98 resultados para Solid-contact electrodes
Resumo:
There remains a lack of solid evidence showing whether transcranial stimulation with weak alternating current (transcranial alternating current stimulation, tACS) can in fact induce significant neurophysiological effects. Previously, a study in which tACS was applied for 2 and 5 min with current density = 0.16-0.25 A/m(2) was unable to show robust effects on cortical excitability. Here we applied tACS at a significantly higher current density (0.80 A/m(2)) for a considerably longer duration (20 min) and were indeed able to demonstrate measurable changes to cortical excitability. Our results show that active 15 Hz tACS of the motor cortex (electrodes placed at C3 and C4) significantly diminished the amplitude of motor evoked potentials and decreased intracortical facilitation (ICF) as compared to baseline and sham stimulation. In addition, we show that our method of sham tACS is a reliable control condition. These results support the notion that AC stimulation with weak currents can induce significant changes in brain excitability; in this case, 15 Hz tACS led to a pattern of inhibition of cortical excitability. We propose that tACS may have a dampening effect on cortical networks and perhaps interfere with the temporal and spatial summation of weak subthreshold electric potentials. (C) 2010 Elsevier Ireland Ltd. All rights reserved.
Resumo:
Decisions for intensive care unit (ICU) admissions in patients with advanced cancer are complex, and the knowledge of survival rates and prognostic factors are essential to these decisions. Ours objectives were to describe the short- and long-term survival of patients with metastatic solid cancer admitted to an ICU due to emergencies and to study the prognostic factors presented at ICU admission that could be associated with hospital mortality. We retrospectively analysed the charts of all patients with metastatic solid cancer admitted over a 1-year period. This gave a study sample of 83 patients. The ICU, hospital, 1-year and 2-year survival rates were 55.4%, 28.9%, 12.0% and 2.4% respectively. Thrombocytopenia (odds ratio 26.2; P = 0.006) and simplified acute physiology score (SAPS II) (odds ratio 1.09; P = 0.026) were independent factors associated with higher hospital mortality. In conclusion, the survival rates of patients with metastatic solid cancer admitted to the ICU due to emergencies were low, but of the same magnitude as other groups of cancer patients admitted to the ICU. The SAPS II score and thrombocytopenia on admission were associated with higher hospital mortality. The characteristics of the metastatic disease, such as number of organs with metastasis and central nervous system metastasis were not associated with the hospital mortality.
Resumo:
To obtain a high quality EMG acquisition, the signal must be recorded as far away as possible from muscle innervations and tendon zones, which are known to shift during dynamic contractions. This study describes a methodology, using commercial bipolar electrodes, to identify better electrode positions for superficial EMG of lower limb muscles during dynamic contractions. Eight female volunteers participated in this study. Myoelectric signals of the vastus lateralis, gastrocnemius medialis, peroneus longus and tibialis anterior muscles were acquired during maximum isometric contractions using bipolar electrodes. The electrode positions of each muscle were selected assessing SENIAM and then, other positions were located along the length of muscle up and down the SENIAM site. The raw signal (density), the linear envelopes, the RMS value, the motor point site, the position of the IZ and its shift during dynamic contractions were taken into account to select and compare electrode positions. For vastus lateralis and peroneus longus, the best sites were 66% and 25% of muscle length, respectively (similar to SENIAM location). The position of the tibialis anterior electrodes presented the best signal at 47.5% of its length (different from SENIAM location). The position of the gastrocnemius medialis electrodes was at 38% of its length and SENIAM does not specify a precise location for signal acquisition. The proposed method should be considered as another methodological step in every EMG study to guarantee the quality of the signal and subsequent human movement interpretations. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
Autopsy is a valuable tool in evaluating diagnostic accuracy. Solid malignancies may have a protracted presentation, and diagnosis frequently requires imaging and deep-sited biopsies; clinical and postmortem diagnosis discrepancies may occur in a high rate in these diseases. Here, we analyzed the occurrence of clinico-pathological discrepancies in the diagnoses of solid malignancies in a Brazilian academic hospital. We reviewed charts and autopsy reports of the patients that died from 2001 to 2003 with at least one solid neoplasm. Patients were classified in concordant and discordant cases regarding cancer diagnosis. Discordant cases were categorized in undiagnosed cases (no suspicion of cancer) and in misdiagnosed cases (clinical suspicion of cancer but incompletely diagnosed). Among the 264 patients with a single non-incidental solid neoplasm, the clinico-pathological discrepancy rate was 37.1%. Liver (22.5%), lung (19.4%), and pancreatic cancer (15.3%) were the most frequent malignancies in the discordant group. Misdiagnosis category comprised 68% of the discordant cases, i.e., there was no correct knowledge about the tumor primary site and/or the histological type during life. Our data show that a high rate of discrepancies occurs in solid malignancies. Autopsies may provide the basis for a better understanding of diagnostic deficiencies in different circumstances. (C) 2008 Elsevier GmbH. All rights reserved.
