128 resultados para damping dynamic mechanical analysis DMA CFRP electrospinning tan(delta)
Resumo:
The goal of this work was to study the liquid crystalline structure of a nanodispersion delivery system intended to be used in photodynamic therapy after loading with photosensitizers (PSs) and additives such as preservatives and thickening polymers. Polarized light microscopy and light scattering were performed on a standard nanodispersion in order to determine the anisotropy of the liquid crystalline structure and the mean diameter of the nanoparticles, respectively. Small angle X-ray diffraction (SAXRD) was used to verify the influence of drug loading and additives on the liquid crystalline structure of the nanodispersions. The samples, before and after the addition of PSs and additives, were stable over 90 days, as verified by dynamic light scattering. SAXRD revealed that despite the alteration observed in some of the samples analyzed in the presence of photosensitizing drugs and additives, the hexagonal phase still remained in the crystalline phase. (C) 2011 Wiley-Liss, Inc. and the American Pharmacists Association J Pharm Sci 100: 2849-2857, 2011
Resumo:
The objective of he article is to research the dynamic capacities developed and used by WEG in its internationalization process and to explain how these capacities help the company defends and supports competitive advantage. The article presents an exploratory study of the internationalization process of WEG in Argentina and China. This article has as analysis approach the dynamic capacities, contributes to the literature of international management in two aspects. First, it adds the analytical look of the internationalization based on dynamic capacities that are still well restricted. Second, when working the dynamic capacities as central element of the analysis of the internationalization process, it Proposes one framework of integrative analysis of the economic and behavioral theories that are used to explain the process of companies`-internationalization, although they are dealt independently and sometimes antagonistic way. The result shows as the dynamic capacities are articulated in the base of WEG in its process of internationalization for Argentina and the subsequent movement for China. The developed dynamic capacities in Argentina were acquired for the Brazilian headquarter and could have been applied in the process of internationalization for China. However, a more complex organizational structure cannot be identified where the inter-subsidiary relationships could share dynamic capacities as proposed in framework.
Resumo:
We develop a forward-looking version of the recursive dynamic MIT Emissions Prediction and Policy Analysis (EPPA) model, and apply it to examine the economic implications of proposals in the US Congress to limit greenhouse gas (GHG) emissions. We find that shocks in the consumption path are smoothed out in the forward-looking model and that the lifetime welfare cost of GHG policy is lower than in the recursive model, since the forward-looking model can fully optimize over time. The forward-looking model allows us to explore issues for which it is uniquely well suited, including revenue-recycling and early action crediting. We find capital tax recycling to be more welfare-cost reducing than labor tax recycling because of its long-term effect on economic growth. Also, there are substantial incentives for early action credits; however, when spread over the full horizon of the policy they do not have a substantial effect on lifetime welfare costs.
Resumo:
Room-temperature measurements of the magnetic susceptibility of Bovine Serum Albumin-based nanocapsules (50 to 300 nm in size) loaded with different amounts of maghemite nanoparticles (7.6 nm average diameter) have been carried out in this study The field (H) dependence of the imaginary peak susceptibility (f(P)) of the nanocomposite samples was investigated in the range of 0 to 4 kOe. From the analysis of the f(P) x H curves the concentration (N) dependence of the effective maghemite magnetocrystalline energy barrier (E) was obtained. Analysis of the E x N data was performed using a modified Morup-Tronc [Phys. Rev. Lett. 72, 3278 (1994)] model, from which a huge contribution from the magnetocrystalline surface anisotropy was observed.
Resumo:
A sensitive, selective, and reproducible in-tube solid-phase microextraction and liquid chromatographic (in-tube SPME/LC-UV) method for simultaneous determination of mirrazapine, citalopram, paroxetine, duloxetine, fluoxetine, and sertraline in human plasma was developed, validated and further applied to the analysis of plasma samples from elderly patients undergoing therapy with antidepressants. Important factors in the optimization of in-tube SPME efficiency are discussed, including the sample draw/eject volume, draw/eject cycle number, draw/eject flow-rate, sample pH, and influence of plasma proteins. The quantification limits of the in-tube SPME/LC method varied between 20 and 50 ng/mL, with a coefficient of variation lower than 10%. The response of the in-tube SPME/LC method for most of the drugs was linear over a dynamic range from 50 to 500 ng/mL, with correlation coefficients higher than 0.9985. The in-tube SPME/LC can be successfully used to analyze plasma samples from ageing patients undergoing therapy with nontricyclic antidepressants. (c) 2007 Elsevier B.V. All rights reserved.
