201 resultados para 321023 Radiotherapy and Nuclear Medicine


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: The use of complementary and alternative medicine (CAM) to treat cancer patients has increased around the world, and its benefits have been described. These therapies represent an important theme in oncology and have been used in parallel with conventional therapies. Objective: This study aimed to assess the outcomes of using relaxation with visualization and acupuncture on the quality of life of cancer patients undergoing chemotherapy treatment and to compare these outcomes with patients who did not choose to receive the intervention. Methods: Participants chose to be in either the intervention group (IG) or control group (CG). They completed the Quality of Life Questionnaire-Core 30 at the start and end of chemotherapy. The IG was chosen by 38 patients with different types of cancer who completed weekly relaxation with visualization and acupuncture sessions, whereas the CG was composed of 37 patients who did not receive the intervention. Results: Statistically significant results evidenced an increase in global health and emotional and social functions and a decrease in fatigue and loss of appetite for the IG, and an increase in global health for the CG (P <= .05). A highly significant difference was found when comparing the post-chemotherapy scores of the Quality of Life Questionnaire-Core 30 in the global health domain between the CG and the IG (P <= .001), indicating positive outcomes of the CAM intervention. Conclusion: Adults with cancer are able to choose between involvement or not with this kind of CAM intervention. Global health could be improved by participating in this type of intervention. Implications for Practice: Choosing whether to be involved may be assisted by knowing the positive outcomes for some patients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to measure the temporal expression of osteogenic genes during the process of bone healing in low-intensity pulsed ultrasound (LIPUS) treated bone defects by means of histopathologic and real-time polymerase chain reaction (PCR) analysis. Animals were randomly distributed into two groups (n = 30): control group (bone defect without treatment) and LIPUS treated (bone defect treated with LIPUS). On days 7, 13 and 25 postinjury, 10 rats per group were sacrificed. Rats were treated with a 30 mW/cm(2) LIPUS. The results pointed out intense new bone formation surrounded by highly vascularized connective tissue presenting a slight osteogenic activity, with primary bone deposition was observed in the group exposed to LIPUS in the intermediary (13 days) and late stages of repair (25 days) in the treated animals. In addition, quantitative real-time polymerase chain reaction (RT-qPCR) showed an upregulation of bone morphogenetic protein 4 (BMP4), osteocalcin and Runx2 genes 7 days after the surgery. In the intermediary period, there was no increase in the expression. The expression of alkaline phosphatase, BMP4 and Runx2 was significantly increased at the last period. Our results indicate that LIPUS therapy improves bone repair in rats and upregulated osteogenic genes, mainly at the late stages of recovery. (E-mail: a.renno@unifesp.br) (C) 2010 Published by Elsevier Inc. on behalf of World Federation for Ultrasound in Medicine & Biology.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Hemotropic mycoplasmas, epicellular erythrocytic bacterial parasites lacking a cell wall, are the causative agents of infectious anemia in numerous mammalian species. The presence of hemotropic mycoplasmas in blood samples of neotropical and exotic wild canids and felids from Brazilian zoos were recorded using molecular techniques. Blood samples were collected from 146 Brazilian wild felids, 19 exotic felids, 3 European wolves (Canis lupus), and from 97 Brazilian wild canids from zoos in the Brazilian states of Sao Paulo and Mato Grosso and the Federal District. Using conventional polymerase chain reaction (PCR), this work found 22 (13%) wild felids positive to Candidatus Mycoplasma haemominutum [4 jaguars (Panthera onca); 3 pumas (Puma concolor); 10 ocelots (Leopardus pardalis); 2 jaguarondis (Puma yagouaroundi); and 3 little spotted cats (Leopardus tigrinus)]. Only one little spotted cat (Leopardus tigrinus) was positive to Mycoplasma haemofelis, and none was positive to Candidatus Mycoplasma turicensis. Two bush dogs (Speothos venaticus) were positive for a Mycoplasma sp. closely related to Candidatus Mycoplasma haematoparvum, and two European wolves were positive for a Mycoplasma sp. closely related to candidatus Mycoplasma haemominutum. This is the first study regarding the molecular detection of hemotropic mycoplasmas in wild canids.