144 resultados para DIRECT ELECTRICAL COMMUNICATION
Resumo:
Motor cortex stimulation oriented by functional cortical mapping is used mainly for treating otherwise intractable neurological disorders, however. its mechanism of action remains elusive. Herein, we present a new method for functional mapping of the rat motor cortex using non-invasive transdural electrical stimulation. This method allows a non-invasive mapping of the surface of the neocortex providing a differentiation of representative motor areas. This Study may facilitate further investigation about the mechanisms mediating the effects of electrical stimulation, possibly benefiting patients who do not respond to this neuromodulation therapy. (c) 2009 Elsevier B.V. All rights reserved.
Resumo:
To present a novel algorithm for estimating recruitable alveolar collapse and hyperdistension based on electrical impedance tomography (EIT) during a decremental positive end-expiratory pressure (PEEP) titration. Technical note with illustrative case reports. Respiratory intensive care unit. Patients with acute respiratory distress syndrome. Lung recruitment and PEEP titration maneuver. Simultaneous acquisition of EIT and X-ray computerized tomography (CT) data. We found good agreement (in terms of amount and spatial location) between the collapse estimated by EIT and CT for all levels of PEEP. The optimal PEEP values detected by EIT for patients 1 and 2 (keeping lung collapse < 10%) were 19 and 17 cmH(2)O, respectively. Although pointing to the same non-dependent lung regions, EIT estimates of hyperdistension represent the functional deterioration of lung units, instead of their anatomical changes, and could not be compared directly with static CT estimates for hyperinflation. We described an EIT-based method for estimating recruitable alveolar collapse at the bedside, pointing out its regional distribution. Additionally, we proposed a measure of lung hyperdistension based on regional lung mechanics.
Resumo:
Objectives: Pneumothorax is a frequent complication during mechanical ventilation. Electrical impedance tomography (EIT) is a noninvasive tool that allows real-time imaging of regional ventilation. The purpose of this study was to 1) identify characteristic changes in the EIT signals associated with pneumothoraces; 2) develop and fine-tune an algorithm for their automatic detection; and 3) prospectively evaluate this algorithm for its sensitivity and specificity in detecting pneumothoraces in real time. Design: Prospective controlled laboratory animal investigation. Setting: Experimental Pulmonology Laboratory of the University of Sao Paulo. Subjects: Thirty-nine anesthetized mechanically ventilated supine pigs (31.0 +/- 3.2 kg, mean +/- SD). Interventions. In a first group of 18 animals monitored by EIT, we either injected progressive amounts of air (from 20 to 500 mL) through chest tubes or applied large positive end-expiratory pressure (PEEP) increments to simulate extreme lung overdistension. This first data set was used to calibrate an EIT-based pneumothorax detection algorithm. Subsequently, we evaluated the real-time performance of the detection algorithm in 21 additional animals (with normal or preinjured lungs), submitted to multiple ventilatory interventions or traumatic punctures of the lung. Measurements and Main Results: Primary EIT relative images were acquired online (50 images/sec) and processed according to a few imaging-analysis routines running automatically and in parallel. Pneumothoraces as small as 20 mL could be detected with a sensitivity of 100% and specificity 95% and could be easily distinguished from parenchymal overdistension induced by PEEP or recruiting maneuvers, Their location was correctly identified in all cases, with a total delay of only three respiratory cycles. Conclusions. We created an EIT-based algorithm capable of detecting early signs of pneumothoraces in high-risk situations, which also identifies its location. It requires that the pneumothorax occurs or enlarges at least minimally during the monitoring period. Such detection was operator-free and in quasi real-time, opening opportunities for improving patient safety during mechanical ventilation.
