100 resultados para Technological intensity


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Energy intensity of the total primary energy supply (TPES), total final energy consumption (TFC) and LOSSES in the conversion from TPES to TFC were analyzed for the World, OECD and Rest of the World (ROW) countries. LOSSES increased significantly for all groups of countries due to the increase of electricity production from coal in the period studied (1971-2008). Electricity share final consumption almost doubled, increasing from 8.8% to 17.2% in the period studied. However the energy intensity of LOSSES remained practically constant, which reflects the fact that the efficiency of electricity generation from coal (the main source of electricity) remained practically constant in that period. Despite the attractiveness of end-use devices running on electricity such as computers, which is typical of modern societies, the CO(2) emissions are bound to increase unless coal is replaced by less carbon emitting sources such as natural gas, renewables and nuclear energy. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Low-density lipoprotein (LDL) particles are the major cholesterol-carrying lipoprotein in the human circulation from the liver to peripheral tissues. High levels of LDL-Cholesterol (LDL-C) are known risk factor for the development of coronary artery disease (CAD). The most common approach to determine the LDLC in the clinical laboratory involves the Friedewald formula. However, in certain situations, this approach is inadequate. In this paper we report on the enhancement on the Europium emission band of Europium chlortetracycline complex (CTEu) in the presence of LDL. The emission intensity at 615 nm of the CTEu increases with increasing amounts of LDL. This phenomenon allowed us to propose a method to determine the LDL concentration in a sample composed by an aqueous solution of LDL. With this result we obtained LDL calibration curve, LOD (limit of detection) of 0.49 mg/mL and SD (standard deviation) of 0.003. We observed that CTEu complex provides a wider dynamic concentration-range for LDL determination than that from Eu-tetracycline previously. The averaged emission lifetimes of the CTEu and CTEu with LDL (1.5 mg/mL) complexes were measured as 15 and 46 Its, respectively. Study with some metallic interferents is presented. (C) 2010 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work describes two similar methods for calculating gamma transition intensities from multidetector coincidence measurements. In the first one, applicable to experiments where the angular correlation function is explicitly fitted, the normalization parameter from this fit is used to determine the gamma transition intensities. In the second, that can be used both in angular correlation or DCO measurements, the spectra obtained for all the detector pairs are summed up, in order to get the best detection statistics possible, and the analysis of the resulting bidimensional spectrum is used to calculate the transition intensities; in this method, the summation of data corresponding to different angles minimizes the influence of the angular correlation coefficient. Both methods are then tested in the calculation of intensities for well-known transitions from a (152)Eu standard source, as well as in the calculation of intensities obtained in beta-decay experiments with (193)Os and (155)Sm sources, yielding excellent results in all these cases. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to investigate the mechanisms whereby low-intensity laser therapy may affect the severity of oral mucositis. A hamster cheek pouch model of oral mucositis was used with all animals receiving intraperitoneal 5-fluorouracil followed by surface irritation. Animals were randomly allocated into three groups and treated with a 35 mW laser, 100 mW laser, or no laser. Clinical severity of mucositis was assessed at four time-points by a blinded examiner. Buccal pouch tissue was harvested from a subgroup of animals in each group at four time-points. This tissue was used for immunohistochemistry for cyclooxygenase-2 (COX-2), vascular endothelial growth factor (VEGF), and factor VIII (marker of microvessel density) and the resulting staining was quantified. Peak severity of mucositis was reduced in the 35 mW laser group as compared to the 100 mW laser and control groups. This reduced peak clinical severity of mucositis in the 35 mW laser group was accompanied by a significantly lower level of COX-2 staining. The 100 mW laser did not have an effect on the severity of clinical mucositis, but was associated with a decrease in VEGF levels at the later time-points, as compared to the other groups. There was no clear relationship of VEGF levels or microvessel density to clinical mucositis severity. The tissue response to laser therapy appears to vary by dose. Low-intensity laser therapy appears to reduce the severity of mucositis, at least in part, by reducing COX-2 levels and associated inhibition of the inflammatory response.