100 resultados para eggshell quality
Resumo:
Objective: To determine whether basal levels of follicle-stimulating hormone (FSH) and anti-mullerian hormone (AMH), antral follicle count (AFC), and the numbers of dominant follicles, oocytes, and mature oocytes retrieved after ovarian stimulation differed between infertile women with endometriosis and healthy women undergoing assisted reproduction techniques (ART). Method: Of 77 consecutive ART candidates, 27 were infertile and had endometriosis. A male factor caused the infertility of the other 50, who acted as controls. Results: The AMH and AFC levels were similar in the 2 groups. The FSH levels were higher (8.28 mIU/ML [range, 5.25-24.1 mIU/ML] vs 5.91 mIU/mL [range, 2.47-18.7 mIU/ML]; P<0.01) in the study group. And the numbers of retrieved (n = 5 [range, 0-12] vs n = 9 [range, 0-27]; P<0.05) and mature oocytes (n = 4 [range, 0-11] vs n = 5 [range, 0-16]; P<0.05) were less in the study group. Conclusion: Because AMH levels were unchanged, endometriosis seems not to damage the primordial pool of follicles and oocytes, but to lessen the quality of the ovarian response to the hCG injection. Basal FSH levels may be of value in predicting ART success in women with the disease. (C) 2010 International Federation of Gynecology and Obstetrics. Published by Elsevier Ireland Ltd. All rights reserved.
Resumo:
Objective: To assess the impact of the mean oocyte diameter (MOD) on occurrence of fertilization and embryo quality in assisted reproduction cycles. Design: Prospective observational study. Setting: Sector of Human Reproduction of the University Hospital, Faculty of Medicine of Ribeirao Preto, University of Sao Paulo (HCFMRP-USP). Patient(s): Thirty-five women undergoing intracytoplasmic sperm injection (ICSI) at the University Hospital of Ribeirao Preto from May to October 2007. Intervention(s): MOD assessment. Main Outcome Measure(s): Occurrence of fertilization and qualitative embryo classification on 2nd and 3rd day after ICSI. Result(s): We divided 160 metaphase II oocytes according to MOD into groups A (MOD below the 25th percentile), B (MOD between 25th and 75th percentile), and C (MOD above the 75th percentile). There was no statistically significant association between MOD and the occurrence of fertilization or the qualitative embryo classification on days 2 and 3. There was no statistically significant difference between groups regarding number of cells or the qualitative embryo classification on days 2 and 3. Conclusion(s): The MOD of mature oocytes does not seem to be related to the occurrence of fertilization or to the developmental quality of human embryos on days 2 and 3 after ICSI. (Fertil Steril(R) 2010;93:621-5. (C)2010 by American Society for Reproductive Medicine.)
Resumo:
Chronic pelvic pain (CPP) is a common and complex disease whose cause is often clinically inexplicable, with consequent difficulty in diagnosis and treatment. Patients with CPP have high levels of anxiety and depression, with a consequent impairment of their quality of life. The objective of this study was to determine the prevalence of anxiety and depression and their impact on the quality of life of women with CPP. A cross-sectional controlled study was conducted on 52 patients with CPP and 54 women without pain. Depression and anxiety were evaluated by the Hospital Anxiety and Depression Scale, and quality of life was evaluated by the World Health Organization Quality of life Whoqol-bref questionnaire. Data were analysed statistically by the Mann-Whitney U-test, the Fisher exact test, chi-square test and Spearman correlation test. The prevalence of anxiety was 73% and 37% in the CPP and control groups, respectively, and the prevalence of depression was 40% and 30% respectively. Significant differences between groups were observed in the physical, psychological and social domains. Patients with higher anxiety and depression scores present lower quality of life scores. The fact that DPC is a syndromic complex, many patients enter a chronic cycle of search for improvement of medical symptoms. The constant presence of pain may be responsible for affective changes in dynamics, family, social and sexual. Initially the person is facing the loss of a healthy body and active, to a state of dependence and limitations. In this study, patients with higher scores of anxiety and depression scores had lower quality of life and patients with lower scores of anxiety and depression had scores of quality of life. These results show that perhaps the depression and anxiety may be related to the negative impact on quality of life of these patients. In view of this association, we emphasise the importance of a specific approach to the treatment of anxiety and depression together with clinical treatment to improve the quality of life of these patients.
