238 resultados para Test structure


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Amazon forests are potentially globally significant sources or sinks for atmospheric carbon dioxide. In this study, we characterize the spatial trends in carbon storage and fluxes in both live and dead biomass (necromass) in two Amazonian forests, the Biological Dynamic of Forest Fragments Project (BDFFP), near Manaus, Amazonas, and the Tapajos National Forest (TNF) near Santarem, Para. We assessed coarse woody debris (CWD) stocks, tree growth, mortality, and recruitment in ground-based plots distributed across the terra firme forest at both sites. Carbon dynamics were similar within each site, but differed significantly between the sites. The BDFFP and the TNF held comparable live biomass (167 +/- 7.6 MgC.ha(-1) versus 149 +/- 6.0 MgC.ha(-1), respectively), but stocks of CWD were 2.5 times larger at TNF (16.2 +/- 1.5 MgC.ha(-1) at BDFFP, versus 40.1 +/- 3.9 MgC.ha(-1) at TNF). A model of current forest dynamics suggests that the BDFFP was close to carbon balance, and its size class structure approximated a steady state. The TNF, by contrast, showed rapid carbon accrual to live biomass (3.24 +/- 0.22 MgC.ha(-1).a(-1) in TNF, 2.59 +/- 0.16 MgC.ha(-1).a(-1) in BDFFP), which was more than offset by losses from large stocks of CWD, as well as ongoing shifts of biomass among size classes. This pattern in the TNF suggests recovery from a significant disturbance. The net loss of carbon from the TNF will likely last 10 - 15 years after the initial disturbance (controlled by the rate of decay of coarse woody debris), followed by uptake of carbon as the forest size class structure and composition continue to shift. The frequency and longevity of forests showing such disequilibruim dynamics within the larger matrix of the Amazon remains an essential question to understanding Amazonian carbon balance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Human activities that modify land cover can alter the structure and biogeochemistry of small streams but these effects are poorly known over large regions of the humid tropics where rates of forest clearing are high. We examined how conversion of Amazon lowland tropical forest to cattle pasture influenced the physical and chemical structure, organic matter stocks and N cycling of small streams. We combined a regional ground survey of small streams with an intensive study of nutrient cycling using (15)N additions in three representative streams: a second-order forest stream, a second-order pasture stream and a third-order pasture stream. These three streams were within several km of each other and on similar soils. Replacement of forest with pasture decreased stream habitat complexity by changing streams from run and pool channels with forest leaf detritus (50% cover) to grass-filled (63% cover) channel with runs of slow-moving water. In the survey, pasture streams consistently had lower concentrations of dissolved oxygen and nitrate (NO(3) (-)) compared with similar-sized forest streams. Stable isotope additions revealed that second-order pasture stream had a shorter NH(4) (+) uptake length, higher uptake rates into organic matter components and a shorter (15)NH(4) (+) residence time than the second-order forest stream or the third-order pasture stream. Nitrification was significant in the forest stream (19% of the added (15)NH(4) (+)) but not in the second-order pasture (0%) or third-order (6%) pasture stream. The forest stream retained 7% of added (15)N in organic matter compartments and exported 53% ((15)NH(4) (+) = 34%; (15)NO(3) (-) = 19%). In contrast, the second-order pasture stream retained 75% of added (15)N, predominantly in grasses (69%) and exported only 4% as (15)NH(4) (+). The fate of tracer (15)N in the third-order pasture stream more closely resembled that in the forest stream, with 5% of added N retained and 26% exported ((15)NH(4) (+) = 9%; (15)NO(3) (-) = 6%). These findings indicate that the widespread infilling by grass in small streams in areas deforested for pasture greatly increases the retention of inorganic N in the first- and second-order streams, which make up roughly three-fourths of total stream channel length in Amazon basin watersheds. The importance of this phenomenon and its effect on N transport to larger rivers across the larger areas of the Amazon Basin will depend on better evaluation of both the extent and the scale at which stream infilling by grass occurs, but our analysis suggests the phenomenon is widespread.