DNA analysis in skeletal muscle. We used the manometric method with a perfusion catheter that recorded the esophageal contractions at 2, 7, 12, 17, and 22 cm from the lower esophageal sphincter (LES). All subjects performed in the supine position 20 swallows of a 5-ml bolus of water at room temperature, ten every 30 s and ten every 10 s. Results The amplitude, duration, and area under the curve of contractions at 17 and 22 cm from the LES were lower in patients than in volunteers for swallows performed at 10-s and 30-s intervals (P < 0.01). There was no difference in contractions at 7 and 2 cm, except for the contractions at 2 cm after swallows performed at 30-s intervals. The interval between the onset of contractions between 7 and 2 cm and between 22 and 2 cm was lower in patients than in volunteers, with swallows performed every 10 s and every 30 s. Conclusions There is impairment of esophageal contractions in patients with chronic progressive external ophthalmoplegia, mainly in the proximal esophageal body.
Resumo:
We have previously isolated a Lys49 phospholipase A(2) homolog (BaTX) from Bothrops alternatus snake venom using a combination of molecular exclusion chromatography and reverse phase HPLC and shown its ability to cause neuromuscular blockade. In this work, we describe a one-step procedure for the purification of this toxin and provide further details of its neuromuscular activity. The toxin was purified by reverse phase HPLC and its purity and molecular mass were confirmed by SIDS-PAGE, MALDI-TOF mass spectrometry, amino acid analysis and N-terminal sequencing. BaTX (0.007-1.4 mu M) produced time-dependent, irreversible neuromuscular blockade in isolated mouse phrenic nerve-diaphragm and chick biventer cervicis preparations (time to 50% blockade with 0.35 mu M toxin: 58 +/- 4 and 24 +/- 1 min, respectively; n = 3-8; mean +/- S.E.) without significantly affecting the response to direct muscle stimulation. In chick preparations, contractures to exogenous acetylcholine (55 and 110 mu M) or KCl (13.4 mM) were unaltered after complete blockade by all toxin concentrations. These results, which strongly suggested a presynaptic mechanism of action for this toxin, were reinforced by (1) the inability of BaTX to interfere with the carbachol-induced depolarization of the resting membrane, (2) a significant decrease in the frequency and amplitude of miniature end-plate potentials, and (3) a significant reduction (59 +/- 4%, n=12) in the quantal content of the end-plate potentials after a 60 min incubation with the toxin (1.4 mu M). In addition, a decrease in the organ bath temperature from 37 degrees C to 24 degrees C and/or the replacement of calcium with strontium prevented the neuromuscular blockade, indicating a temperature-dependent effect possibly mediated by enzymatic activity. (C) 2009 Elsevier Inc. All rights reserved.
Resumo:
Production and secretion of testosterone in Leydig cells are mainly controlled by the luteinizing hormone (LH). Biochemical evidences suggest that the activity of Cl(-) ions can modulate the steroidogenic process, but the specific ion channels involved are not known. Here, we extend the characterization of Cl(-) channels in mice Leydig cells (50-60 days old) by describing volume- activated Cl(-) currents (I(Cl,swell)). The amplitude of I(Cl,swell) is dependent on the osmotic gradient across the cell membrane, with an apparent EC(50) of similar to 75 mOsm. These currents display the typical biophysical signature of volume- activated anion channels (VRAC): dependence on intracellular ATP, outward rectification, inactivation at positive potentials, and selectivity sequence (I(-)>Cl(-)>F(-)). Staurosporine (200 nM) did not block the activation of I(Cl), swell. The block induced by 5-nitro-2-(3-phenylpropylamino) benzoic acid (NPPB; 128 mu M), SITS (200 mu M), ATP (500 mu M), pyridoxalphosphate-6- azophenyl-2`,4`-disulfonate (PPADS; 100 mu M), and Suramin (10 mu M) were described by the permeant blocker model with apparent dissociation constant at 0 mV K(d)(0) and fractional distance of the binding site (delta) of 334 mu M and 47%, 880 mu M and 35%, 2,100 mu M and 49%, 188 mu M and 27%, and 66.5 mu M and 49%, respectively. These numbers were derived from the peak value of the currents. We conclude that ICl, swell in Leydig cells are activated independently of purinergic stimulation, that Suramin and PPADS block these currents by a direct interaction with VRAC and that ATP is able to permeate this channel.
