235 resultados para Laser cutting


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents the results obtained with the production of briquettes from the steel grit found in the residue of ornamental rocks. The grit recovered by magnetic separation was characterized by titrimetric analysis, EDS (Electron Dispersive Spectroscopy) and X-ray diffraction for the analysis of iron concentration in the residue. The size and distribution of particles were obtained by the granulometric analysis method and scanning electron microscopy (SEM). The process resulted in a concentrate containing 93% metallic iron. The maximum load before fracture of the green briquettes was 1.02kN and of the dry briquettes was 3.59kN.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The application of airborne laser scanning (ALS) technologies in forest inventories has shown great potential to improve the efficiency of forest planning activities. Precise estimates, fast assessment and relatively low complexity can explain the good results in terms of efficiency. The evolution of GPS and inertial measurement technologies, as well as the observed lower assessment costs when these technologies are applied to large scale studies, can explain the increasing dissemination of ALS technologies. The observed good quality of results can be expressed by estimates of volumes and basal area with estimated error below the level of 8.4%, depending on the size of sampled area, the quantity of laser pulses per square meter and the number of control plots. This paper analyzes the potential of an ALS assessment to produce certain forest inventory statistics in plantations of cloned Eucalyptus spp with precision equal of superior to conventional methods. The statistics of interest in this case were: volume, basal area, mean height and dominant trees mean height. The ALS flight for data assessment covered two strips of approximately 2 by 20 Km, in which clouds of points were sampled in circular plots with a radius of 13 m. Plots were sampled in different parts of the strips to cover different stand ages. The clouds of points generated by the ALS assessment: overall height mean, standard error, five percentiles (height under which we can find 10%, 30%, 50%,70% and 90% of the ALS points above ground level in the cloud), and density of points above ground level in each percentile were calculated. The ALS statistics were used in regression models to estimate mean diameter, mean height, mean height of dominant trees, basal area and volume. Conventional forest inventory sample plots provided real data. For volume, an exploratory assessment involving different combinations of ALS statistics allowed for the definition of the most promising relationships and fitting tests based on well known forest biometric models. The models based on ALS statistics that produced the best results involved: the 30% percentile to estimate mean diameter (R(2)=0,88 and MQE%=0,0004); the 10% and 90% percentiles to estimate mean height (R(2)=0,94 and MQE%=0,0003); the 90% percentile to estimate dominant height (R(2)=0,96 and MQE%=0,0003); the 10% percentile and mean height of ALS points to estimate basal area (R(2)=0,92 and MQE%=0,0016); and, to estimate volume, age and the 30% and 90% percentiles (R(2)=0,95 MQE%=0,002). Among the tested forest biometric models, the best fits were provided by the modified Schumacher using age and the 90% percentile, modified Clutter using age, mean height of ALS points and the 70% percentile, and modified Buckman using age, mean height of ALS points and the 10% percentile.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

When a coherent light beam is scattered from a colloidal medium, in the observation plane, appears a random grainy image known as speckle pattern. The time evolution of this interference image carries information about the ensemble-averaged dynamics of the scatterer particles. The aim of this work was to evaluate the use of dynamic speckles as an alternative tool to monitoring frozen foams formulated with glucose and fructose syrups. Ice creams, after preparation and packing, were stored at 18 degrees C. Changes in properties of products were analyzed by speckle phenomena at three room temperatures (20 degrees C, 25 degrees C and 30 degrees C), minute by minute, during 50 min. Two moments were identified in which samples activity achieved significant levels. These instants were associated, respectively, to ice crystals melting and to air bubbles dissipation into the food matrix causing motion of diverse structures. As expected, ice crystals melting was first in formulations containing fructose syrup, but for same samples, air losses were delayed. Speckle methodology was satisfactory to observe temporal evolution of transient process, opening goods prospects to application, still incoming, in foodstuffs researches. