118 resultados para Objective measurement
Resumo:
Background It is noteworthy that there is a clear clinical, epidemiological and pathophysiological association between upper and lower airway inflammation in rhinitis and asthma. Objective The aim of this study was to compare the eosinophil counts in induced sputum and nasal lavage fluids in asthma, checking their association and the accuracy of nasal eosinophilia as a predictor of sputum eosinophilia by a cross-sectional study. Methods The clinical evaluation, asthma control questionnaire (ACQ), pre- and post-bronchodilator spirometry, nasal and sputum sample was performed. The nasal eosinophilia was analysed by a receiver operating curve and logistic regression model. Results In 140 adults, the post-bronchodilator forced expiratory volume in 1 s (FEV(1)) did not differ between patients with or without sputum eosinophilia (0.18). After adjusted for upper airway symptoms, age, ACQ score and post-bronchodilator FEV(1), sputum eosinophilia was associated with 52 times increase in odds of nasal eosinophilia, whereas each 1% increase in bronchodilator response was associated with 7% increase in odds of nasal eosinophilia. Conclusion This study brings further evidence that upper airway diseases are an important component of the asthma syndrome. Furthermore, monitoring of nasal eosinophilia by quantitative cytology may be useful as a surrogate of sputum cytology in as a component of composite measurement for determining airway inflammation.
Resumo:
OBJECTIVE To evaluate the effect of the environment and the observer on the measurement of blood pressure (BP) as well as to compare home BP (HBP) and ambulatory BP (ABP) measurements in the diagnosis of white coat hypertension (WCH) and masked hypertension (MH) in children and adolescents with hypertension (HT). METHODS BP of 40 patients with HT (75% of which had secondary HT and were on antihypertensive medication), mean age 12.1 years was evaluated through casual measurements at the clinic and at the HT unit, HBP for 14 days with the OMRON HEM 705 CP monitor (Omron, Tokyo, Japan) and ABP performed with SPACELABS 90207 (Spacelabs, Redmond, WA), for 24 h. RESULTS HT was diagnosed at the doctor`s office by ABP and HBP in 30/40, 27/40, and 31/40 patients, respectively. Based on office BP and ABP, 60% of patients were normotensive, 17.5% HT, 7.5% had WCH, and 15% had MH, whereas based on office BP and HBP 65, 12.5, 10, and 12.5% of patients were classified according to these diagnoses, respectively. There was considerable diagnostic agreement of HT by ABP and HBP (McNemar test, P < 0.01) (kappa = 0.56). CONCLUSION In hypertensive children and adolescents, HBP and ABP present comparable results. HBP appears to be a useful diagnostic test for the detection of MH and WCH in pediatric patients.
Resumo:
The aim was to investigate inter-tester and intra-tester reliability and parallel reliability between a visual assessment method and a method using a pachymeter for locating the mid-point of the patella in determining the medial/lateral patella orientation. Fifteen asymptomatic subjects were assessed and the mid-point of the patella was determined by both methods on two separate occasions two weeks apart. Inter-tester reliability was obtained by ANOVA and by intraclass correlation coefficient (ICC); intra-tester reliability was obtained by a paired t-test and ICC; and parallel reliability was obtained by Pearson`s Correlation and ICC, for the measurement on the first and second evaluations. There was acceptable inter-tester agreement (p = 0.490) and reliability for the visual inspection (ICC = 0.747) and for the pachymeter (ICC = 0.716) at the second evaluation. The inter-tester reliability in the first evaluation was unacceptable (visual ICC = 0.604; pachymeter ICC = 0.612). Although there was statistical similarity between measurements for the first and second evaluations for all testers, intra-tester reliability was not acceptable for both methods: visual (examiner 1 ICC = 0.175; examiner 2 ICC = 0.189; examiner 3 ICC = 0.155) and pachymeter (examiner 1 ICC = 0.214; examiner 2 ICC = 0.246; examiner 3 ICC = 0.069). Parallel reliability gave a perfect correlation at the first evaluation (r=0.828; p<0.001) and at the second (r=0.756; p<0.001) and reliability was between acceptable and very good (ICC = [0.748-0.813]). Both visual and pachymeter methods provide reliable and similar medial/lateral patella orientation and are reliable between different examiners, but the results between the two assessments at 2 weeks` interval demonstrated an unacceptable reliability. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
The dorsolateral prefrontal cortex (DLPFC) has been implicated in the pathophysiology of mental disorders. Previous region-of-interest MRI studies that attempted to delineate this region adopted various landmarks and measurement techniques, with inconsistent results. We developed a new region-of-interest measurement method to obtain morphometric data of this region from structural MRI scans, taking into account knowledge from cytoarchitectonic postmortem studies and the large inter-individual variability of this region. MRI scans of 10 subjects were obtained, and DLPFC tracing was performed in the coronal plane by two independent raters using the semi-automated software Brains2. The intra-class correlation coefficients between two independent raters were 0.94 for the left DLPFC and 0.93 for the right DLPFC. The mean +/- S.D. DLPFC volumes were 9.23 +/- 2.35 ml for the left hemisphere and 8.20 +/- 2.08 ml for the right hemisphere. Our proposed method has high inter-rater reliability and is easy to implement, permitting the standardized measurement of this region for clinical research applications. (C) 2009 Elsevier Ireland Ltd. All rights reserved.