Resumo:
A sensitive and precise stir bar sorptive extraction (SBSE) combined with LC (SBSE/LC) analysis is described for simultaneous determination of methyl, ethyl, propyl, and butyl parabens in commercial cosmetic products in agreement with the European Union Cosmetics Directive 76/768/EEC. Important factors in the optimization of SB SE efficiency are discussed, such as time and temperature of extraction, pH, and ionic strength of the sample, matrix effects, and liquid desorption conditions by different modes (magnetic stirring, ultrasonic). The LOQs of the SBSE/LC method ranged from 30 to 200 ng/mg, with linear response over a dynamic range, from the LOQ to 2.5 mu g/mg, with a coefficient of determination higher than 0.993. The interday precision of the SBSE/LC method presented a coefficient of variation lower than 5%. The effectiveness of the proposed method was proven for analysis of commercial cosmetic products such as body creams, antiperspirant creams, and sunscreens.
Resumo:
PURPOSE: To determine whether implantation of an aspherical intraocular lens (IOL) results in reduced ocular aberrations and improved contrast sensitivity after cataract surgery without critical reduction of depth of focus. DESIGN: Double-blinded, randomized, prospective study. METHODS: In an intraindividual study of 25 patients with bilateral cataract, an aspherical IOL (Akreos Advanced Optic [AO]; Bausch & Lomb, Inc., Rochester, New York, USA) was implanted in one eye and a spherical IOL (Akreos Fit; Bausch & Lomb, Inc) in the fellow eye. Higher-order aberrations with a 5- and 6-mm pupil were measured with a dynamic retinoscopy aberrometer at 1 and 3 months after surgery. Uncorrected and best-corrected visual acuity and contrast sensitivity under mesopic and photopic conditions also were measured. Distance-corrected near and intermediate visual acuity were studied as a measurement of depth of focus. RESULTS: There was no statistically significant difference between eyes in uncorrected and best-corrected visual acuity at I and 3 months after surgery. There was a statistically significant between-group difference in contrast sensitivity under photopic conditions at 12 cycles per degree and under mesopic conditions at all spatial frequencies. The Akreos AO group obtained statistically significant lower values of higher-order aberrations and spherical aberration with 5- and 6-mm pupils compared with the Akreos Fit group (P < .05). There was no significant difference in distance-corrected near and intermediate visual acuity between both groups. CONCLUSIONS: Aspherical aberration-free Akreos AO IOL induced significantly less higher-order aberrations and spherical aberration than the Akreos Fit. Contrast sensitivity was better under mesopic conditions with the Akreos AO with similar results of depth of focus. (Am J Ophthalmol 2010;149:383-389. (C) 2010 by Elsevier Inc. All rights reserved.)
Resumo:
Protrusion of the abdominal wall secondary to abdominoplasty may occur in patients with weakness of the aponeurotic structures. The anterior layer of the rectus abdominis muscle consists of fibers that are transverse rather than vertical. Based on this anatomical feature, vertical sutures are suggested for the correction of diastasis recti, since they include a greater amount of fascial fibers and thus would be more resistant to tensile strength than horizontal ones. The anterior layers of the rectus abdominis muscles of 15 fresh cadavers were dissected. Two vertical lines were marked on each side of the linea alba, corresponding to the site where plication is usually performed in abdominoplasties. Three abdominal levels were evaluated: the supraumbilical, umbilical, and infraumbilical levels. A simple suture was placed in the vertical direction in one group and in the horizontal direction in the other group, at each of the three levels previously described. These sutures were connected to a dynamometer, which was pulled medially toward the linea alba until rupture of the aponeurosis occurred. The mean strength required to rupture the aponeurotic structures in which the vertical sutures had been placed was greater than for the horizontal ones (p < 0.0001). The vertical suture of the rectus abdominis sheaths was stronger than the horizontal suture because of the more transversal arrangement of its aponeurotic fibers. Thus, routine use of the vertical suture in plications of the aponeurosis of the rectus abdominis muscles is suggested.