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The health sector requires continuous investments to ensure the improvement of products and services from a technological standpoint, the use of new materials, equipment and tools, and the application of process management methods. Methods associated with the process management approach, such as the development of reference models of business processes, can provide significant innovations in the health sector and respond to the current market trend for modern management in this sector (Gunderman et al. (2008) [4]). This article proposes a process model for diagnostic medical X-ray imaging, from which it derives a primary reference model and describes how this information leads to gains in quality and improvements. (C) 2010 Elsevier Ireland Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The therapeutic ultrasound (US) is one of the resources mostly used by physiotherapists; however the use of uncalibrated equipments results in inefficient or even harmful therapies to the patient. In this direction, the objective of this study was to evaluate the performance and the procedures of utilization and maintenance of US in use in clinics and Physical-therapy offices. A questionnaire with questions related to the procedures applied in service during the use of therapeutic ultrasound was applied to physiotherapists. The performance of 31 equipments of 6 different brands and 13 different models was evaluated according to the IEC 61689 norm. The parameters measured were: acoustic power; effective radiating area (AER); non-uniformity ratio of the beam (RBN); maximum effective intensity; acoustic frequency of operation, modulation factor and wave form on pulsate mode. As for the questionnaires, it was evident that the professionals are not concerned about the calibration of the equipment. The results demonstrated that only 32.3% of the equipments were in accordance with the norms for the variables power and effective radiation area. The frequency analysis indicated that 20% of the 3 MHz transducers and 12.5% of the 1 MHz contemplated the norms. In the pulsate mode, 12.7% presented relation rest/duration inside allowed limits. A great variation of the ultrasonic field was observed on the obtained images, which presented beams not centered, sometimes with bifurcation of its apex. The results allow concluding that, although used in therapeutic sessions with the population, none of the equipments presents all the analyzed variables inside technical norms. (C) 2010 Elsevier B. V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work describes the use of a large-aperture PVDF receiver in the measurement of liquid density and composite material elastic constants. The density measurement of several liquids is obtained with accuracy of 0.2% using a conventional NDE emitter transducer and a 70-mm-diameter, 52-mu m P(VDF-TrFE) membrane with gold electrodes. The determination of the elastic constants is based on the phase velocity measurement. Diffraction can lead to errors around 1% in velocity measurement when using alternatively the conventional pair of ultrasonic transducers (1-MHz frequency and 19-mm-diameter) operating in through-transmission mode, separated by a distance of 100 mm. This effect is negligible when using a pair of 10-MHz, 19-mm-diameter transducers. Nevertheless, the dispersion at 10 MHz can result in errors of about 0.5%, when measuring the velocity in composite materials. The use of an 80-mm diameter, 52-mu m-thick PVDF membrane receiver practically eliminates the diffraction effects in phase velocity measurement. The elastic constants of a carbon fiber reinforced polymer were determined and compared with the values obtained by a tensile test. (C) 2009 Elsevier B. V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The application of functionally graded material (FGM) concept to piezoelectric transducers allows the design of composite transducers without interfaces, due to the continuous change of property values. Thus, large improvements can be achieved, as reduction of stress concentration, increasing of bonding strength, and bandwidth. This work proposes to design and to model FGM piezoelectric transducers and to compare their performance with non-FGM ones. Analytical and finite element (FE) modeling of FGM piezoelectric transducers radiating a plane pressure wave in fluid medium are developed and their results are compared. The ANSYS software is used for the FE modeling. The analytical model is based on FGM-equivalent acoustic transmission-line model, which is implemented using MATLAB software. Two cases are considered: (i) the transducer emits a pressure wave in water and it is composed of a graded piezoceramic disk, and backing and matching layers made of homogeneous materials; (ii) the transducer has no backing and matching layer; in this case, no external load is simulated. Time and frequency pressure responses are obtained through a transient analysis. The material properties are graded along thickness direction. Linear and exponential gradation functions are implemented to illustrate the influence of gradation on the transducer pressure response, electrical impedance, and resonance frequencies. (C) 2009 Elsevier B. V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Gamma ray tomography experiments have been carried out to detect spatial patterns in the porosity in a 0.27 m diameter column packed with steel Rashig rings