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The quenching of the triplet state of three n-alkyl 3-nitrophenyl ethers: 3-nitroanisol (3-NA), n-butyl 3-nitrophenyl ether (3-NB) and n-decyl 3-nitrophenyl ether (3-ND) by four aniline derivatives: aniline (AN), N,N-dimethylaniline (DMA), 2,4,6-trimethylaniline (TMA), and 4-tetradecylaniline (TDA), was investigated in aqueous micellar SDS solutions by laser flash photolysis. The transient absorption spectra for 3-NA and 3-NB reveal the formation of long-lived intermediate species in the presence of all four quenchers. while for 3-ND no amine-induced intermediates are observed. Comparison of the transient absorption spectra of the probe 3-NA in the presence of DMA in aqueous and micellar solutions shows that the intermediate species are favored by the SDS micelles. With DMA and TMA as quenchers the intermediates are suggested to be the ion radicals generated by single electron transfer from the amine to the probe in the triplet excited state. For the quenchers AN and TDA, the intermediates may be a-complexes. The relative quenching efficiencies generally decrease as the affinity of the quencher for the micellar phase (AN < DMA < TMA < TDA) increases and the mobility of the excited probe (3-NA > 2-NB) decreases. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to compare the effects of Low-intensity Laser Therapy (LILT) and Light Emitting Diode Therapy (LEDT) of low intensity on the treatment of lesioned Achilles tendon of rats. The experimental model consisted of a partial mechanical lesion on the right Achilles tendon deep portion of 90 rats. One hour after the lesion, the injured animals received applications of laser/LED (685, 830/630, 880 nm), and the same procedure was repeated at 24-h intervals, for 10 days. The healing process and deposition of collagen were evaluated based on a polarization microscopy analysis of the alignment and organization of collagen bundles, through the birefringence (optical retardation-OR). The results showed a real efficiency of treatments based on LEDT and confirmed that LILT seems to be effective on healing process. Although absence of coherence of LED light, tendon healing treatment with this feature was satisfactory and can certainly replace treatments based on laser light applications. Applications of infrared laser at 830 nm and LED 880 nm were more efficient when the aim is a good organization, aggregation, and alignment of the collagen bundles on tendon healing. However, more research is needed for a safety and more efficient determination of a protocol with LED.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purposes of this study were to evaluate in vitro the influence of different frequencies of Er:YAG laser on the human dentin caries removal capacity. Thirty fragments obtained from third molars were randomly assigned into three groups (n = 10) according to the laser frequency used: 4, 6, and 10 Hz. The caries lesion (+/-1 mm deep) was induced before the irradiation by S. mutans cultures for 6 weeks. The specimens of all groups were irradiated with 200 mJ of energy in noncontact and focused mode under constant refrigeration (water flow: 2.5 mL/min). Quantitative analysis of the caries removal was performed by DIAGNOdent (TM) and the Axion Vision (TM) software. Qualitative analysis was performed by Scanning electron microscope (SEM) and light microscope (LM). Data were analyzed by ANOVA and Fishers` tests. The DIAGNOdent (TM) revealed that the caries removal was similar with 4 and 6 Hz and was superior with 10 Hz (P < 0.05). The analysis with Axion Vision (TM) software revealed that the caries removal was similar with 6 and 10 Hz and the 4 Hz group promoted the lowest caries removal. Through SEM morphologic analysis, some specimens irradiated with 4 Hz presented, under the demineralized dentin, a disorganized collagenous matrix. The LM images revealed that all frequencies used promoted irregular caries removal, being observed over preparations with 6 and 10 Hz. It can be concluded that the increase of Er:YAG laser frequency provided a higher dentin caries removal without selectivity to the disorganized dentin. Microsc. Res. Tech. 74:281-286, 2011. (C) 2010 Wiley-Liss, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this in vitro study was to verify through micro tensile bond test the bond strength of an adhesive system irradiated with Nd:YAG laser in dentine previously treated with Er:YAG laser. Twenty caries free extracted human third molars were used. The teeth were divided in four experimental groups (n = 5): (G1) control group; (G2) irradiation