149 resultados para dental caries risk tests


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Osteonecrosis of the jaw (ONJ), previously an entity associated with radiation therapy to the head and neck, has been observed in patients treated with bisphosphonates. Patients with metastatic breast cancer and myelomatous bone disease, commonly treated with high-potency nitrogen-containing bisphosphonates for a prolonged period of time, have the greatest risk of ONJ development. The reported frequency of ONJ ranges from 0.6% to 6.2% in breast cancer and from 1.7% to 15% in patients with multiple myeloma. Osteonecrosis of the jaw has also been observed in patients with other cancers such as prostate cancer and in benign bone disorders such as osteoporosis and Paget`s disease in which the incidence is low. Risk factors associated with the development of ONJ include dental extractions, length of bisphosphonate treatment, and the type of bisphosphonate used. In this review, we summarize the reported incidence and risk factors associated with ONJ.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose of review This review discusses ovarian reserve tests for ovulation induction and their application in determining fertility capacity, and their current applications to assess risk of natural ovarian failure and to estimate ovarian function after cancer treatment. Recent findings The current arsenal of ovarian reserve tests comprises hormonal markers [basal follicle stimulating hormone, estradiol, inhibin-B, antimullerian hormone (AMH)] and ultrasonographic markers [ovarian volume, antral follicle counts (AFCs)]. These markers have limitations in terms of which test(s) should be used to reliably predict ovarian reserve with regard to accuracy, invasiveness, cost, convenience, and utility. Several studies have correlated sonographic AFCs with serum AMH levels for predicting the ovarian response to ovulation induction protocols during assisted reproduction treatments. Summary Serum AMH levels and AFC are reliable tests for predicting the ovarian response to ovulation induction. However, none of the currently employed tests of ovarian reserve can reliably predict pregnancy after assisted conception. Further, ovarian reserve tests cannot predict the onset of reproductive and hormonal menopause; thus, they should be used with caution for reproductive life-programming counseling. Moreover, there is no evidence to support the use of ovarian reserve tests to estimate the risk of ovarian sufficiency after cancer treatments.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Kabuki syndrome is a genetic disorder of unknown etiology characterized by mental retardation, growth deficiency, and peculiar face (i.e., long palpebral fissures, eversion of the lateral third of the lower eyelids, prominent ears, and broad and depressed nasal tip). Oral manifestations commonly observed in Kabuki syndrome may comprise cleft lip/palate, bifid tongue and uvula, malocclusion, and dental abnormalities. We evaluated the dental findings of eight patients with Kabuki syndrome. One presented cleft palate; three presented caries; and seven had missing teeth, with the upper lateral incisors and inferior central incisors being the most commonly absent. All missing teeth were permanent, and there was no alteration of dental chronology or morphology. Because most patients had mixed dentition, the presence or absence of primary teeth was assessed through the parents` reports. One patient presented an absent upper canine, which had not been reported previously in the literature. Dental findings may be helpful for clinical diagnosis, or they may be an additional finding to substantiate the diagnosis of Kabuki syndrome in children with mild phenotype.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: The purpose of the study was to investigate whether dentine irradiation with a pulsed CO(2) laser (10.6 mu m) emitting pulses of 10 ms is capable of reducing dentine calcium and phosphorus losses in an artificial caries model. Design: The 90 dentine slabs obtained from bovine teeth were randomly divided into six groups (n = 15): negative control group (GC); positive control group, treated with fluoride 1.23% (GF); and laser groups irradiated with 8 J/cm(2) (L8); irradiated as in L8 + fluoride 1.23% (L8F); irradiated with 11j/cm(2) (L11); irradiated as in L11 + fluoride 1.23% (L11F). After laser irradiation the samples were submitted to a pH-cycling model for 9 