Resumo:
Electrical impedance tomography is a technique to estimate the impedance distribution within a domain, based on measurements on its boundary. In other words, given the mathematical model of the domain, its geometry and boundary conditions, a nonlinear inverse problem of estimating the electric impedance distribution can be solved. Several impedance estimation algorithms have been proposed to solve this problem. In this paper, we present a three-dimensional algorithm, based on the topology optimization method, as an alternative. A sequence of linear programming problems, allowing for constraints, is solved utilizing this method. In each iteration, the finite element method provides the electric potential field within the model of the domain. An electrode model is also proposed (thus, increasing the accuracy of the finite element results). The algorithm is tested using numerically simulated data and also experimental data, and absolute resistivity values are obtained. These results, corresponding to phantoms with two different conductive materials, exhibit relatively well-defined boundaries between them, and show that this is a practical and potentially useful technique to be applied to monitor lung aeration, including the possibility of imaging a pneumothorax.
Resumo:
This study aims to review the experience, at an institution, with patients who suffered electrical burns and study the peculiar characteristics of this type of burn as well as its complications and epidemiological aspects. The study includes medical records of patients with electrical burns who were admitted to the Burn Unit of Hospital das Clinicas in Sao Paulo, Brazil, from November 2001 to October 2006. They were classified into four categories: high voltage (>= 1000 V), low voltage (<1000 V), `flash burn` (in which there is no electrical current flow through the body of the patient) and burns caused by lightning. The complications were more severe and common in the high-voltage group, while longer hospital stays and more complex surgical procedures due to the greater depth of burns were also observed in this group. High-voltage burns are mainly labour-/occupation-related. The majority of the patients were young men at the beginning of their professional lives. This factor generates an important socio-economic impact due to the high incidence of sequelae, resulting in amputations, rendering them unable to maintain their occupations. (C) 2009 Elsevier Ltd and ISBI. All rights reserved.
Resumo:
BACKGROUND: Even though porphyria cutanea tarda is the most frequent type of porphyria, there are few studies about its cutaneous physiopathology. OBJECTIVE: To evaluate skin changes in porphyria cutanea tarda using light microscopy and direct immunofluorescence before and after treatment with chloroquine. To perform antigen immunomapping of bullae to study their level of cleavage. METHODS: Light microscopy and direct immunofluorescence of 28 patients are reported in three different phases: 23 patients with active porphyria before treatment (Phase A), 7 patients with clinical remission during treatment (Phase B), and 8 patients with biochemical remission (Phase C). Immunomapping was performed on 7 patients. RESULTS: In active porphyria, direct immunofluorescence showed homogenous and intense fluorescence on the inside and on the walls of blood vessels as well as in the dermal-epidermal junction. In clinical remission (Phase B) and biochemical remission (Phase C), the deposit of immunoglobulins was maintained, but the deposit of complement was reduced in most cases. Immunomapping revealed no standard cleavage plane. CONCLUSION: No correlation was observed between clinical response and immunoglobulin deposits. The reduction of complement favors the hypothesis that activation of the complement cascade represents an additional pathway that leads to endothelial damage.
Resumo:
The purpose of this study was to examine how key occupational therapy terminologies are used by Brazilian occupational therapists. A nominal group approach combined with a Delphi technique involving 31 Brazilian occupational therapists was applied. A sociolinguistic approach was adopted since it broadens our understanding of the social and cultural determinants of terminology consolidation. Brazilian occupational therapists were found to adopt the term activity more often than human action or doing. Even less often were praxis and occupation applied. No consensus was reached regarding which of the terms is most preferred. While Brazilian occupational therapists have been developing their profession from international standards, it is still embedded in local demands and policies. Additionally, the political context must be considered when building an international dialogue between members of a professional body. Such a dialogue could engage professionals from different countries in meaningful exchanges about their practices. These exchanges may lead to the development of solid professional communities that can contribute meaningfully to social change. Copyright (C) 2010 John Wiley & Sons, Ltd.