Resumo:
Background and objective The influence of ventilatory settings on static and functional haemodynamic parameters during mechanical ventilation is not completely known. The purpose of this study was to evaluate the effect of positive end-expiratory pressure, tidal volume and inspiratory to expiratory time ratio variations on haemodynamic parameters during haemorrhage and after transfusion of shed blood. Methods Ten anaesthetized pigs were instrumented and mechanically ventilated with a tidal volume of 8 ml kg(-1), a positive end-expiratory pressure of 5 cmH(2)O and an inspiratory to expiratory ratio of 1 : 2. Then, they were submitted in a random order to different ventilatory settings (tidal volume 16 ml kg(-1), positive end-expiratory pressure 15 cmH(2)O or inspiratory to expiratory time ratio 2: 1). Functional and static haemodynamic parameters (central venous pressure, pulmonary artery occlusion pressure, right ventricular end-diastolic volume and pulse pressure variation) were evaluated at baseline, during hypovolaemia (withdrawal of 20% of estimated blood volume) and after an infusion of withdrawn blood (posttransfusion). Results During baseline, a positive end-expiratory pressure of 15cmH(2)O significantly increased pulmonary artery occlusion pressure from 14.6 +/- 1.6 mmHg to 17.4 +/- 1.7 mmHg (P<0.001) and pulse pressure variation from 15.8 +/- 8.5% to 25.3 +/- 9.5% (P<0.001). High tidal volume increased pulse pressure variation from 15.8 8.5% to 31.6 +/- 10.4% (P<0.001), and an inspiratory to expiratory time ratio of 2: 1 significantly increased only central venous pressure. During hypovolaemia, high positive end-expiratory pressure influenced all studied variables, and high tidal volume strongly increased pulse pressure variation (40.5 +/- 12.4% pre vs. 84.2 +/- 19.1 % post, P<0.001). The inversion of the inspiratory to expiratory time ratio only slightly increased filling pressures during hypovolaemia, without without affecting pulse pressure variation or right ventricle end-diastolic volume. Conclusion We concluded that pulse pressure variation measurement is influenced by cyclic variations in intrathoracic pressure, such as those caused by augmentations in tidal volume. The increase in mean airway pressure caused by positive end-expiratory pressure affects cardiac filling pressures and also pulse pressure variation, although to a lesser extent. Inversion of the inspiratory to expiratory time ratio does not induce significant changes in static and functional haemodynamic parameters. Eur J Anaesthesiol 26:66-72 (c) 2009 European Society of Anaesthesiology.
Resumo:
Homeopathy has been used for more than two hundred years to treat chronic disease using various approaches in a wide range of diseases. However, for acute disease and critical illness, application has been limited by inadequate training of homeopathic physicians and the small number of pertinent clinical studies. In view of the difficulty of practising homeopathy in Intensive Care Units (ICU), a protocol was developed to facilitate description of objective homeopathic symptoms with a ranking of symptoms appropriate for these situations (Protocol for Objective Homeopathic Semiology). Examples of favorable results with individualized homeopathic treatments for a series of cases of Systemic Inflammatory Response Syndrome (sepsis) are described. Homeopathy (2008) 97, 206-213.