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Soil from the Amazonian region is usually regarded as unsuitable for agriculture because of its low organic matter content and low pH; however, this region also contains extremely rich soil, the Terra Preta Anthrosol. A diverse archaeal community usually inhabits acidic soils, such as those found in the Amazon. Therefore, we hypothesized that this community should be sensitive to changes in the environment. Here, the archaeal community composition of Terra Preta and adjacent soil was examined in four different sites in the Brazilian Amazon under different anthropic activities. The canonical correspondence analysis of terminal restriction fragment length polymorphisms has shown that the archaeal community structure was mostly influenced by soil attributes that differentiate the Terra Preta from the adjacent soil (i.e., pH, sulfur, and organic matter). Archaeal 16S rRNA gene clone libraries indicated that the two most abundant genera in both soils were Candidatus nitrosphaera and Canditatus nitrosocaldus. An ammonia monoxygenase gene (amoA) clone library analysis indicated that, within each site, there was no significant difference between the clone libraries of Terra Preta and adjacent soils. However, these clone libraries indicated there were significant differences between sites. Quantitative PCR has shown that Terra Preta soils subjected to agriculture displayed a higher number of amoA gene copy numbers than in adjacent soils. On the other hand, soils that were not subjected to agriculture did not display significant differences on amoA gene copy numbers between Terra Preta and adjacent soils. Taken together, our findings indicate that the overall archaeal community structure in these Amazonian soils is determined by the soil type and the current land use.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Although the Clock Drawing Test (CDT) is the second most used test in the world for the screening of dementia, there is still debate over its sensitivity specificity, application and interpretation in dementia diagnosis. This study has three main aims: to evaluate the sensitivity and specificity of the CDT in a sample composed of older adults with Alzheimer`s disease (AD) and normal controls; to compare CDT accuracy to the that of the Mini-mental State Examination (MMSE) and the Cambridge Cognitive Examination (CAMCOG), and to test whether the association of the MMSE with the CDT leads to higher or comparable accuracy as that reported for the CAMCOG. Methods: Cross-sectional assessment was carried out for 121 AD and 99 elderly controls with heterogeneous educational levels from a geriatric outpatient clinic who completed the Cambridge Examination for Mental Disorder of the Elderly (CAMDEX). The CDT was evaluated according to the Shulman, Mendez and Sunderland scales. Results: The CDT showed high sensitivity and specificity. There were significant correlations between the CDT and the MMSE (0.700-0.730; p < 0.001) and between the CDT and the CAMCOG (0.753-0.779; p < 0.001). The combination of the CDT with the MMSE improved sensitivity and specificity (SE = 89.2-90%; SP = 71.7-79.8%). Subgroup analysis indicated that for elderly people with lower education, sensitivity and specificity were both adequate and high. Conclusions: The CDT is a robust screening test when compared with the MMSE or the CAMCOG, independent of the scale used for its interpretation. The combination with the MMSE improves its performance significantly, becoming equivalent to the CAMCOG.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The ""Short Cognitive Performance Test"" (Syndrom Kurztest, SKT) is a cognitive screening battery designed to detect memory and attention deficits. The aim of this study was to evaluate the diagnostic accuracy of the SKT as a screening tool for mild cognitive impairment (MCI) and dementia. A total of 46 patients with Alzheimer`s disease (AD), 82 with MCI, and 56 healthy controls were included in the study. Patients and controls were allocated into two groups according to educational level (< 8 years or > 8 years). ROC analyses suggested that the SKT adequately discriminates AD from non-demented subjects (MCI and controls), irrespective of the education group. The test had good sensitivity to discriminate MCI from unimpaired controls in the sub-sample of individuals with more than 8 years of schooling. Our findings suggest that the SKT is a good screening test for cognitive impairment and dementia. However, test results must be interpreted with caution when administered to less-educated individuals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Continuing our series of papers on the three-dimensional (3D) structure and accurate distances of planetary nebulae (PNe), we present here the results obtained for PN NGC 40. Using data from different sources and wavelengths, we construct 3D photoionization models and derive the physical quantities of the ionizing source and nebular gas. The procedure, discussed in detail in the previous papers, consists of the use of 3D photoionization codes constrained by observational data to derive the 3D nebular structure, physical and chemical characteristics, and ionizing star parameters of the objects by simultaneously fitting the integrated line intensities, the density map, the temperature map, and the observed morphologies in different emission lines. For this particular case we combined hydrodynamical simulations with the photoionization