Resumo:
This study vas aimed to validate the American Speech-Language-Hearing Association Functional Assessment Of Communication Skills (ASHA FACS) for a Brazilian population. The scale was translated and adapted into Portuguese. Thirty-two patients with mild Alzheimer disease (AD). 25 patients with moderate AD. and 51 elderly without dementia were examined with Mini Mental State Examination, Geriatric Depression Scale. and Alzheimer Disease Assessment Scale-Cognitive subscale (ADAS-cog). The ASHA FACS was answered by their relative/caregiver. The scale`s internal consistency. its inter-examiner and intra-examiner`s reproducibility. and scale`s criterion validity were researched by correlation with ADAS-cog,. The sensitivity and specificity Were also researched. Statistical analyses indicated that the ASHA FACS has excellent internal consistency (Cronbach alpha = 0.955), test-retest reliability (interclass correlation coefficient = 0.995; P < 0.001). and inter-examiners (interclass correlation coefficient = 0.998: P < 0.001). It showed excellent criterion validity when correlated with ADAS-cog,. The ASHA FACS scale showed good sensitivity (75.0%) and specificity (82.4%) values once it is an ecologic and broad evaluation. The ASHA FACS Portuguese version is a valid and reliable instrument to verify communication alterations in AD patients and fills an important gap of efficiency indicators for speech language therapy in our country.
Resumo:
In Brazil there are no specific tests for either signed or spoken language for deaf children. A protocol evaluating communicative abilities independent of modality of communication (sign language or spoken language), and comprising assessments of (a) pragmatic profile; (b) modality of communication and linguistic level; (c) complexity of communication; and (d) style and efficacy of communication between parent and child was administered to 127 deaf and hearing children. The children, aged 3-6 years old, were distributed in three groups: 20 with severe hearing loss, 40 with profound hearing loss and 67 normally hearing. Deaf children were found to be delayed, independent of their linguistic level and preferred modality of communication. The protocol in this study proved to be an useful instrument for gathering relevant information about the three groups of preschool children`s communicative abilities, and particularly suitable for use in countries where standardized assessments are not available. Learning outcomes: The reader will be introduced to the use of an assessment protocol comprising its development, application and data analysis. The reader will be informed about assessment of deaf children`s preferred modality of communication, by the participation of a bilingual (sign language user) professional. Communication abilities can be assessed independently of the linguistic modality. In developing countries in general, where simple and easy to administer assessments tools are scarce, such a protocol is of specific value. (c) 2010 Elsevier Inc. All rights reserved.
Resumo:
Compared with other specialties, the field of physical and rehabilitation medicine has not received the deserved recognition from clinicians and researchers in the scientific community. One of the reasons is the lack of sound evidence to support the traditional physical and rehabilitation medicine treatments. The best way to change this disadvantage is through a well conducted clinical research, such as standard placebo- or sham-controlled randomized clinical trials. Therefore, having placebo groups in clinical trials is essential to improve the level of evidence-based practice in physical and rehabilitation medicine that ultimately translates to better clinical care. To address the challenges for the use of placebo in physical and rehabilitation medicine and randomized clinical trials and to create useful recommendations, we convened a working group during the inaugural International Symposium in Placebo (February 2009, in Sao Paulo, Brazil) in which the following topics were discussed: (1) current status of randomized clinical trials in physical and rehabilitation medicine, (2) challenges for the use of placebo in physical and rehabilitation medicine, (3) bioethics, (4) use of placebo in acupuncture trials and for the treatment of low-back pain, (5) mechanisms of placebo, and (6) insights from other specialties. The current article represents the consensus report from the working group.