Resumo:
Objective: The aim of the study was to evaluate clinical and laboratorial features of 1234 patients with different etiologies of hyper-prolactinemia, as well as the response of 388 patients with prolactinomas to dopamine agonists. Design, setting, and patients: A total of 1234 hyperprolactinemic patients from 10 Brazilian endocrine centers were enrolled in this retrospective study. Main outcome measure: PRL measurement, thyroid function tests, and screening for macroprolactin were conducted. Results: Patients were subdivided as follows: 56.2% had prolactinomas, 14.5% drug-induced hyperprolactinemia, 9.3% macroprolactinemia, 6.6% non-functioning pituitary adenomas, 6.3% primary hypothyroidism, 3.6% idiopathic hyperprolactinemia, and 3.2% acromegaly. Clinical manifestations were similar irrespective of the etiology of the hyperprolactinemia. The highest PRL levels were observed in patients with prolactinomas but there was a great overlap in PRL values between all groups. However, PRL>500 ng/ml allowed a clear distinction between prolactinomas and the other etiologies. Cabergoline (CAB) was more effective than bromocriptine (BCR) in normalizing PRL levels (81.9% vs 67.1%, p<0.0001) and in inducing significant tumor shrinkage and complete disappearance of tumor mass. Drug resistance was observed in 10% of patients treated with CAB and in 18.4% of those that used BCR (p=0.0006). Side-effects and intolerance were also more common in BCR-treated patients. Conclusion: Prolactinomas, drug-induced hyperprolactinemia, and macroprolactinemia were the 3 most common causes of hyperprolactinemia. Although PRL levels could not reliably define the etiology of hyperprolactinemia, PRL values >500 ng/ml were exclusively seen in patients with prolactinomas. CAB was significantly more effective than BCR in terms of prolactin normalization, tumor shrinkage, and tolerability.
Resumo:
Background: The Flutter (R) VRP1 combines high frequency oscillation and positive expiratory pressure (PEP). Objective: To separately evaluate the effect of the Flutter (R) VRP1 components (high frequency oscillation and PEP) on mucus transportability in patients with bronchiectasis. Methods: Eighteen patients with bronchiectasis received sessions with the Flutter (R) VRP1 or PEP for 30 min daily in a randomized, crossover study. The treatment duration was four weeks with one of the therapies, one week of a ""wash-out"" period and followed by four more weeks with the other treatment. Weekly secretion samples were collected and evaluated for mucociliary relative transport velocity (RTV), displacement in a simulated cough machine (SCM) and contact angle measurement (CAM). For the proposed comparisons, a linear regression model was used with mixed effects with a significance level of 5%. Results: The Flutter (R) VRP1 treatment resulted in greater displacement in SCM and lower CAM when comparing results from the first (9.6 +/- 3.4 cm and 29.4 +/- 5.7 degrees, respectively) and fourth weeks of treatment (12.44 +/- 10.5 cm and 23.28 +/- 6.2, respectively; p < 0.05). There was no significant difference in the RTV between the treatment weeks for either the Flutter (R) VRP1 or PEP. Conclusion: The use of the Flutter (R) VRP1 for four weeks is capable of altering the respiratory secretion transport properties, and this alteration is related to the high frequency oscillation component. (C) 2011 Elsevier Ltd. All rights reserved.
Resumo:
Background: Several studies have shown that liquid and food intake interfere with the evaluation of body composition in adults. However, since there are no reports about this interference in the elderly population, the need to fast for this evaluation may be dispensable. Objectives: The objective of the present study was to assess the influence of liquid and solid food on the measurement of body composition by bioelectrical impedance analysis (BIA) and by dual energy X-ray absorptiometry (DXA). Design: Forty-one male volunteers aged 62 to 87 years participated in the study. The subjects were submitted to evaluation of body composition by DXA and BIA under fasting conditions and 1 hour after the ingestion of breakfast (500 ml of orange juice and one 50 g bread roll with butter). Results: There was no significant difference in the variables fat-free mass (FFM) or fat mass (FM) between the fasting condition and the evaluation performed 1 hour after the meal as measured by BIA or DXA. There was also no significant difference when the same variables were compared between methods. Conclusion: In the present study, the ingestion of 500 ml orange juice and of one bread roll with butter by elderly subjects did not affect the results of the parameters of body composition determined by BIA or DXA. Thus, these exams could be performed without the rigor of fasting, often poorly tolerated by the elderly.
