100 resultados para Disintegration forces


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Orthodontic tooth movement is achieved by the remodeling of alveolar bone in response to mechanical loading, and is supposed to be mediated by several host mediators, such as chemokines. In this study we investigated the pattern of mRNAs expression encoding for osteoblast and osteoclast related chemokines, and further correlated them with the profile of bone remodeling markers in palatal and buccal sides of tooth under orthodontic force, where tensile (T) and compressive (C) forces, respectively, predominate. Real-time PCR was performed with periodontal ligament mRNA from samples of T and C sides of human teeth submitted to rapid maxillary expansion, while periodontal ligament of normal teeth were used as controls. Results showed that both T and C sides exhibited significant higher expression of all targets when compared to controls. Comparing C and T sides, C side exhibited higher expression of MCP-1/CCL2, MIP-1 alpha/CCL3 and RANKL, while T side presented higher expression of OCN. The expression of RANTES/CCL5 and SDF-1/CXCL12 was similar in C and T sides. Our data demonstrate a differential expression of chemokines in compressed and stretched PDL during orthodontic tooth movement, suggesting that chemokines pattern may contribute to the differential bone remodeling in response to orthodontic force through the establishment of distinct microenvironments in compression and tension sides. (C) 2008 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study was to deter-mine maximum bite force in molar and incisor regions in young Brazilian indigenous individuals, who have had a natural diet since birth, and compare the sample with white Brazilian individuals. To do this, individuals were paired one-to-one (same weight, height, and Class I facial pattern). A secondary purpose was to elucidate the relation between bite force and gender in both populations. Eighty-two Brazilians took part in this study. Participants were aged between 18 and 28 years and were divided into two groups: 41 Xingu indigenous individuals and 41 white Brazilian individuals, with 28 men and 13 women in each group. The inclusion criteria were: having complete dentition; normal occlusion; no neurological, psychiatric or movement disorders.; no reports of toothaches; having satisfactory periodontal health; absence of large facial skeletal alterations (typical Class II and Class III individuals); and no previous treatments using occlusal splints. To measure maximum bite force, a digital dynamometer model IDDK (Kratos-Equipamentos Industriais Ltda, Cotia, Sao Paulo, Brazil) was used, with a capacity of 1000 N, adapted for oral conditions. Assessments were made in the first molar (right and left) and central incisive regions. Results reveal that mean maximum bite forces in indigenous individuals of the right molar is 421 N, left molar 429 N and incisor region is 194 14 and for white individuals of the right molar is 410 N, left molar 422 N and incisor region is 117 N. Comparing indigenous with white individuals, maximal bite force showed a tendency of being greater in the indigenous group. It was observed that the incisor region showed statistical significance (p < 0.0005) but no significance was observed in the molar region. Moreover, indigenous men showed the highest bite force values. (C) 2007 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The current study describes the morphologic macular features in two eyes that developed full-thickness macular holes in the setting of documented vitreofoveal separation. Using third-generation optical coherence tomography, complete vitreofoveal separation associated with the disruption of the inner foveal retina was documented in both cases. Five months after presentation, decreased vision and epiretinal membrane formation associated with development of a full-thickness macular hole were observed in the first patient. In the second patient, a full-thickness macular hole was demonstrated by optical coherence tomography 6 weeks after presentation. These findings suggest that full-thickness macular holes may develop in eyes with vitreofoveal separation. Evidence of the disturbance of the inner foveal architecture on optical coherence tomography indicates the potential role of factors other than anteroposterior or oblique vitreoretinal tractional forces in the genesis of some full-thickness macular holes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Nowadays, the great saphenous vein is the vascular conduit that is most frequently employed in coronary and peripheral revascularization surgery. It is known that saphenous vein bypass grafts have shorter patency than arterial ones, partly because the wall