days. The calcium and phosphorous contents in the de- and remineralization solutions were measured by means of inductively coupled plasma optical emission spectrometer - ICP-OES. Additionally intra-pulpal temperature measurements were performed. The obtained data were analysed by means of ANOVA and Tukey`s test (alpha = 0.05). Results: In the demineralization solutions the groups L11F and GF presented significantly lower means of calcium and phosphorous losses than the control group; and in L11F means were significantly lower than in the fluoride group. Both irradiation parameters tested caused intrapulpal temperature increase below 2 degrees C. Conclusion: It can be concluded that under the conditions of this study, CO(2) laser irradiation (10.6 mu m) with 11J/cm(2) (540 mJ and 10 Hz) of fluoride treated dentine surfaces decreases the loss of calcium and phosphorous in the demineralization process and does not cause excessive temperature increase inside the pulp chamber. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: Stem cells are characterized by the ability to renew themselves through mitotic cell division and differentiating into a diverse range of specialized cell types. An important source of adult stem cells is the dental pulp. In dentistry, regenerative strategies are of importance because of hard dental tissue damage especially as result of caries lesions, trauma, or iatrogenic procedures. The regeneration of dental tissues relies on the ability of stem cells to produce extracellular (ECM) proteins encountered in the dental pulp tissue. Thus, the aim of this study was to analyze the expression and distribution of proteins encountered in dental pulp ECM (type I collagen, fibronectin, and tenascin) in stem cells. Methods: Human immature dental pulp stem cells (hIDPSCs) from deciduous (DL-1 and DL-4 cell lines) and permanent (DL-2) teeth were used. The distribution of ECM proteins was observed using the immunofluorescence technique. The gene expression profile was evaluated using reverse transcription polymerase chain reaction (RT-PCR) analysis. Results: Positive reactions for all ECM proteins were observed independently of the hIDPSCs analyzed. Type I collagen appeared less evident in DL-2 than in other hIDPSCs. Fibronectin and tenascin were less clear in DL-4. The RT-PCR reactions showed that type I collagen was lesser expressed in the DL-2 cells, whereas fibronectin and tenascin were similarly expressed in all hIDPSCs. Conclusions: The distribution and expression of ECM proteins differ among the hIDPSCs. These differences seemed to be related to the donor tooth conditions (deciduous or permanent, retained or erupted, and degree of root reabsorption). (J Endod 2010;36:826-831)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To assess the effects of three different dental adhesive systems on the formation of secondary root caries, in vitro, with a standardized interfacial gap in a filled cavity model. Methods: 40 sound human molars were selected and randomly assigned to four experimental groups: Clearfil SE Bond (CSEB), Xeno III (X-III), Scotchbond Multi-Purpose Plus (SBMP) and negative control (NC) without an adhesive system. After the standardized Class V cavity preparations on the buccal and lingual surfaces, restorations were placed with resin composite (Filtek Z250) using a standardized interfacial gap, using a 3 x 2 mm piece of 50 mu m metal matrix. The teeth were sterilized with gamma irradiation and exposed to a cariogenic challenge using a bacterial system with Streptococcus mutans. Depth and extension of wall lesions formed and the depth of outer lesions were measured by software coupled with light microscopy. Results: For wall lesion extension the ANOVA test showed differences between groups except between X-HI and SBMP (P= 0.294). The Tukey`s test of confidence intervals indicated smaller values for the CSEB group than for the others. For wall lesion depth the CSEB group also presented the smallest mean values of wall lesion depth when compared to the others (P< 0.0001) for all comparisons using Tukey`s test. Regarding outer lesion depth, all adhesives showed statistically similar behavior. SEM evaluation of the morphologic appearance of caries lesions confirmed the statistical results showing small caries lesion development for cavities restored with CSEB adhesive system, which may suggest that this adhesive system interdiffusion zone promoted a good interaction with subjacent dentin protecting the dental tissues from recurrent caries. (Am J Dent 2010;23:93-97).