108 resultados para Computer network protocols.


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: The purpose of this study was to compare the occlusal outcomes and the efficiency of 1-phase and 2-phase treatment protocols in Class II Division 1 malocclusions. Treatment efficiency was defined as a change in the occlusal characteristics in a shorter treatment time. Methods: Class II Division 1 subjects ( n = 139) were divided into 2 groups according to the treatment protocol for Class II correction. Group 1 comprised 78 patients treated with a 1-phase treatment protocol at initial and final mean ages of 12.51 and 14.68 years. Group 2 comprised 61 patients treated with a 2-phase treatment protocol at initial and final mean ages of 11.21 and 14.70 years. Lateral cephalometric radiographs were taken at the pretreatment stage to evaluate morphological differences in the groups. The initial and final study models of the patients were evaluated by using the peer assessment rating index. Chi-square tests were used to test for differences between the 2 groups for categorical variables. Variables regarding occlusal results were compared by using independent t tests. A linear regression analysis was completed, with total treatment time as the dependent variable, to identify clinical factors that predict treatment length for patients with Class II malocclusions. Results: Similar occlusal outcomes were obtained between the 1-phase and the 2-phase treatment protocols, but the duration of treatment was significantly shorter in the 1-phase treatment protocol group. Conclusions: Treatment of Class II Division 1 malocclusions is more efficient with the 1-phase than the 2-phase treatment protocol.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To evaluate several protocols for the application of ultrasound during removal of cast posts with varying core configurations cemented with zinc phosphate. Sixty maxillary canines were distributed into three groups (n = 20): group 1 - core with 5 mm diameter/height and post diameter of 1.3 mm; groups 2 and 3 - core with the same diameter as the post (1.3 mm) and heights of 5 mm and 3 mm, respectively. Posts/cores were cemented using a standard technique with zinc phosphate cement. Each group was divided into two subgroups according to the ultrasonic vibration mode: point vibration - ultrasonic vibration applied to the core surface for 5 s, on each face totalling 25 s; alternate vibration - intermittent application of ultrasonic vibration for 10 s to the labial and lingual surfaces, 10 s to the mesial and distal surfaces and 5 s to the incisal surface, totalling 25 s. The specimens were submitted to the tensile test using an Instron machine (1 mm min(-1)) and results were analysed by anova and t-test. The failure type was also analysed. Statistical analysis showed significant differences between groups relating to the core preparations (P < 0.05). The lowest mean values of traction force were obtained for group 3 (46.1 +/- 7.7 N), followed by group 2 (89.0 +/- 2.7 N) and group 1 (160.4 +/- 7.5 N). Regarding ultrasonic vibration, the lowest mean was observed with alternate vibration (81.1 +/- 10.1 N), which was significantly lower than the point vibration (115.9 +/- 9.5 N) (P < 0.05). Cohesive failure occurred in all cases. A reduction in core diameter/height and intermittent ultrasonic application improved the removal of cast posts cemented with zinc phosphate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The aim of this study was to evaluate the influence of artificial accelerated aging on dimensional stability of two types of acrylic resins (thermally and chemically activated) submitted to different protocols of storage. Materials and Methods: One hundred specimens were made using a Teflon matrix (1.5cmx0.5mm) with four imprint marks, following the lost-wax casting method. The specimens were divided into ten groups, according to the type of acrylic resin, aging procedure, and storage protocol (30 days). GI: acrylic resins thermally activated, aging, storage in artificial saliva for 16 hours, distilled water for 8 hours; GII: thermal, aging, artificial saliva for 16 hours, dry for 8 hours; GIII: thermal, no aging, artificial saliva for 16 hours, distilled water for 8 hours, GIV: thermal, no aging, artificial saliva for 16 hours, dry for 8 hours; GV: acrylic resins chemically activated, aging, artificial saliva for 16 hours, distilled water for 8 hours; GVI: chemical, aging, artificial saliva for 16 hours, dry for 8 hours; GVII: chemical, no aging, artificial saliva for 16 hours, distilled water for 8 hours; GVIII: chemical, no aging, artificial saliva for 16 hours, dry for 8 hours GIX: thermal, dry for 24 hours; and GX: chemical, dry for 24 hours. All specimens were photographed before and after treatment, and the images were evaluated by software (UTHSCSA-Image Tool) that made distance measurements between the marks in the specimens (mm), calculating the dimensional stability. Data were submitted to statistical analysis (two-way ANOVA, Tukey test, p = 0.05). Results: Statistical analysis showed that the specimens submitted to storage in water presented the largest distance between both axes (major and minor), statistically different (p < 0.05) from control groups. Conclusions: All acrylic resins presented dimensional changes, and the artificial accelerated aging and storage period influenced these alterations.