of the normal saphenous vein has different structural and functional characteristics. The features of this vein can be affected by the large distention pressures it is submitted to during its preparation and insertion into the arterial system. Indeed, a vein graft is subjected to considerable changes in hemodynamic forces upon implantation into the arterial circulation, since it is transplanted from a non-pulsatile, low-pressure, low-flow environment with minimal shear stress to a high-pressure system with pulsatile flow, where it undergoes cyclic strain and elevated shear. These changes can be responsible for functional and morphological alterations in the vessel wall, culminating in intima hyperproliferation and atherosclerotic degeneration, which contribute to early graft thrombosis. This review has followed a predetermined strategy for updating information on the human saphenous vein (HSV). Besides presenting the aspects relative to the basic pharmacology, this text also includes surgical aspects concerning HSV harvesting, the possible effects of the major groups of cardiovascular drugs on the HSV, and finally the interference of major cardiovascular diseases in the vascular reactivity of the HSV.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this in vitro study was to compare the bond strength between fiber post and laser-treated root canals. Forty single-rooted bovine teeth were endodontically treated and randomly divided into four groups of equal size according to the root canal treatment: group 1 conventional treatment (without laser irradiation); group 2 Nd:YAG laser (1.5 W, 10 Hz, 100 mJ); group 3 Er,Cr:YSGG laser (0.75 W, 20 Hz); and group 4 Nd:YAG + Er,Cr:YSGG lasers. The fiber posts were cemented with an adhesive system + resin cement, in accordance with the manufacturer`s instructions. A mini acrylic pipe was fixed on the coronal section of the post using a light-polymerized resin. Specimens were mounted on an acrylic pipe with a self-polymerized resin. Retention forces were determined using a universal testing machine (0.5 mm/min). Data were analyzed using one-way ANOVA and Tukey tests (p < 0.05). The post retention force in group 2 was found to be lower than that in the other experimental groups. Fractures were observed at the interface between the dentin and the resin in all groups. High-intensity lasers can be used in conventional endodontic treatment; however, root canal surface irradiation using the Nd:YAG laser was shown to negatively affect the post retention force.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives. The objective of this study was to elucidate the changes occurring in the temporomandibular joint (TMJ) after surgical mandibular advancement with different fixation techniques: bicortical screws (rigid fixation) and miniplates (semi-rigid fixation). Study design. Eighteen minipigs were equally and randomly divided into 3 groups: Group I (control), nonoperated animals; Group II, animals submitted to surgical advancement surgery and osteosynthesis by bicortical screws; and Group III, animals submitted to surgical advancement surgery and osteosynthesis by miniplates. Four months after the surgeries, the presence of interleukin (IL)-6 and IL-10 in synovial fluid samples was assessed in ELISA experiments. TMJs were histologically prepared. Results. Higher levels of IL-10 (P = .0436) were found for Group II. Descriptive histological analysis was compatible with the ELISA findings. Conclusions. Rigid fixation evokes more pronounced signs of bone remodeling in the TMJ, whereas malleable fixation promotes a more intense inflammatory activity. Therefore, rigid fixation seems to transmit a higher impact of postoperative masticatory forces to the TMJ.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study evaluated the fracture resistance of endodontically treated teeth restored with prefabricated carbon fiber posts and varying quantities of coronal dentin. Sixty freshly extracted upper canines were randomly divided into groups of 10 teeth each. The specimens were exposed to 250,000 cycles in a controlled chewing simulator. All intact specimens were subjected to a static load (N) in a universal testing machine at 45 degrees to the long axis. Data were analyzed by 1-way analysis of variance and Tukey test (alpha = .05). Significant differences (P < .001) were found among the mean fracture forces of the test groups (positive control, 0 mm, 1 mm, 2 mm, 3 mm, and negative control groups: 1022.82 N, 1008.22 N, 1292.52 N, 1289.19 N, 1255.38 N, and 1582.11, respectively). These results suggested that the amount of coronal dentin did not significantly increase the fracture resistance of endodontically treated teeth restored with prefabricated carbon fiber post and composite resin core. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2008;106:e52-e57)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of this study was to evaluate the bone repair along a mandibular body osteotomy after using a 2.0 miniplate system. Nine adult mongrel dogs were subjected to unilateral continuous defect through an osteotomy between the mandibular 3rd and 4th premolars. Two four-hole miniplates were placed in accordance with the Arbeitgeimeinschaft fur Osteosynthesefragen Manual. Miniplates adapted to the alveolar processes were fixed monocortically with 6.0-mm-length titanium alloy self-tapping screws, whereas miniplates placed near the mandible bases were fixed bicortically. At 2, 6 and 12 weeks, three dogs were sacrificed per period, and the osteotomy sites were removed, divided into three thirds (Tension Third, TT; Intermediary Third, IT; Compression Third, CT) and prepared for conventional and polarized light microscopy. At 6 weeks, while the CT repaired faster and showed bone union by woven bone formation, the TT and IT exhibited a ligament-like fibrous connective tissue inserted in, and connecting, newly formed woven bone overlying the parent lamellar bone edges. At 12 weeks, bone repair took place at all thirds. Histometrically, proportions of newly formed bone did not alter at TT, IT and CT, whereas significantly enhanced bone formation was observed for the 12-week group, irrespective of the third. The results demonstrated that although the method used to stabilize the mandibular osteotomy allowed bone repair to occur, differences in the dynamics of bone healing may take place along the osteotomy site, depending on the action of tension and compression forces generated by masticatory muscles.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim To compare a new root canal sealer based on Copaifera multijuga oil-resin (Biosealer) using three other established sealers (Sealer 26 (R), Endofill (R) and AH plus (R)) in terms of their physicochemical properties. Methodology The study was carried out according to the requirements of Specification Number 57 of the American Dental Association (ADA) and consisted of the following tests: setting time, flow, film thickness, dimensional stability, radiopacity and solubility/disintegration. Data were analysed statistically using anova and Tukey`s test for multiple comparisons. The significance level was set at 5% for all analyses. Results Sealer 26 (R) and AH Plus (R) had the longest setting time (P < 0.05). All materials presented flow in with the ADA`s guidelines. Regarding film thick-ness, Sealer 26 (R) did not have a satisfactory performance, as it had a higher mean value than the maximum allowed by the ADA (0.05 mm), being significantly different from the other materials (P < 0.05), which had mean values for film thickness in accordance with the ADA`s recommendations. Regarding the solubility and disintegration, only Endofill (R) did not meet the ADA`s specifications and presented the worst results of all materials (P < 0.05). Sealer 26 (R) presented the greatest dimensional changes and differed significantly from all other sealers (P < 0.05). Biosealer had the lowest radiopacity values and was significantly different from the other sealers (P < 0.05). Conclusion The experimental sealer based on Copaifera multijuga oil-resin presented satisfactory results in the physicochemical tests required by the ADA.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

P>This study assessed the effect of simulated mastication on the retention of two stud attachment systems for 2-implants overdentures. Sixteen specimens, each simulating an edentulous ridge with implants and an overdenture were divided into two groups, according to the attachment system: Group I (Nobel Biocare ball-socket attachments) and Group II (Locator attachments). Retention forces were measured before and after 400 000 simulated masticatory loads in a customised device. Data were compared by two-way anova followed by Bonferroni test (alpha = 0 center dot 05). Group I presented significantly lower retention forces (Newtons) than Group II at baseline (10 center dot 6 +/- 3 center dot 6 and 66 center dot 4 +/- 16 center dot 0, respectively). However, differences were not significant after 400 000 loads (7 center dot 9 +/- 4 center dot 3 and 21 center dot 6 +/- 17 center dot 0). The number of cycles did not influence the measurements in Group I, whereas a non-linear descending curve was found for Group II. It was concluded that simulated mastication resulted in minor changes for the ball attachment tested. Nevertheless, it reduced the retention of Locator attachments to 40% of the baseline values, what suggests that mastication is a major factor associated with maintenance needs for this system.