Resumo:
Objectives: To evaluate the influence of the morphology of the first polar body (PB) on intracytoplasmic sperm injection (ICSI) outcomes. Methods: The morphology of the first PB was assessed in 3177 metaphase 11 oocytes and classified as: intact and normal size, fragmented, or enlarged size. The rates of fertilization, cleavage, and embryo quality were evaluated on day 2. Results: The rates of fertilization, cleavage, and formation of good quality embryos resulting from the insemination of oocytes with an enlarged first PB (20.7%, 18.7%, and 5.0%, respectively) were significantly lower than those for oocytes with an intact first PB of normal size (70.8%, 62.5%, and 19%, respectively) or a fragmented first PB (69.7%, 60.5%, and 17.1%, respectively). Rates did not differ significantly between oocytes with an intact first PB of normal size and oocytes with a fragmented first PB (P>0.05). Conclusions: The presence of an enlarged PB is related to poorer rates of fertilization, cleavage, and top quality embryos. However, identification of first PB fragmentation does not seem to interfere with ICSI outcomes. (C) 2008 International Federation ofGynecology and Obstetrics. Published by Elsevier Ireland Ltd. All rights reserved.
Resumo:
Background: Examination of the epidemiology and timing of trauma deaths has been deemed a useful method to evaluate the quality of trauma care. Objective: The purpose of this study was to evaluate the quality of trauma care in a regional trauma system and in a university hospital in Brazil by comparing the timing of deaths in the studied prehospital and in-hospital settings to those published for trauma systems in other areas. Methods: We analyzed the National Health Minister`s System of Deaths Information for the prehospital mortality and we retrospectively collected the demographics, timelines, and trauma severity scores of all in-hospital patients who died after admission through the Emergency Unit of Hospital das Clinicas de Ribeirao Preto between 2000 and 2001. Results. During the study period, there were 787 trauma fatalities in the city: 448 (56.9%) died in the prehospital setting and 339 (43.1%) died after being admitted to a medical facility. In 2 years, 238 trauma deaths occurred in the studied hospital, and we found a complete clinical set of data for 224 of these patients. The majority of deaths in the prehospital setting were caused by penetrating injuries (66.7%), whereas in-hospital mortality was mainly because of blunt traumas (59.1%). The largest number of in-hospital deaths occurred beyond 72 hours of stay (107 patients-47%). Conclusions: The region studied showed some deficiencies in prehospital and in-hospitals settings, in particular in the critical care and short-term follow-up of trauma patients when compared with the literature. Particularly, the late mortality may be related to training and human resources deficiency. Based on the timeline of trauma deaths, we can suggest that the studied region needs improvements in the prehospital trauma system and in hospital critical care.
Resumo:
Quality of life (QOL) has been extensively studied in clinical trials and in research on chronic degenerative diseases and dementia. The aim of this study was to assess the reliability and construct validity of the Brazilian version of the QOL scale in Alzheimer`s disease (AD; QOL-AD). The QOL-AD was administered to 60 patients with mild or moderate AD and to their caregivers. The construct validation was accomplished through correlations amongst total scores of patients` and caregivers` reports on patients` quality of life (PQOL and C-PQOL, respectively), and data related to cognitive impairment, depressive symptoms, functional performance, behavioral disturbances and a generic instrument of quality of life (WHOQOL-brief), as well as correlation of total score of caregivers` reports on their own quality of life (CQOL) with the measurements cited above, QOL-AD patient reports, and depressive symptoms. The reliability was high for PQOL, C-PQOL, and CQOL versions (Cronbach`s alpha = 0.80, 0.83, and 0.86, respectively). We observed significant correlations in the construct validity of all three versions regarding the variables associated with the disease and also with WHOQOL-brief. The scale took, on average, six min for each version. The results indicate reliability and construct validity of the Brazilian version of the QOL-AD in the studied sample.
Resumo:
Methods. aEuro integral Thirty mothers of disabled children participated in the study. The control group comprised of 18 healthy mothers of children without disabilities. All mothers agreed to participate in the study. They completed the evaluation forms of the SF-36 health survey, a well-documented, self-administered QOL scoring system. Results. aEuro integral The results of our study support the premise that mothers of children with CP, as a group, have poorer QOL than mothers of not disabled children. Conclusions. aEuro integral We also observed that mothers of children with CP and epilepsy have poorer QOL than mothers of children with CP without epilepsy.