Resumo:
In vitro, nitric oxide (NO) inhibits the firing rate of magnocellular neurosecretory cells (MNCs) of hypothalamic supraoptic and paraventricular nuclei and this effect has been attributed to GABAergic activation. However, little is known about the direct effects of NO in MNCs. We used the patch-clamp technique to verify the effect Of L-arginine, a precursor for NO synthesis, and N-omega-nitro-L-arginine methyl ester hydrochloride (L-NAME), an inhibitor of NOS, on spontaneous electrical activity of MNCs after glutamatergic and GABAergic blockade in Wistar rat brain slices. 6-Cyano-7-nitroquinoxaline-2,3-dione (CNQX) (10 mu M) and DL-2-amino-5-phosphonovaleric acid (DL-AP5) (30 mu M) were used to block postsynaptic glutamatergic currents, and picrotoxin (30 mu M) and saclofen (30 mu M) to block ionotropic and metabotropic postsynaptic GABAergic currents. Under these conditions, 500 mu M L-arginine decreased the firing rate from 3.7 +/- 0.6 Hz to 1.3 +/- 0.3 Hz. Conversely, 100 mu M L-NAME increased the firing rate from 3.0 +/- 0.3 Hz to 5.8 +/- 0.4 Hz. All points histogram analysis showed changes in resting potential from -58.1 +/- 0.8 mV to -62.2 +/- 1.1 mV in the presence of L-arginine and from -59.8 +/- 0.7 mV to -56.9 +/- 0.8 mV by L-NAME. Despite the nitrergic modulator effect on firing rate, some MNCs had no significant changes in their resting potential. In those neurons, hyperpolarizing after-potential (HAP) amplitude increased from 12.4 +/- 1.2 mV to 16.8 +/- 0.7 mV by L-arginine, but without significant changes by L-NAME treatment. To our knowledge, this is the first demonstration that NO can inhibit MNCs independent of GABAergic inputs. Further, our results point to HAP as a potential site for nitrergic modulation. (C) 2008 IBRO. Published by Elsevier Ltd. All rights reserved.
Resumo:
Objectives: The objective of the present study was to evaluate intraluminal esophageal pressure during voice and speech emission in speaking laryngectomees with a tracheoesophageal prosthesis. Methods: In our prospective analysis in a tertiary-care academic hospital, 25 laryngectomees were divided into 2 groups: 11 speaking individuals with a tracheoesophageal prosthesis and a control group of 14 nonspeaking laryngectomees. All patients were subjected to manometry during voice and speech emission tests. We determined the pressures achieved in the distal, middle, and proximal parts of the esophagus. Results: Statistical analysis revealed that the amplitude of pressure in the distal esophagus during sound emission was higher in speaking laryngectomees; in the middle esophagus, intraluminal pressure during emission of the sentence was higher in speaking subjects, and in the proximal esophagus there was no difference between the groups. Conclusions: During the manometric evaluation of the distal and middle esophagus in the presence of voice and speech emission, the intraluminal pressure revealed a significant difference for the speaking laryngectomees with a tracheoesophageal prosthesis. The proximal esophagus behaved similarly in the groups of speakers and nonspeakers. Speaking laryngectomees with a tracheoesophageal prosthesis depend on a differentiated performance of the middle and distal parts of the esophagus.
Resumo:
Purpose: Contact lens electrodes (CLEs) are frequently used to register electroretinograms (ERGs) in small animals such as mice or rats. CLEs are expensive to buy or difficult to be produced individually. In addition, CLE`s have been noticed to elicit inconstant results and they carry potential to injure the cornea. Therefore, a new electrode holder was constructed based on the clinically used DTL-electrode and compared to CLEs. Material and methods: ERGs were recorded with both electrode types in nine healthy Brown-Norway rats under scotopic conditions. For low intensity responses a Naka-Rushton function was fitted and the parameters V(max), k and n were analyzed. The a-wave, b-wave and oscillatory potentials were analyzed for brighter flash intensities (1-60 scot cd s/m(2)). Repeatability was assessed for both electrode types in consecutive measurements. Results: The new electrode holder was faster in setting up than the CLE and showed lower standard deviations. No corneal alterations were observed. Slightly higher amplitudes were recorded in most of the measurements with the new electrode holder (except amplitudes induced by 60 cd s/m(2)). A Bland-Altman test showed good agreement between the DTL holder and the CLE (mean difference 35.2 mu V (Holder-CLE)). Pearson`s correlation coefficient for test-retest-reliability was r = 0.783. Conclusions: The DTL holder was superior in handling and caused far less corneal problems than the CLE and produced comparable or better electrophysiological results. The minimal production costs and the possibility of adapting the DTL holder to bigger eyes, such as for dogs or rabbits, offers with broader application prospects. (C) 2010 Elsevier B.V. All rights reserved.