of the adhesive system with the Nd:YAG laser; (G3) dentin treatment with Er:YAG laser; (G4) dentin treatment with Er:YAG laser followed by the irradiation of the adhesive system with Nd:YAG laser. The Er:YAG laser fluency parameter for the dentin treatment was of 60 J/cm(2). ne adhesive system was irradiated with the Nd:YAG laser with fluency of 100 J/cm(2). Dental restorations were performed with Adper Single Bond 2/Z250. One tooth from each group was prepared for the evaluation of the adhesive interface under SEM and bond failure tests were also performed and evaluated. The statistical analysis showed statistical significant difference between the groups G1 and G3, G1 and G4, G2 and G3, and G2 and G4; and similarity between the groups G1 and G2, and G3 and G4. The adhesive failures were predominant in all the experimental groups. The SEM analysis showed an adhesive interface with features confirming the results of the mechanical tests. The Nd:YAG laser on the adhesive system did not influence the bond strength in dentin treated or not with the Er:YAG laser.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study investigated the organic and inorganic constituents of healthy leaves and Candidatus Liberibacter asiaticus (CLas)-inoculated leaves of citrus plants. The bacteria CLas are one of the causal agents of citrus greening (or Huanglongbing) and its effect on citrus leaves was investigated using laser-induced breakdown spectroscopy (LIBS) combined with chemometrics. The information obtained from the LIBS spectra profiles with chemometrics analysis was promising for the construction of predictive models to identify healthy and infected plants. The major, macro- and microconstituents were relevant for differentiation of the sample conditions. The models were then applied to different inoculation times (from 1 to 8 months). The models were effective in the classification of 82-97% of the diseased samples with a 95% significance level. The novelty of this method was in the fingerprinting of healthy and diseased plants based on their organic and inorganic contents. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study reports on the development and characterization of bovine serum albumin (BSA) nanospheres containing Silicon(IV) phthalocyanine (NzPc) and/or maghemite nanoparticles (MNP), the latter introduced via ionic magnetic fluid (MF). The nanosized BSA-loaded samples were designed for synergic application while combining Photodynamic Therapy and Hyperthermia. Incorporation of MNP in the albumin-based template, allowing full control of the magnetic content, was accomplished by adding a highly-stable ionic magnetic fluid sample to the albumin suspension, following heat denaturing. The material`s evaluation was performed using Zeta potential measurements and scanning electron microscopy. The samples were characterized by steady-state techniques and time-resolved fluorescence. The in vitro assay, using human fibroblasts, revealed no cytotoxic effect in all samples investigated, demonstrating the potential of the tested system as a synergistic drug delivery system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To compare changes in corneal hysteresis (CH) and the corneal resistance factor (CRF) in myopic and hyperopic laser in situ keratomileusis (LASIK) and evaluate their relationship to the number of photoablative pulses delivered, a surrogate for ablation volume. SETTING: Cleveland Clinic Cole Eye Institute, Cleveland, Ohio, USA. METHODS: Preoperative and 1-week postoperative Ocular Response Analyzer measurements in eyes that had femtosecond-assisted LASIK were studied retrospectively. Changes in CH and CRF were compared and tested for correlation with the number of excimer laser pulses. RESULTS: Thirteen myopic eyes and 11 hyperopic eyes were evaluated. Preoperative corneal thickness, CH, CRF, programmed correction magnitude, flap thickness, and total number of fixed spotsize photoablative pulses were similar in the 2 groups (P>.1). Decreases in CH and CRF were greater after myopic LASIK than after hyperopic LASIK (P<.005), and changes in CRF were correlated with the number of excimer laser pulses in the myopic group only (r = -0.63, P = .02). Regardless of ablation profile, changes in CH were more strongly correlated with preoperative CH values than with attempted ablation volume. CONCLUSIONS: With comparable flap thickness and attempted ablation volumes, myopic photoablation profiles were associated with greater decreases in CRF and CH than hyperopic profiles. Results indicate that preoperative corneal biomechanical status, ablation volume, and the spatial distribution of ablation are important factors that affect corneal resistance and viscous dissipative properties differently. Preferential tissue removal in the natively thicker paracentral cornea in hyperopia may partially account for the rarity of ectasia after hyperopic LASIK.