Resumo:
Objective. To determine the blood recirculation ratio in the vascular access of patients on hemodialysis, and to calculate the Kt/Vs obtained with the different techniques of arteriovenous fistula punctures. Materials and Methods. A total of 174 patients were divided according to the technique used for arteriovenous fistula puncture: group 1, needles in opposite directions and with a distance of 5 cm or more between them; group 2, needles in opposite directions but with a distance of less than 5 cm; group 3, unidirectional needles with both directed to the heart and with a distance of 5 cm or more; group 4, unidirectional needles but separated by a distance of less than 5 cm between needles; and group 5, patients carrying a temporary venous catheter. Blood samples were collected for urea analysis, pre and post-dialysis for Kt/V rate, and other samples for calculation of the access recirculation. Results. Group 1 presented the lowest rate of access recirculation (8.51 +/- 4.90%) and the best Kt/V (1.71 +/- 0.36), while group 4 presented the worst access recirculation (20.68 +/- 4.92%) and Kt/V (1.16 +/- 0.26). All groups differed significantly from group 4 (p < 0.05), except group 5 with regard for Kt/V parameter. Discussion. The technique of arteriovenous fistula puncture is an essential factor to decrease the access recirculation and assure better results of measurement of hemodialysis adequacy. On the basis of the results obtained, insertion of the needles in the same direction and with a distance of less than 5 cm between them should be avoided.
Resumo:
Background The mechanism underlying increased perception of food bolus passage in the absence of esophageal mechanical obstruction has not been completely elucidated. A correlation between the intensity of the symptom and the severity of esophageal dysfunction, either motility (manometry) or bolus transit (impedance) has not been clearly demonstrated. The aim of this study was to analyze the correlation between objective esophageal function assessment (with manometry and impedance) and perception of bolus passage in healthy volunteers (HV) with normal and pharmacologically-induced esophageal hypocontractility, and in patients with gastro-esophageal reflux disease (GERD) with and without ineffective esophageal motility (IEM). Methods Combined manometry-impedance was performed in 10 HV, 19 GERD patients without IEM and nine patients with IEM. Additionally, nine HV were studied after 50 mg sildenafil, which induced esophageal peristaltic failure. Perception of each 5 mL viscous swallow was evaluated using a 5-point scale. Manometry identified hypocontractility (contractions lower than 30 mmHg) and impedance identified incomplete bolus clearance. Key Results In HV and in GERD patients with and without IEM, there was no association between either manometry or impedance and perception on per swallow analysis (OR: 0.842 and OR: 2.017, respectively), as well as on per subject analysis (P = 0.44 and P = 0.16, respectively). Lack of correlation was also found in HV with esophageal hypocontractility induced by sildenafil. Conclusions & Inferences There is no agreement between objective measurements of esophageal function and subjective perception of bolus passage. These results suggest that increased bolus passage perception in patients without mechanical obstruction might be due to esophageal hypersensitivity.
Resumo:
Objective: To evaluate the percutaneous Achilles tendon sectioning technique using a large gauge needle for the correction of residual equinus of congenital clubfoot treated with the Ponseti method. Methods: Fifty-seven Achilles tendon sections were prospectively evaluated in thirty-nine patients with clubfoot, treated with the Ponseti method between July 2005 and December 2008. The tenotomy was performed percutaneously with a large gauge needle. Ultrasound scan was performed immediately after the section, to ascertain whether the tenotomy was complete, as well as stump separation. Results: There was complete tendon section in all cases, but the need to perform the section maneuver more than once was common, due to the persistence of the residual strands between tendon stumps. The Thompson test and dynamic ultrasound evaluation were able to detect incomplete tenotomies. The mean ultrasound measurement of the tendon gap was 5.70 +/- 2.23 mm. Two patients had abnormal bleeding, which was controlled by digital pressure and did not compromise foot perfusion. Conclusion: Percutaneous Achilles tendon sectioning with a needle proved to be efficient and safe to correct residual equinus of clubfoot treated with the Ponseti technique.