Resumo:
Objective: Clinical evaluation of the stomatognathic system is indispensable for the diagnosis of orofacial myofunctional disorders. In order to obtain a more precise diagnosis, the protocol of orofacial myofunctional evaluation with scores (OMES protocol) (Int. J. Pediatr. Otorhinolaryngol. 72 (2008) 367-375) was expanded in terms of number of items and scale amplitude. The proposal of this study is to describe the expanded OMES protocol (OMES-E) for the evaluation of children. Validity of the protocol, reliability of the examiners and agreement between them were analyzed, as also were the sensitivity, specificity and predictive values of the instrument. Methods: The sample consisted of videorecorded images of 50 children, 25 boys (mean age = 8.4 years, SD = 1.8) and 25 girls (mean age = 8.2 years, SD = 1.7) selected at random from 200 samples. Three speech therapists prepared for orofacial myofunctional evaluation participated as examiners (E). The OMES and OMES-E protocols were used for evaluation on different days. E1 evaluated all images, E2 analyzed children with recordings from 1 to 25 and E3 analyzed children with recordings from 26 to 50. The validity of OMES-E was analyzed by comparing the instrument to the OMES protocol using the Pearson correlation test complemented with the split-half reliability test (p < 0.05). The linear weighted Kappa coefficient of agreement (Kw`), the sensitivity, specificity and predictive values and the prevalence of OMD were calculated. Results: There was a statistically significant correlation between the OMES and OMES-E protocols (0.79 > r < 0.94, p < 0.01) and a significant test-retest correlation with the OMES-E (0.75 > r < 0.86, p < 0.01), with a reliability range of 0.86-0.93. The correlation and reliability coefficients between examiners were: E1 x E2 (r = 0.74, 0.84), E1 x E3 (r = 0.70, 0.83) (p < 0.01). Kw` coefficients with moderate and good strength predominated. The OMES-E protocol presented mean sensitivity = 0.91, specificity = 0.77, positive predictive value = 0.87 and negative predictive value = 0.85. The mean prevalence of OMD was 0.58. Conclusion: The OMES-E protocol is valid and reliable for orofacial myofunctional evaluation. (C) 2010 Elsevier Ireland Ltd. All rights reserved.
Resumo:
To test a mathematical model for measuring blinking kinematics. Spontaneous and reflex blinks of 23 healthy subjects were recorded with two different temporal resolutions. A magnetic search coil was used to record 77 blinks sampled at 200 Hz and 2 kHz in 13 subjects. A video system with low temporal resolution (30 Hz) was employed to register 60 blinks of 10 other subjects. The experimental data points were fitted with a model that assumes that the upper eyelid movement can be divided into two parts: an impulsive accelerated motion followed by a damped harmonic oscillation. All spontaneous and reflex blinks, including those recorded with low resolution, were well fitted by the model with a median coefficient of determination of 0.990. No significant difference was observed when the parameters of the blinks were estimated with the under-damped or critically damped solutions of the harmonic oscillator. On the other hand, the over-damped solution was not applicable to fit any movement. There was good agreement between the model and numerical estimation of the amplitude but not of maximum velocity. Spontaneous and reflex blinks can be mathematically described as consisting of two different phases. The down-phase is mainly an accelerated movement followed by a short time that represents the initial part of the damped harmonic oscillation. The latter is entirely responsible for the up-phase of the movement. Depending on the instantaneous characteristics of each movement, the under-damped or critically damped oscillation is better suited to describe the second phase of the blink. (C) 2010 Elsevier B.V. All rights reserved.