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study evaluated the effect of different parameters of erbium, chromium:yttrium-scandium-gallium-garnet (Er,Cr:YSGG) laser irradiation on enamel mineral loss in a simulated caries model. Forty-five enamel samples obtained from third molar teeth (3 mmx 3 mm) were randomly divided into five groups (n = 9): G1-Er,Cr:YSGG laser at 0.25 W, 20 Hz, 2.8 J/cm(2); G2-Er,Cr:YSGG laser at 0.50 W, 20 Hz, 5.7 J/cm(2); G3-Er,Cr:YSGG laser at 0.75 W, 20 Hz, 8.5 J/cm(2); G4-sodium fluoride (NaF) dentifrice (positive control); G5-no treatment (negative control). After irradiation, the samples were submitted to 2 weeks of pH cycling. After the acid challenge, the samples were assessed by cross-sectional microhardness at different depths from the enamel surface. Analysis of variance (ANOVA) and Student-Newman-Keuls tests were performed (alpha = 5%). The percentage of lesion inhibition for each group was: G1 37%; G2 38%; G3 64%, and G4 50.5%. Regarding the relative mineral loss values (micrometers x volume percent), groups G1 (1,392 +/- 522) and G2 (1,292 +/- 657) did not differ significantly from each other, but both had higher values than group G3 (753 +/- 287); the groups irradiated with Er,Cr:YSGG laser did not differ from group G4. Although the findings of the study revealed that Er,Cr:YSGG laser irradiation at 8.5 J/cm(2) can be an alternative for the enhancement of the enamel`s resistance to acid, lower energy densities also produced a cariostatic potential comparable to the use of fluoride dentifrice.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Although the cariostatic effects of CO(2) laser on enamel have been shown, its effects on root surface demineralization remains uncertain. The objectives of this in vitro research was to establish safe parameters for a pulsed 10.6 mu m CO(2) laser and to evaluate its effect on morphological features of the root surface, as well as on the reduction of root demineralization. Ninety-five human root surfaces were randomly divided into five groups: G1-No treatment (control); G2-2.5 J/cm(2); G3-4.0 J/cm(2); G4-5.0 J/cm(2); and G5-6.0 J/cm(2). Intrapulpal temperature was evaluated during root surface irradiation by a thermocouple and morphological changes were evaluated by SEM. After the surface treatment, the specimens were submitted to a 7-day pH-cycling model. Subsequently, the cross-sectional Knoop microhardness values were measured. For all irradiated groups, intrapulpal temperature changes were less than 1.5 degrees C. Scanning electron microscopy images indicated that fluences as low as 4.0 J/cm(2) were sufficient to induce morphological changes in the root surface. Additionally, for fluences reaching or exceeding 4.0 J/cm(2), laser-induced inhibitory effects on root surface demineralization were observed. It was concluded that laser energy density in the range of 4.0 to 6.0 J/cm(2) could be applied to a dental root to reduce demineralization of this surface without compromising pulp vitality.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: This study evaluated mechanical properties of glass ionomer cements (GICs) used for atraumatic restorative treatment. Wear resistance, Knoop hardness (Kh), flexural (F(s)) and compressive strength (C(s)) were evaluated. The GICs used were Riva Self Cure (RVA), Fuji IX (FIX), Hi Dense (HD), Vitro Molar (VM), Maxxion R (MXR) and Ketac Molar Easymix (KME). Methods: Wear was evaluated after 1, 4, 63 and 365 days. Two-way ANOVA and Tukey post hoc tests (P = 0.05) analysed differences in wear of the GICs and the time effect. F(s), C(s), and Kh were analysed with one-way ANOVA. Results: The type of cement (p < 0.001) and the time (p < 0.001) had a significant effect on wear. In early-term wear and Kh, KME and FIX presented the best performance. In long-term wear, F(s) and C(s), KME, FIX and HD had the best performance. Strong explanatory power between F(s) and the Kh (r(2) = 0.85), C(s) and the Kh (r(2) = 0.82), long-term wear and F(s) of 24 h (r(2) = 0.79) were observed. Conclusions: The data suggested that KME and FIX presented the best in vitro performance. HD showed good results except for early-term wear.