107 resultados para LOW LEVEL LASER THERAPY


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Multiple lineages of Brazilian strains from 2007 to 2008 of avian infectious bronchitis virus (IBV) were detected in flocks of breeders, broilers, and layers. Organs samples from 20 IBV-positive flocks with variable clinical signs were submitted to the partial amplification of S gene (nucleotides 726-1071) of IBV. Fifteen of the 20 sequenced strains segregated in a unique Brazilian cluster subdivided in three subclusters (Brazil 01, 02, and 03). Whereas three strains could be classified as Massachusetts (Mass) genotype, the remaining two strains, originating from flocks with reproductive and respiratory disorders, grouped within the 4/91-793B genotype, a genotype that has not been detected before in Brazil. The potential relevance of the findings to the poultry industry is discussed because the low level of identity of the sequenced part of the S gene from 17 of 20 detected field strains and the vaccines of the Massachusetts serotype used suggest that the level of cross-protection by the Massachusetts vaccines might be low.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To evaluate the effect of light guide distance and the different photoactivation methods on the degree of conversion (DC) and microleakage of a composite. Methods and Materials: Three photoactivation protocols (600mW/cm(2) x 40 seconds; 400 mW/cm(2) x 60 seconds or 200 mW/cm(2) x 20 seconds, followed by 500 mW/cm(2) X 40 seconds) and three distances from the light source (0, 3 or 7 mm) were tested. Cylindrical specimens (5 nun diameter; 2 mm tall; n=3) were prepared for the DC test (FT-Raman). Class V cavities were made in 90 bovine incisors to conduct the microleakage test. The specimens were conditioned for 15 seconds with phosphoric acid (37%), followed by application of the adhesive system Prime & Bond NT (Dentsply/Caulk). The preparations were restored in bulk. The specimens were stored for 24 hours in distilled water (37 degrees C) before being submitted to the silvernitrate microleakage protocol. The restorations were sectioned and analyzed under 25x magnification. Results: Statistical analyses (two-way ANOVAs and Tukey test, alpha=0.05) found significance only for the factor distance (p=0.015) at the top of the composite for the DC test. Conversion was statistically lower for the 7 mm groups compared to the 0 and 3 mm groups, which were equivalent to each other. At the bottom of the specimens, none of the factors or interactions was significant (p<0.05). The Kruskal-Wallis test showed that, in general, the soft-start method led to lower microleakage scores when compared to the continuous modes, mainly when associated with a distancing of 7 mm (p<0.01). With the exception of specimens irradiated with 400mW/cm(2) that did not demonstrate variations on scores for the distances tested, higher microleakage was observed for shorter distances from the light source. Conclusions: Soft-start methods may reduce microleakage when the light guide distancing provides a low level of irradiance, which also causes a discrete reduction in the DC.