Resumo:
Background: Several studies have already reported the utilization of fibrin glue in microvascular anastomoses to minimize the number of sutures and to decrease the operative time. Despite the good results obtained in most of these experiments, its clinical application has not launched. The aim of this study was to clarify the controversies around the safeness of fibrin glue application in microvascular anastomoses, and also to demonstrate the potential benefits of fibrin glue application in a realistic free flap model. Methods: Twenty-seven rabbits were used in this study The experimental model consisted of a free groin flap transfer to the anterior cervical region. The flap`s circulation was restored by means of an end-to-side anastomosis between the femoral and carotid arteries, and an end-to-end anastomosis between the femoral and external jugular veins. The animals were divided into two groups (n = 10) according to the anastomosis technique: Group I (conventional suture) and group 11 (fibrin glue). Results: The number of sutures required to complete the arterial and venous anastomoses was reduced in 39 and 37% in group 11, respectively. Despite this reduction, the anastomoses maintained adequate patency rates and mechanical strength. Both arterial and venous anastomoses benefited from fibrin glue application, which made them easier and faster to perform. The flaps` ischemic time and the total operative time were also significantly shortened. Conclusions: In this study, the application of fibrin glue in microvascular anastomoses was safe and reliable. The risk-benefit ratio of fibrin glue application in microvascular anastomoses is favorable for its use. (c) 2008 Wiley-Liss, Inc.
Resumo:
Objective: Uncertainties about the numerous degrees of freedom in ventilator settings leave many unanswered questions about the biophysical determinants of lung injury. We investigated whether mechanical ventilation with high air flow could yield lung mechanical stress even in normal animals. Design. Prospective, randomized, controlled experimental study. Setting: University research laboratory. Subjects. Thirty normal male Wistar rats (180-230 g). Interventions: Rats were ventilated for 2 hrs with tidal volume of 10 mL/kg and either with normal inspiratory air flow (V`) of 10 mL/s (F10) or high V` of 30 mL/s (F30). In the control group, animals did not undergo mechanical ventilation. Because high flow led to elevated respiratory rate (200 breaths/min) and airway peak inspiratory pressure (PIP,aw = 17 cm H2O), two additional groups were established to rule out the potential contribution of these variables: a) normal respiratory rate = 100 breaths/min and V` = 30 mL/sec; and b) PIP,aw = 17 cm H2O and V` 10 mL/sec. Measurements and Main Results: Lung mechanics and histology (light and electron microscopy), arterial blood gas analysis, and type III procollagen messenger RNA expression in lung tissue were analyzed. Ultrastructural microscopy was similar in control and F10 groups. High air flow led to increased lung plateau and peak pressures, hypoxemia, alveolar hyperinflation and collapse, pulmonary neutrophilic infiltration, and augmented type III procollagen messenger RNA expression compared with control rats. The reduction of respiratory rate did not modify the morphofunctional behavior observed in the presence of increased air flow. Even though the increase in peak pressure yielded mechanical and histologic changes, type III procollagen messenger RNA expression remained unaltered. Conclusions: Ventilation with high inspiratory air flow may lead to high tensile and shear stresses resulting in lung functional and morphologic compromise and elevation of type III procollagen messenger RNA expression.
Resumo:
Background and objective: Dynamic indices represented by systolic pressure variation and pulse pressure variation have been demonstrated to be more accurate than filling pressures in predicting fluid responsiveness. However, the literature is scarce concerning the impact of different ventilatory modes on these indices. We hypothesized that systolic pressure variation or pulse pressure variation could be affected differently by volume-controlled ventilation and pressure-controlled ventilation in an experimental model, during normovolaemia and hypovolaemia. Method: Thirty-two anaesthetized rabbits were randomly allocated into four groups according to ventilatory modality and volaemic status where G1-ConPCV was the pressure-controlled ventilation control group, G2-HemPCV was associated with haemorrhage, G3-ConVCV was the volume-controlled ventilation control group and G4-HemVCV was associated with haemorrhage. In the haemorrhage groups, blood was removed in two stages: 15% of the estimated blood volume withdrawal at M1, and, 30 min later, an additional 15% at M2. Data were submitted to analysis of variance for repeated measures; a value of P < 0.05 was considered to be statistically significant. Results: At MO (baseline), no significant differences were observed among groups. At M1, dynamic parameters differed significantly among the control and hypovolaemic groups (P < 0.05) but not between ventilation modes. However, when 30% of the estimated blood volume was removed (M2), dynamic parameters became significantly higher in animals under volume-controlled ventilation when compared with those under pressure-controlled ventilation. Conclusions: Under normovolaemia and moderate haemorrhage, dynamic parameters were not influenced by either ventilatory modalities. However, in the second stage of haemorrhage (30%), animals in volume-controlled ventilation presented higher values of systolic pressure variation and pulse pressure variation when compared with those submitted to pressure-controlled ventilation.