Resumo:
Reactive oxygen species oxidize proteins and modulate the proteasomal system in muscle-wasting cancer cachexia. On day 5 (D5), day 10 (D10), and day 14 (D14) after tumor implantation, skeletal muscle was evaluated. Carbonylated proteins and thiobarbituric acid reactive substances were measured. Chemiluminescence was employed for lipid hydroperoxide estimation. Glutathione, superoxide dismutase, and total radical antioxidant capacity were evaluated. The proteasomal system was assessed by mRNA atrogin-1 expression. Increased muscle wasting, lipid hydroperoxide, and superoxide dismutase, and decreased glutathione levels and total radical antioxidant capacity, were found on D5 in accordance with increased mRNA atrogin-1 expression. All parameters were significantly modified in animals treated with alpha-tocopherol. The elevation in aldehylde levels and carbonylated proteins observed on D10 were reversed by cc-tocopherol treatment. Oxidative stress may trigger signal transduction of the proteasomal system and cause protein oxidation. These pathways may be associated with the mechanism of muscle wasting that occurs in cancer cachexia. Muscle Nerve 42: 950-958, 2010
Resumo:
Stimulating neural electrodes are required to deliver charge to an environment that presents itself as hostile. The electrodes need to maintain their electrical characteristics (charge and impedance) in vivo for a proper functioning of neural prostheses. Here we design implantable multi-walled carbon nanotubes coating for stainless steel substrate electrodes, targeted at wide frequency stimulation of deep brain structures. In well-controlled, low-frequency stimulation acute experiments, we show that multi-walled carbon nanotube electrodes maintain their charge storage capacity (CSC) and impedance in vivo. The difference in average CSCs (n = 4) between the in vivo (1.111 mC cm(-2)) and in vitro (1.008 mC cm(-2)) model was statistically insignificant (p > 0.05 or P-value = 0.715, two tailed). We also report on the transcription levels of the pro-inflammatory cytokine IL-1 beta and TLR2 receptor as an immediate response to low-frequency stimulation using RT-PCR. We show here that the IL-1 beta is part of the inflammatory response to low-frequency stimulation, but TLR2 is not significantly increased in stimulated tissue when compared to controls. The early stages of neuroinflammation due to mechanical and electrical trauma induced by implants can be better understood by detection of pro-inflammatory molecules rather than by histological studies. Tracking of such quantitative response profits from better analysis methods over several temporal and spatial scales. Our results concerning the evaluation of such inflammatory molecules revealed that transcripts for the cytokine IL-1 beta are upregulated in response to low-frequency stimulation, whereas no modulation was observed for TLR2. This result indicates that the early response of the brain to mechanical trauma and low-frequency stimulation activates the IL-1 beta signaling cascade but not that of TLR2.
Resumo:
Purpose: Contact lens electrodes (CLEs) are frequently used to register electroretinograms (ERGs) in small animals such as mice or rats. CLEs are expensive to buy or difficult to be produced individually. In addition, CLE`s have been noticed to elicit inconstant results and they carry potential to injure the cornea. Therefore, a new electrode holder was constructed based on the clinically used DTL-electrode and compared to CLEs. Material and methods: ERGs were recorded with both electrode types in nine healthy Brown-Norway rats under scotopic conditions. For low intensity responses a Naka-Rushton function was fitted and the parameters V(max), k and n were analyzed. The a-wave, b-wave and oscillatory potentials were analyzed for brighter flash intensities (1-60 scot cd s/m(2)). Repeatability was assessed for both electrode types in consecutive measurements. Results: The new electrode holder was faster in setting up than the CLE and showed lower standard deviations. No corneal alterations were observed. Slightly higher amplitudes were recorded in most of the measurements with the new electrode holder (except amplitudes induced by 60 cd s/m(2)). A Bland-Altman test showed good agreement between the DTL holder and the CLE (mean difference 35.2 mu V (Holder-CLE)). Pearson`s correlation coefficient for test-retest-reliability was r = 0.783. Conclusions: The DTL holder was superior in handling and caused far less corneal problems than the CLE and produced comparable or better electrophysiological results. The minimal production costs and the possibility of adapting the DTL holder to bigger eyes, such as for dogs or rabbits, offers with broader application prospects. (C) 2010 Elsevier B.V. All rights reserved.
Resumo:
Objectives: To determine the differences between tympanic and extratympanic electrodes regarding recording technique, comfort and ease of execution of the exam, and quality of auditory potential tracings. Study Design: Prospective cross-section investigation. Methods: Determination of the summation potential/action potential (SP/AP) ratio by electrocochleography (EchoG) using tympanic and extratympanic electrodes and separate analysis of SP and AP regarding the amplitude recorded. Results: Twenty-three subjects (15 men and 8 women; mean age: 33.17 years) with normal tonal threshold audiometry were evaluated. EchoG analysis revealed no significant difference between the two tympanic electrodes. Eleven of the 23 subjects reported discomfort with the insertion of the tympanic electrode even with the use of topical xylocaine, whereas no complaints of discomfort were reported with the use of the extratympanic electrode. Conclusions: Both electrodes were effective for EchoG evaluation, but the extratympanic one was easier to insert and did not cause discomfort. However, the tympanic electrode produced tracings of greater amplitude and of better reproducibility. Laryngoscope, 119:563-566, 2009