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background/Aims: The use of low-level laser therapy (LLLT) in neurosurgery is still hardly disseminated and there are situations in which the effects of this therapeutic tool would be extremely relevant in this medical field. The aim of the present study is to analyze the effect of LLLT on tissue repair after the corrective surgical incision in neonates with myelomeningocele, in an attempt to diminish the incidence of postoperative dehiscences following surgical repair performed immediately after birth. Materials and Methods: Prospective pilot study with 13 patients submitted to surgery at birth who received adjuvant treatment with LLLT (group A). A diode laser CW, lambda = 685 nm, p = 21 mW, was applied punctually along the surgical incision, with 0.19 J delivered per point, accounting for a total of 4-10 J delivered energy per patient, according to the surgical wound area and then compared with the results obtained in 23 patients who underwent surgery without laser therapy (group B). Results: This pilot study disclosed a significant decline in dehiscences of the surgical wounds in neonates who were submitted to LLLT (7.69 vs. 17.39%). Conclusion: This new adjuvant therapeutic modality with LLLT aided the healing of surgical wounds, preventing morbidities, as well as shortening the period of hospital stay, which implies a reduction of costs for patients and for the institution. Copyright (C) 2010 S. Karger AG, Basel

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate laser combined with intravitreal triamcinolone acetonide (IVTA) for the management of patients with proliferative diabetic retinopathy (PDR) and clinically significant macular edema (CSME). DESIGN: Randomized clinical trial. METHODS: SETTINGS: Single center. STUDY POPULATION: Twenty-two patients with bilateral treatment,naive moderate PDR and CSME. INTERVENTION: Laser (panretinal and macular) photocoagulation was performed in each eye, followed by IVTA in one randomly assigned eye. Best,corrected visual acuity (BCVA), fundus photography, and optical coherence tomography were performed at baseline and at months 1, 3, 6, 9, and 12. MAIN OUTCOME MEASURES:. Changes in BCVA, central macular thickness (CMT), and total macular volume (TMV). RESULTS: The mean logarithm of the minimal angle of resolution (logMAR) BCVA improved significantly, and mean CMT and TMV were significantly reduced in the IVTA group compared with the laser,only group (controls) at all study follow-up visits (P < .001). The mean logMAR BCVA (Snellen equivalent) was 0.44 (20/50(-2)) for the IVTA group and 0.38 (20/50(+1)) for the controls at baseline, and 0.12 (20/25(-1)) for the IVTA group and 0.32 (20/40(-1)) for the controls at 12 months (P < .001.). The mean CMT and TMV were, respectively, 360 mu m and 8.59 mm(3) for the IVTA group and 331 mu m and 8.44 mm(3) for the controls at baseline, and 236 mu m and 7.32 mm(3) for the IVTA group and 266 mu m and 7.78 mm(3) for the controls at 12 months (P < .001). CONCLUSIONS: The combination of laser photocoagulation with IVTA was associated with improved BCVA and decreased CMT and TMV when compared with laser photocoagulation alone for the treatment of moderate PDR with CSME. (Am J Ophthalmol 2009;147:291-297. (C) 2009 by Elsevier Inc. All rights reserved.)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims: There remains significant concern about the long-term safety of drug-eluting stents (DES). However, bare metal stents (BMS) have been used safely for over two decades. There is therefore a pressing need to explore alternative strategies for reducing restenosis with BMS. This study was designed to examine whether IVUS-guided cutting balloon angioplasty (CBA) with BMS could convey similar restenosis rates to DES. Methods and results: In the randomised REstenosis reDUction by Cutting balloon angioplasty Evaluation (REDUCE III) study, 521 patients were divided into four groups based on device and IVUS use before BMS (IVUS-CBA-BMS: 137 patients; Angio-CBA-BMS: 123; IVUS-BA-BMS: 142; and Angio-BA-BMS: 119). At follow-up, the IVUS-CBA-BMS group had a significantly lower restenosis rate (6.6%) than the other groups (p=0.016). We performed a quantitative coronary angiography (QCA) based matched comparison between an IVUS-guided CBA-BMS strategy (REDUCE III) and a DES strategy (Rapamycin-Eluting-Stent Evaluation At Rotterdam Cardiology. Hospital, the RESEARCH study). We matched the presence of diabetes, vessel size, and lesion severity by QCA. Restenosis (>50% diameter stenosis at follow-up) and target vessel revascularisation (TVR) were examined. QCA-matched comparison resulted in 120-paired lesions. While acute gain was significantly greater in IVUS-CBA-BMS than DES (1.65 +/- 0.41 mm vs. 1.28 +/- 0.57 mm, p=0.001), late loss was significantly less with DES than with IVUS-CBA-BMS (0.03 +/- 0.42 mm vs. 0.80 +/- 0.47 mm, p=0.001). However, no difference was found in restenosis rates (IVUS-CBA-BMS: 6.6% vs. DES: 5.0%, p=0.582) and TVR (6.6% and 6.6%, respectively). Conclusions: An IVUS-guided CBA-BMS strategy yielded restenosis rates similar to those achieved by DES and provided an effective alternative to the use of DES.