scheme in order to obtain self-consistent distributions of density and velocity of the nebular material. Combining the velocity field with the emission-line cubes we also obtained the synthetic position-velocity plots that are compared to the observations. Finally, using theoretical evolutionary tracks of intermediate-and low-mass stars, we derive the mass and age of the central star of NGC 40 as (0.567 +/- 0.06) M(circle dot) and (5810 +/- 600) yr, respectively. The distance obtained from the fitting procedure was (1150 +/- 120) pc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Assuming as a starting point the acknowledge that the principles and methods used to build and manage the documentary systems are disperse and lack systematization, this study hypothesizes that the notion of structure, when assuming mutual relationships among its elements, promotes more organical systems and assures better quality and consistency in the retrieval of information concerning users` matters. Accordingly, it aims to explore the fundamentals about the records of information and documentary systems, starting from the notion of structure. In order to achieve that, it presents basic concepts and relative matters to documentary systems and information records. Next to this, it lists the theoretical subsides over the notion of structure, studied by Benveniste, Ferrater Mora, Levi-Strauss, Lopes, Penalver Simo, Saussure, apart from Ducrot, Favero and Koch. Appropriations that have already been done by Paul Otlet, Garcia Gutierrez and Moreiro Gonzalez. In Documentation come as a further topic. It concludes that the adopted notion of structure to make explicit a hypothesis of real systematization achieves more organical systems, as well as it grants pedagogical reference to the documentary tasks.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to propose an alternative method (MAOD(ALT)) to estimate the maximal accumulated oxygen deficit (MAOD) using only one supramaximal exhaustive test. Nine participants performed the following tests: (a) a maximal incremental exercise test, (b) six submaximal constant workload tests, and (c) a supramaximal constant workload test. Traditional MAOD was determined by calculating the difference between predicted O(2) demand and accumulated O(2) uptake during the supramaximal test. MAOD(ALT) was established by summing the fast component of excess post-exercise oxygen consumption and the O(2) equivalent for energy provided by blood lactate accumulation, both of which were measured during the supramaximal test. There was no significant difference between MAOD (2.82 +/- 0.45 L) and MAOD(ALT) (2.77 +/- 0.37 L) (p = 0.60). The correlation between MAOD and MAOD(ALT) was also high (r = 0.78; p = 0.014). These data indicate that the MAOD(ALT) can be used to estimate the MAOD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study compared measurements of upper body aerobic fitness in elite (EC; n = 7) and intermediate rock climbers (IC; n = 7), and a control group (C; n = 7). Subjects underwent an upper limb incremental test on hand cycle ergometer, with increments of 23 W.min(-1), until exhaustion. Ventilation (VE) data were smoothed to 10 s averages and plotted against time for the visual determination of the first (VT1) and second (VT2) ventilatory thresholds. Peak power output was not different among groups [EC = 130.9 (+/- 11.8) W; IC = 122.1 (+/- 28.4) W; C = 115.4 (+/- 15.1) W], but time to exhaustion was significantly higher in EC than IC and C. VO(2PEAK) was significantly higher in EC [36.8 (+/- 5.7) mL.kg(-1).min(-1)] and IC [35.5 (+/- 5.2) mL.kg(-1).min(-1)] than C [28.8 (+/- 5.0) mL.kg(-1).min(-1)], but there was no difference between EC and IC. VT1 was significantly higher in EC than C [EC = 69.0 (+/- 9.4) W; IC = 62.4 (+/- 13.0) W; C = 52.1 (+/- 11.8) W], but no significant difference was observed in VT2 [EC = 103.5 (+/- 18.8) W; IC = 92.0 (+/- 22.0) W; C = 85.6 (+/- 19.7) W]. These results show that elite indoor rock climbers elicit higher aerobic fitness profile than control subjects when measured with an upper body test.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Miarka, B, Del Vecchio, FB, and Franchini, E. Acute effects and postactivation potentiation in the special judo fitness test. J Strength Cond Res 25(2): 427-431, 2011-The purpose of this study was to compare the acute short-term effects of (1) plyometric exercise, (2) combined strength and plyometric exercise (contrast), and (3) maximum strength performance in the Special Judo Fitness Test (SJFT). Eight male judo athletes (mean +/- SD, age, 19 +/- 1 years; body mass, 60.4 +/- 5 kg; height, 168.3 +/- 5.4 cm) took part in this study. Four different sessions were completed; each session had 1 type of intervention: (a) SJFT control, (b) plyometric exercises + SJFT, (c) maximum strength + SJFT, and (d) contrast + SJFT. The following variables were quantified: throws performed during series A, B, and C; total number of throws; heart rate immediately and 1 minute