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: The aim of this study was to detect the influence of (1) storage period of heparinized blood, (2) type of blood and presence of contaminant, (3) application mode of cleansing agents, and (4) efficacy of cleansing agents on contaminated enamel and dentin during the adhesion process of a one-step adhesive system. Materials and Methods: One hundred four human molars were sectioned into halves along the long axis for enamel and dentin tests. Heparinized and fresh blood were obtained from the same donor, applied and dried to maintain a layer of dry blood on the top of samples. The cleansing agents used were hydrogen peroxide, anionic detergent, and antiseptic solution. A one-step adhesive system (Clearfil S3 Bond) was applied on the dental surface, and composite resin cylinders were built up using Tygon tubing molds. After 24 h, the mu SBS test (1 mm/min) and fracture analysis were performed. Results: There was no statistically significant difference in bond strength values regarding the storage period of heparinized blood and the types of blood. Groups without contamination presented higher bond strengths than contaminated groups. The application mode of the cleansing agents had no influence on bond strength results. There was no statistically significant difference among cleansing agents and they were as effective as a water stream in counteracting the effect of blood contamination. Conclusion: Heparinized blood can be used as a contaminant for up to one week, and it is a reliable procedure to standardize the contaminant. The cleansing agents can be used without friction. A water stream is sufficient to remove blood contamination from dental tissues, before the application of a one-step adhesive system.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: The aim of this study was to evaluate the cardiovascular effects of maxillary infiltration using 2% lidocaine with 1: 100 000 adrenaline, 4% articaine with 1: 200 000 adrenaline, and 4% articaine with 1: 100 000 adrenaline in different stages during restorative dental procedures. Methods: Twenty healthy patients randomly received 1.8 mL of the three local anaesthetics. Systolic blood pressure, average blood pressure, diastolic blood pressure, and heart rate were evaluated by the oscillometric and photoplethysmograph methods in seven stages during the appointment. Results: Statistical analysis by ANOVA and Tukey tests of cardiovascular parameters did not show significant differences between the anaesthetic associations. There were significant differences for the parameters among different clinical stages. Conclusions: The variation of cardiovascular parameters was similar for lidocaine and articaine with both adrenaline concentrations and showed no advantage of one drug over the other. Cardiovascular parameters were influenced by the stages of the dental procedures, which showed the effect of anxiety during restorative dental treatment.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: The aim of this study was to assess the prevalence, extent, and severity of probing depth (PD) and to investigate the associations between demographic, socioeconomic, and behavioral risk indicators and PD in a periodontally untreated and isolated population in Brazil. Methods: The target population consisted of all individuals aged >= 12 years as identified by a census. Consenting participants were submitted to a full-mouth clinical examination of six sites per tooth and were interviewed using a structured written questionnaire. Results: Among the 214 subjects who were interviewed and clinically examined, PD >= 4 mm was observed in 54% to 83% of the subjects, depending on age, whereas the age-dependent prevalence of PD :6 mm ranged from 5% among 12- to 19-year-olds to 50% among 40- to 49-year-olds, decreasing to 40% among subjects >= 50 years of age. Multivariate analyses identified supragingival calculus (odds ratio [OR] = 5.4 to 10.3; 95% confidence intervals [CIs]: 2.5 to 11.6 and 4.0 to 26.2 for 20% to 50% and > 50% of the sites, respectively) as a risk indicator for PD A mm, whereas age :40 years (OR = 9.0; 95% CI: 1.7 to 48.5), being a moderate/heavy smoker (OR = 3.7; 95% CI: 1.4 to 10. 1), and having supragingival calculus in 20% to 50% of sites (OR = 6.8; 95% CI: 1.4 to 32.4) or in >50% of sites (OR = 15.3; 95% CI: 3.2 to 73.6) were risk indicators for PD >= 6 mm. Having undergone urgency dental treatment was a protective factor for PD A and >= 6 mm (OR = 0.4; 95% CI: 0.2 to 0.8). Conclusions: Increased PD is highly prevalent in this isolated population. Behavioral factors played a significant role as risk indicators for increased PD in this isolated population.