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ancient potteries usually are made of the local clay material, which contains relatively high concentration of iron. The powdered samples are usually quite black, due to magnetite, and, although they can be used for thermoluminescene (TL) dating, it is easiest to obtain better TL reading when clearest natural or pre-treated sample is used. For electron paramagnetic resonance (EPR) measurements, the huge signal due to iron spin-spin interaction, promotes an intense interference overlapping any other signal in this range. Sample dating is obtained by dividing the radiation dose, determined by the concentration of paramagnetic species generated by irradiation, by the natural dose so as a consequence, EPR dating cannot be used, since iron signal do not depend on radiation dose. In some cases, the density separation method using hydrated solution of sodium polytungstate [Na(G)(H(2)W(12)O(40))center dot H(2)O] becomes useful. However, the sodium polytungstate is very expensive in Brazil: hence an alternative method for eliminating this interference is proposed. A chemical process to eliminate about 90% of magnetite was developed. A sample of powdered ancient pottery was treated in a mixture (3:1:1) of HCI, HNO(3) and H(2)O(2) for 4 h. After that, it was washed several times in distilled water to remove all acid matrixes. The original black sample becomes somewhat clearer. The resulting material was analyzed by plasma mass spectrometry (ICP-MS), with the result that the iron content is reduced by a factor of about 9. In EPR measurements a non-treated natural ceramic sample shows a broad spin-spin interaction signal, the chemically treated sample presents a narrow signal in g= 2.00 region, possibly due to a radical of (SiO(3))(3-), mixed with signal of remaining iron [M. lkeya, New Applications of Electron Spin Resonance, World Scientific, Singapore, 1993, p. 285]. This signal increases in intensity under -gamma-irradiation. However, still due to iron influence, the additive method yielded too old age-value. Since annealing at 300 degrees C, Toyoda and Ikeya IS. Toyoda, M. Ikeya, Geochem. J. 25 (1991) 427-445] states that E `(1)-signal with maximum intensity is obtained, while annealing at 400 degrees C E`(1)-signal is completely eliminated, the subtraction of the second one from 300 degrees C heat-treated sample isolate E`(1)-like signal. Since this is radiation dose-dependent, we show that now EPR dating becomes possible. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose Acute myelogenous leukemia (AML) and myelodysplastic syndrome (MDS) primarily afflict older individuals. Hematopoietic cell transplantation (HCT) is generally not offered because of concerns of excess morbidity and mortality. Reduced-intensity conditioning (RIC) regimens allow increased use of allogeneic HCT for older patients. To define prognostic factors impacting long-term outcomes of RIC regimens in patients older than age 40 years with AML in first complete remission or MDS and to determine the impact of age, we analyzed data from the Center for International Blood and Marrow Transplant Research (CIBMTR). Patients and Methods We reviewed data reported to the CIBMTR (1995 to 2005) on 1,080 patients undergoing RIC HCT. Outcomes analyzed included neutrophil recovery, incidence of acute or chronic graft-versus-host disease (GVHD), nonrelapse mortality (NRM), relapse, disease-free survival (DFS), and overall survival (OS). Results Univariate analyses demonstrated no age group differences in NRM, grade 2 to 4 acute GVHD, chronic GVHD, or relapse. Patients age 40 to 54, 55 to 59, 60 to 64, and >= 65 years had 2-year survival rates as follows: 44% (95% Cl, 37% to 52%), 50% (95% Cl, 41% to 59%), 34% (95% Cl, 25% to 43%), and 36% (95% Cl, 24% to 49%), respectively, for patients with AML (P = .06); and 42% (95% Cl, 35% to 49%), 35% (95% Cl, 27% to 43%), 45% (95% Cl, 36% to 54%), and 38% (95% Cl, 25% to 51%), respectively, for patients with MDS (P = .37). Multivariate analysis revealed no significant impact of age on NRM, relapse, DFS, or OS (all P>.3). Greater HLA disparity adversely affected 2-year NRM, DFS, and OS. Unfavorable cytogenetics adversely impacted relapse, DFS, and OS. Better pre-HCT performance status predicted improved 2-year OS. Conclusion With these similar outcomes observed in older patients, we conclude that older age alone should not be considered a contraindication to HCT.