Resumo:
Objective: To assess the level of lipid peroxidation (LP) and vitamin E in the follicular fluid and serum of infertile patients, with or without endometriosis. who were submitted to ovulation induction for assisted reproduction procedures. Design: Prospective study. Setting: Assisted conception unit, university hospital. Patient(s): Infertile patients 20 to 38 years of age were selected prospectively and consecutively and were divided into the endometriosis group (17 patients with pelvic endometriosis) and the control group (19 patients with previous tubal ligation or male factor and without endometriosis). Intervention(s): Peripheral blood samples were collected on D1 (before the beginning of the use of gonadotropins), D2 (day of hCG administration), and D3 (day of oocyte retrieval). On D3, follicular-fluid samples free from blood contamination also were collected and stored. Main Outcome Measure(S): Lipid peroxidation was assessed by malondialdehyde quantification by spectrophotometry, and measurement of vitamin E was performed by HLPC. Result(s): On D1, no significant difference in LP was observed between groups. However, vitamin E levels were significantly higher in the control group. On D2, LP levels were significantly higher in the endometriosis group compared with in the control group, and vitamin E levels continued to be significantly higher in the control group. On D3, there was no significant difference in serum and follicular-fluid levels of LP and vitamin E between groups. However, on D3, vitamin E levels were found to be significantly higher in serum than in follicular fluid in both groups, whereas malondialdchyde levels were significantly lower in follicular fluid than in serum only in the control group. Conclusion(s): Before the beginning of ovulation induction, a significant decrease in vitamin E was observed in patients with endometriosis, perhaps because antioxidants are consumed during oxidation reactions. After ovulation induction with exogenous gonadotropins, the group of patients with endometriosis not only presented increased lipid peroxidation but also maintained lower vitamin E levels than the control group, a fact that hypothetically could compromise oocyte quality in endometriotic patients. However, on the day of oocyte retrieval, both serum LP potential and vitamin E levels were found to be similar in the two groups. (Fertil Steril(R) 2008; 90:2080-5. (C) 2008 by American Society for Reproductive Medicine.)
Resumo:
Objective. Endothelial impairment evaluation by sonographic measurement of flow-mediated dilatation (FMD) has become broadly used. However, this method has 2 main caveats: the dilatation depends on the baseline arterial diameter, and a high precision level is required. Vasodilatation leads to an amplified fall in impedance. We hypothesized that assessment of the pulsatility index change (PI-C) 1 minute after 5-minute forearm compression might evaluate that fall in impedance. The aim of this study was to compare the PI-C with FMD. Methods. Flow-mediated dilatation and the PI-C were assessed in 51 healthy women aged between 35.1 and 67.1 years. We correlated both FMD and the PI-C with age, body mass index, waist circumference, cholesterol level, high-density lipoprotein level, glucose level, systolic and diastolic blood pressure, pulse pressure, brachial artery diameter, simplified Framingham score, intima-media thickness, and carotid stiffness index. Intraclass correlation coefficients between 2 FMD and PI-C measurements were also examined. Results. Only FMD correlated with baseline brachial diameter (r=-0.53). The PI-C had a high correlation with age, body mass index, waist circumference, cholesterol level, systolic blood pressure, pulse pressure, simplified Framingham score, and intima-media thickness. The correlation between FMD and the PI-C was high (r=-0.66). The PI-C had a higher intraclass correlation coefficient (0.991) than FMD (0.836) but not brachial artery diameter (0.989). Conclusions. The PI-C had a large correlation with various markers of cardiovascular risk. Additionally, PI-C measurement does not require offline analysis, extra software, or electrocardiography We think that the PI-C could be considered a marker of endothelial function. However, more studies are required before further conclusions.
Resumo:
Objectives The methods currently available for the measurement of energy expenditure in patients, such as indirect calorimetry and double-labelled water, are expensive and are limited in Brazil to research projects. Thus, equations for the prediction of resting metabolic rate appear to be a viable alternative for clinical practice. However, there are no specific equations for the Brazilian population and few studies have been conducted on Brazilian women in the climacteric period using existing and commonly applied equations. On this basis, the objective of the present study was to investigate the concordance between the predictive equations most frequently used and indirect calorimetry for the measurement of resting metabolic rate. Methods We calculated the St. Laurent concordance correlation coefficient between the equations and resting metabolic rate calculated by indirect calorimetry in 46 climacteric women. Results The equation showing the best concordance was that of the FAO/WHO/UNU formula (0.63), which proved to be better than the Harris & Benedict equation (0.55) for the sample studied. Conclusions On the basis of the results of the present study, we conclude that the FAO/WHO/UNU formula can be used to predict better the resting metabolic rate of climacteric women. Further studies using more homogeneous and larger samples are needed to permit the use of the FAO/WHO/UNU formula for this population group with greater accuracy.