Resumo:
Purpose: To describe spontaneous blink kinematics in Graves` upper eyelid retraction (UER). Methods: The magnetic search coil technique was used to record spontaneous blinks of 15 healthy subjects (aged 23-56 years, 15 eyelids) and 15 patients with Graves` UER (aged 22-62 years, 15 eyelids) during a 5-min period of video observation, and the signals were digitized at 200 Hz (12 bits). Overall, a total of 2,798 blinks were recorded for the controls and 1,860 for the patients. The distance between pupil center and upper eyelid margin in the primary position of gaze (MRD) was measured with the Image J software. Results: The blinking rate of patients was lower than that of control subjects, with a mean (+/-SEM) blinking rate (blinks/min) of 13.0 +/- 1.7 for patients and of 20.0 +/- 2.1 for the controls (t = 2.58, P = 0.016). There were no statistically significant differences in blink amplitude between controls (22.7 +/- 3.1 degrees) and Graves` patients (24.7 +/- 3.3 degrees). However, while only 22% of the blinks performed by controls were smaller than MRD, this rate was 78% for patients. In addition, in blinks larger than 25, patients showed lower down-phase velocity than controls. Conclusions: Patients with Graves` UER show reduced blinks rates and abnormal blink kinematics, which might be related to the development of exposure keratitis in this disease.
Resumo:
Introduction: Zinc is an essential element for human homeostasis being clearly related to almost all metabolic pathways. It is found in some neural circuitries, probably acting as a modulator of glutamatergic excitatory synapsis. In the auditory system its presence has been demonstrated within the cochlea and cochlear nuclei. Tinnitus symptoms are correlated to zinc physiology, and it has been postulated that the oligoelement could be used as an alternative treatment for this clinical situation. Aim: This study has evaluated the brainstem responses (ABR) in patients who suffer from chronic idiophatic tinnitus, before and after being treated with zinc. Neural transmissions in the brainstem auditory structures were also compared in both conditions. Materials and Methods: Forty-one patients (22 with tinnitus and 19 controls, groups I and II, respectively) were included in the study and submitted to anamnesis, otorhinolaryngologic examinations, biochemical evaluation and audiological tests. Group I patients received an specific zinc formulation for 90 days. ABR tests were performed at the beginning of the study and at the end of the zinc treatment. Results: First ABR tests showed no differences between the groups, but on the second evaluation there was a significant prolongation of the wave V latency and an enlargement of wave V amplitude shown in group I. Conclusion: Treatment with systemic zinc could change some aspects of auditory neurotransmission in the brainstem.
Resumo:
Objectives: To determine the differences between tympanic and extratympanic electrodes regarding recording technique, comfort and ease of execution of the exam, and quality of auditory potential tracings. Study Design: Prospective cross-section investigation. Methods: Determination of the summation potential/action potential (SP/AP) ratio by electrocochleography (EchoG) using tympanic and extratympanic electrodes and separate analysis of SP and AP regarding the amplitude recorded. Results: Twenty-three subjects (15 men and 8 women; mean age: 33.17 years) with normal tonal threshold audiometry were evaluated. EchoG analysis revealed no significant difference between the two tympanic electrodes. Eleven of the 23 subjects reported discomfort with the insertion of the tympanic electrode even with the use of topical xylocaine, whereas no complaints of discomfort were reported with the use of the extratympanic electrode. Conclusions: Both electrodes were effective for EchoG evaluation, but the extratympanic one was easier to insert and did not cause discomfort. However, the tympanic electrode produced tracings of greater amplitude and of better reproducibility. Laryngoscope, 119:563-566, 2009
Resumo:
PURPOSE. To establish the relationship between upper eyelid saccades and upper eyelid pursuit movements. METHODS. Upper eyelid saccades and periodic sinusoidal upper eyelid pursuit movements were recorded in a sample of controls and patients with Graves upper eyelid retraction. A video-computerized system was used to register both types of movements that accompanied 60 of eye rotation across the upper and lower hemifields. The forced harmonic oscillator model was used to fit saccadic and pursuit movements. RESULTS. Mean mid-pupil eyelid distance for the Graves patients (6.6 +/- 1.1 mm) was significantly higher than for the controls (4.6 +/- 0.8 mm; t = 7.18; P < 0.00001). Despite the difference in the upper eyelid resting position, saccades and pursuit eyelid movements of both groups were extremely well fitted by underdamped solutions and steady forced solutions of the harmonic oscillator model, respectively. For the controls, the amplitude of the pursuit movements was well correlated with the upward and downward saccades. The amplitude of the eyelid movements of the Graves patients (saccades and pursuit) was significantly reduced compared with that of the controls. CONCLUSIONS. Saccadic and pursuit movements of the upper eyelid can be described by the harmonic oscillator model. In healthy subjects and Graves patients, the amplitude of pursuit lid movements is correlated to the saccade amplitude. Pursuit eyelid movements are more difficult to register than saccades, and their measurements do not allow clear separation of the relaxation and contraction properties of the upper eyelid retractors.