of different sizes: 12.6, 37.9, and 76 mm. using a first generation CT system (Chen et al., 1998). A fast Fourier transform tomographic reconstruction algorithm has been used to calculate the spatial variation over the column cross section. Cross-sectional gas porosity and solid holdup distribution were determinate. The values of cross-sectional average gas porosity were epsilon=0.849, 0.938 and 0.966 for the 12.6, 37.9, and 76 mm rings, respectively. Radial holdup variation within the packed bed has been determined. The variation of the circumferentially averaged gas holdup in the radial direction indicates that the porosity in the column wall region is a somewhat higher than that in the bulk region, due to the effect of the column wall. (C) 2009 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Intravascular ultrasound (IVUS) image segmentation can provide more detailed vessel and plaque information, resulting in better diagnostics, evaluation and therapy planning. A novel automatic segmentation proposal is described herein; the method relies on a binary morphological object reconstruction to segment the coronary wall in IVUS images. First, a preprocessing followed by a feature extraction block are performed, allowing for the desired information to be extracted. Afterward, binary versions of the desired objects are reconstructed, and their contours are extracted to segment the image. The effectiveness is demonstrated by segmenting 1300 images, in which the outcomes had a strong correlation to their corresponding gold standard. Moreover, the results were also corroborated statistically by having as high as 92.72% and 91.9% of true positive area fraction for the lumen and media adventitia border, respectively. In addition, this approach can be adapted easily and applied to other related modalities, such as intravascular optical coherence tomography and intravascular magnetic resonance imaging. (E-mail: matheuscardosomg@hotmail.com) (C) 2011 World Federation for Ultrasound in Medicine & Biology.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Functional magnetic resonance imaging (fMRI) has become an important tool in Neuroscience due to its noninvasive and high spatial resolution properties compared to other methods like PET or EEG. Characterization of the neural connectivity has been the aim of several cognitive researches, as the interactions among cortical areas lie at the heart of many brain dysfunctions and mental disorders. Several methods like correlation analysis, structural equation modeling, and dynamic causal models have been proposed to quantify connectivity strength. An important concept related to connectivity modeling is Granger causality, which is one of the most popular definitions for the measure of directional dependence between time series. In this article, we propose the application of the partial directed coherence (PDC) for the connectivity analysis of multisubject fMRI data using multivariate bootstrap. PDC is a frequency domain counterpart of Granger causality and has become a very prominent tool in EEG studies. The achieved frequency decomposition of connectivity is useful in separating interactions from neural modules from those originating in scanner noise, breath, and heart beating. Real fMRI dataset of six subjects executing a language processing protocol was used for the analysis of connectivity. Hum Brain Mapp 30:452-461, 2009. (C) 2007 Wiley-Liss, Inc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Chagas disease is a serious health problem in Latin America. Hidroxymethylnitrofurazone (NFOH) is a nitrofurazone prodrug more active than nitrofurazone against Trypanosoma cruzi. However, NFOH presents low aqueous solubility, high photodecomposition and high toxicity. The present work is focused on the characterization of an inclusion complex of NFOH in 2-hydroxypropyl-beta-cyclodextrin (HP-beta-CD). The complexation with HP-beta-CD was investigated using reversed-phase liquid chromatography, solubility isotherms and nuclear magnetic resonance. The retention behavior was analyzed on a reversed-phase C-18 column, using acetonitrile-water (20/80, v/v) as the mobile phase, in which HP-beta-CD was incorporated as a mobile phase additive. The decrease in the retention times with increasing concentrations of HP-beta-CD enables the determination of the apparent stability constant of the complex (K = 6.2 +/- 0.3 M-1) by HPLC. The solubility isotherm was studied and the value for the apparent stability constant (K = 7.9 +/- 0.2 M-1) was calculated. The application of continuous variation method indicated the presence of a complex with 1:1 NFOH:HP-beta-CD stoichiometry. The photostability study showed that the formation of an inclusion complex had a destabilizing effect on the photodecomposition of NFOH when compared to that of the ""free"" molecule in solution. The mobility investigation (by NMR longitudinal relaxation time) gives information about the complexation of NFOH with HP-beta-CD. In preliminary toxicity studies, cell viability tests revealed that inclusion complexes were able to decrease the toxic effect (p < 0.01) caused by NFOH. (c) 2008 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Sickle cell disease (SCD) is an inherited disorder caused by a single nucleotide substitution in the P-globin gene. The clinical heterogeneity observed in SCD patients has been attributed to environmental and genetic factors. The patients are subjected to increased oxidative stress, particularly during vaso-occlusive crises and acute chest pain. Another possible cause of oxidative stress in SCD is the high concentration of iron in the patients` plasma. The increase in oxidative stress could be a relevant risk factor for mutagenesis and carcinogenesis. Studies on the frequency of basal chromosomal aberrations in cultured lymphocytes from SCD patients have not been reported so far. In order to contribute to the understanding of the role of the different biomarkers and their relationship with the extremely variable clinical manifestation of SCD, we investigated the frequency of chromosome damage in peripheral lymphocytes from sickle cells patients and healthy controls. We found an increased frequency of chromosome damage and percentage of aberrant metaphases in these patients when compared with control subjects, even at basal values (p < 0.05). In the cytogenetic sensitivity assay, the results showed that these patients presented a marked decrease in the mitotic index values compared with healthy controls. Cisplatin-induced chromosomal damage in lymphocytes from these patients was significantly higher than the frequency measured in healthy controls. The results obtained in the present study showed that more investigations are needed in order to elucidate the susceptibility to genomic instability of SCD patients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Galectin-1 (Gal-1) is important in immune function and muscle regeneration, but its expression and localization in adult tissues and primary leukocytes remain unclear. To address this, we generated a specific monoclonal antibody against Gal-1, termed alpha hGal-1, and defined a sequential peptide epitope that it recognizes, which is preserved in human and porcine Gal-1, but not in murine Gal-1. Using alpha hGal-1, we found that Gal-1 is expressed in a wide range of porcine tissues, including striated muscle, liver, lung, brain, kidney, spleen, and intestine. In most types of cells, Gal-1 exhibits diffuse cytosolic expression, but in cells within the splenic red pulp, Gal-1 showed both cytosolic and nuclear localization. Gal-1 was also expressed in arterial walls and exhibited prominent cytosolic and nuclear staining in cultured human endothelial cells. However, human peripheral leukocytes and promyelocytic HL60 cells lack detectable Gal-1 and also showed very low levels of Gal-1 mRNA. In striking contrast, Gal-1 exhibited an organized cytosolic staining pattern within striated muscle tissue of cardiac and skeletal muscle and colocalized with sarcomeric actin on I bands. These results provide insights into previously defined roles for Gal-1 in inflammation, immune regulation and muscle biology.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A long-standing challenge of content-based image retrieval (CBIR) systems is the definition of a suitable distance function to measure the similarity between images in an application context which complies with the human perception of similarity. In this paper, we present a new family of distance functions, called attribute concurrence influence distances (AID), which serve to retrieve images by similarity. These distances address an important aspect of the psychophysical notion of similarity in comparisons of images: the effect of concurrent variations in the values of different image attributes. The AID functions allow for comparisons of feature vectors by choosing one of two parameterized expressions: one targeting weak attribute concurrence influence and the other for strong concurrence influence. This paper presents the mathematical definition and implementation of the AID family for a two-dimensional feature space and its extension to any dimension. The composition of the AID family with L (p) distance family is considered to propose a procedure to determine the best distance for a specific application. Experimental results involving several sets of medical images demonstrate that, taking as reference the perception of the specialist in the field (radiologist), the AID functions perform better than the general distance functions commonly used in CBIR.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A tandem ionization chamber was developed for quality control programs of X-ray equipment used in conventional radiography and mammography. A methodology for the use of the tandem chamber in the constancy check of diagnostic X-ray beam qualities was established. The application at a medical X-ray imaging facility of this established methodology is presented. The use of the tandem chamber in the constancy check of diagnostic X-ray beam qualities is a useful method to control the performance of the X-ray equipment. (c) 2008 Elsevier Ltd. All rights reserved.