98 resultados para Spinning Finite Elements


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Neutron activation analysis was applied to assess trace element concentrations in brain tissues from normal (n = 21) and demented individuals (n = 21) of both genders aged more than 50 years. Concentrations of the elements Br, Fe, K, Na, Rb, Se and Zn were determined. Comparisons were made between the results obtained for the hippocampus and frontal cortex tissues, as well as, those obtained in brains of normal and demented individuals. Certified reference materials, NIST 1566b Oyster Tissue and NIST 1577b Bovine Liver were analyzed for quality of the analytical results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The sciarid DNA puff C4 BhC4-1 gene is amplified and transcribed in salivary glands at the end of the larval stage. In transgenic Drosophila, the BhC4-1 promoter drives transcription in prepupal salivary glands and in the ring gland of late embryos. A bioinformatics analysis has identified 162 sequences similar to distinct regions of the BhC4-1 proximal promoter, which are predominantly located either in 5` or 3` regions or introns in the Drosophila melanogaster genome. A significant number of the identified sequences are found in the regulatory regions of Drosophila genes that are expressed in the salivary gland. Functional assays in Drosophila reveal that the BhC4-1 proximal promoter contains both a 129 bp (-186/-58) salivary gland enhancer and a 67 bp (-253/-187) ring gland enhancer that drive tissue specific patterns of developmentally regulated gene expression, irrespective of their orientation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In recent years, there has been increasing fish consumption in Brazil, largely due to the popularity of Japanese cuisine. No study, however, has previously assessed the presence of inorganic contaminants in species used in the preparation of Japanese food. In this paper, we determined total arsenic, cadmium, chromium, total mercury, and lead contents in 82 fish samples of Tuna (Thunnus thynnus), Porgy (Pagrus pagrus), Snook (Centropomus sp.), and Salmon (Salmo salar) species marketed in Sao Paulo (Brazil). Samples were mineralized in HNO(3)/H(2)O(2) for As, Cd, Cr and Pb, and in HNO(3)/H(2)SO(4)/V(2)O(5) for Hg. Inorganic contaminants were determined after the validation of the methodology using Inductively Coupled Plasma Optical Emission Spectrometry (ICP OES); and for Hg, an ICP-coupled hydride generator was used. Concentration ranges for elements analyzed in mg kg(-1) (wet base) were as follows: Total As (0.11-10.82); Cd (0.005-0.047); Cr (0.008-0.259); Pb (0.026-0.481); and total Hg (0.0077-0.9681). As and Cr levels exceeded the maximum limits allowed by the Brazilian law (1 and 0.1 mg kg(-1)) in 51.2 and 7.3% of the total samples studied, respectively. The most contaminated species were porgy (As = 95% and Cr = 10%) and tuna (As 91% and Cr = 10%). An estimation of As, Cd, Pb, and Hg weekly intake was calculated considering a 60 kg adult person and a 350 g consumption of fish per week, with As and Hg elements presenting the highest contribution on diets reaching 222% of provisional tolerable weekly intake (PTWI) for As in porgy and 41% of PTWI for Hg in tuna. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It has been speculated that the homeopathic treatment of sperm cells in order to improve semen quality could be promising. However, few data is available and its use in spermatozoa requires investigation. It is well established that mitochondrial membrane potential is an important viability parameter of spermatozoa and it is intimately related to reproductive efficiency. In this manner, new technologies in order to improve the activity of sperm cells and, finally, the fecundity of swine herds are of extremely importance. Due to the lack of knowledge of homeopathic treatment effect on spermatozoa, the aim of the present study was to verify the effect of three different homeopathic treatments on viability of boar sperm cells. Three homeopathic treatments composed by Pulsatila CH6, Pulsatila and Avena CH6, Avena CH6 and one control treatment (sucrose) were added to diluted boar semen, which were cooled for 24 or 48 h. Interestingly, no positive effect of homeopathic treatments was observed over semen viability. However, it was demonstrated that the 24 h of cooling storage provided more viable sperm cells when compared to the 48-h period. This effect of storage period on sperm viability was assessed by intact plasmatic membrane, intact acrosome and mitochondrial membrane potential evaluation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective. To evaluate the biaxial and short-beam uniaxial strength tests applied to resin composites based upon their Weibull parameters, fractographic features and stress distribution. Methods. Disk- (15 mm x 1 mm) and beam-shaped specimens (10 mm x 2 mm x 1 mm) of three commercial composites (Concept/Vigodent, CA; Heliomolar/Ivoclar-Vivadent, HE; Z250/3M ESPE, FZ) were prepared. After 48h dry storage at 37 degrees C, disks and beams were submitted to piston-on-three-balls (BI) and three-point