Resumo:
Objective: Experimental study idealized to investigate the mechanical properties of deep flexor tendons of rabbits that underwent the tenotomy followed by tenorrhaphy and early application of therapeutic ultrasound with different intensities, in comparison to tendons submitted to tenorrhaphy only. Material and Method: Forty-four rabbits were divided into four experimental groups according to the ultrasound application. They were all submitted to a section of deep flexor tendon in zone 2 and immobilized with an orthosis maintained throughout the experiment. Group A received ultrasonic treatment with an intensity of 1.4 W/cm(2), group B with 0.6 W/cm(2), both in continuous mode, group C with 0.6 W/cm(2) SATA, in pulsated mode at 50% and group D did not receive any ultrasonic treatment. The ultrasonic frequency employed was 1 MHz. After euthanasia, the tendons were dissected and submitted to the mechanical test of traction and qualitative histological analysis. The evaluated mechanical properties were: maximum force, deformation in maximum force and stiffness. Results: There were no statistically significant differences among the experimental groups. Conclusion: Therapeutic ultrasound did not improve the mechanical properties of the flexor tendons after repair.
Resumo:
The purpose of this study was to examine the preventive effect of exercise on lumbar vertebrae in ovariectomized rats. Three-month-old female Wistar rats were divided into 3 groups: control group (A, n = 10); non-exercised ovariectomized group (B, n = 7) and exercised ovariectomized group (C, n = 7). The rats from group C were subjected to treadmill exercise (15 m/minute in the initial six weeks and 19 m/minute in the next six weeks, 1 hour/day, 4 days/week) for 12 weeks. At death, the fourth lumbar vertebrae were removed and an anthropometrical analysis by a paquimeter and a mechanical compression test by a universal test machine were performed. After 12 weeks, the ovariectomy decreased the superior-inferior vertebral height and the maximal braking load in group B compared to group A, while the exercise increased the vertebral mass in group C compared to both groups A and B (p < 0.01) and the stiffness compared to group B. We concluded the physical activity has an important role to prevent the osteopenia in lumbar vertebrae.
Resumo:
Objective: To verify whether preoperative respiratory muscle strength and ventilometric parameters, among other clinically relevant factors, are associated with the need for prolonged invasive mechanical ventilation (PIMV) due to cardiorespiratory complications following heart valve surgery. Methods: Demographics, preoperative ventilometric and manometric data, and the hospital course of 171 patients, who had undergone heart valve surgery at Hospital das Clinicas da Faculdade de Medicina de Ribeirao Preto, were prospectively collected and subjected to univariate analysis for identifying the risk factors for PIMV. Results: The hospital mortality was 7%. About 6% of the patients, who had undergone heart valve surgery required PIMV because of postoperative cardiorespiratory dysfunction. Their hospital mortality was 60% (vs 4%, p < 0.001). Univariate analysis revealed that preoperative respiratory muscle dysfunction, characterized by maximal inspiratory and expiratory pressure below 70% of the predicted values combined with respiratory rate above 15 rpm during ventilometry, was associated with postoperative PIMV (p = 0.030, odds ratio: 50, 95% confidence interval (CI): 1.2-18). Postoperative PIMV was also associated with: (1) body mass index (BMI) < 18.5 (odds ratio: 7.2, 95% CI: 1.5-32), (2) body weight < 50 kg (odds ratio: 6.5, 95% CI: 1.6-25), (3) valve operation due to acute endocarditis (odds ratio: 5.5, 95% CI: 0.98-30), and (4) concomitant operation for mitral and tricuspid valve dysfunction (p = 0.047, odds ratio: 5.0, 95% CI: 1.1-22). Conclusion: Our results have demonstrated that respiratory muscle dysfunction, among other clinical factors, is associated with the need for PIMV due to cardiovascular or pulmonary dysfunction after heart valve surgery. (C) 2010 European Association for Cardio-Thoracic Surgery. Published by Elsevier B. V. All rights reserved.
Resumo:
The mechanical alterations related to the excessive use of accessory respiratory muscles and the mouth breathing observed in children with asthma may lead to the development of alterations in head posture, shoulders, thoracic region and, consequently, in alterations of body posture. The purpose of this study was to assess body posture changes of children with asthma compared to a non-asthmatic control group matched for gender, age, weight, and height. Thirty children with asthma and 30 non-asthmatic children aged 7 to 12 years were enrolled in this study. Digital photographic records were obtained for analysis of the body posture of the children by computed photogrammetry. The intraclass correlation coefficient and Student`s t test (p < 0.05) were used for statistical analysis. There were no significant differences between groups for the angles analyzed, except for the knee flexor angle. These results demonstrate that children with asthma did not present postural alterations compared to non-asthmatic controls since the only angle for which there was a significant difference between groups showed weak reproducibility. The findings of this study do not support the notion that children with asthma present alterations in body posture.