Resumo:
Objectives: To verify the consequences of implant-supported fixed oral rehabilitation on the quality of life (QL) of elderly individuals. Material and methods: Fifteen patients were studied, being 10 females and five males; all were aged > 60 years, were completely edentulous, wore removable dentures on both arches, and were treated with implant-supported fixed dentures. Three QL questionnaires were applied, two related to the oral conditions (Oral Impact on Daily Performance - OIDP - and Oral Health Impact Profile, short version - OHIP-14) and one dealing with global aspects (World Health Organization Quality of Life - WHOQOL-BREF), before 3, 6, and 18 months after surgical placement of implants. Results: Scores in the OIDP and OHIP-14 questionnaires were better after dental treatment. The WHOQOL-BREF was less sensitive, confirming the higher reliability of specific questionnaires (focal) compared with general questions in such situations. Conclusion: Treatment with implant-supported fixed prostheses improved QL in the elderly; these effects are better detected by specific instruments focused on the subject.
Resumo:
Introduction: Recently developed portable dental X-ray units increase the mobility of the forensic odontologists and allow more efficient X-ray work in a disaster field, especially when used in combination with digital sensors. This type of machines might also have potential for application in remote areas, military and humanitarian missions, dental care of patients with mobility limitation, as well as imaging in operating rooms. Objective: To evaluate radiographic image quality acquired by three portable X-ray devices in combination with four image receptors and to evaluate their medical physics parameters. Materials and methods: Images of five samples consisting of four teeth and one formalin-fixed mandible were acquired by one conventional wall-mounted X-ray unit, MinRay (R) 60/70 kVp, used as a clinical standard, and three portable dental X-ray devices: AnyRay (R) 60 kVp, Nomad (R) 60 kVp and Rextar (R) 70 kVp, in combination with a phosphor image plate (PSP), a CCD, or a CMOS sensor. Three observers evaluated images for standard image quality besides forensic diagnostic quality on a 4-point rating scale. Furthermore, all machines underwent tests for occupational as well as patient dosimetry. Results: Statistical analysis showed good quality imaging for all system, with the combination of Nomad (R) and PSP yielding the best score. A significant difference in image quality between the combination of the four X-ray devices and four sensors was established (p < 0.05). For patient safety, the exposure rate was determined and exit dose rates for MinRay (R) at 60 kVp, MinRay (R) at 70 kVp, AnyRay (R), Nomad (R) and Rextar (R) were 3.4 mGy/s, 4.5 mGy/s, 13.5 mGy/s, 3.8 mGy/s and 2.6 mGy/s respectively. The kVp of the AnyRay (R) system was the most stable, with a ripple of 3.7%. Short-term variations in the tube output of all the devices were less than 10%. AnyRay (R) presented higher estimated effective dose than other machines. Occupational dosimetry showed doses at the operator`s hand being lowest with protective shielding (Nomad (R): 0.1 mu Gy). It was also low while using remote control (distance > 1 m: Rextar (R) < 0.2 mu Gy, MinRay (R) < 0.1 mu Gy). Conclusions: The present study demonstrated the feasibility of three portable X-ray systems to be used for specific indications, based on acceptable image quality and sufficient accuracy of the machines and following the standard guidelines for radiation hygiene. (C) 2010 Elsevier Ireland Ltd. All rights reserved.
Resumo:
The aim of this study was to analyze if the presence of impacted third molars, and their positions in the mandibular angle, can change the bone quality in this area, considering the measure of the cortical thickness in this region as representative or not for mandible fracture risk. Software was used to analyze 50 digital images from panoramic radiographs of patients who had one or two impacted third molars in the mandible, and 30 digital images of patients with agenesis of the mandibular third molar. The thickness of the cortical region of the mandible was measured; it was possible to draw a parallel line to the posterior portion of the mandible and a parallel line to the body of this bone on each side of the image. At the intersection of these lines near the distal portion of the second molar, another line was set up to serve as reference in the cortical thickness measurement. It could be concluded that the cortical thickness of the mandibular angle in male patients without impacted third molars was greater than the thickness in patients with these teeth, and no difference in thickness was found for the female group.