after the test; and test index. Significant differences were found in the number of throws during series A: the plyometric exercise (6.4 +/- 0.5 throws) was superior (p < 0.05) to the control condition (5.6 +/- 0.5 throws). Heart rate 1 minute after the SJFT was higher (p < 0.01) during the plyometric exercise (192 +/- 8 bpm) than during the contrast exercise (184 +/- 9 bpm). The contrast exercise (13.58 +/- 0.72) resulted in better index values than the control (14.67 +/- 1.30) and plyometric exercises (14.51 +/- 0.54). Thus, this study suggests that contrast and plyometric exercises performed before the SJFT can result in improvements in the test index and anaerobic power of judo athletes, respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of the present study was to verify if active recovery (AR) applied after a judo match resulted in a better performance when compared to passive recovery (PR) in three tasks varying in specificity to the judo and in measurement of work performed: four upper-body Wingate tests (WT); special judo fitness test (SJFT); another match. For this purpose, three studies were conducted. Sixteen highly trained judo athletes took part in study 1, 9 in study 2, and 12 in study 3. During AR judokas ran (15 min) at the velocity corresponding to 70% of 4 mmol l(-1) blood lactate intensity (similar to 50% (V) over dotO(2) peak), while during PR they stayed seated at the competition area. The results indicated that the minimal recovery time reported in judo competitions (15 min) is long enough for sufficient recovery of WT performance and in a specific high-intensity test (SJFT). However, the odds ratio of winning a match increased ten times when a judoka performed AR and his opponent performed PR, but the cause of this phenomenon cannot be explained by changes in number of actions performed or by changes in match`s time structure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and Study Aim: Judo is very physiological demanding sport, but there are no many physical fitness specific tests. One of the most used specific judo tests is the Special Judo Fitness Test (SJFT) proposed by Sterkowicz ( 1995). Although this test has been used by many coaches in different countries no classificatory table was found to classify the judo athletes according to their results. Thus, the aim of this work was to present a classificatory table for this test. Material/Methods: For this purpose 141 judo athletes ( mean +/-standard deviation: 21.3+/-4.5years-old; 74.2+/-15.9 kg of body mass and 176.7+/-8.2 cm of height; judo ranking between 3(rd) kyu and 3(rd) dan) familiarized with the SJFT performed it once in order to provide data to establish a classificatory table. Results: After the analysis of data distribution a five scale table (20% for each classificatory category) was developed considering the variables used in the SJFT ( number of throws, heart rate after and 1 min after the test and index). Conclusions: The classificatory table can help coaches using the SJFT to classify their athletes` level and to monitor their physical fitness progress.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We analyzed the usefulness of a semi-tethered field running test (STR) and the relationships between indices of anaerobic power, anaerobic capacity and running performance in 9 trained male sprinters (22.2 +/- 2.9 yrs, 176 +/- 1 cm, 68.0 +/- 9.4 kg). STR involved an all out 120 m run attached to an apparatus that enabled power calculation from force and velocity measures. Subjects also carried out a cycloergometer Win-gate Anaerobic Test (WT), an all out 300 m run and had accessed their maximal accumulated oxygen deficit (MAOD) on a treadmill. Peak and mean powers attained in STR (1 720 +/- 221 and 1 391 +/- 201 W) were greater but significantly related (r=0.82; P<0.01) to those in the WT (808 +/- 130 and 603 +/- 87 W). In addition, power measures derived from the STR were stronger related to running performance compared to those from the WT (r=0.81-0.94 vs. 0.68-0.84; P<0.05). Relationships between MAOD and most power indices were only weak to moderate. These results support the usefulness of STR for specific power assessment in field running and suggest that anaerobic power and capacity are not related entities, irrespective of having been evaluated using similar or dissimilar exercise modes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A bifilar Bi-2212 bulk coil with parallel shunt resistor was tested under fault current condition using a 3 MVA single-phase transformer in a 220 V-60 Hz line achieving fault current peak of 8 kA. The fault current tests are performed from steady state peak current of 200 A by applying controlled short circuits up to 8 kA varying the time period from one to six cycles. The test results show the function of the shunt resistor providing homogeneous quench behavior of the HTS coil besides its intrinsic stabilizing role. The limiting current ratio achieves a factor 4.2 during 5 cycles without any degradation.