Resumo:
PURPOSE. To assess the safety of transcorneal electrical stimulation (TES) and explore its efficacy in various subjective and objective parameters of visual function in patients with retinitis pigmentosa (RP). METHODS. Twenty-four patients in this prospective, randomized, partially blinded, good-clinical-practice study underwent TES (5-ms biphasic pulses; 20 Hz; DTL electrodes) 30 minutes per week for 6 consecutive weeks. The patients were randomly assigned to one of three groups: sham, 66%, or 150% of individual electrical phosphene threshold (EPT). Visual acuity (VA), visual field (VF; kinetic, static), electroretinography (Ganzfeld, multifocal), dark-adaptation (DA), color discrimination, and EPTs were assessed at all visits or four times, according to the study plan. RESULTS. TES using DTL electrodes was tolerated well; all patients finished the study. Two adverse (foreign body sensation), but no serious adverse events were encountered. There was a tendency for most functional parameters to improve (8/18) or to remain constant (8/18) in the 150% group. VF area and scotopic b-wave amplitude reached statistical significance (P < 0.027 and P < 0.001, respectively). Only desaturated color discrimination and VF mean sensitivity decreased. There was no obvious trend in the 66% group. CONCLUSIONS. TES was found to be safe in RP patients. Positive trends were discovered, but due to the small sample size of this exploratory study, statistical significance was reached only for VF area and scotopic b-wave amplitude. Further studies with larger sample sizes and longer duration are needed to confirm the findings and to define optimal stimulation parameters. (ClinicalTrials.gov number, NCT00804102.) (Invest Ophthalmol Vis Sci. 2011;52:4485-4496) DOI:10.1167/iovs.10-6932
Resumo:
Purpose: To evaluate the short-term (10 months) safety of a single intravitreal injection of autologous bone marrow-derived mononuclear cells in patients with retinitis pigmentosa or cone-rod dystrophy. Methods: A prospective, Phase I, nonrandomized, open-label study including 3 patients with retinitis pigmentosa and 2 patients with cone-rod dystrophy and an Early Treatment Diabetic Retinopathy Study best-corrected visual acuity of 20/200 or worse. Evaluations including best-corrected visual acuity, full-field electroretinography, kinetic visual field (Goldman), fluorescein and indocyanine green angiography, and optical coherence tomography were performed at baseline and 1, 7, 13, 18, 22, and 40 weeks after intravitreal injection of 10 X 10(6) autologous bone marrow-derived mononuclear cells (0.1 mL) into 1 study eye of each patient. Results: No adverse event associated with the injection was observed. A 1-line improvement in best-corrected visual acuity was measured in 4 patients 1 week after injection and was maintained throughout follow-up. Three patients showed undetectable electroretinography responses at all study visits, while 1 patient demonstrated residual responses for dark-adapted standard flash stimulus (a wave amplitude approximately 35 mu V), which remained recordable throughout follow-up, and 1 patient showed a small response (a wave amplitude approximately 20 mu V) recordable only at Weeks 7, 13, 22, and 40. Visual fields showed no reduction (with a Goldman Standard V5e stimulus) for any patient at any visit. No other changes were observed on optical coherence tomography or fluorescein and indocyanine green angiograms. Conclusion: Intravitreal injection of autologous bone marrow-derived mononuclear cells in eyes with advanced retinitis pigmentosa or cone-rod dystrophy was associated with no detectable structural or functional toxicity over a period of 10 months. Further studies are required to investigate the role, if any, of autologous bone marrow-derived mononuclear cell therapy in the management of retinal dystrophies. RETINA 31: 1207-1214, 2011