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Brain injury is responsible for significant morbidity and mortality in trauma patients, but controversy still exists over therapeutic management for these patients. The objective of this study was to analyze the effect of phototherapy with low intensity lasers on local and systemic immunomodulation following cryogenic brain injury. Laser phototherapy was applied (or not-controls) immediately after cryogenic brain injury performed in 51 adult male Wistar rats. The animals were irradiated twice (3 h interval), with continuous diode laser (gallium-aluminum-arsenide (GaAlAs), 780 nm, or indium-gallium-aluminum-phosphide (InGaAlP), 660 nm) in two points and contact mode, 40 mW, spot size 0.042 cm(2), 3 J/cm(2) and 5 J/cm(2) (3 s and 5 s, respectively). The experimental groups were: Control (non-irradiated), RL3 (visible red laser/ 3 J/cm(2)), RL5 (visible red laser/5 J/cm(2)), IRL3 (infrared laser/ 3 J/cm(2)), IRL5 (infrared laser/5 J/cm(2)). The production of interleukin-1IL-1 beta (IL-1 beta), interleukin6 (IL-6), interleukin-10 (IL-10), and tumor necrosis factor-alpha (TNF-alpha) was analyzed by enzyme immunoassay technique (ELISA) test in brain and blood samples. The IL-1 beta concentration in brain of the control group ;was significantly reduced in 24 h (p < 0.01). This reduction was also observed in the RL5 and IRL3 groups. The TNF-alpha and IL-6 concentrations increased significantly (p < 0.01 and p < 0.05, respectively) in the blood of all groups, except by the IRL3 group. The IL-6 levels in RL3 group were significantly smaller than in control group in both experimental times. IL-10 concentration was maintained stable in all groups in brain and blood. Under the conditions of this study, it is possible to conclude that the laser phototherapy can affect TNF-alpha, IL-1 beta and IL-6 levels in the brain and in circulation in the first 24 h following cryogenic brain injury. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and Objectives: Chronic autoimmune thyroiditis (CAT) remains the most common cause of acquired hypothyroidism There is currently no therapy that is capable of regenerating CAT-damaged thyroid tissue The objective of this study was to gauge the value of applying low-level laser therapy (LLLT) in CAT patients based on both ultrasound studies (USs) and evaluations of thyroid function and thyroid autoantibodies. Study Design/Materials and Methods: Fifteen patients who had hypothyroidism caused by CAT and were undergoing levothyroxine (LT4) treatment were selected to participate in the study Patients received 10 applications of LLLT (830 nm, output power 50 mW) in continuous mode, twice a week, using either the punctual technique (8 patients) or the sweep technique (7 patients), with fluence in the range of 38-108 J/cm(2) USs were performed prior to and 30 days after LLLT USs included a quantitative analysis of echogenicity through a gray-scale computerized histogram index (El). Following the second ultrasound (30 days after LLLT), LT4 was discontinued in all patients and, if required, reintroduced Truodothyronine, thyroxine (T4), free T4, thyrotropin, thyroid peroxidase (TPOAb) and thyroglobulin (TgAb) antibodies levels were assessed before LLLT and then 1, 2, 3, 6, and 9 months after LT4 withdrawal. Results: We noted all patients` reduced LT4 dosage needs, including 7 (47%) who did not require any LT4 through the 9-month follow-up The LT4 dosage used pre-LLLT (96 +/- 22 mu g/day) decreased in the 9th month of follow-up (38 23 mu g/day; P<0.0001) TPOAb levels also decreased (pre-LLLT = 982 +/- 530 U/ml, post-LLLT = 579 454 U/ml, P = 0 016) TgAb levels were not reduced, though we did observe a post-LLLT increase in the EI (pre-LLLT = 0 99 +/- 0.09, post-LLLT= 1.21 +/- 0.19, P=0.001) Conclusion: The preliminary results indicate that LLLT promotes the improvement of thyroid function, as patients experienced a decreased need for LT4, a reduction in TPOAb levels, and an increase in parenchymal echogenicity Lasers Surg. Med. 42:589-596, 2010. (C) 2010 Wiley-Liss, Inc