bending (UNI) tests, respectively. Data were analyzed by Weibull statistics. Fractured surfaces were observed under stereomicroscope and scanning electron microscope. Maximum principal stress (sigma(1)) distribution was determined by finite element analysis (FEA). Maximum sigma(1-BI) and sigma(1-UNI) were compared to FZ strengths calculated by applying the average failure loads to the analytical equations (sigma(a-BI) and sigma(a-UNI)). Results. For BI, characteristic strengths were: 169.9a (FZ), 122.4b (CA) and 104.8c (HE), and for UNI were: 160.3a (FZ), 98.2b (CA) and 91.6b (HE). Weibull moduli ( m) were similar within the same test. CA and HE presented statistically higher m for BI. Surface pores ( BI) and edge flaws ( UNI) were the most frequent fracture origins. sigma(1-BI) was 14% lower than sigma(a-BI.) sigma(1-UNI) was 43% higher than sigma(a-UNI). Significance. Compared to the short-beam uniaxial test, the biaxial test detected more differences among composites and displayed less data scattering for two of the tested materials. Also, biaxial strength was closer to the material`s strength estimated by FEA. (C) 2009 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Upper premolars restored with endodontic posts present a high incidence of vertical root fracture (VRF). Two hypotheses were tested: (1) the smaller mesiodistal diameter favors stress concentration in the root and (2) the lack of an effective bonding between root and post increases the risk of VRF. Using finite element analysis, maximum principal stress was analyzed in 3-dimensional intact upper second premolar models. From the intact models, new models were built including endodontic posts of different elastic modulus (E = 37 or E = 200 GPa) with circular or oval cross-section, either bonded or nonbonded to circular or oval cross-section root canals. The first hypothesis was partially confirmed because the conditions involving nonbonded, low-modulus posts showed lower tensile stress for oval canals compared to circular canals. Tensile stress peaks for the nonbonded models were approximately three times higher than for the bonded or intact models, therefore confirming the second hypothesis. (J Endod 2009;35:117-120)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Stress distributions in torsion and wire-loop shear tests were compared using three-dimensional (3-D) linear-elastic finite element method, in an attempt to predict the ideal conditions for testing adhesive strength of dental resin composites to dentin. The torsion test presented lower variability in stress concentration at the adhesive interface with changes in the proportion adhesive thickness/resin composite diameter, as well as lower variability with changes in the resin composite elastic modulus. Moreover, the torsion test eliminated variability from changes in loading distance, and reduced the cohesive fracture tendency in the dentin. The torsion test seems to be more appropriate than wire-loop shear test for testing the resin composite-tooth interface strength. (c) Koninklijke Brill NV, Leiden, 2009

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The objective of this study was to evaluate the stress on the cortical bone around single body dental implants supporting mandibular complete fixed denture with rigid (Neopronto System-Neodent) or semirigid splinting system (Barra Distal System-Neodent). Methods and Materials: Stress levels on several system components were analyzed through finite element analysis. Focusing on stress concentration at cortical bone around single body dental implants supporting mandibular complete fixed dentures with rigid ( Neopronto System-Neodent) or semirigid splinting system ( Barra Distal System-Neodent), after axial and oblique occlusal loading simulation, applied in the last cantilever element. Results: The results showed that semirigid implant splinting generated lower von Mises stress in the cortical bone under axial loading. Rigid implant splinting generated higher von Mises stress in the cortical bone under oblique loading. Conclusion: It was concluded that the use of a semirigid system for rehabilitation of edentulous mandibles by means of immediate implant-supported fixed complete denture is recommended, because it reduces stress concentration in the cortical bone. As a consequence, bone level is better preserved, and implant survival is improved. Nevertheless, for both situations the cortical bone integrity was protected, because the maximum stress level findings were lower than those pointed in the literature as being harmful. The maximum stress limit for cortical bone (167 MPa) represents the threshold between plastic and elastic state for a given material. Because any force is applied to an object, and there is no deformation, we can conclude that the elastic threshold was not surpassed, keeping its structural integrity. If the force is higher than the plastic threshold, the object will suffer permanent deformation. In cortical bone, this represents the beginning of bone resorption and/or remodeling processes, which, according to our simulated loading, would not occur. ( Implant Dent 2010; 19:39-49)