Resumo:
Purpose: Several attempts to determine the transit time of a high dose rate (HDR) brachytherapy unit have been reported in the literature with controversial results. The determination of the source speed is necessary to accurately calculate the transient dose in brachytherapy treatments. In these studies, only the average speed of the source was measured as a parameter for transit dose calculation, which does not account for the realistic movement of the source, and is therefore inaccurate for numerical simulations. The purpose of this work is to report the implementation and technical design of an optical fiber based detector to directly measure the instantaneous speed profile of a (192)Ir source in a Nucletron HDR brachytherapy unit. Methods: To accomplish this task, we have developed a setup that uses the Cerenkov light induced in optical fibers as a detection signal for the radiation source moving inside the HDR catheter. As the (192)Ir source travels between two optical fibers with known distance, the threshold of the induced signals are used to extract the transit time and thus the velocity. The high resolution of the detector enables the measurement of the transit time at short separation distance of the fibers, providing the instantaneous speed. Results: Accurate and high resolution speed profiles of the 192Ir radiation source traveling from the safe to the end of the catheter and between dwell positions are presented. The maximum and minimum velocities of the source were found to be 52.0 +/- 1.0 and 17.3 +/- 1:2 cm/s. The authors demonstrate that the radiation source follows a uniformly accelerated linear motion with acceleration of vertical bar a vertical bar = 113 cm/s(2). In addition, the authors compare the average speed measured using the optical fiber detector to those obtained in the literature, showing deviation up to 265%. Conclusions: To the best of the authors` knowledge, the authors directly measured for the first time the instantaneous speed profile of a radiation source in a HDR brachytherapy unit traveling from the unit safe to the end of the catheter and between interdwell distances. The method is feasible and accurate to implement on quality assurance tests and provides a unique database for efficient computational simulations of the transient dose. (C) 2010 American Association of Physicists in Medicine. [DOI: 10.1118/1.3483780]
Resumo:
Our study aims to investigate changes in electrocortical activity by observing the variations in absolute theta power in the primary somatomotor and parietal regions of the brain under three different electrical stimulation conditions: control group (without stimulation), group 24 (24 trials of stimulation) and group 36 (36 trials of stimulation). Thus, our hypothesis is that the application of different patterns of electrical stimulation will promote different states of habituation in these regions. The sample was composed of 24 healthy (absence of mental and physical impairments) students (14 male and 10 female), with ages varying from 25 to 40 years old (32.5 +/- 7.5), who are right-handed (Edinburgh Inventory). The subjects were randomly distributed into three groups: control (n = 8), G24 (n = 8) and G36 (n = 8). We use the Functional electrical stimulation (FES) equipment (NeuroCompact-2462) to stimulate the right index finger extensor muscle, while the electroencephalographic signal was simultaneously recorded. We found an interaction between condition and block factors for the C3 and P3 electrode, a condition and block main effects for the C4 electrode, and a condition main effect for the P4 electrode. Our results support the hypothesis that electrical stimulation promotes neurophysiological changes. It appears that stimulus adaptation (accommodation) of specific circuits can strengthen the brain`s ability to distinguish between and respond to such stimuli over time. (C) 2009 Elsevier Ireland Ltd. All rights reserved.
Resumo:
Introduction: In vitro studies and ambulatory ECG recordings from the MERLIN TIMI-36 clinical trial suggest that the novel antianginal agent ranolazine may have the potential to suppress atrial arrhythmias. However, there are no reports of effects of ranolazine on atrial electrophysiologic properties in large intact animals. Methods and Results: In 12 closed-chest anesthetized pigs, effects of intravenous ranolazine (similar to 9 mu M plasma concentration) on multisite atrial effective refractory period (ERP), conduction time (CT), and duration and inducibility of atrial fibrillation (AF) initiated by intrapericardial acetylcholine were investigated. Ranolazine increased ERP by a median of 45 ms (interquartile range 29-50 ms; P < 0.05, n = 6) in right and left atria compared to control at pacing cycle length (PCL) of 400 ms. However, ERP increased by only 28 (24-34) ms in right ventricle (P < 0.01, n = 6). Ranolazine increased atrial CT from 89 (71-109) ms to 98 (86-121) ms (P = 0.04, n = 6) at PCL of 400 ms. Ranolazine decreased AF duration from 894 (811-1220) seconds to 621 (549-761) seconds (P = 0.03, n = 6). AF was reinducible in 1 of 6 animals after termination with ranolazine compared with all 6 animals during control period (P = 0.07). Dominant frequency (DF) of AF was reduced by ranolazine in left atrium from 11.7 (10.7-20.5) Hz to 7.6 (2.9-8.8) Hz (P = 0.02, n = 6). Conclusions: Ranolazine, at therapeutic doses, increased atrial ERP to greater extent than ventricular ERP and prolonged atrial CT in a frequency-dependent manner in the porcine heart. AF duration and DF were also reduced by ranolazine. Potential role of ranolazine in AF management merits further investigation. (J Cardiovasc Electrophysiol, Vol. 20, pp. 796-802, July 2009).