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Phototherapy improves cellular activation which is an important factor for the treatment of cellulite. The objective of this research was to develop and evaluate the effects of a new (noninvasive and nonpharmacological) clinical procedure to improve body aesthetics: infrared-LED (850 nm) plus treadmill training. Twenty women (25-55 years old) participated in this study. They were separated in two groups: the control group, which carried out only the treadmill training (n = 10), and the LED group, with phototherapy during the treadmill training (n - 10). The training was performed for 45 minutes twice a week over 3 months at intensities between 85% and 90% maximal heart rate (HR(max)). The irradiation parameters were 39 mW/cm(2) and a fluence of 106 J/cm(2). The treatment was evaluated by interpreting body composition parameters, photographs and thermography. This was primarily a treatment for cellulite with a reduction of saddlebag and thigh circumference. At the same time, the treadmill training prevented an increase of body fat, as well as the loss of lean mass. Moreover, thermal images of the temperature modification of the thighs are presented. These positive effects can result in a further improvement of body aesthetics using infrared-LED together with treadmill training.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study evaluated the process of ablation produced by a Ti:Sapphire femtosecond laser under different average powers taking place at the enamel/dentin interface. Based on the geometry of ablated microcavities the effective intensity for ablation was obtained. This study shows the validity for the local effective intensity analysis and allows a quantification of the variation in the ablation geometry taking place at the interface of two naturally different materials. It shows that the variation of the diameter of the ablated region as a function of the cavity depth comes essentially from a mechanism of effective intensity attenuation, as a result of a series of complex effects. Additionally, our data are sufficient to predict that a discontinuity on the ablation profile will occur on the interface between two biological media: enamel-dentin, showing a suddenly jump on the ablated cavity dimensions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Time-dependent fluctuations in surface-enhanced Raman scattering (SERS) intensities were recorded from a roughened silver electrode immersed in diluted solutions of rhodamine 6G (R6G) and congo red (CR). These fluctuations were attributed to a small number of SERS-active molecules probing regions of extremely high electromagnetic field (hot spots) at the nanostructured surface. The time-dependent distribution of SERS intensities followed a tailed statistics at certain applied potentials, which has been linked to single-molecule dynamics. The shape of the distribution was reversibly tuned by the applied voltage. Mixtures of both dyes, R6G and CR, at low concentrations were also investigated. Since R6G is a cationic dye and CR is an anionic dye, the statistics of the SERS intensity distribution of either dye in a mixture were independently controlled by adjusting the applied potential. The potential-controlled distribution of SERS intensities was interpreted by considering the modulation of the surface coverage of the adsorbed dye by the interfacial electric field. This interpretation was supported by a two-dimensional Monte Carlo simulation that took into account the time evolution of the surface configuration of the adsorbed species and their probability to populate a hypothetical hot spot. The potential-controlled SERS dynamics reported here is a first step toward the spectroelectrochemical investigation of redox processes at the single-molecule level by SERS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We employed the Density Functional Theory along with small basis sets, B3LYP/LANL2DZ, for the study of FeTIM complexes with different pairs of axial ligands (CO, H(2)O, NH(3), imidazole and CH(3)CN). These calculations did not result in relevant changes of molecular quantities as bond lengths, vibrational frequencies and electronic populations supporting any significant back-donation to the carbonyl or acetonitrile axial ligands. Moreover, a back-donation mechanism to the macrocycle cannot be used to explain the observed changes in molecular properties along these complexes with CO or CH(3)CN. This work also indicates that complexes with CO show smaller binding energies and are less stable than complexes with CH(3)CN. Further, the electronic band with the largest intensity in the visible region (or close to this region) is associated to the transition from an occupied 3d orbital on iron to an empty pi* orbital located at the macrocycle. The energy of this Metal-to-Ligand Charge Transfer (MLCT) transition shows a linear relation to the total charge of the macrocycle in these complexes as given by Mulliken or Natural Population Analysis (NPA) formalisms. Finally, the macrocycle total charge seems to be influenced by the field induced by the axial ligands. (C) 2011 Elsevier Ltd. All rights reserved.