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The literature shows contradictory results regarding the role of composite shrinkage and elastic modulus as determinants of polymerization stress. The present study aimed at a better understanding of the test mechanics that could explain such divergences among studies. The hypothesis was that the effects of composite shrinkage and elastic modulus on stress depend upon the compliance of the testing system. A commonly used test apparatus was simulated by finite element analysis, with different compliance levels defined by the bonding substrate (steel, glass, composite, or acrylic). Composites with moduli between 1 and 12 GPa and shrinkage values between 0.5% and 6% were modeled. Shrinkage was simulated by thermal analogy. The hypothesis was confirmed. When shrinkage and modulus increased simultaneously, stress increased regardless of the substrate. However, if shrinkage and modulus were inversely related, their magnitudes and interaction with rod material determined the stress response.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective. The goal of this paper is to undertake a literature search collecting all dentin bond strength data obtained for six adhesives with four tests ( shear, microshear, tensile and microtensile) and to critically analyze the results with respect to average bond strength, coefficient of variation, mode of failure and product ranking. Method. A PubMed search was carried out for the years between 1998 and 2009 identifying publications on bond strength measurements of resin composite to dentin using four tests: shear, tensile, microshear and microtensile. The six adhesive resins were selected covering three step systems ( OptiBond FL, Scotch Bond Multi-Purpose Plus), two-step (Prime & Bond NT, Single Bond, Clear. l SE Bond) and one step (Adper Prompt L Pop). Results. Pooling results from 147 references showed an ongoing high scatter in the bond strength data regardless which adhesive and which bond test was used. Coefficients of variation remained high (20-50%) even with the microbond test. The reported modes of failure for all tests still included high number of cohesive failures. The ranking seemed to be dependant on the test used. Significance. The scatter in dentin bond strength data remains regardless which test is used confirming Finite Element Analysis predicting non-uniform stress distributions due to a number of geometrical, loading, material properties and specimens preparation variables. This reopens the question whether, an interfacial fracture mechanics approach to analyze the dentin - adhesive bond is not more appropriate for obtaining better agreement among dentin bond related papers. (C) 2009 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective. To evaluate the biaxial and short-beam uniaxial strength tests applied to resin composites based upon their Weibull parameters, fractographic features and stress distribution. Methods. Disk- (15 mm x 1 mm) and beam-shaped specimens (10 mm x 2 mm x 1 mm) of three commercial composites (Concept/Vigodent, CA; Heliomolar/Ivoclar-Vivadent, HE; Z250/3M ESPE, FZ) were prepared. After 48h dry storage at 37 degrees C, disks and beams were submitted to piston-on-three-balls (BI) and three-point bending (UNI) tests, respectively. Data were analyzed by Weibull statistics. Fractured surfaces were observed under stereomicroscope and scanning electron microscope. Maximum principal stress (sigma(1)) distribution was determined by finite element analysis (FEA). Maximum sigma(1-BI) and sigma(1-UNI) were compared to FZ strengths calculated by applying the average failure loads to the analytical equations (sigma(a-BI) and sigma(a-UNI)). Results. For BI, characteristic strengths were: 169.9a (FZ), 122.4b (CA) and 104.8c (HE), and for UNI were: 160.3a (FZ), 98.2b (CA) and 91.6b (HE). Weibull moduli ( m) were similar within the same test. CA and HE presented statistically higher m for BI. Surface pores ( BI) and edge flaws ( UNI) were the most frequent fracture origins. sigma(1-BI) was 14% lower than sigma(a-BI.) sigma(1-UNI) was 43% higher than sigma(a-UNI). Significance. Compared to the short-beam uniaxial test, the biaxial test detected more differences among composites and displayed less data scattering for two of the tested materials. Also, biaxial strength was closer to the material`s strength estimated by FEA. (C) 2009 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.